期刊文献+
共找到18,046篇文章
< 1 2 250 >
每页显示 20 50 100
Can we predict the incidence of high-grade Clavien-Dindo complications in patients with forgotten encrusted stents undergoing endourologic management?
1
作者 Praanjal Gupta Ramanitharan Manikandan +3 位作者 Lalgudi Narayanan Dorairajan Kodakattil Sreenivasan Sreerag Sidhartha Kalra Swapnil Singh Kushwaha 《Asian Journal of Urology》 CSCD 2024年第1期99-104,共6页
Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to re... Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to report the complications in patients with forgotten and encrusted stents according to the Clavien-Dindo system specific to urological procedures and identify the factors leading to high-grade(Clavien-Dindo Grade 4A or above)complications.Methods:The hospital records of patients with forgotten encrusted double-J stents over a period of 8 years were reviewed.The parameters recorded included patient demographics,indwelling time,need for percutaneous nephrostomy,hemodialysis,urine culture,blood culture,total blood counts,serum creatinine,radiologic findings,management techniques,number of surgical interventions,modified Clavien-Dindo complications,follow-up,and mortality,if any.Results:Forty patients were included in the study.The median age was 52(range 6-85)years.Of the total,25(62.5%)patients had a“significant”stent load;31(77.5%)had renal failure or acute kidney injury on presentation;19(47.5%)patients had sepsis at presentation.Among the patients presented with sepsis,11(57.9%)patients demonstrated a positive urine culture;and 7/11(63.6%)patients exhibited pan-resistant organisms.Twelve out of 40(30.0%)patients in our series developed high-grade Clavien-Dindo complications.On univariate analysis,sepsis at presentation(p=0.007),stent load(p=0.031),diabetes(p=0.023),positive urine culture(p=0.007),and stent indwelling time of more than 1 year(p=0.031)were found to be significant.On multivariate logistic regression analysis,sepsis at presentation(p=0.017)and positive urine culture(p=0.016)were significant predictors for high-grade complications.Conclusion:It is prudent to identify specific risk factors,namely sepsis at presentation and positive urine culture to triage and optimize these patients before surgical management. 展开更多
关键词 Forgotten Encrusted stent Outcome PREDICTOR Clavien-Dindo complication
下载PDF
Numerical Study of the Biomechanical Behavior of a 3D Printed Polymer Esophageal Stent in the Esophagus by BP Neural Network Algorithm
2
作者 Guilin Wu Shenghua Huang +7 位作者 Tingting Liu Zhuoni Yang Yuesong Wu Guihong Wei Peng Yu Qilin Zhang Jun Feng Bo Zeng 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2709-2725,共17页
Esophageal disease is a common disorder of the digestive system that can severely affect the quality of life andprognosis of patients. Esophageal stenting is an effective treatment that has been widely used in clinica... Esophageal disease is a common disorder of the digestive system that can severely affect the quality of life andprognosis of patients. Esophageal stenting is an effective treatment that has been widely used in clinical practice.However, esophageal stents of different types and parameters have varying adaptability and effectiveness forpatients, and they need to be individually selected according to the patient’s specific situation. The purposeof this study was to provide a reference for clinical doctors to choose suitable esophageal stents. We used 3Dprinting technology to fabricate esophageal stents with different ratios of thermoplastic polyurethane (TPU)/(Poly-ε-caprolactone) PCL polymer, and established an artificial neural network model that could predict the radial forceof esophageal stents based on the content of TPU, PCL and print parameter. We selected three optimal ratios formechanical performance tests and evaluated the biomechanical effects of different ratios of stents on esophagealimplantation, swallowing, and stent migration processes through finite element numerical simulation and in vitrosimulation tests. The results showed that different ratios of polymer stents had different mechanical properties,affecting the effectiveness of stent expansion treatment and the possibility of postoperative complications of stentimplantation. 展开更多
关键词 Finite element method 3D printing polymer esophageal stent artificial neural network
下载PDF
Baerveldt glaucoma implant with Supramid© ripcord stent in neovascular glaucoma: a case series
3
作者 Yuen Keat Gan Shiivaa Manjare Birapadian +1 位作者 Muhammad Irfan Abdul Jalal Norshamsiah Md Din 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期265-271,共7页
AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripco... AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripcord stent in patients with NVG.No tube ligation or venting slits were performed.Supramid was removed after 3mo if the target intraocular pressure(IOP)was not achieved.Surgical success was defined as IOP≤21 mm Hg with(qualified success)or without IOP-lowering medications(complete success).RESULTS:Twenty-six eyes from 24 patients were included in the study.The median duration of follow-up was 4[interquartile range(IQR)=1-5]y,ranging from 0.5 to 5y.IOP decreased by a mean of 24.2 mm Hg(59.7%);from a mean of 40.5±12.6 mm Hg at baseline to 16.3±11.9 mm Hg,P≤0.001.The number of glaucoma medications reduced from a median of 5(IQR=5-6)to 1(IQR=0-2,P≤0.001)at the final follow-up.Overall success rates were 88.0%at 1y,34.8%at 3y,66.7%at 4y,and 50%at 5y.Hypertensive phase(HP)in the first 3mo occurred in 15/26 eyes(57.7%)with a mean IOP of 31.1 mm Hg.CONCLUSION:BGI with Supramid©ripcord stent gives close to 90%of the overall survival rate at the final follow-up without significant early hypotony.However,early HP is still a challenge. 展开更多
关键词 neovascular glaucoma Supramid ripcord stent Baerveldt glaucoma implant
原文传递
Endoscopic ultrasound-guided tissue sampling induced pancreatic duct leak resolved by the placement of a pancreatic stent:A case report
4
作者 Ki-Hyun Kim Chang Hwan Park +1 位作者 Eunae Cho Yohan Lee 《World Journal of Clinical Cases》 SCIE 2024年第9期1677-1684,共8页
BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and... BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and weight loss.Diagnosis:Laboratory findings revealed elevated carbohydrate antigen 19-9(5920 U/mL)and carcinoembryonic antigen(23.7 ng/mL)levels.Magnetic resonance imaging of the pancreas revealed an approximately 3 cm ill-defined space-occupying lesion in the inferior aspect of the head,with severe encasement of the superior mesenteric artery.Pancreatic ductal adenocarcinoma was confirmed after pathological examination of specimens obtained by EUS-TS using the fanning method.Interventions and outcomes:The following day,the patient experienced severe abdominal pain with high amylase(265 U/L)and lipase(1173 U/L)levels.Computed tomography of the abdomen revealed edematous wall thickening of the second portion of the duodenum with adjacent fluid collections and a suspicious leak from either the distal common bile duct or the main pancreatic duct in the head.Endoscopic retrograde cholangiopancreatography revealed dye leakage in the head of the main pancreatic duct.Therefore,a 5F 7 cm linear plastic stent was deployed into the pancreatic duct to divert the pancreatic juice.The patient’s abdominal pain improved immediately after pancreatic stent insertion,and amylase and lipase levels normalized within a week.Neoadjuvant chemotherapy was then initiated.CONCLUSION Using the fanning method in EUS-TS can inadvertently cause damage to the pancreatic duct and may lead to clinically significant pancreatitis.Placing a pancreatic stent may immediately resolve acute pancreatitis and shorten the waiting time for curative therapy.When using the fanning method during EUSTS,ductal structures should be excluded to prevent pancreatic ductal leakage. 展开更多
关键词 Endoscopic ultrasound-guided tissue sampling PANCREATITIS Pancreatic duct leak Pancreatic stent Case report
下载PDF
Two-Stent Strategy for Bifurcation Lesions in Percutaneous Transluminal Coronary Angioplasty: Real-World Evidence
5
作者 Dilip Kumar Amit Malviya +8 位作者 Animesh Mishra Rabin Chakraborty Sanjeev S. Mukherjee Soumya Patra Arindam Pande Rana Rathor Roy Debopriyo Mondal Ashesh Halder Sumit Shanker 《World Journal of Cardiovascular Diseases》 CAS 2024年第3期140-156,共17页
Background: Bifurcation lesions pose a high risk for adverse events after percutaneous coronary intervention (PCI). Evidence supporting the benefits of the two-stent strategy (2SS) for treating coronary bifurcation le... Background: Bifurcation lesions pose a high risk for adverse events after percutaneous coronary intervention (PCI). Evidence supporting the benefits of the two-stent strategy (2SS) for treating coronary bifurcation lesions in India is limited. This study aimed to evaluate the clinical outcomes of various 2SSs for percutaneous transluminal coronary angioplasty for bifurcation lesions in India. Materials and Methods: This retrospective, observational, multicentric, real-world study included 64 patients over 8 years. Data on demographics, medical history, PCI procedures, and outcomes were recorded. Descriptive statistics were computed using the SPSS software. Results: Patients (n = 64) had an average age of 65.3 ± 11.1 years, with 78.1% males. Acute coronary syndrome was reported in 18.8%, chronic stable angina in 40.6%, and unstable angina in 34.4% of participants. Two-vessel disease was observed in 98.4% of patients, and 99.4% had true bifurcation lesions. The commonly involved vessels were the left anterior descending artery (50%), left circumflex coronary artery (34.4%), and first diagonal artery (43.8%). Mean percent diameter stenosis was 87.2% ± 10.1%. The mean number of stents used was 2.00 ± 0.34. The 2SS techniques included the T and small protrusion (TAP) (39.1%), double kissing (DK) crush (18.8%), and the culotte techniques (14.1%). Procedural and angiographic success rate was 92.18%. Major adverse cardiovascular events at 1-year follow-up occurred in 7.8% of cases. Conclusion: The 2SS for bifurcation lesions showed favorable in-hospital and follow-up outcomes. Findings can serve as a resource for bifurcation angioplasty in India. Larger real-world studies with robust methodology are needed to validate these results. 展开更多
关键词 Bifurcation stenting Coronary Bifurcation Lesions PERCUTANEOUS
下载PDF
Endoscopic-ultrasound-guided biliary drainage with placement of electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction:Updated meta-analysis
6
作者 Zu-Xiang Peng Fang-Fang Chen +5 位作者 Wen Tang Xu Zeng Hong-Juan Du Ru-Xian Pi Hong-Ming Liu Xiao-Xiao Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期907-920,共14页
BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili... BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach. 展开更多
关键词 Biliary obstruction Biliary drainage Electrocautery-enhanced lumen-apposing metal stents Endoscopic ultrasound Endoscopic retrograde cholangiopancreatography failure
下载PDF
Transarterial chemoembolization plus stent placement for hepatocellular carcinoma with main portal vein tumor thrombosis:A meta-analysis
7
作者 Wei-Fan Sui Jian-Yun Li Jian-Hua Fu 《World Journal of Clinical Oncology》 2024年第3期447-455,共9页
BACKGROUND Portal vein tumor thrombus is an important indicator of poor prognosis in patients with hepatocellular carcinoma.Transarterial chemoembolization is recommended as the standard first-line therapy for unresec... BACKGROUND Portal vein tumor thrombus is an important indicator of poor prognosis in patients with hepatocellular carcinoma.Transarterial chemoembolization is recommended as the standard first-line therapy for unresectable hepatocellular carcinoma.Portal vein stent placement is a safe and effective therapy for promptly restoring flow and relieving portal hypertension caused by tumor thrombus.AIM To assess the clinical significance of transarterial chemoembolization plus stent placement for the treatment of hepatocellular carcinoma with main portal vein tumor thrombosis.METHODS We searched English and Chinese databases,assessed the quality of the included studies,analyzed the characteristic data,tested heterogeneity,explored heterogeneity,and tested publication bias.RESULTS In total,eight clinical controlled trials were included.The results showed that the pressure in the main portal vein after stent placement was significantly lower than that with no stent placement.The cumulative stent patency and survival rates at 6 and 12 months were lower in the transarterial chemoembolization+stent placement group than in the transarterial chemoembolization+stent placement+brachytherapy/radiotherapy group.The survival rates of patients treated with transarterial chemoembolization+stent placement for 6 and 12 months were higher than those of patients treated with transarterial chemoembolization alone.CONCLUSION For Chinese patients with hepatocellular carcinoma with main portal vein tumor thrombosis,transarterial chemoembolization plus stenting is effective.Transarterial chemoembolization+stent placement is more effective than transarterial chemoembolization alone.Transarterial chemoembolization+stent placement+brachytherapy/radiotherapy is more effective than transarterial chemoembolization+stenting. 展开更多
关键词 Hepatocellular carcinoma Transarterial chemoembolization Portal vein tumor thrombus stent META-ANALYSIS
下载PDF
Research on the Status Quo and Optimization of Centralized Procurement of Coronary Stents
8
作者 Zhang Yuting Liu Xiaoxi 《Asian Journal of Social Pharmacy》 2024年第1期20-28,共9页
Objective To study the impact of the first national centralized procurement of coronary stents on patients’psychology,the economy of medical institutions,and the survival and development of the coronary stents indust... Objective To study the impact of the first national centralized procurement of coronary stents on patients’psychology,the economy of medical institutions,and the survival and development of the coronary stents industry,and to provide suggestions on perfecting procedures to better carry out the centralized procurement of coronary stents.Methods Literature analysis was used to investigate the results of the procurement of coronary stent in a province and a hospital.Results and Conclusion The centralized procurement of coronary stents has alleviated the economic pressure of patients,but it has many problems.Therefore,this paper proposes some suggestions,such as promoting the orderly development of the coronary stent industry,improving the evaluation link of the centralized procurement of coronary stents,adopting the accurate reporting model to ensure the quality of coronary stents and improving the standardization of clinical services. 展开更多
关键词 volume procurement coronary stent medical resource
下载PDF
Effects of Continuous Precision Nursing Model on Knowledge, Attitudes, and Practices (KAP) Behavior and Cardiac Function in Patients after Percutaneous Coronary Angiography and Stent Implantation
9
作者 Cuiying Han 《Journal of Clinical and Nursing Research》 2024年第3期1-6,共6页
Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary a... Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary angiography and stent implantation.Methods:Ninety patients who underwent percutaneous coronary angiography and stent implantation in our hospital from April 2022 to April 2023 were selected and randomly divided into the control group(45 cases),in which routine nursing support was carried out during the treatment process,and the observation group(45 cases),in which continuous precision nursing model was carried out during the treatment process.Comparisons were made between the two groups of patients on their KAP,cardiac function,and quality of life during recovery.Results:There was no difference in the left ventricular ejection fraction(LVEF),cardiac output(CO),and cardiac index(CI)levels before intervention.After the intervention,the levels of cardiac function in the observation group were higher than those of the control group(P<0.05).There was no difference in the Exercise of Self-Care Agency(ESCA)self-care ability scale scores before the intervention.After the intervention,the observation group had higher ESCA scores than the control group(P<0.05).Conclusion:Implementation of a continuous precision nursing model in the care of patients undergoing percutaneous coronary angiography and stent implantation improved the patient’s cardiac function,and KAP,and promoted recovery. 展开更多
关键词 Continuous precision nursing model Percutaneous coronary angiography stent implantation Knowledge attitudes and practices(KAP) Cardiac function
下载PDF
Image-based visualization of stents in mechanical thrombectomy for acute ischemic stroke:Preliminary findings from a series of cases
10
作者 Qing-Yang Yao Mao-Lin Fu +3 位作者 Qing Zhao Xiao-Ming Zheng Kai Tang Li-Ming Cao 《World Journal of Clinical Cases》 SCIE 2023年第21期5047-5055,共9页
BACKGROUND Mechanical thrombectomy is the most effective treatment for great cerebral artery embolization within a set time window.Typically,an arteriogram does not show the localization of the stent after release and... BACKGROUND Mechanical thrombectomy is the most effective treatment for great cerebral artery embolization within a set time window.Typically,an arteriogram does not show the localization of the stent after release and whether a thrombus is captured or not.Thus,improving the visualization of a stent in interventional therapy will be helpful for clinicians.AIM To analyze stent imaging findings to enhance clinicians’understanding of a special circumstance,wherein a Solitaire AB retrievable stent was visible during the imaging of a thrombus capture that improved the success rate of stent-based mechanical thrombectomy.METHODS This was a retrospective study with four acute ischemic stroke(AIS)patients who underwent stent-based mechanical thrombectomy.RESULTS Patient 1 was a 64-year-old man admitted after 5 h of confusion;angiography revealed basilar artery occlusion.We inserted a stent into the left posterior cerebral artery-P2 segment and visualized the expanded stent that successfully captured a thrombus.Patient 2 was a 74-year-old man admitted with confusion,which lasted approximately 3 h.Angiography revealed a left middle cerebral artery(MCA)-M1 segment occlusion.A stent was deployed in the distal M2 segment,and we could visualize the stent by capturing the thrombus.Patient 3 was a 74-year-old woman admitted after experiencing left hemiplegia for 3 h.We deployed a stent at the distal right MCAM2 segment,and the developing stent captured a large thrombus.Patient 4 was an 82-year-old man who presented with confusion for 3 h.A developing stent was placed in the distal left MCA-M1 segment,which captured a large thrombus and several fragmented thrombi.CONCLUSION To the best of our knowledge,this is the first report of stent imaging in patients with AIS.We demonstrated the usefulness and substantial potential of stent imaging in stent-based mechanical thrombectomy for AIS. 展开更多
关键词 Digital subtraction angiography Solitaire AB stent Acute ischemic stroke stent-based mechanical thrombectomy Visualization of stents
下载PDF
Ultrasound-guided carotid angioplasty and stenting in a patient with iodinated contrast allergy:A case report 被引量:1
11
作者 Le Li Zi-Yan Wang Bo Liu 《World Journal of Clinical Cases》 SCIE 2023年第25期5926-5933,共8页
BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treati... BACKGROUND Ischemic stroke is an entity with high incidence,morbidity,and mortality rates.Carotid artery stenosis is an important and independent risk factor for ischemic stroke.The three current approaches for treating carotid artery stenosis are drug treatment,carotid endarterectomy(CEA),carotid angioplasty and stenting(CAS).The approach is chosen based on the degree of stenosis.CEA or CAS could have been chosen for the current patient,who had severe carotid stenosis and an iodinated contrast allergy.After thoroughly communicating with the patient,the patient chose CAS for treatment.Therefore,we performed ultrasound-guided CAS to avoid the use of iodinated contrast.CASE SUMMARY The main symptoms of the patient were numbness and weakness of the left limb.Computed tomography angiography of the head and neck at another hospital indicated multiple sites of stenosis in the arteries of the head and neck.The patient requested CAS for treatment but was allergic to iodinated contrast media.Thus,routine digital subtraction angiography(DSA)with iodinated contrast could not be used for the procedure.The diagnosis of this patient was as follows:(1)Right parietal lobe cerebral infarction;(2)multiple sites of stenosis in the arteries of the head and neck(severe stenosis of the right internal carotid artery,severe stenosis of the right subclavian artery);(3)right subclavian steal syndrome;and(4)hypertension(stage 3,high risk).The interventions included routine treatment for cerebral infarction,oral administration of clopidogrel(75 mg qd)and aspirin(100 mg qd),ultrasound-guided CAS,and postoperative follow-up.Postoperative color Doppler ultrasound and cerebrovascular magnetic resonance angiography of the carotid artery showed good vascular recovery,and the postoperative follow-up indicated a good prognosis.CONCLUSION This case study suggests that ultrasound-guided endovascular treatment is a potential option for patients with contraindications to the iodinated contrast agents used in DSA-guided surgery,although excellent surgical operating skills are needed. 展开更多
关键词 Iodinated contrast allergy ULTRASOUND-GUIDED Gadolinium-based contrast agent Carotid angioplasty and stenting Subclavian artery angioplasty and stenting Digital subtraction angiography Case report
下载PDF
Safety and efficacy of balloon angioplasty compared to stent-basedstrategies with pulmonary vein stenosis:A systematic review and meta-analysis
12
作者 Pradyumna Agasthi Srilekha Sridhara +14 位作者 Pattara Rattanawong Nithin Venepally Chieh-Ju Chao Hasan Ashraf Sai Harika Pujari Mohamed Allam Diana Almader-Douglas Yamini Alla Amit Kumar Farouk Mookadam Douglas L Packer David R Holmes Jr Donald J Hagler Floyd David Fortuin Reza Arsanjani 《World Journal of Cardiology》 2023年第2期64-75,共12页
BACKGROUND Pulmonary vein stenosis(PVS)is an uncommon but known cause of morbidity and mortality in adults and children and can be managed with percutaneous revascularization strategies of pulmonary vein balloon angio... BACKGROUND Pulmonary vein stenosis(PVS)is an uncommon but known cause of morbidity and mortality in adults and children and can be managed with percutaneous revascularization strategies of pulmonary vein balloon angioplasty(PBA)or pulmonary vein stent implantation(PSI).AIM To study the safety and efficacy outcomes of PBA vs PSI in all patient categories with PVS.METHODS We performed a literature search of all studies comparing outcomes of patients evaluated by PBA vs PSI for PVS.We selected all published studies comparing PBA vs PSI for PVS with reported outcomes of restenosis and procedure-related complications in all patient categories.In adults,PVS following atrial fibrillation ablation and in children PVS related to congenital etiology or post-procedural PVS following total or partial anomalous pulmonary venous return repair were included.The patient-centered outcomes were risk of restenosis requiring re-intervention and procedural-related complications.The metaanalysis was performed by computing odds ratios(ORs)using the random effects model based on underlying statistical heterogeneity.RESULTS Eight observational studies treating 768 severe PVS in 487 patients met our inclusion criteria.The age range of patients was 6 months to 70 years and 67%were males.The primary outcome of the re-stenosis requiring re-intervention occurred in 196 of 325 veins in the PBA group and 111 of 443 veins in the PSI group.Compared to PSI,PBA was associated with a significantly increased risk of re-stenosis(OR 2.91,95%CI:1.15-7.37,P=0.025,I2=79.2%).Secondary outcomes of the procedurerelated complications occurred in 7 of 122 patients in the PBA group and 6 of 69 in the PSI group.There were no statistically significant differences in the safety outcomes between the two groups(OR:0.94,95%CI:0.23-3.76,P=0.929,I^(2)=0.0%).CONCLUSION Across all patient categories with PVS,PSI is associated with reduced risk of re-intervention and is as safe as PBA and should be considered first-line therapy for PVS. 展开更多
关键词 Pulmonary veins Pulmonary vein stenosis CONSTRICTION Balloon angioplasty stentS Drugeluting stents
下载PDF
Commentary on a case report and literature review of acute carotid stent thrombosis
13
作者 Matthew Willman Brandon Lucke-Wold 《World Journal of Clinical Cases》 SCIE 2023年第7期1666-1668,共3页
In this commentary on the article entitled“Acute carotid stent thrombosis:A case report and literature review”,the key points of the article are discussed.Acute carotid stent thrombosis(ACST)in the setting of caroti... In this commentary on the article entitled“Acute carotid stent thrombosis:A case report and literature review”,the key points of the article are discussed.Acute carotid stent thrombosis(ACST)in the setting of carotid artery stenting(CAS)represents a rare but potentially catastrophic event.There is a wide range of treatment options available,including carotid endarterectomy,which is generally recommended for cases of refractory ACST.While there is no standard treatment regimen,dual antiplatelet therapy is typically recommended both before and after CAS to reduce risk of ACST. 展开更多
关键词 Acute carotid stent thrombosis Carotid artery stenting Carotid endarterectomy
下载PDF
Endoscopic luminal stenting:Current applications and future perspectives
14
作者 Miltiadis Moutzoukis Konstantinos Argyriou +1 位作者 Andreas Kapsoritakis Dimitrios Christodoulou 《World Journal of Gastrointestinal Endoscopy》 2023年第4期195-215,共21页
Endoscopic luminal stenting(ELS)represents a minimally invasive option for the management of malignant obstruction along the gastrointestinal tract.Previous studies have shown that ELS can provide rapid relief of symp... Endoscopic luminal stenting(ELS)represents a minimally invasive option for the management of malignant obstruction along the gastrointestinal tract.Previous studies have shown that ELS can provide rapid relief of symptoms related to esophageal,gastric,small intestinal,colorectal,biliary,and pancreatic neoplastic strictures without compromising cancer patients’overall safety.As a result,in both palliative and neoadjuvant settings,ELS has largely surpassed radiotherapy and surgery as a first-line treatment modality.Following the abovementioned success,the indications for ELS have gradually expanded.To date,ELS is widely used in clinical practice by well-trained endoscopists in managing a wide variety of diseases and complications,such as relieving non-neoplastic obstructions,sealing iatrogenic and non-iatrogenic perforations,closing fistulae and treating post-sphincterotomy bleeding.The abovementioned development would not have been achieved without corresponding advances and innovations in stent technology.However,the technological landscape changes rapidly,making clinicians’adaptation to new technologies a real challenge.In our mini-review article,by systematically reviewing the relevant literature,we discuss current developments in ELS with regard to stent design,accessories,techniques,and applications,expanding the research basis that was set by previous studies and highlighting areas that need to be further investigated. 展开更多
关键词 Endoscopic luminal stenting OBSTRUCTION STRICTURE stentING LEAK Cancer Inflammatory bowel disease Bariatric surgery
下载PDF
Outcomes of colon self-expandable metal stents for malignant vs benign indications at a tertiary care center and review of literature
15
作者 Saqib Walayat Andrew J Johannes +7 位作者 Mark Benson Eric Nelsen Ahmed Akhter Gregory Kennedy Anurag Soni Mark Reichelderfer Patrick Pfau Deepak Gopal 《World Journal of Gastrointestinal Endoscopy》 2023年第4期309-318,共10页
BACKGROUND Endoscopic placement of a self-expandable metal stent(SEMS)is a minimally invasive treatment for use in malignant and benign colonic obstruction.However,their widespread use is still limited with a nationwi... BACKGROUND Endoscopic placement of a self-expandable metal stent(SEMS)is a minimally invasive treatment for use in malignant and benign colonic obstruction.However,their widespread use is still limited with a nationwide analysis showing only 5.4%of patients with colon obstruction undergoing stent placement.This underutilization could be due to perceived increase risk of complications with stent placement.AIM To review long-and short-term clinical success of SEMS use for colonic obstruction at our center.METHODS We retrospectively reviewed all the patients who underwent colonic SEMS placement over aeighteen year period (August 2004 through August 2022) at our academic center. Demographicsincluding age, gender, indication (malignant and benign), technical success, clinical success,complications (perforation, stent migration), mortality, and outcomes were recorded.RESULTSSixty three patients underwent colon SEMS over an 18-year period. Fifty-five cases were formalignant indications, 8 were for benign conditions. The benign strictures included diverticulardisease stricturing (n = 4), fistula closure (n = 2), extrinsic fibroid compression (n = 1), and ischemicstricture (n = 1). Forty-three of the malignant cases were due to intrinsic obstruction from primaryor recurrent colon cancer;12 were from extrinsic compression. Fifty-four strictures occurred on theleft side, 3 occurred on the right and the rest in transverse colon. The total malignant case (n = 55)procedural success rate was 95% vs 100% for benign cases (P = 1.0, NS). Overall complication ratewas significantly higher for benign group: Four complications were observed in the malignantgroup (stent migration, restenosis) vs 2 of 8 (25%) for benign obstruction (1-perforation, 1-stentmigration) (P = 0.02). When stratifying complications of perforation and stent migration there wasno significant difference between the two groups (P = 0.14, NS).CONCLUSIONColon SEMS remains a worthwhile option for colonic obstruction related to malignancy and has ahigh procedural and clinical success rate. Benign indications for SEMS placement appear to havesimilar success to malignant. While there appears to be a higher overall complication rate inbenign cases, our study is limited by sample size. When evaluating for perforation alone theredoes not appear to be any significant difference between the two groups. SEMS placement may bea practical option for indications other that malignant obstruction. Interventional endoscopistsshould be aware and discuss the risk for complications in setting of benign conditions. Indicationsin these cases should be discussed in a multi-disciplinary fashion with colorectal surgery. 展开更多
关键词 Colon cancer OBSTRUCTION MALIGNANCY STRICTURE Self-expandable metal stent stent migration
下载PDF
Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique
16
作者 Qi-Jia Liu Xiao-Feng Cao +3 位作者 Yun Pei Xuan Li Guo-Xiang Dong Chang-Ming Wang 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第10期2133-2141,共9页
BACKGROUND A transjugular intrahepatic portosystemic shunt(TIPS)is widely placed to treat portal hypertension.Because the Viatorr®stent(W.L.Gore and Associates,Flagstaff,AZ,United States)is not available in all h... BACKGROUND A transjugular intrahepatic portosystemic shunt(TIPS)is widely placed to treat portal hypertension.Because the Viatorr®stent(W.L.Gore and Associates,Flagstaff,AZ,United States)is not available in all hospitals in China,the bare metal stent(BMS)/stent-graft combination technique is still popular for TIPS construction.Stent fracture is a complication after TIPS placement using this technique,with limited available literature focusing on it.AIM To assess the incidence of stent fracture after TIPS placement using the BMS/stent-graft combination technique and to identify the risk factors for stent fracture.We proposed technique modifications to improve the clinical results of TIPS placement with the BMS/stent-graft combination technique.METHODS We retrospectively analyzed the computed tomography(CT)data of all patients with portal hypertension who underwent the TIPS procedure between June 2011 and December 2021 in a single center.Patients implanted with the BMS/stent graft and had follow-up imaging data available were included.We identified patients with stent fracture and analyzed their characteristics.Multivariable logistic regression was applied to identify the potential predictors of stent fracture.RESULTS Of the 68 included patients,stent fracture occurred in seven(10.3%)patients.Based on CT images,the stent fractures were categorized into three types.Our study consisted of four(57.1%)type I fractures,one(14.3%)type II fracture,one(14.3%)type IIIa fracture,and one(14.3%)type IIIb fracture.After adjusting for covariates,multivariable logistic regression revealed that the risk factors for stent fracture were the implantation of a greater number of stents[adjusted odds ratio(aOR)=22.2,95%confidence interval(CI):1.2-415.4,P=0.038]and a larger proximal sagittal stent bending angle(aOR=1.1,95%CI:1.0-1.3,P=0.020).CONCLUSION Stent fracture occurred in approximately 10%of patients with portal hypertension who underwent TIPS with the BMS/stent-graft combination technique.The number of implanted stents and stent bending angle at the inferior vena cava end were predictors of stent fracture,which suggests that the incidence of stent fracture could potentially be reduced by procedural modifications. 展开更多
关键词 Portal hypertension Transjugular intrahepatic portosystemic shunt stent fracture Bare metal stent/stent-graft combination Risk factor Fracture types
下载PDF
血管内超声评价StentViz技术在冠状动脉弥漫性长病变中指导支架串联植入的效果 被引量:1
17
作者 陆奕杉 彭龙华 +5 位作者 刘孝钧 徐晤 段洋 冯辉 李志 梁毅 《中国循证心血管医学杂志》 2023年第5期601-604,共4页
目的 通过与冠状动脉造影(CAG)比较,应用血管内超声(IVUS)评价StentViz技术在冠状动脉(冠脉)弥漫性长病变支架植入术中的应用价值。方法 纳入2019年11月1日至2020年12月31日于徐州医科大学附属医院经CAG检查证实冠脉弥漫性长病变患者50... 目的 通过与冠状动脉造影(CAG)比较,应用血管内超声(IVUS)评价StentViz技术在冠状动脉(冠脉)弥漫性长病变支架植入术中的应用价值。方法 纳入2019年11月1日至2020年12月31日于徐州医科大学附属医院经CAG检查证实冠脉弥漫性长病变患者50例为研究对象,随机分为CAG组(n=25)和StentViz组(n=25)。术前使用定量冠脉造影(QCA)对两组CAG相关指标(最小管腔直径、参考血管直径、直径狭窄率)进行测量并比较其差异性;在第1枚支架释放后,CAG组和StentViz组分别在常规CAG和StentViz实时指导下定位串联的支架,由同一位介入医师评估到位满意后,释放支架,选择合适的后扩球囊及压力后扩张支架。术后使用QCA对两组的相关指标(最小支架直径、最大支架直径、平均支架直径)进行测量并比较其差异性;术后两组均行IVUS检查测量串联支架重叠部分的长度、支架的最小、最大直径,比较两组在支架的定位(支架串联重叠部分的长度)及扩张性(支架的扩张指数)的差异性。结果 术前经QCA测量,StentViz组和CAG组在最小管腔直径、参考血管直径、直径狭窄率上均无统计学差异(P>0.05),术后经QCA测量,StentViz组和CAG组在最小支架直径、最大支架直径、平均支架直径上均无统计学差异(P>0.05),术后经IVUS测量,在两组的最小支架直径、最大支架直径和平均直径无统计学差异的前提下(P>0.05),StentViz组的支架偏心指数小于CAG组[(0.16±0.08)vs.(0.22±0.09),P=0.027],StentViz组的支架扩张指数大于CAG组[(0.84±0.08)vs.(0.78±0.09),P=0.027],StentViz组支架扩张优于CAG组。StentViz组串联支架重叠部分长度明显小于CAG组[(1.22±0.32) mm vs.(2.20±0.37) mm,P=0.001]。结论 与常规CAG指导冠脉长病变支架植入相比,StentViz可更加清晰的显示支架影,有效指导支架的定位及扩张。 展开更多
关键词 经皮冠状动脉介入治疗 stentViz 球囊后扩张 冠状动脉造影 支架串联
下载PDF
Recent advances in surface endothelialization of the magnesium alloy stent materials 被引量:1
18
作者 Changjiang Pan Xuhui Liu +7 位作者 Qingxiang Hong Jie Chen Yuxin Cheng Qiuyang Zhang Lingjie Meng Juan Dai Zhongmei Yang Lingren Wang 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2023年第1期48-77,共30页
Magnesium and its alloy have good mechanical properties and biodegradability,and have become the hotspot of the next-generation biodegradable vascular stent materials.However,their rapid degradation in vivo and poor b... Magnesium and its alloy have good mechanical properties and biodegradability,and have become the hotspot of the next-generation biodegradable vascular stent materials.However,their rapid degradation in vivo and poor biocompatibility are still the bottlenecks of clinical applications for the cardiovascular stents.In particular,how to induce the repair and regeneration of the vascular endothelial with normal physiological functions on the surface of the magnesium alloy stent materials represents the key to its clinical application in the field of cardiovascular stents.It has been believed that it is an ideal way to completely solve the postoperative complications through constructing the multifunctional anti-corrosive bioactive coating on the magnesium alloy surface to induce the formation of vascular endothelium with normal physiological functions.However,how to construct a corrosion-resistant multifunctional bioactive coating with the good endothelial regeneration abilities on the magnesium alloy surface still faces a great challenge.This paper mainly focused on highlighting and summarizing the recent advances in the surface endothelialization of the magnesium alloy materials for the vascular stent,including the bio-inert coating,in-situ immobilization of bioactive molecules on the surface,polymer coating loaded with bioactive factors,novel multifunctional polymer coating,bioactive micropatterns,bioactive layer with glycocalyx-like structure,NO-releasing coating and bioactive sol-gel coating.The advantages and disadvantages of these strategies were discussed and analyzed.Finally,in the senses of future development and clinical application,this paper analyzed and summarized the development direction and prospect of surface endothelialization of the magnesium alloy vascular stents.It is anticipated that this review can give the new cues to the surface endothelialization of the cardiovascular magnesium alloy stents and promote future advancements in this field. 展开更多
关键词 Magnesium alloy stent ENDOTHELIALIZATION Surface coating Surface modification
下载PDF
Association of Comorbid Asthma and the Efficacy of Bioabsorbable Steroid-eluting Sinus Stents Implanted After Endoscopic Sinus Surgery in Patients with Chronic Rhinosinusitis with Nasal Polyps 被引量:1
19
作者 Ao HUANG Tao LI +6 位作者 Min-shan LI Zhen-xiao HUANG De-hui WANG Lei CHENG Bing ZHOU Heng WANG Zheng LIU 《Current Medical Science》 SCIE CAS 2023年第5期1005-1012,共8页
Objective To identify factors affecting the efficacy of steroid-eluting sinus stents implanted after endoscopic sinus surgery(ESS)in patients with chronic rhinosinusitis with nasal polyps(CRSwNP).Methods We performed ... Objective To identify factors affecting the efficacy of steroid-eluting sinus stents implanted after endoscopic sinus surgery(ESS)in patients with chronic rhinosinusitis with nasal polyps(CRSwNP).Methods We performed a post-hoc analysis of a randomized self-controlled clinical trial on post-operative implantation of bioabsorbable steroid-eluting stents in patients with CRSwNP.Univariate logistic regression analysis was conducted to identify which of the following factors affect the response to post-operative stent implantation:sex,serum eosinophil levels,history of prior surgery,endoscopic scores,and comorbid conditions(asthma and allergic rhinitis).The primary outcome was the rate of post-operative intervention on day 30,and the secondary outcome was the rate of polypoid tissue formation(grades 2–3)on days 14,30,and 90.Results A total of 151 patients with CRSwNP were included in the post-hoc analysis.Asthma was identified as the only risk factor for a poor response to steroid-eluting sinus stents on post-operative day 30,with an odds ratio of 23.71(95%CI,2.81,200.16;P=0.004)for the need for post-operative intervention and 19(95%CI,2.20,164.16;P=0.003)for moderate-to-severe polypoid tissue formation.In addition,the asthmatic group showed higher rates of post-operative intervention and polypoid tissue formation than the non-asthmatic group on post-operative day 30.Blood eosinophil levels were not identified as a risk factor for poor outcomes after stent implantation.Conclusion Comorbid asthma,but not blood eosinophil level,impairs the efficacy of steroid-eluting sinus stents in the short term after ESS in patients with CRSwNP. 展开更多
关键词 chronic rhinosinusitis ASTHMA nasal polyps outcome steroid-eluting sinus stent
下载PDF
Endoscopic dacryocystorhinostomy with bicanalicular silicone tube intubation for treating chronic dacryocystitis secondary to nasolacrimal duct stent incarceration 被引量:1
20
作者 Shan Lan Jin-Qiang Yu +3 位作者 Feng Ke De-Kun Li Bo Yu Zhen-Kai Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1218-1223,共6页
AIM:To investigate the feasibility of endoscopic dacryocystorhinostomy(En-DCR)with bicanalicular silicone tube intubation for treating chronic dacryocystitis secondary to nasolacrimal duct stent(NDS)incarceration.METH... AIM:To investigate the feasibility of endoscopic dacryocystorhinostomy(En-DCR)with bicanalicular silicone tube intubation for treating chronic dacryocystitis secondary to nasolacrimal duct stent(NDS)incarceration.METHODS:En-DCRs were performed on 44 chronic dacryocystitis patients(46 eyes)secondary to NDS incarceration from April 2016 to October 2022.The granuloma and scar tissues were separated,and the removal of NDS incarceration was achieved during the surgery;the flap of the lacrimal sac was trimmed and anastomosed with nasal mucosal,a bicanalicular silicone tube was implanted,and lacrimal size and condition were assessed.The tube was removed 3mo after surgery.During the final follow-up of 12mo when the surgery was completed,the complications and the rates of surgical success were assessed.RESULTS:This study covered 40 patients(42 eyes).Intraoperatively,it was found that the lacrimal sac became small,and the sac wall had granulation and scar tissue attached to the incarcerated NDS in all eyes.At 12mo after surgery completed,the rates of the functional and anatomical success reached 80.95%(34/42)and 83.33%(35/42),respectively.Under the effect of intranasal ostial closure,seven eyes failed to achieve anatomical success.No serious complications(e.g.,visual impairment,sinusitis,and orbital fat prolapse)was observed.CONCLUSION:With the success rate over 80%and no serious complications,En-DCR with bicanalicular silicone tube implantation is effective in treating chronic dacryocystitis secondary to NDS incarceration. 展开更多
关键词 endoscopic dacryocystorhinostomy bicanalicular silicone tube nasolacrimal duct stent INCARCERATION
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部