期刊文献+
共找到33篇文章
< 1 2 >
每页显示 20 50 100
Microstructure and dry wear properties of Ti-Nb alloys for dental prostheses 被引量:2
1
作者 徐丽娟 肖树龙 +2 位作者 田竟 陈玉勇 黄玉东 《中国有色金属学会会刊:英文版》 CSCD 2009年第S3期639-644,共6页
The microstructure and properties of a series of binary Ti-Nb alloys for dental prostheses with niobium contents ranging from 5% to 20% were investigated. The experimental results indicate that the crystal structure a... The microstructure and properties of a series of binary Ti-Nb alloys for dental prostheses with niobium contents ranging from 5% to 20% were investigated. The experimental results indicate that the crystal structure and morphology of Ti-Nb alloys are sensitive to their niobium contents. When Nb content is 5%, the acicular α crystal grain is observed. When Nb content is 10%, the coarse equiaxed crystal grain and the fine, acicular α crystal grain are observed. When Nb content is 15%, only the α equiaxed crystal grain is observed. When the alloy contains 20%Nb, the equiaxed and dendritic α crystal grain are observed. For Ti-Nb alloys, the increase of Nb content modifies the microstructure of Ti-Nb alloys significantly and decreases their compression elastic modulus, in which Ti-20Nb alloy shows the largest compression strength and Ti-5Nb alloy shows the best plasticity. The dry wear resistance of Ti-Nb alloys against Gr15 ball was investigated on CJS111A ball-disk wear instrument. For Ti-Nb alloys, Ti-10Nb alloy shows a smallest steady friction coefficient, Ti-5Nb alloy shows the smallest wear depth and best wear resistance, and Ti-15Nb alloy shows the largest wear depth and worst wear resistance. The phenomenon of furrow cut happens and furrows form during wear tests. 展开更多
关键词 TI-NB alloy MICROSTRUCTURE DRY WEAR resistance DENTAL prostheses material
下载PDF
Preparation and Mechanical Performance of Blended Polyester/Silk Small Diameter Arterial Prostheses
2
作者 杨小元 王璐 +2 位作者 关国平 关颖 KING W Martin 《Journal of Donghua University(English Edition)》 EI CAS 2013年第5期356-358,共3页
Small diameter arterial prostheses were required to treat coronary and cerebrovascular arterial diseases. The diameters of the artificial blood vessels should match the diameters of the host arteries. Besides,the mech... Small diameter arterial prostheses were required to treat coronary and cerebrovascular arterial diseases. The diameters of the artificial blood vessels should match the diameters of the host arteries. Besides,the mechanical properties of the arterial prostheses should be strong enough to endure the forces in the body after implantation. In this study,silk and polyester were woven into small diameter arterial prostheses and the dimensional and mechanical properties,as well as the water permeability,were investigated. The woven samples had an inner diameter ranging from 3. 65 to 3. 94mm. The wall thickness of the samples ranged from 0. 26 to 0. 28mm. Compared with polytetrafiuoroethylene( ePTFE) commercial devices,whose probe bursting strength was measured to be 15. 64 N /mm2,the woven samples had superior strength values ranging from20. 53 to 28. 97 N /mm2. In addition,the radial compliance of the woven samples was found to lie between the ePTFE sample and the pig's carotid artery,and the water permeability of all the woven samples was less than 300 mL /( cm2·min) which indicated that these woven samples could be implanted without preclotting. 展开更多
关键词 SILK polyester woven ARTERIAL prostheses mechanical properties
下载PDF
New Design of Textile Vascular Prostheses for the Reconstruction of Small Diameter Vascular Blood Vessels
3
作者 CHRZANOWSKA Olga STRUSZCZYK Marcin Henryk KRUCINSKA Izabella 《Journal of Donghua University(English Edition)》 EI CAS 2013年第5期401-405,共5页
The general object of research is to design new idea of the semi-biodegradable,multilayered vascular prosthesis used for the reconstruction of significantly small diameter vascular vessels( microreconstruction). The p... The general object of research is to design new idea of the semi-biodegradable,multilayered vascular prosthesis used for the reconstruction of significantly small diameter vascular vessels( microreconstruction). The paper studies the selection of appropriate sterilization technique for resorbable tubular structures made of poly( L-lactide-co-glicolide)( PLAGA) and nonbiodegradable tubular structures made of polypropylene( PP). The designed grafts are characterized by the physical properties as well as mechanical properties according to ISO 7198 ∶ 1998 Standard.Moreover,the process of the grafts fabrication will be explained considering the stages affected the critical properties of the elaborated textile implants. The increase of PLAGA melt-electrospun tubular structures mechanical properties was observed due to the thermal stabilization use. The ethylene oxide( EO) and steam sterilization had a destructive effect on the designed PLAGA meltelectrospun tubular, fibrous structures, whereas the irradiation yielded in the changes in mechanical and physical properties on the acceptable level,taking into account the future clinical applications. 展开更多
关键词 VASCULAR prostheses melt-electrospinning MELT-BLOWN STERILIZATION
下载PDF
Binding mechanism of interface of porous coated titanium alloy prostheses
4
作者 邹宏思 叶军 +1 位作者 唐农轩 袁存华 《Journal of Medical Colleges of PLA(China)》 CAS 1996年第1期14-17,21,共5页
BindingmechanismofinterfaceofporouscoatedtitaniumalloyprosthesesZouHongen(邹宏思);YeJun(叶军);TangNongxuan(唐农轩);Y... BindingmechanismofinterfaceofporouscoatedtitaniumalloyprosthesesZouHongen(邹宏思);YeJun(叶军);TangNongxuan(唐农轩);YuanCunhua(袁存华)(De... 展开更多
关键词 porous-coated prostheses INTERLOCKING FIXATION binding mechanism
下载PDF
Anticoagulation in Pregnant Women with Mechanical Heart Valve Prostheses: 25-Year Experience at a Tertiary Care Hospital in a Developing Country
5
作者 Ahmed Tounsi Dorra Abid +8 位作者 Doulira Louati Souad Mallek Malek Akrout Leila Abid Mohamed Abdennadher Imed Frikha Kais Chaabene Mourad Hentati Samir Kammoun 《World Journal of Cardiovascular Diseases》 2014年第6期287-293,共7页
The aim of this retrospective study was to compare the different anticoagulation regimens used in pregnant women with prosthetic heart valves. We reviewed 86 pregnancies in 57 women from 1987 to 2011. The patients wer... The aim of this retrospective study was to compare the different anticoagulation regimens used in pregnant women with prosthetic heart valves. We reviewed 86 pregnancies in 57 women from 1987 to 2011. The patients were divided into two groups: group A (39 pregnancies) had oral acenocoumarol throughout pregnancy;and in group B (47 pregnancies), acenocoumarol was replaced by subcutaneous heparin during the first trimester. Both groups received heparin at the time of delivery. The valves replaced were mitral (59.65%), aortic (12.28%), or both (28.07%). 74 pregnancies (86.04%) resulted in live births, 9 (10.46%) had stillbirths, 1 (1.16%) had spontaneous abortion and 2 (2.32%) underwent therapeutic abortions. The live birth rate was higher in women on heparin (87.23%) compared with those on acenocoumarol (84.61%). No malformations appeared in the 74 newborns, except for one case of hydrocephalus. There was one maternal death due to acute mitral valvular thrombosis while on heparin in the first trimester. Hemorrhagic complications occurred in 13 patients in the postpartum period, 4 of whom required transfusion. No anticoagulant regimen can be said to be entirely safe for use during pregnancy as there is a degree of risk with each regimen. Heparin does not offer a clear advantage over oral anticoagulation in the pregnancy outcome. 展开更多
关键词 ANTICOAGULATION Pregnancy Mechanical Heart Valve prostheses MATERNAL COMPLICATIONS HEPARIN ACENOCOUMAROL
下载PDF
Anatomical and Functional Preliminary Results of Total Non-Cemented Hip Prostheses
6
作者 A. M. Abdoul Wahab M. Koini +4 位作者 B. Dembele A. D. Sane A. N’Diaye C. Dieme N. F. Coulibaly 《Open Journal of Orthopedics》 2017年第10期329-336,共8页
The aim of this work was to assess the preliminary anatomical and functional results of patients to establish prospects. Materials and method: We report here the preliminary results of a retrospective mono-centric, ho... The aim of this work was to assess the preliminary anatomical and functional results of patients to establish prospects. Materials and method: We report here the preliminary results of a retrospective mono-centric, homogeneous and continuous series, of 21 non-cemented total hip implants, implanted from January 2011 to December 2014. The mean follow-up time was 24 months. The patients were evaluated by Harris’s hip at the last follow-up. Results: The mean age of the intervention was 30 years. In our series, we observed a male predominance (60% of cases). Clinically, the Harris score varied significantly from 52.6 ± 11.4 pre-operatively to 85.1 ± 5.1 during the last follow-up visit. Among the items in the score, pain was the parameter that showed the greatest improvement. Thigh pain was observed in only one patient operated on the two sides. At the level of radiology, the femoral implant showed great stability. Bone resorption was suspected in 14 cases (66.66%), and confirmed in 4 cases (19.04%) with excellent bone remodeling, illustrated by the Engh and Massin scores. A loosening and a prosthetic dislocation was observed in a patient (4.76%). Any heterotopic ossification was observed. Conclusion: Our study confirmed good clinical and radiological results of the non-cemented hip prosthesis series in young patients. The rates of aseptic loosening, acetabular edges or osteolysis are low and stable over time. 展开更多
关键词 HIP TOTAL Non-Cemented prostheses
下载PDF
Iatrogenic Oesophageal Perforations in Neoplastic Lesions: Management with Covered Self-Expanding Prostheses
7
作者 Mario Anselmi Mendez Ana MarÍA Gemmato Pascazio +1 位作者 Maximiliano Figueroa Silva Julio Salgado OyarzÚN 《Open Journal of Gastroenterology》 2021年第6期89-104,共16页
<span><span style="white-space:nowrap;font-family:Verdana;"><strong>Background:</strong></span><strong><span style="font-family:Verdana;"></span><... <span><span style="white-space:nowrap;font-family:Verdana;"><strong>Background:</strong></span><strong><span style="font-family:Verdana;"></span></strong></span><span>Perforation of the oesophagus is a serious condition. Most of them are iatrogenic and are associated with significant morbidity and mortality, especially with late diagnosis. </span><b><span style="font-family:Verdana;">Aim:</span></b><span style="font-family:Verdana;"> To prospectively analyse the results of the endoscopic management of iatrogenic perforations in oesophageal neoplasia, through the immediate insertion of a covered self-expanding prosthesis (CSES). </span><b><span style="font-family:Verdana;">Materials and Methods:</span></b><span style="font-family:Verdana;"> Between 01.01.2006 and 12.30.2016, a series of 19 consecutive patients attended the Teaching Unit of Endoscopic Surgery of the Regional de Concepción Hospital, Chile, with the diagnosis of oesophageal neoplasia confirmed by biopsy were prospectively studied. All were subjected to a prior evaluation by the oncology team and subsequently referred for endoscopic palliative management of dysphagia. The average age was 77 ± 9.3 years, 8 (42.1%) were female and 11 (57.9%) were male. In 17 patients (89.5%) the stenosis compromised the oesophagus, in 2 (10.5%) the gastro-oesophageal junction, 16 had a squamous carcinoma (84.2%) and 3 an adenocarcinoma (15.8%). </span><b><span style="font-family:Verdana;">Results: </span></b><span style="font-family:Verdana;">Perforation was diagnosed during the procedure in 18 patients (94.7%) and in 1 (5.3%) 22 hours later. Follow-up was done for a minimum of 90 days or until death. The prostheses were inserted successfully in all cases. The immediate evolution was satisfactory in 12 patients (63.2%). In the rest (36.8%), 18 complications appeared. The most frequent were retrosternal pain, subcutaneous emphysema and fever. The early evolution was satisfactory in 12/19 cases (63.2%). Complication was evidenced in 7 (36.8%), the most frequent was retrosternal pain (36.8%). Fever occurred in 3 (15.8%), pleural effusion in 3 (15.8%) and mediastinitis in 2 of these. The prosthesis was kept in situ as a definitive palliation method for neoplas</span><span><span style="font-family:Verdana;">tic dysphagia. In 10 of the 18 cases that survived more than a month, there were late complications (55.6%), none of them associated with the perforation itself. The only death (5.3%) was due to an oesophagus-pleural fistula, associated with an early prosthetic migration. Recovery of the oral intake occurred, on average, at 3.7 days. The hospital stay averaged 9.6 days. </span><b><span style="font-family:Verdana;">Conclusion: </span></b><span style="font-family:Verdana;">The use of CSES for the treatment of iatrogenic oesophageal perforations in the context of neoplasia, is a safe and effective method, with low morbidity, adequate recovery of the oral intake and prompt discharge from hospital.</span></span> 展开更多
关键词 Iatrogenic Oesophageal Perforations Self-Expanding prostheses Oesophageal Cancer
下载PDF
Influence of Ni and Cr Content on Corrosion Resistance of Ni-Cr-Mo Alloys for Fixed Dental Prostheses in 0.05% NaF Aqueous Solution
8
作者 Nilo A. S. Sampaio José W. J. Silva +3 位作者 Heloisa A. Acciari Roberto Z. Nakazato Eduardo N. Codaro Hamilton de Felipe 《Materials Sciences and Applications》 2010年第6期369-372,共4页
The Ni-Cr-Mo alloys have been used as dental prostheses because they own a good mechanical strength, high corrosion resistance and even to be economically viable. These alloys corrosion protection against in salt solu... The Ni-Cr-Mo alloys have been used as dental prostheses because they own a good mechanical strength, high corrosion resistance and even to be economically viable. These alloys corrosion protection against in salt solutions typical of physiological media is due to passivation phenomenon with an oxide surface layer formation, mainly chromium oxides. This protective film, subjected to a mechanical stress in a corrosive environment, can partially dissolve by releasing ions, which have deleterious effects in a human body. Fluoride ions, existing in hygiene products, change the buccal environment and their presence may enable a localized corrosion process initiation. The aim of this work has been to investigate the chemical composition influence of three alloys in corrosion resistance to: A (Ni-73% Cr-14% Mo-8.5% Be-1.8% Al-1.8%), B (Ni-61% Cr-25% Mo-10.5% Si-1.5%) and C (Ni-65% Cr-22.5% Mo-9.5%) in media containing fluorides that simulate mouthwashes solution. The study has been done in a 0.05% NaF solution, pH 6, at 37°C using electrochemical techniques. The alloy with the highest nickel and the lowest chromium content is not passive in the middle studied, showing a continuous increase in current density with the potential increasing, while the other alloys show passivation range of 600 mV and passive current density of about 10-6 A/cm2. 展开更多
关键词 NI-CR-MO ALLOYS Dental prostheses Corrosion
下载PDF
Implant-Supported Full Fixed Prostheses with a Removable Oro-Nasal Obturator for the Edentulous Maxilla with Palatal Fistula due to Surgical Procedures for Oral Cancer
9
作者 Akifumi Enomoto Takeshi Shimoide +4 位作者 Eri Morikage Kazuhide Matsunaga Takao Mukai Takayuki Uchihashi Suguru Hamada 《Surgical Science》 2016年第10期443-452,共10页
Open oro-nasal defects resulting after oral tumor resection need structural and functional rehabilitation using dental prostheses. Conventional removable prostheses have usually been indicated and performed for prosth... Open oro-nasal defects resulting after oral tumor resection need structural and functional rehabilitation using dental prostheses. Conventional removable prostheses have usually been indicated and performed for prosthodontics. When the patient has an edentulous maxilla, the unfavorable stability of the prosthesis will cause dysfunction of mastication and pronunciation. To achieve improvement of the impaired functional situation, implant-supported full fixed prostheses (IPSPs) for the edentulous maxilla with a removable obturator offer a reasonable solution. We present herein the case of a 70-year-old Japanese man who has presented with oro-nasal defect due to surgical procedures for oral cancer. He was treated with implant-supported full fixed prostheses in a conventional two-step procedure. After prosthesis treatment, a palatal obturator was set. The patient has shown no clinical or radiological evidence of failure as of 24 months after the end of treatment. Functional evaluation of mastication and pronunciation showed dramatic improvements. For a patient with an edentulous maxilla and palatal fistula, full-arch fixed prostheses supported by a combination of axially and non-axially positioned implants and a removable oro-nasal obturator, using the anterior alveolar bone, without bone transplantation or maxillary sinus elevation, could offer an effective, minimally invasive treatment alternative. 展开更多
关键词 Implant-Supported Full Fixed prostheses Oro-Nasal Obturator Oral Tumor
下载PDF
Myoelectric prostheses for special stumps
10
作者 Luo Yong-Zhao(Shanghai Institute of Physiology Chinese Academy of Sciences,Shanghai 200031,PR.China) 《Chinese Journal of Biomedical Engineering(English Edition)》 1999年第3期4-4,共1页
关键词 Myoelectric prostheses for special stumps
下载PDF
Testicular prostheses-impact on quality of life and sexual function
11
作者 Ana Sofia Araujo Sara Anacleto +4 位作者 Ricardo Rodrigues Catarina Tinoco Andreia Cardoso Carlos Oliveira Ricardo Leao 《Asian Journal of Andrology》 SCIE CAS CSCD 2024年第2期160-164,共5页
Orchiectomy is the recommended treatment for many testicular conditions.However,testicular prosthesis placement is not always performed for different reasons.In this study,we aimed to evaluate patients'opinions an... Orchiectomy is the recommended treatment for many testicular conditions.However,testicular prosthesis placement is not always performed for different reasons.In this study,we aimed to evaluate patients'opinions and the impact on sexual function and quality of life.This retrospective observational single-center study included patients who underwent orchiectomy between January 2014 and December 2020 at the Department of Urology,Braga's Hospital(Braga,Portugal),where testicular implants were always available and the decision to undergo the procedure was made fully independent of cost.Patients completed four questionnaires that assessed demographic data,satisfaction,self-esteem,and sexual function.Of the 96 patients who underwent orchidectomy,59 replied to the questionnaires,and of these patients,86.4%decided to undergo silicone-based testicular prostheses implantation.The remaining 13.6%refused the implant based on concerns about complications(37.5%),because they felt that it was unnecessary(37.5%),or because it was not offered by the doctor(25.0%).Overall,96.1%of these patients were satisfied with the implant;however,25.5%classified it as"too firm".No statistically significant differences were found in sexual function(all P>0.05).However,it can be observed that there are more patients with prostheses presenting normal sexual activity compared to patients without prostheses(74.0%vs 50.0%),and none of them reported severe erectile dysfunction(0 vs 16.7%).Regarding self-esteem,both patients with and without prostheses present very similar average scores with no statistically significant differences.The present study highlights the highest level of satisfaction among patients who received testicular prostheses.Testicular prostheses implantation is a safe procedure that does not hamper sexual function after orchiectomy. 展开更多
关键词 ORCHIECTOMY patient satisfaction quality of life sexual dysfunction sexual health testicular prostheses
原文传递
Three-dimensional-printed titanium prostheses with bone trabeculae enable mechanical-biological reconstruction after resection of bone tumours 被引量:1
12
作者 Feifei Pu Wei Wu +7 位作者 Doudou Jing Yihan Yu Yizhong Peng Jianxiang Liu Qiang Wu Baichuan Wang Zhicai Zhang Zengwu Shao 《Biomaterials Translational》 2022年第2期134-141,共8页
Reconstruction after resection has always been an urgent problem in the treatment of bone tumours.There are many methods that can be used to reconstruct bone defects;however,there are also many complications,and it is... Reconstruction after resection has always been an urgent problem in the treatment of bone tumours.There are many methods that can be used to reconstruct bone defects;however,there are also many complications,and it is difficult to develop a safe and effective reconstruction plan for the treatment of bone tumours.With the rapid development of digital orthopaedics,three-dimensional printing technology can solve this problem.The three-dimensional printing of personalised prostheses has many advantages.It can be used to print complex structures that are difficult to fabricate using traditional processes and overcome the problems of stress shielding and low biological activity of conventional prostheses.In this study,12 patients with bone tumours were selected as research subjects,and based on individualised reverse-engineering design technology,a three-dimensional model of each prosthesis was designed and installed using medical image data.Ti6Al4V was used as the raw material to prepare the prostheses,which were used to repair bone defects after surgical resection.The operation time was 266.43±21.08 minutes(range 180-390 minutes),and intraoperative blood loss was 857.26±84.28 mL(range 800-2500 mL).One patient had delayed wound healing after surgery,but all patients survived without local tumour recurrence,and no tumour metastasis was found.No aseptic loosening or structural fracture of the prosthesis,and no non-mechanical prosthesis failure caused by infection,tumour recurrence,or progression was observed.The Musculo-Skeletal Tumour Society(MSTS)score of limb function was 22.53±2.09(range 16-26),and ten of the 12 patients scored≥20 and were able to function normally.The results showed that three-dimensional printed prostheses with an individualised design can achieve satisfactory short-term clinical efficacy in the reconstruction of large bone defects after bone tumour resection. 展开更多
关键词 bone defect bone tumour printed biomechanical reconstruction prostheses THREE-DIMENSIONAL
原文传递
Prosthetic reconstruction of the trachea:A historical perspective 被引量:2
13
作者 Jagdeep S Virk Henry Zhang +1 位作者 Reza Nouraei Guri Sandhu 《World Journal of Clinical Cases》 SCIE 2017年第4期128-133,共6页
This review discusses the history of tracheal reconstruction; from early work to future challenges. The focus is primarily on prosthetic tracheal reconstruction in the form of intraluminal stents, patch repairs, circu... This review discusses the history of tracheal reconstruction; from early work to future challenges. The focus is primarily on prosthetic tracheal reconstruction in the form of intraluminal stents, patch repairs, circumferential repairs and replacement of the trachea. A historical perspective of materials used such as foreign materials, autografts, allografts, xenografts and techniques, along with their advantages and disadvantages, is provided. 展开更多
关键词 TRACHEAL STENOSIS TRACHEA prostheses and implants STENTS
下载PDF
A Review of the Application of Additive Manufacturing in Prosthetic and Orthotic Clinics from a Biomechanical Perspective 被引量:2
14
作者 Yan Wang Qitao Tan +2 位作者 Fang Pu David Boone Ming Zhang 《Engineering》 SCIE EI 2020年第11期1258-1266,共9页
Prostheses and orthoses are common assistive devices to meet the biomechanical needs of people with physical disabilities.The traditional fabrication approach for prostheses or orthoses is a materialwasting,time-consu... Prostheses and orthoses are common assistive devices to meet the biomechanical needs of people with physical disabilities.The traditional fabrication approach for prostheses or orthoses is a materialwasting,time-consuming,and labor-intensive process.Additive manufacturing(AM)technology has advantages that can solve these problems.Many trials have been conducted in fabricating prostheses and orthoses.However,there is still a gap between the hype and the expected realities of AM in prosthetic and orthotic clinics.One of the key challenges is the lack of a systematic framework of integrated technologies with the AM procedure;another challenge is the need to design a prosthetic or orthotic product that can meet the requirements of both comfort and function.This study reviews the current state of application of AM technologies in prosthesis and orthosis fabrication,and discusses optimal design using computational methods and biomechanical evaluations of product performance.A systematic framework of the AM procedure is proposed,which covers the scanning of affected body parts through to the final designed adaptable product.A cycle of optimal design and biomechanical evaluation of products using finite-element analysis is included in the framework.A mature framework of the AM procedure and sufficient evidence that the resulting products show satisfactory biomechanical performance will promote the application of AM in prosthetic and orthotic clinics. 展开更多
关键词 Additive manufacturing Biomechanics of the musculoskeletal system Computational model prostheses and orthoses 3D printing
下载PDF
Endovascular Stents in Arterial Injury after Radiotherapy 被引量:1
15
作者 刘鹏程 PerreaultPierre +7 位作者 OtalPhilippe ColombierDanial BerregiJean-Paul BastideCyri1 CercueilJean-Pierre KrauseDenis RousseauHelve JoffreFrancis 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1998年第4期253-256,261,共5页
We evaluated preliminary success and patency of stenting for the treatment of radiation-induced arterial diseases. Thirteen stents were placed in 8 patients to treat occlusion (n=3), aneurysm (n=1), residual stenosis ... We evaluated preliminary success and patency of stenting for the treatment of radiation-induced arterial diseases. Thirteen stents were placed in 8 patients to treat occlusion (n=3), aneurysm (n=1), residual stenosis (n=2),multiple stenoses (n=1), and delayed restenosis after previous balloon angioplasty (n=1). Interventional procedure was successfully performed in 8 patients for their arterial lesions after radiotherapy. Six patients underwent interventional procedure once or twice. Two patients underwent PTA 4 times. Five of these patients demonstrated primary patency with relief of clinical symptoms with a mean follow-up of 2 years (range: 8-60 months). Clinical improvement was noted in the other patients. Our results suggest that stent placement by single or multiple techniques may have immediate effect on arterial lesions caused by radiation and can be considered as a therapeutic option of choice in these cases. 展开更多
关键词 ARTERIES TRANSLUMINAL ANGIOPLASTY radiation injurious effect STENTS and prostheses
下载PDF
Influence of Structures on the Mechanical Properties of PET Biotextiles 被引量:1
16
作者 刘肖燕 王璐 丁永生 《Journal of Donghua University(English Edition)》 EI CAS 2014年第2期106-108,共3页
Occurrence of vascular diseases is increasing and leads to rising demand for the STENT-GRAFT( SG). To ensure the SG function properly,the materials should have low blood permeability and good mechanical properties. So... Occurrence of vascular diseases is increasing and leads to rising demand for the STENT-GRAFT( SG). To ensure the SG function properly,the materials should have low blood permeability and good mechanical properties. So far, there have been few systematic studies on the relationship between textile structures and mechanical properties of the bio-textiles used in the SG. In this study, six types of biomedical PET fabrics with different yarn structures and fabric structures were designed and fabricated. All the SG materials could meet the requirement of thickness,except the sample of 30 d × 20 d with 2 /2 twill construction,which was thicker than 0. 12 mm. Bursting strength and water permeability( WP) of the six samples were also tested. Through the comparison of comprehensive performance,the PET fabric 30 d × 20 d /12 f with2 /2 twill construction with both good resistances to permeability and bursting strength, might have good prospect in applications of vascular engineering. 展开更多
关键词 endovascular prostheses textile structure water permeability bursting strength thickness
下载PDF
Total hip replacement using MINIMA^(■)short stem:A short-term follow-up study 被引量:1
17
作者 Georgios I Drosos Stylianos Tottas +3 位作者 Ioannis Kougioumtzis Konstantinos Tilkeridis Christos Chatzipapas Athanasios Ververidis 《World Journal of Orthopedics》 2020年第4期232-242,共11页
BACKGROUND Total hip replacement has become one of the most successful orthopaedic procedures.The length of the femoral stem constitutes one of the most important geometrical and mechanical features of the prosthesis.... BACKGROUND Total hip replacement has become one of the most successful orthopaedic procedures.The length of the femoral stem constitutes one of the most important geometrical and mechanical features of the prosthesis.Several different implants are currently available but data are limited concerning the clinical results for some of these implants.AIM To report the short-term clinical and radiological results of a novel squared section,tapered design–with four conicity-short stem in total hip replacement.METHODS This is a retrospective study of a prospectively collected data using of MINIMA?short stem in 61 consecutive patients with at least 1 year follow-up.The collected data included patients’demographics,type of arthritis,bone morphology,perioperative data,clinical results using Harris Hip Score,EuroQol(EQ-5D),pain score and satisfaction rate,complications and radiological results.RESULTS Total 61 patients were included in our study with a mean age of 56 years of age(range 25-73 years).The majority of them(68.6%)were women,thirty seven patients(56.9%)were less than 60 years of age and almost half of patients(45.1%)suffered from secondary osteoarthritis(hip dysplasia,osteonecrosis,etc.).The mean time of follow-up examination was 33.4 mo(2.8 years)with a range of 12-57 months(1-4.8 years).In 35 patients(56.9%)the follow-up examination was more than 3 years.No major complications such as revision,periprosthetic fracture,dislocation or infection were presented.Re-admission 90 d postoperatively or laterwas deemed unnecessary for any reason regarding the operation.Respectively,the mean pain score,mean Harris hip score,and mean EQ-5D were improved from 6.3,58.7 and 77.3 preoperatively to 0.1,95.1,and 79.8 postoperatively.The Satisfaction rate at the final follow-up was 9.9(SD 0.3,range 8.0-10.0).All stems were classified as stable bone ingrowth and no radiolucent lineswere revealed in any of the modified Gruens’zone at the postoperative Xrays.Stem subsidence was within acceptable limits and the incidence of distal cortical hypertrophy was relatively low.CONCLUSION The clinical and radiological results concerning the MINIMA?short stem are excellent according to this first report of this specific design of the short femoral stems.Because of the small number of cases and short-term follow-up of this study,a longer follow up time and more patients’enrollment is required. 展开更多
关键词 Total hip replacement Total hip arthroplasty Short-stem Hip prostheses Femoral components MINIMA^(■) stem
下载PDF
Process Modelling and Experimental Analysis of Optimal Specimen Selection in Organic CMCs
18
作者 P.V.Rajesh Kanak Kalita Xiao-Zhi Gao 《Computers, Materials & Continua》 SCIE EI 2022年第2期2415-2433,共19页
Bone grafting is a surgical restructuring procedure of replacing broken bones and reconstructing missing bone pieces so that complex bone fractures can be repaired to avoid any serious health risk as well as permanent... Bone grafting is a surgical restructuring procedure of replacing broken bones and reconstructing missing bone pieces so that complex bone fractures can be repaired to avoid any serious health risk as well as permanent bone disfiguration.Normally,human bones tend to regenerate and heal completely from fracture.But it needs a small scaffold to provide the necessary space to grow.Bone implants allow a broken bone to grow seamlessly.Traditionally,non-corrosive metal alloys are used for fixing broken bones.A metal plate is fastened between two ends of broken bones to join them.However,issues like high weight,high cost,low wear resistance,etc.led to the emergence of ceramics and ceramic-based composites in surgical engineering.Recent trends indicate the usage of organic ceramics and their associated composites as biomimeticmaterials for prostheses and other biomedical applications.This research paper deals with the fabrication of one such type of ceramic matrix composite(CMC)specimen with sea sponge and cuttlebone using powder metallurgy process by varying composition of cuttlebone,the particle size of the ceramics and sintering temperature of green compacts.Evaluation of thermo-mechanical properties and optimization of process parameters is carried out using the preferential selection index(PSI)method.The results obtained from this technique are further validated usingMulti-Level General Factorial Design(MLGFD). 展开更多
关键词 GRAFTING IMPLANTS ceramics composites prostheses powder metallurgy optimization
下载PDF
Influence of pontic design of anterior fixed dental prosthesis on speech: A clinical case study
19
作者 Jia Wan He Cai +1 位作者 Tong Wang Jun-Yu Chen 《World Journal of Clinical Cases》 SCIE 2021年第36期11276-11284,共9页
BACKGROUND The pontic design of fixed dental prostheses(FDPs)is strongly associated with the phonetic function,and the phonetic function of anterior FDPs with different pontic designs remains understudied.AIM To inves... BACKGROUND The pontic design of fixed dental prostheses(FDPs)is strongly associated with the phonetic function,and the phonetic function of anterior FDPs with different pontic designs remains understudied.AIM To investigate the immediate and short-term influence of pontic design of anterior FDPs on Chinese speech in a clinical case using objective acoustic analysis.METHODS Two FDPs with two types of pontic design(saddle pontic and modified ridge lap pontic)were fabricated for one patient with maxillary anterior teeth missing.The acoustic analysis of patient’s articulation was conducted immediately after wearing the FDPs and 1 wk after wearing these FDPs.RESULTS The effect of FDP on Chinese vowels(/a/,/o/,/e/,/i/,/u/,and/ü/)was insignificant,because the recovery of vowel distortion occurred within 1 wk for both FDPs.Three(/f/,/s/,and/sh/)of eight Chinese fricative consonants were found to have obvious distortions,and the/s/sound distortion last for more than 1 wk for the patient wearing FDP with modified ridge lap pontic design.CONCLUSION The influence of anterior FDP on articulation of Chinese vowels is insignificant,while the articulation of Chinese fricative consonants is more susceptible.When fabricating anterior FDPs for patients with speech related professions,saddle pontic design can be an alternative option compared with modified ridge lap pontic design. 展开更多
关键词 Fixed dental prostheses Acoustic analysis Phonetic function Pontic design Clinical case study
下载PDF
Computer-Aided Design and Fabrication of Finger Prosthesis
20
作者 Takeshi Murayama Kosei Oono +3 位作者 Mitsunori Tada Toru Eguchi Misuzu Nagami Mitsuhiro Tamamoto 《Journal of Biomedical Science and Engineering》 2015年第2期98-103,共6页
Custom-made esthetic finger prostheses, which are used for rehabilitation of patients with missing or impaired fingers, have been fabricated manually. However, such fabrication is time-consuming and requires manual sk... Custom-made esthetic finger prostheses, which are used for rehabilitation of patients with missing or impaired fingers, have been fabricated manually. However, such fabrication is time-consuming and requires manual skill. Here we propose a computer-aided method for fabricating finger pros-theses to save time and allow fabrications that do not require considerable manual skill. In this method, the dimensions of a patient’s healthy finger on the contralateral hand are first measured using a caliper. Using these dimensions, a three-dimensional model is constructed for fabricating a prosthesis for the patient’s impaired finger. Using the 3D model, a mold is designed using 3D modeling tools and a computer-aided design system. The resulting mold is then fabricated using a 3D printer. A finger prosthesis is fabricated by pouring silicone resin into the mold. A finger prosthesis for a volunteer was experimentally fabricated according to the proposed method. To evaluate the size and shape of the finger prosthesis, the difference between the finger prosthesis and the original finger of the volunteer was analyzed. Because the average difference between them was 0.25 mm, it was concluded that the proposed method could be used to fabricate a finger prosthesis of adequate size and shape. 展开更多
关键词 FINGER prostheses ESTHETIC prostheses COMPUTER-AIDED Design 3D PRINTER Additive Manufacturing
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部