In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate ...In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate the time constant of a semiconductor survey meter and confirm the meter’s function. An additional filter was attached to the medical X-ray system to satisfy the standards of N-60 to N-120, more copper plates were added as needed, and the first and second half-value layers were calculated to enable comparisons of the facility’s X-ray system quality with the N-60 to N-120 quality values. Next, we used a medical X-ray system to measure the leakage dose and calculate the time constant of the survey meter. The functionality of the meter was then checked and compared with the energy characteristics of the meter. The experimental results showed that it was possible to use a medical X-ray system to reproduce the N-60 to N-120 radiation quality values and to calculate the time constant from the measured results, assuming actual leakage dosimetry for that radiation quality. We also found that the calibration factor was equivalent to that of the energy characteristics of the survey meter.展开更多
In this paper it has been presented the ELF Survey Meter and its application for investigation of presence of electric and magnetic fields strength in uranium conversion facilities,especially to investigate the effect...In this paper it has been presented the ELF Survey Meter and its application for investigation of presence of electric and magnetic fields strength in uranium conversion facilities,especially to investigate the effect of electric and magnetic sources on the operation of electrical controllers like PLC instruments, electrical drivers and actuators which are sensitive to presence of electrical and magnetic fields and also the effect of high voltage power lines展开更多
In indirect-drive experiment, the blank effect caused by X-rays from Hohlraum will show the dark area in time scale of optical streak camera (OSC). This blank effect, which was a serious problem in indirect-drive shoc...In indirect-drive experiment, the blank effect caused by X-rays from Hohlraum will show the dark area in time scale of optical streak camera (OSC). This blank effect, which was a serious problem in indirect-drive shock wave experiments, has been explained by the semiconductor model. The X-rays cause the band to band transition and the probe laser is absorbed by the intraband transition, which leads to a dark region in time scale of the OSC image. In the experiment, the reflectivity of shock wave front was measured to be about 50% at shock wave velocity 32 km/s and was compared to the theoretical calculations with the Drude free electron model. From the experimental data, it is found that the blank effect can be avoided at radiation temperature of 170 eV if the Al layer is thicker than 60 μm.展开更多
文摘In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate the time constant of a semiconductor survey meter and confirm the meter’s function. An additional filter was attached to the medical X-ray system to satisfy the standards of N-60 to N-120, more copper plates were added as needed, and the first and second half-value layers were calculated to enable comparisons of the facility’s X-ray system quality with the N-60 to N-120 quality values. Next, we used a medical X-ray system to measure the leakage dose and calculate the time constant of the survey meter. The functionality of the meter was then checked and compared with the energy characteristics of the meter. The experimental results showed that it was possible to use a medical X-ray system to reproduce the N-60 to N-120 radiation quality values and to calculate the time constant from the measured results, assuming actual leakage dosimetry for that radiation quality. We also found that the calibration factor was equivalent to that of the energy characteristics of the survey meter.
文摘In this paper it has been presented the ELF Survey Meter and its application for investigation of presence of electric and magnetic fields strength in uranium conversion facilities,especially to investigate the effect of electric and magnetic sources on the operation of electrical controllers like PLC instruments, electrical drivers and actuators which are sensitive to presence of electrical and magnetic fields and also the effect of high voltage power lines
基金Project supported by the National Natural Science Foundation of China (Grant No. 10805041)the Science and Technology Foundation on Plasma Physics Laboratory (Grant No. 9140C6801021001)
文摘In indirect-drive experiment, the blank effect caused by X-rays from Hohlraum will show the dark area in time scale of optical streak camera (OSC). This blank effect, which was a serious problem in indirect-drive shock wave experiments, has been explained by the semiconductor model. The X-rays cause the band to band transition and the probe laser is absorbed by the intraband transition, which leads to a dark region in time scale of the OSC image. In the experiment, the reflectivity of shock wave front was measured to be about 50% at shock wave velocity 32 km/s and was compared to the theoretical calculations with the Drude free electron model. From the experimental data, it is found that the blank effect can be avoided at radiation temperature of 170 eV if the Al layer is thicker than 60 μm.