Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ ...Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ synthesis method,including small size and low dosage,bring about difficulties in quantitative analysis and differences in ignition capabilities of CA chips.The aim of present work is to develop a simplified quantitative analysis method for accurate and safe analysis of components in CA chips to evaluate and investigate the corresponding ignition ability.In this work,Cu(N_(3))2 and CuN_(3)components in CA chips were separated through dissolution and distillation by utilizing the difference in solubility and corresponding content was obtained by measuring N_(3)-concentration through spectrophotometry.The spectrophotometry method was optimized by studying influencing factors and the recovery rate of different separation methods was studied,ensuring the accuracy and reproducibility of test results.The optimized method is linear in range from 1.0-25.0 mg/L,with a correlation coefficient R^(2)=0.9998,which meets the requirements of CA chips with a milligram-level content test.Compared with the existing ICP method,component analysis results of CA chips obtained by spectrophotometry are closer to real component content in samples and have satisfactory accuracy.Moreover,as its application in miniaturized explosive systems,the ignition ability of CA chips with different component contents for direct ink writing CL-20 and the corresponding mechanism was studied.This study provided a basis and idea for the design and performance evaluation of CA chips in miniaturized explosive systems.展开更多
Seeing is an important index to evaluate the quality of an astronomical site.To estimate seeing at the Muztagh-Ata site with height and time quantitatively,the European Centre for Medium-Range Weather Forecasts reanal...Seeing is an important index to evaluate the quality of an astronomical site.To estimate seeing at the Muztagh-Ata site with height and time quantitatively,the European Centre for Medium-Range Weather Forecasts reanalysis database(ERA5)is used.Seeing calculated from ERA5 is compared consistently with the Differential Image Motion Monitor seeing at the height of 12 m.Results show that seeing decays exponentially with height at the Muztagh-Ata site.Seeing decays the fastest in fall in 2021 and most slowly with height in summer.The seeing condition is better in fall than in summer.The median value of seeing at 12 m is 0.89 arcsec,the maximum value is1.21 arcsec in August and the minimum is 0.66 arcsec in October.The median value of seeing at 12 m is 0.72arcsec in the nighttime and 1.08 arcsec in the daytime.Seeing is a combination of annual and about biannual variations with the same phase as temperature and wind speed indicating that seeing variation with time is influenced by temperature and wind speed.The Richardson number Ri is used to analyze the atmospheric stability and the variations of seeing are consistent with Ri between layers.These quantitative results can provide an important reference for a telescopic observation strategy.展开更多
Laser-induced breakdown spectroscopy(LIBS)is a capable technique for elementary analysis,while LIBS quantitation is still under development.In quantitation,precise laser focusing plays an important role because it ens...Laser-induced breakdown spectroscopy(LIBS)is a capable technique for elementary analysis,while LIBS quantitation is still under development.In quantitation,precise laser focusing plays an important role because it ensures the distance between the laser and samples.In the present work,we employed spectral intensity as a direct way to assist laser focusing in LIBS quantitation for copper alloys.It is found that both the air emission and the copper line could be used to determine the position of the sample surface by referencing the intensity maximum.Nevertheless,the fine quantitation was only realized at the position where the air emission(e.g.O(I)777.4 nm)reached intensity maximum,and also in this way,a repeatable quantitation was successfully achieved even after 120 days.The results suggested that the LIBS quantitation was highly dependent on the focusing position of the laser,and spectra-assisted focusing could be a simple way to find the identical condition for different samples’detection.In the future,this method might be applicable in field measurements for LIBS analysis of solids.展开更多
To explore ways to improve the accuracy of quantitative analysis of samples in the micrometer to nanometer range of magnitudes,we adopted analytical transmission electron microscopy(AEM/EDS)for qualitative and quantit...To explore ways to improve the accuracy of quantitative analysis of samples in the micrometer to nanometer range of magnitudes,we adopted analytical transmission electron microscopy(AEM/EDS)for qualitative and quantitative analysis of pyrite materials.Additionally,the k factor of pyrite is calculated experimentally.To develop an appropriate non-standard quantitative analysis model for pyrite materials,the experimentally calculated k factor is compared with that estimated from the non-standard quantitative analytical model of the instrument software.The experimental findings demonstrate that the EDS attached to a TEM can be employed for precise quantitative analysis of micro-and nanoscale regions of pyrite materials.Furthermore,it serves as a reference for improving the results of the EDS quantitative analysis of other sulfides.展开更多
BACKGROUND Donor-recipient size mismatch(DRSM)is considered a crucial factor for poor outcomes in liver transplantation(LT)because of complications,such as massive intraoperative blood loss(IBL)and early allograft dys...BACKGROUND Donor-recipient size mismatch(DRSM)is considered a crucial factor for poor outcomes in liver transplantation(LT)because of complications,such as massive intraoperative blood loss(IBL)and early allograft dysfunction(EAD).Liver volumetry is performed routinely in living donor LT,but rarely in deceased donor LT(DDLT),which amplifies the adverse effects of DRSM in DDLT.Due to the various shortcomings of traditional manual liver volumetry and formula methods,a feasible model based on intelligent/interactive qualitative and quantitative analysis-three-dimensional(IQQA-3D)for estimating the degree of DRSM is needed.AIM To identify benefits of IQQA-3D liver volumetry in DDLT and establish an estimation model to guide perioperative management.METHODS We retrospectively determined the accuracy of IQQA-3D liver volumetry for standard total liver volume(TLV)(sTLV)and established an estimation TLV(eTLV)index(eTLVi)model.Receiver operating characteristic(ROC)curves were drawn to detect the optimal cut-off values for predicting massive IBL and EAD in DDLT using donor sTLV to recipient sTLV(called sTLVi).The factors influencing the occurrence of massive IBL and EAD were explored through logistic regression analysis.Finally,the eTLVi model was compared with the sTLVi model through the ROC curve for verification.RESULTS A total of 133 patients were included in the analysis.The Changzheng formula was accurate for calculating donor sTLV(P=0.083)but not for recipient sTLV(P=0.036).Recipient eTLV calculated using IQQA-3D highly matched with recipient sTLV(P=0.221).Alcoholic liver disease,gastrointestinal bleeding,and sTLVi>1.24 were independent risk factors for massive IBL,and drug-induced liver failure was an independent protective factor for massive IBL.Male donor-female recipient combination,model for end-stage liver disease score,sTLVi≤0.85,and sTLVi≥1.32 were independent risk factors for EAD,and viral hepatitis was an independent protective factor for EAD.The overall survival of patients in the 0.85<sTLVi<1.32 group was better compared to the sTLVi≤0.85 group and sTLVi≥1.32 group(P<0.001).There was no statistically significant difference in the area under the curve of the sTLVi model and IQQA-3D eTLVi model in the detection of massive IBL and EAD(all P>0.05).CONCLUSION IQQA-3D eTLVi model has high accuracy in predicting massive IBL and EAD in DDLT.We should follow the guidance of the IQQA-3D eTLVi model in perioperative management.展开更多
We make a quantitative study on the soliton interactions in the nonlinear Schro¨dinger equation(NLSE) and its variable–coefficient(vc) counterpart. For the regular two-soliton and double-pole solutions of the NL...We make a quantitative study on the soliton interactions in the nonlinear Schro¨dinger equation(NLSE) and its variable–coefficient(vc) counterpart. For the regular two-soliton and double-pole solutions of the NLSE, we employ the asymptotic analysis method to obtain the expressions of asymptotic solitons, and analyze the interaction properties based on the soliton physical quantities(especially the soliton accelerations and interaction forces);whereas for the bounded two-soliton solution, we numerically calculate the soliton center positions and accelerations, and discuss the soliton interaction scenarios in three typical bounded cases. Via some variable transformations, we also obtain the inhomogeneous regular two-soliton and double-pole solutions for the vcNLSE with an integrable condition. Based on the expressions of asymptotic solitons, we quantitatively study the two-soliton interactions with some inhomogeneous dispersion profiles,particularly discuss the influence of the variable dispersion function f(t) on the soliton interaction dynamics.展开更多
This paper demonstrates the importance of three-dimensional(3-D)piezoelectric coupling in the electromechanical behavior of piezoelectric devices using three-dimensional finite element analyses based on weak and stron...This paper demonstrates the importance of three-dimensional(3-D)piezoelectric coupling in the electromechanical behavior of piezoelectric devices using three-dimensional finite element analyses based on weak and strong coupling models for a thin cantilevered piezoelectric bimorph actuator.It is found that there is a significant difference between the strong and weak coupling solutions given by coupling direct and inverse piezoelectric effects(i.e.,piezoelectric coupling effect).In addition,there is significant longitudinal bending caused by the constraint of the inverse piezoelectric effect in the width direction at the fixed end(i.e.,3-D effect).Hence,modeling of these effects or 3-D piezoelectric coupling modeling is an electromechanical basis for the piezoelectric devices,which contributes to the accurate prediction of their behavior.展开更多
In the spectral analysis of laser-induced breakdown spectroscopy,abundant characteristic spectral lines and severe interference information exist simultaneously in the original spectral data.Here,a feature selection m...In the spectral analysis of laser-induced breakdown spectroscopy,abundant characteristic spectral lines and severe interference information exist simultaneously in the original spectral data.Here,a feature selection method called recursive feature elimination based on ridge regression(Ridge-RFE)for the original spectral data is recommended to make full use of the valid information of spectra.In the Ridge-RFE method,the absolute value of the ridge regression coefficient was used as a criterion to screen spectral characteristic,the feature with the absolute value of minimum weight in the input subset features was removed by recursive feature elimination(RFE),and the selected features were used as inputs of the partial least squares regression(PLS)model.The Ridge-RFE method based PLS model was used to measure the Fe,Si,Mg,Cu,Zn and Mn for 51 aluminum alloy samples,and the results showed that the root mean square error of prediction decreased greatly compared to the PLS model with full spectrum as input.The overall results demonstrate that the Ridge-RFE method is more efficient to extract the redundant features,make PLS model for better quantitative analysis results and improve model generalization ability.展开更多
The purpose of this study was to quantify the effect of the fatty acid alkyl-chain length of a polyethylene glycol(PEG)glyceryl ester,which was used as a microemulsion oil component,on the partitioning of highly lipop...The purpose of this study was to quantify the effect of the fatty acid alkyl-chain length of a polyethylene glycol(PEG)glyceryl ester,which was used as a microemulsion oil component,on the partitioning of highly lipophilic compounds to the mesenteric lymph after oral administration.Oil blue N,a highly lipophilic anthraquinone derivative,was orally administered to lymph duct-cannulated and untreated rats in two kinds of different microemulsions.Gelucire®50/13 and Gelucire®44/14 were used as the oil component with long chain and medium chain fatty acid portions,respectively,of PEG glyceryl esters in microemulsions.The cumulative amount of oil blue N in lymph fluid was almost the same between the two microemulsions,although the transferred amount of oil component(triglyceride)in the lymph after administration of the Gelucire®50/13 microemulsion was significantly higher than that of the Gelucire®44/14 microemulsion.On the other hand,the solubility of oil blue N in Gelucire®44/14 was much higher than that in Gelucire®50/13.No significant differences were observed between microemulsions in the bioavailability of oil blue N.From these data,the partitioning of oil blue N to the lymph was calculated using a mathematical model,showing that the partitioning ratios of oil blue N to the lymph fluid were almost the same for both microemulsions.The solubility of oil blue N to the oil component of the microemulsions and the transfer of triglycerides to the lymph after administration of the microemulsions counteract each other,leading to similar partitioning ratios of oil blue N to the lymph.展开更多
Tokamak exhaust is an important part of the deuterium-tritium fuel cycle system in fusion reactions.In this work,we present a laser-induced breakdown spectroscopy(LIBS)-based method to monitor the gas compositions fro...Tokamak exhaust is an important part of the deuterium-tritium fuel cycle system in fusion reactions.In this work,we present a laser-induced breakdown spectroscopy(LIBS)-based method to monitor the gas compositions from the exhaust system in the tokamak device.Helium(He),a main impurity in the exhaust gas,was mixed with hydrogen(H_(2))in different ratios through a self-designed gas distribution system,and sealed into a measurement chamber as a standard specimen.A 532 nm wavelength laser pulse with an output power of 100 mJ was used for plasma excitation.The time-resolved LIBS is used to study the time evolution characteristics of the signal strength,signal-to-background ratio(SBR),signal-to-noise ratio(SNR)and relative standard deviation(RSD)of the helium and hydrogen characteristic lines.The Boltzmann twoline method was employed to estimate the plasma temperature of laser-induced plasma(LIP).The Stark-broadened profile of He I 587.56 nm was exploited to measure the electron density.From these studies,an appropriate time was determined in which the low RSD%was consistent with the high signal-to-noise ratio.The He I 587.56 nm and Hαemission lines with good signalto-noise ratio were extracted from the spectrum and used in the external standard method and internal standard method for quantitative analysis.The test results for mixed gas showed that the average relative error of prediction was less than 11.15%,demonstrating the great potential of LIBS in detecting impurities in plasma exhaust gas.展开更多
In recent years, the X\|ray spectrometer has been developed not only just in enhancing resolution, but also towards dynamic analysis, computer modeling processing, sampled quantitative analysis and supra\|light elemen...In recent years, the X\|ray spectrometer has been developed not only just in enhancing resolution, but also towards dynamic analysis, computer modeling processing, sampled quantitative analysis and supra\|light element analysis. With the gradual sophistication of the quantitative analysis system software, the rationality and accuracy of the established sample deferential document have become the most important guarantee to the reliability of sample quantitative analysis. This work is an important technical subject in China Petroleum Reservoir Research. Through two years of research and experimental work, the EDS quantitative analysis method for petroleum geology and reservoir research has been established, and referential documents for five mineral (silicate, etc.) specimen standards have been compiled. Closely combining the shape characters and compositional characters of the minerals together and applying them into reservoir diagenetic research and prevention of oil formations from damage, we have obtained obvious geological effects.展开更多
pH is one of the significant properties of soil,and is closely related to the decomposition of soil organic matter,anion-cation balance,growth of plants and many other soil processes.In the present work,laser-induced ...pH is one of the significant properties of soil,and is closely related to the decomposition of soil organic matter,anion-cation balance,growth of plants and many other soil processes.In the present work,laser-induced breakdown spectroscopy(LIBS) technique coupled with random forest(RF) was proposed to quantify the pH of soil.First,LIBS spectra of soil was collected,and some common elements in soil were identified based on the National Institute of Science and Technology database.Then,in order to obtain a better predictive result,the influence of different input variables(full spectrum,different spectral ranges,the intensity of characteristic bands and characteristic lines) on the predictive performance of RF calibration model was explored with the evaluation indicators of root mean square error(RMSE) and coefficient of determination(R2),the characteristic bands of four elements(AI,Ca,Mg and Si) were determined as the optimal input variables.Finally,the predictive performance of RF calibration model was compared with partial least squares calibration model with the optimal input variables and model parameters,and RF calibration model showed a better predictive performance,and the four evaluation indicators of R_p^2,RMSEP,mean absolute error and mean relative error were 0.9687,0.1285,0.1114 and 0.0136,respectively.It indicates that LIBS technique coupled with RF algorithm is an effective method for pH determination of soil.展开更多
Background: Observation is an important skill for making appropriate nursing decisions and engaging in good practice. However, experts’ observation behavior and cognitive processes cannot be easily verbalized or docu...Background: Observation is an important skill for making appropriate nursing decisions and engaging in good practice. However, experts’ observation behavior and cognitive processes cannot be easily verbalized or documented in an objective and accurate manner. Quantitative analysis of the observation behavior of nurses with rich clinical experience will yield effective educational data for fostering and improving nursing students’ observation skills. Objectives: To improve nursing assessment education, the differences in the information gathering processes between clinical nurses and nursing students were analyzed by using a portable eye-tracker. Design: An experimental study. Settings: The experiment was performed at a university in Japan. Participants: The participants were 11 clinical nurses with at least 5 years of clinical experience for postoperative patients, and 10 fourth-year nursing students. Methods: In a mock hospital room, wherein we recreated a situation where a patient in postoperative day 1 was confined to a bed, participants wore an eye-tracking camera and engaged in nursing observation to make an early postoperative ambulation assessment of the patient. Participants’ gaze points and gaze fixation durations were extracted from the gaze measurement data and compared. Results: Clinical nurses had shorter observation times and gaze durations than did nursing students, and focused more on the patient chart, intravenous drip, and indwelling drain. Students gazed for longest at the measuring devices for vital signs. Conclusions: We quantitatively analyzed differences in nursing observation according to clinical experience. Although no significant difference was found in gaze points, nursing students had a greater tendency to focus on information that was numerically displayed. Nurses with clinical experience conducted observations by gazing at information that they needed to focus on the most according to the patients’ postoperative course.展开更多
Broken gangue has been extensively used in rockfill dams,subgrade,embankment,foundation cushion and other engineering construction.The deformation characteristics of broken gangue under the bearing compression play a ...Broken gangue has been extensively used in rockfill dams,subgrade,embankment,foundation cushion and other engineering construction.The deformation characteristics of broken gangue under the bearing compression play a decisive role in the firmness,stability and safety of these structures(buildings),and the meso-fabric change of broken gangue under the bearing compression significantly affects its macro deformation.In this study,the transparent characterization and quantitative analysis of 3D fabric of broken gangue under the bearing compression were performed through CT scanning test,image processing and 3D reconstruction technology,and the influence mechanism of internal fabric of broken gangue on its macro deformation was revealed.The results show that:In the loading stage of 0–2 MPa,the sharp corners,thin edges on the blocks and the bar-shaped and blade-shaped blocks with poor regularity are broken first under the bearing compression;in the loading stage of 2–8 MPa,a large number of larger particles in the sample are crushed in the mode of fragmentation;in the loading stage of 8–10 MPa,the breakage degree of samples is relieved.The axial displacement of the block inside the sample occurs,as well as the lateral displacement of the block converging to the central axis of the sample.In the rapid deformation stage,the macro deformation of the broken gangue is mainly caused by the rearrangement and adjustment of the block structure and the breakage of the block;in the slow deformation stage,it is mainly caused by the breakage of the block;in the stable deformation stage,it is mainly caused by the optimization and adjustment of the bearing skeleton in the sample.展开更多
Cordycepin,which has great immunomodulatory activities such as anticancer,antifungal,antivirus,antileukemia and lipid-lowering ones,is the secondary metabolite of Cordyceps militaris(C.militaris).Liquid submerged ferm...Cordycepin,which has great immunomodulatory activities such as anticancer,antifungal,antivirus,antileukemia and lipid-lowering ones,is the secondary metabolite of Cordyceps militaris(C.militaris).Liquid submerged fermentation is the common cultivation process to produce cordycepin.To optimize the fermentation process and improve production,monitoring the cordycepin secretion in the fermentation is essential.The measurement based on chromatography-mass spectrometry methods is generally involved in the complex sample pretreatments and time-consuming separation,so more rapid and convenient methods are required.Matrix-assisted laser desorption ionization mass spectrometry(MALDI-MS)is more attractive for faster and direct detection.Therefore,MALDI-MS detection combined with isotope-labeled internal standard was applied to the measurement of cordycepin content in the fermentation broth and mycelium.This method made accurate quantification of cordycepin in the range of 5-400μg/mL with a relative standard deviation of 5.6%.The recovery rates of fermentation samples after the 1,13,and 25 days were 90.15%,94.27%,and 95.06%,respectively.The contents of cordycepin in the mycelium and fermentation broth were 136 mg/g and 148.39 mg/mL on the 20 th culture day,respectively.The cordycepin secretion curve of the liquid fermentation of C.militaris was real-time traced over 25 days.展开更多
The concentrations of SiO,Al2O,KO,NaO,CaO,MgO,Fe2Oand TiO,and loss on ignition(L.O.I.) are the main inorganic components of geological samples.Concentrations of the eight oxides and L.O.I.are also the main indicators ...The concentrations of SiO,Al2O,KO,NaO,CaO,MgO,Fe2Oand TiO,and loss on ignition(L.O.I.) are the main inorganic components of geological samples.Concentrations of the eight oxides and L.O.I.are also the main indicators of concern in the production of building ceramics.Quantitative analysis of the eight oxides and L.O.I.was performed using fiber-laserbased laser-induced breakdown spectroscopy(LIBS).A combination of continuous background deduction,full width at half maximum(FWHM) intensity integral and spectral sum normalization was proposed for data processing.After the data processing combined the continuous background deduction,FWHM intensity integral and spectral sum normalization,the mean absolute errors(MAEs) of the calibration of L.O.I.,SiO,Al2O,KO,NaO,CaO,MgO,Fe2Oand TiOwas reduced from 2.03%,12.06%,4.84%,1.10%,0.69%,0.31%,0.11%,0.20%and 0.10% to 1.80%,9.48%,2.12%,0.36%,0.58%,0.11%,0.08%,0.19% and 0.05%,respectively.This multivariate method was further introduced and discussed to improve the analysis performance.The MAEs of L.O.I.,SiO,Al2O,KO and NaO were further reduced to1.12%,2.07%,1.38%,0.35% and 0.43%,respectively.The results show that the overall prediction error can meet the requirements for the production of building ceramics.The LIBS desktop analyzer has great potential in detection applications on geological samples.展开更多
Contact force in a clearance joint affects the dynamic characteristics and leads to nonlinear response of the mechanism.It is necessary to assess the nonlinearity of contact force quantitatively.Therefore,a new method...Contact force in a clearance joint affects the dynamic characteristics and leads to nonlinear response of the mechanism.It is necessary to assess the nonlinearity of contact force quantitatively.Therefore,a new method named contact-force entropy weight is proposed in this paper.This method presents a comprehensive description of the judgment matrix in the X,Y,and Z directions.To assess the influence degrees of different clearances and angular velocities on the contact force,the method is applied to numerical calculation and simulation of a six-bar mechanism with a clearance joint to illustrate its application and investigate the influence degree of angular velocity and clearance on the contact force.By combining the simulation results and theoretical calculations,the influence degrees of different clearances and angular velocities on the contact-force entropy weight of the six-bar mechanism with a clearance joint are revealed.It is found that the angular velocity has a significant influence on the contact force entropy weight of the clearance joint,showing that the contact-force entropy weight is a feasible new method of assessing non-linearity of contact force quantitatively.The method gives a theoretical reference for quantitatively analyzing the nonlinear dynamics.展开更多
Laser-induced breakdown spectroscopy(LIBS)has been applied to many fields for the quantitative analysis of diverse materials.Improving the prediction accuracy of LIBS regression models is still of great significance f...Laser-induced breakdown spectroscopy(LIBS)has been applied to many fields for the quantitative analysis of diverse materials.Improving the prediction accuracy of LIBS regression models is still of great significance for the Mars exploration in the near future.In this study,we explored the quantitative analysis of LIBS for the one-dimensional Chem Cam(an instrument containing a LIBS spectrometer and a Remote Micro-Imager)spectral data whose spectra are produced by the Chem Cam team using LIBS under the Mars-like atmospheric conditions.We constructed a convolutional neural network(CNN)regression model with unified parameters for all oxides,which is efficient and concise.CNN that has the excellent capability of feature extraction can effectively overcome the chemical matrix effects that impede the prediction accuracy of regression models.Firstly,we explored the effects of four activation functions on the performance of the CNN model.The results show that the CNN model with the hyperbolic tangent(tanh)function outperforms the CNN models with the other activation functions(the rectified linear unit function,the linear function and the Sigmoid function).Secondly,we compared the performance among the CNN models using different optimization methods.The CNN model with the stochastic gradient descent optimization and the initial learning rate?=?0.0005 achieves satisfactory performance compared to the other CNN models.Finally,we compared the performance of the CNN model,the model based on support vector regression(SVR)and the model based on partial least square regression(PLSR).The results exhibit the CNN model is superior to the SVR model and the PLSR model for all oxides.Based on the above analysis,we conclude the CNN regression model can effectively improve the prediction accuracy of LIBS.展开更多
1 Introduction The super-large Huize lead-zinc ore district is one of the most representative lead-zinc deposits in Northeastern Yunnan poly-metallic deposit concentration district.So far,studies(Liu and Lin,1999;Han ...1 Introduction The super-large Huize lead-zinc ore district is one of the most representative lead-zinc deposits in Northeastern Yunnan poly-metallic deposit concentration district.So far,studies(Liu and Lin,1999;Han et al.,2007)on the type of deposits like the Huize lead-zinc deposit,focused on deposit genesis,the sources of metallogenic materials,展开更多
In vivo imaging system (IVIS) is a new and rapidly expanding technology, which has a wide range of applications in life science such as cell tracing. By counting the number of photons emitted from a specimen, IVIS can...In vivo imaging system (IVIS) is a new and rapidly expanding technology, which has a wide range of applications in life science such as cell tracing. By counting the number of photons emitted from a specimen, IVIS can quantify biological events such as tumor growth. We used B16F10-luc-G5 tumor cells and 20 Babl/C mice injected subcutaneously with B16F10-luc-G5 tumor cells (1×106 in 100 μL) to develop a method to quantitatively analyze cells traced by IVIS in vitro and in vivo, respectively. The results showed a strong correlation between the number of tumor cells and the intensity of bioluminescence signal (R2=0.99) under different exposure conditions in in vitro assay. The results derived from the in vivo experiments showed that tumor luminescence was observed in all mice by IVIS at all days, and there was significant difference (P<0.01) between every two days from day 3 to day 14. Moreover, tumor dynamic morphology could be monitored by IVIS when it was in- visible. There was a strong correlation between tumor volume and bioluminescence signal (R2=0.97) by IVIS. In summary, we demonstrated a way to accurately carry out the quantitative analysis of cells using IVIS both in vitro and in vivo. The data indicate that IVIS can be used as an effective and quantitative method for cell tracing both in vitro and in vivo.展开更多
基金the financial support provided by the National Natural Science Foundation of China(Grant No.11872013).
文摘Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ synthesis method,including small size and low dosage,bring about difficulties in quantitative analysis and differences in ignition capabilities of CA chips.The aim of present work is to develop a simplified quantitative analysis method for accurate and safe analysis of components in CA chips to evaluate and investigate the corresponding ignition ability.In this work,Cu(N_(3))2 and CuN_(3)components in CA chips were separated through dissolution and distillation by utilizing the difference in solubility and corresponding content was obtained by measuring N_(3)-concentration through spectrophotometry.The spectrophotometry method was optimized by studying influencing factors and the recovery rate of different separation methods was studied,ensuring the accuracy and reproducibility of test results.The optimized method is linear in range from 1.0-25.0 mg/L,with a correlation coefficient R^(2)=0.9998,which meets the requirements of CA chips with a milligram-level content test.Compared with the existing ICP method,component analysis results of CA chips obtained by spectrophotometry are closer to real component content in samples and have satisfactory accuracy.Moreover,as its application in miniaturized explosive systems,the ignition ability of CA chips with different component contents for direct ink writing CL-20 and the corresponding mechanism was studied.This study provided a basis and idea for the design and performance evaluation of CA chips in miniaturized explosive systems.
基金funded by the National Natural Science Foundation of China(NSFC)the Chinese Academy of Sciences(CAS)(grant No.U2031209)the National Natural Science Foundation of China(NSFC,grant Nos.11872128,42174192,and 91952111)。
文摘Seeing is an important index to evaluate the quality of an astronomical site.To estimate seeing at the Muztagh-Ata site with height and time quantitatively,the European Centre for Medium-Range Weather Forecasts reanalysis database(ERA5)is used.Seeing calculated from ERA5 is compared consistently with the Differential Image Motion Monitor seeing at the height of 12 m.Results show that seeing decays exponentially with height at the Muztagh-Ata site.Seeing decays the fastest in fall in 2021 and most slowly with height in summer.The seeing condition is better in fall than in summer.The median value of seeing at 12 m is 0.89 arcsec,the maximum value is1.21 arcsec in August and the minimum is 0.66 arcsec in October.The median value of seeing at 12 m is 0.72arcsec in the nighttime and 1.08 arcsec in the daytime.Seeing is a combination of annual and about biannual variations with the same phase as temperature and wind speed indicating that seeing variation with time is influenced by temperature and wind speed.The Richardson number Ri is used to analyze the atmospheric stability and the variations of seeing are consistent with Ri between layers.These quantitative results can provide an important reference for a telescopic observation strategy.
基金financially supported by the Provincial Key Research and Development Program of Shandong,China(No.2019GHZ010)the Natural Science Foundation of Shandong Province(No.ZR2020MF123)+1 种基金National Natural Science Foundation of China(Nos.61975190 and12174359)the Fundamental Research Funds for the Central Universities(No.202161002)。
文摘Laser-induced breakdown spectroscopy(LIBS)is a capable technique for elementary analysis,while LIBS quantitation is still under development.In quantitation,precise laser focusing plays an important role because it ensures the distance between the laser and samples.In the present work,we employed spectral intensity as a direct way to assist laser focusing in LIBS quantitation for copper alloys.It is found that both the air emission and the copper line could be used to determine the position of the sample surface by referencing the intensity maximum.Nevertheless,the fine quantitation was only realized at the position where the air emission(e.g.O(I)777.4 nm)reached intensity maximum,and also in this way,a repeatable quantitation was successfully achieved even after 120 days.The results suggested that the LIBS quantitation was highly dependent on the focusing position of the laser,and spectra-assisted focusing could be a simple way to find the identical condition for different samples’detection.In the future,this method might be applicable in field measurements for LIBS analysis of solids.
基金Funded by the International Science&Technology Cooperation Program of Hubei Province of China(No.2022EHB024)。
文摘To explore ways to improve the accuracy of quantitative analysis of samples in the micrometer to nanometer range of magnitudes,we adopted analytical transmission electron microscopy(AEM/EDS)for qualitative and quantitative analysis of pyrite materials.Additionally,the k factor of pyrite is calculated experimentally.To develop an appropriate non-standard quantitative analysis model for pyrite materials,the experimentally calculated k factor is compared with that estimated from the non-standard quantitative analytical model of the instrument software.The experimental findings demonstrate that the EDS attached to a TEM can be employed for precise quantitative analysis of micro-and nanoscale regions of pyrite materials.Furthermore,it serves as a reference for improving the results of the EDS quantitative analysis of other sulfides.
基金Supported by National Natural Science Foundation of China,No.82172628。
文摘BACKGROUND Donor-recipient size mismatch(DRSM)is considered a crucial factor for poor outcomes in liver transplantation(LT)because of complications,such as massive intraoperative blood loss(IBL)and early allograft dysfunction(EAD).Liver volumetry is performed routinely in living donor LT,but rarely in deceased donor LT(DDLT),which amplifies the adverse effects of DRSM in DDLT.Due to the various shortcomings of traditional manual liver volumetry and formula methods,a feasible model based on intelligent/interactive qualitative and quantitative analysis-three-dimensional(IQQA-3D)for estimating the degree of DRSM is needed.AIM To identify benefits of IQQA-3D liver volumetry in DDLT and establish an estimation model to guide perioperative management.METHODS We retrospectively determined the accuracy of IQQA-3D liver volumetry for standard total liver volume(TLV)(sTLV)and established an estimation TLV(eTLV)index(eTLVi)model.Receiver operating characteristic(ROC)curves were drawn to detect the optimal cut-off values for predicting massive IBL and EAD in DDLT using donor sTLV to recipient sTLV(called sTLVi).The factors influencing the occurrence of massive IBL and EAD were explored through logistic regression analysis.Finally,the eTLVi model was compared with the sTLVi model through the ROC curve for verification.RESULTS A total of 133 patients were included in the analysis.The Changzheng formula was accurate for calculating donor sTLV(P=0.083)but not for recipient sTLV(P=0.036).Recipient eTLV calculated using IQQA-3D highly matched with recipient sTLV(P=0.221).Alcoholic liver disease,gastrointestinal bleeding,and sTLVi>1.24 were independent risk factors for massive IBL,and drug-induced liver failure was an independent protective factor for massive IBL.Male donor-female recipient combination,model for end-stage liver disease score,sTLVi≤0.85,and sTLVi≥1.32 were independent risk factors for EAD,and viral hepatitis was an independent protective factor for EAD.The overall survival of patients in the 0.85<sTLVi<1.32 group was better compared to the sTLVi≤0.85 group and sTLVi≥1.32 group(P<0.001).There was no statistically significant difference in the area under the curve of the sTLVi model and IQQA-3D eTLVi model in the detection of massive IBL and EAD(all P>0.05).CONCLUSION IQQA-3D eTLVi model has high accuracy in predicting massive IBL and EAD in DDLT.We should follow the guidance of the IQQA-3D eTLVi model in perioperative management.
基金Project supported by the Natural Science Foundation of Beijing Municipality (Grant No.1212007)the National Natural Science Foundation of China (Grant No.11705284)the Open Project Program of State Key Laboratory of Petroleum Resources and Prospecting,China University of Petroleum (Grant No.PRP/DX-2211)。
文摘We make a quantitative study on the soliton interactions in the nonlinear Schro¨dinger equation(NLSE) and its variable–coefficient(vc) counterpart. For the regular two-soliton and double-pole solutions of the NLSE, we employ the asymptotic analysis method to obtain the expressions of asymptotic solitons, and analyze the interaction properties based on the soliton physical quantities(especially the soliton accelerations and interaction forces);whereas for the bounded two-soliton solution, we numerically calculate the soliton center positions and accelerations, and discuss the soliton interaction scenarios in three typical bounded cases. Via some variable transformations, we also obtain the inhomogeneous regular two-soliton and double-pole solutions for the vcNLSE with an integrable condition. Based on the expressions of asymptotic solitons, we quantitatively study the two-soliton interactions with some inhomogeneous dispersion profiles,particularly discuss the influence of the variable dispersion function f(t) on the soliton interaction dynamics.
基金supported by the Japan Society for the Promotion of Science under KAKENHI Grant Nos.19F19379 and 20H04199。
文摘This paper demonstrates the importance of three-dimensional(3-D)piezoelectric coupling in the electromechanical behavior of piezoelectric devices using three-dimensional finite element analyses based on weak and strong coupling models for a thin cantilevered piezoelectric bimorph actuator.It is found that there is a significant difference between the strong and weak coupling solutions given by coupling direct and inverse piezoelectric effects(i.e.,piezoelectric coupling effect).In addition,there is significant longitudinal bending caused by the constraint of the inverse piezoelectric effect in the width direction at the fixed end(i.e.,3-D effect).Hence,modeling of these effects or 3-D piezoelectric coupling modeling is an electromechanical basis for the piezoelectric devices,which contributes to the accurate prediction of their behavior.
基金supported by National Key Research and Development Program of China(No.2016YFF0102502)the Key Research Program of Frontier Sciences,CAS(No.QYZDJ-SSW-JSC037)the Youth Innovation Promotion Association,CAS,Liao Ning Revitalization Talents Program(No.XLYC1807110)。
文摘In the spectral analysis of laser-induced breakdown spectroscopy,abundant characteristic spectral lines and severe interference information exist simultaneously in the original spectral data.Here,a feature selection method called recursive feature elimination based on ridge regression(Ridge-RFE)for the original spectral data is recommended to make full use of the valid information of spectra.In the Ridge-RFE method,the absolute value of the ridge regression coefficient was used as a criterion to screen spectral characteristic,the feature with the absolute value of minimum weight in the input subset features was removed by recursive feature elimination(RFE),and the selected features were used as inputs of the partial least squares regression(PLS)model.The Ridge-RFE method based PLS model was used to measure the Fe,Si,Mg,Cu,Zn and Mn for 51 aluminum alloy samples,and the results showed that the root mean square error of prediction decreased greatly compared to the PLS model with full spectrum as input.The overall results demonstrate that the Ridge-RFE method is more efficient to extract the redundant features,make PLS model for better quantitative analysis results and improve model generalization ability.
文摘The purpose of this study was to quantify the effect of the fatty acid alkyl-chain length of a polyethylene glycol(PEG)glyceryl ester,which was used as a microemulsion oil component,on the partitioning of highly lipophilic compounds to the mesenteric lymph after oral administration.Oil blue N,a highly lipophilic anthraquinone derivative,was orally administered to lymph duct-cannulated and untreated rats in two kinds of different microemulsions.Gelucire®50/13 and Gelucire®44/14 were used as the oil component with long chain and medium chain fatty acid portions,respectively,of PEG glyceryl esters in microemulsions.The cumulative amount of oil blue N in lymph fluid was almost the same between the two microemulsions,although the transferred amount of oil component(triglyceride)in the lymph after administration of the Gelucire®50/13 microemulsion was significantly higher than that of the Gelucire®44/14 microemulsion.On the other hand,the solubility of oil blue N in Gelucire®44/14 was much higher than that in Gelucire®50/13.No significant differences were observed between microemulsions in the bioavailability of oil blue N.From these data,the partitioning of oil blue N to the lymph was calculated using a mathematical model,showing that the partitioning ratios of oil blue N to the lymph fluid were almost the same for both microemulsions.The solubility of oil blue N to the oil component of the microemulsions and the transfer of triglycerides to the lymph after administration of the microemulsions counteract each other,leading to similar partitioning ratios of oil blue N to the lymph.
基金supported by the National Key R&D Program of China(Nos.2017YFE0301506 and 2017YFE0301306)。
文摘Tokamak exhaust is an important part of the deuterium-tritium fuel cycle system in fusion reactions.In this work,we present a laser-induced breakdown spectroscopy(LIBS)-based method to monitor the gas compositions from the exhaust system in the tokamak device.Helium(He),a main impurity in the exhaust gas,was mixed with hydrogen(H_(2))in different ratios through a self-designed gas distribution system,and sealed into a measurement chamber as a standard specimen.A 532 nm wavelength laser pulse with an output power of 100 mJ was used for plasma excitation.The time-resolved LIBS is used to study the time evolution characteristics of the signal strength,signal-to-background ratio(SBR),signal-to-noise ratio(SNR)and relative standard deviation(RSD)of the helium and hydrogen characteristic lines.The Boltzmann twoline method was employed to estimate the plasma temperature of laser-induced plasma(LIP).The Stark-broadened profile of He I 587.56 nm was exploited to measure the electron density.From these studies,an appropriate time was determined in which the low RSD%was consistent with the high signal-to-noise ratio.The He I 587.56 nm and Hαemission lines with good signalto-noise ratio were extracted from the spectrum and used in the external standard method and internal standard method for quantitative analysis.The test results for mixed gas showed that the average relative error of prediction was less than 11.15%,demonstrating the great potential of LIBS in detecting impurities in plasma exhaust gas.
文摘In recent years, the X\|ray spectrometer has been developed not only just in enhancing resolution, but also towards dynamic analysis, computer modeling processing, sampled quantitative analysis and supra\|light element analysis. With the gradual sophistication of the quantitative analysis system software, the rationality and accuracy of the established sample deferential document have become the most important guarantee to the reliability of sample quantitative analysis. This work is an important technical subject in China Petroleum Reservoir Research. Through two years of research and experimental work, the EDS quantitative analysis method for petroleum geology and reservoir research has been established, and referential documents for five mineral (silicate, etc.) specimen standards have been compiled. Closely combining the shape characters and compositional characters of the minerals together and applying them into reservoir diagenetic research and prevention of oil formations from damage, we have obtained obvious geological effects.
基金support of National Natural Science Foundation of China(Nos.21873076,21675123,21605123,21375105)Natural Science Basic Research Plan in Shaanxi Province of China(No.2018JQ2013)Scientific Research Plan Projects of Shaanxi Education Department(No.17JK0780)。
文摘pH is one of the significant properties of soil,and is closely related to the decomposition of soil organic matter,anion-cation balance,growth of plants and many other soil processes.In the present work,laser-induced breakdown spectroscopy(LIBS) technique coupled with random forest(RF) was proposed to quantify the pH of soil.First,LIBS spectra of soil was collected,and some common elements in soil were identified based on the National Institute of Science and Technology database.Then,in order to obtain a better predictive result,the influence of different input variables(full spectrum,different spectral ranges,the intensity of characteristic bands and characteristic lines) on the predictive performance of RF calibration model was explored with the evaluation indicators of root mean square error(RMSE) and coefficient of determination(R2),the characteristic bands of four elements(AI,Ca,Mg and Si) were determined as the optimal input variables.Finally,the predictive performance of RF calibration model was compared with partial least squares calibration model with the optimal input variables and model parameters,and RF calibration model showed a better predictive performance,and the four evaluation indicators of R_p^2,RMSEP,mean absolute error and mean relative error were 0.9687,0.1285,0.1114 and 0.0136,respectively.It indicates that LIBS technique coupled with RF algorithm is an effective method for pH determination of soil.
文摘Background: Observation is an important skill for making appropriate nursing decisions and engaging in good practice. However, experts’ observation behavior and cognitive processes cannot be easily verbalized or documented in an objective and accurate manner. Quantitative analysis of the observation behavior of nurses with rich clinical experience will yield effective educational data for fostering and improving nursing students’ observation skills. Objectives: To improve nursing assessment education, the differences in the information gathering processes between clinical nurses and nursing students were analyzed by using a portable eye-tracker. Design: An experimental study. Settings: The experiment was performed at a university in Japan. Participants: The participants were 11 clinical nurses with at least 5 years of clinical experience for postoperative patients, and 10 fourth-year nursing students. Methods: In a mock hospital room, wherein we recreated a situation where a patient in postoperative day 1 was confined to a bed, participants wore an eye-tracking camera and engaged in nursing observation to make an early postoperative ambulation assessment of the patient. Participants’ gaze points and gaze fixation durations were extracted from the gaze measurement data and compared. Results: Clinical nurses had shorter observation times and gaze durations than did nursing students, and focused more on the patient chart, intravenous drip, and indwelling drain. Students gazed for longest at the measuring devices for vital signs. Conclusions: We quantitatively analyzed differences in nursing observation according to clinical experience. Although no significant difference was found in gaze points, nursing students had a greater tendency to focus on information that was numerically displayed. Nurses with clinical experience conducted observations by gazing at information that they needed to focus on the most according to the patients’ postoperative course.
基金supported by the National Natural Science Foundation of China(Nos.52104103,52022107,52174128)the Natural Science Foundation of Jiangsu Province(Nos.BK20210499,BK20190031)。
文摘Broken gangue has been extensively used in rockfill dams,subgrade,embankment,foundation cushion and other engineering construction.The deformation characteristics of broken gangue under the bearing compression play a decisive role in the firmness,stability and safety of these structures(buildings),and the meso-fabric change of broken gangue under the bearing compression significantly affects its macro deformation.In this study,the transparent characterization and quantitative analysis of 3D fabric of broken gangue under the bearing compression were performed through CT scanning test,image processing and 3D reconstruction technology,and the influence mechanism of internal fabric of broken gangue on its macro deformation was revealed.The results show that:In the loading stage of 0–2 MPa,the sharp corners,thin edges on the blocks and the bar-shaped and blade-shaped blocks with poor regularity are broken first under the bearing compression;in the loading stage of 2–8 MPa,a large number of larger particles in the sample are crushed in the mode of fragmentation;in the loading stage of 8–10 MPa,the breakage degree of samples is relieved.The axial displacement of the block inside the sample occurs,as well as the lateral displacement of the block converging to the central axis of the sample.In the rapid deformation stage,the macro deformation of the broken gangue is mainly caused by the rearrangement and adjustment of the block structure and the breakage of the block;in the slow deformation stage,it is mainly caused by the breakage of the block;in the stable deformation stage,it is mainly caused by the optimization and adjustment of the bearing skeleton in the sample.
基金financially supported by Fundamental Research Funds for the Central Universities(Grant No.2019ZY31)the National Natural Science Foundation of China(Grant Nos.21775086 and 31770110)。
文摘Cordycepin,which has great immunomodulatory activities such as anticancer,antifungal,antivirus,antileukemia and lipid-lowering ones,is the secondary metabolite of Cordyceps militaris(C.militaris).Liquid submerged fermentation is the common cultivation process to produce cordycepin.To optimize the fermentation process and improve production,monitoring the cordycepin secretion in the fermentation is essential.The measurement based on chromatography-mass spectrometry methods is generally involved in the complex sample pretreatments and time-consuming separation,so more rapid and convenient methods are required.Matrix-assisted laser desorption ionization mass spectrometry(MALDI-MS)is more attractive for faster and direct detection.Therefore,MALDI-MS detection combined with isotope-labeled internal standard was applied to the measurement of cordycepin content in the fermentation broth and mycelium.This method made accurate quantification of cordycepin in the range of 5-400μg/mL with a relative standard deviation of 5.6%.The recovery rates of fermentation samples after the 1,13,and 25 days were 90.15%,94.27%,and 95.06%,respectively.The contents of cordycepin in the mycelium and fermentation broth were 136 mg/g and 148.39 mg/mL on the 20 th culture day,respectively.The cordycepin secretion curve of the liquid fermentation of C.militaris was real-time traced over 25 days.
基金supported by National Natural Science Foundation of China(No.62173321)the Key Research Program of Frontier Sciences,CAS(No.QYZDJ-SSW-JSC037)+2 种基金the Science and Technology Service Network Initiative Program,CAS(No.KFJ-STS-QYZD-2021-19-002)the Liaoning Provincial Natural Science Foundation(No.2021-BS-022)the Youth Innovation Promotion Association,CAS。
文摘The concentrations of SiO,Al2O,KO,NaO,CaO,MgO,Fe2Oand TiO,and loss on ignition(L.O.I.) are the main inorganic components of geological samples.Concentrations of the eight oxides and L.O.I.are also the main indicators of concern in the production of building ceramics.Quantitative analysis of the eight oxides and L.O.I.was performed using fiber-laserbased laser-induced breakdown spectroscopy(LIBS).A combination of continuous background deduction,full width at half maximum(FWHM) intensity integral and spectral sum normalization was proposed for data processing.After the data processing combined the continuous background deduction,FWHM intensity integral and spectral sum normalization,the mean absolute errors(MAEs) of the calibration of L.O.I.,SiO,Al2O,KO,NaO,CaO,MgO,Fe2Oand TiOwas reduced from 2.03%,12.06%,4.84%,1.10%,0.69%,0.31%,0.11%,0.20%and 0.10% to 1.80%,9.48%,2.12%,0.36%,0.58%,0.11%,0.08%,0.19% and 0.05%,respectively.This multivariate method was further introduced and discussed to improve the analysis performance.The MAEs of L.O.I.,SiO,Al2O,KO and NaO were further reduced to1.12%,2.07%,1.38%,0.35% and 0.43%,respectively.The results show that the overall prediction error can meet the requirements for the production of building ceramics.The LIBS desktop analyzer has great potential in detection applications on geological samples.
基金Project supported by the National Natural Science Foundation of China(Grant No.51875531)。
文摘Contact force in a clearance joint affects the dynamic characteristics and leads to nonlinear response of the mechanism.It is necessary to assess the nonlinearity of contact force quantitatively.Therefore,a new method named contact-force entropy weight is proposed in this paper.This method presents a comprehensive description of the judgment matrix in the X,Y,and Z directions.To assess the influence degrees of different clearances and angular velocities on the contact force,the method is applied to numerical calculation and simulation of a six-bar mechanism with a clearance joint to illustrate its application and investigate the influence degree of angular velocity and clearance on the contact force.By combining the simulation results and theoretical calculations,the influence degrees of different clearances and angular velocities on the contact-force entropy weight of the six-bar mechanism with a clearance joint are revealed.It is found that the angular velocity has a significant influence on the contact force entropy weight of the clearance joint,showing that the contact-force entropy weight is a feasible new method of assessing non-linearity of contact force quantitatively.The method gives a theoretical reference for quantitatively analyzing the nonlinear dynamics.
基金supported by the Pre-research project on Civil Aerospace Technologies(No.D020102)funded by China National Space Administration(CNSA)the funding from National Natural Science Foundation of China(Nos.U1931211,41573056)+1 种基金the Natural Science Foundation of Shandong Province(No.ZR2019MD008)the Major Research Project of Shandong Province(No.GG201809130208)。
文摘Laser-induced breakdown spectroscopy(LIBS)has been applied to many fields for the quantitative analysis of diverse materials.Improving the prediction accuracy of LIBS regression models is still of great significance for the Mars exploration in the near future.In this study,we explored the quantitative analysis of LIBS for the one-dimensional Chem Cam(an instrument containing a LIBS spectrometer and a Remote Micro-Imager)spectral data whose spectra are produced by the Chem Cam team using LIBS under the Mars-like atmospheric conditions.We constructed a convolutional neural network(CNN)regression model with unified parameters for all oxides,which is efficient and concise.CNN that has the excellent capability of feature extraction can effectively overcome the chemical matrix effects that impede the prediction accuracy of regression models.Firstly,we explored the effects of four activation functions on the performance of the CNN model.The results show that the CNN model with the hyperbolic tangent(tanh)function outperforms the CNN models with the other activation functions(the rectified linear unit function,the linear function and the Sigmoid function).Secondly,we compared the performance among the CNN models using different optimization methods.The CNN model with the stochastic gradient descent optimization and the initial learning rate?=?0.0005 achieves satisfactory performance compared to the other CNN models.Finally,we compared the performance of the CNN model,the model based on support vector regression(SVR)and the model based on partial least square regression(PLSR).The results exhibit the CNN model is superior to the SVR model and the PLSR model for all oxides.Based on the above analysis,we conclude the CNN regression model can effectively improve the prediction accuracy of LIBS.
基金supported by the Funds for the program of the National Natural Science Foundation (Noes. 41572060, U1133602)Projects of YM Lab (2011)Innovation Team of Yunnan province and KMUST (2008,2012)
文摘1 Introduction The super-large Huize lead-zinc ore district is one of the most representative lead-zinc deposits in Northeastern Yunnan poly-metallic deposit concentration district.So far,studies(Liu and Lin,1999;Han et al.,2007)on the type of deposits like the Huize lead-zinc deposit,focused on deposit genesis,the sources of metallogenic materials,
基金supported by a grant from the National Natural Sciences Foundation of China (No. 30901364)grants from the National Basic Research Program of China (No. 2003CB515505, 2009CB522407)
文摘In vivo imaging system (IVIS) is a new and rapidly expanding technology, which has a wide range of applications in life science such as cell tracing. By counting the number of photons emitted from a specimen, IVIS can quantify biological events such as tumor growth. We used B16F10-luc-G5 tumor cells and 20 Babl/C mice injected subcutaneously with B16F10-luc-G5 tumor cells (1×106 in 100 μL) to develop a method to quantitatively analyze cells traced by IVIS in vitro and in vivo, respectively. The results showed a strong correlation between the number of tumor cells and the intensity of bioluminescence signal (R2=0.99) under different exposure conditions in in vitro assay. The results derived from the in vivo experiments showed that tumor luminescence was observed in all mice by IVIS at all days, and there was significant difference (P<0.01) between every two days from day 3 to day 14. Moreover, tumor dynamic morphology could be monitored by IVIS when it was in- visible. There was a strong correlation between tumor volume and bioluminescence signal (R2=0.97) by IVIS. In summary, we demonstrated a way to accurately carry out the quantitative analysis of cells using IVIS both in vitro and in vivo. The data indicate that IVIS can be used as an effective and quantitative method for cell tracing both in vitro and in vivo.