RESEARCH ON GUARANTEED WATER DEPTH FOR SAFE DRAINING AT ZUYUAN SEWAGE OUTLET
1
作者 Wang Guangping Senior Engineer, Shanghai Investigation and Design Institute, Shanghai 《China Ocean Engineering》 SCIE EI 1990年第2期231-240,共10页
To select the location of sewage outlet in the sewage disposal program of Shanghai is a rather comprehensive problem which covers many fields and has great influences. The sewage outlet at Zuyuan, about 10 km away fro... To select the location of sewage outlet in the sewage disposal program of Shanghai is a rather comprehensive problem which covers many fields and has great influences. The sewage outlet at Zuyuan, about 10 km away from Wusongkou, is situated on the south bank of the South Channel in the Yangtze Estuary. In order to determine the water depth which can guaranteed the safe draining of sewage at the outlet, a statistical method is adopted in this paper for the determination of the guarantee rate of safe draining at Zuyuan sewage outlet by means of the characteristics of fluvial process and previous topographic data, and the guaranteed water depth for safe draining is then determined. 展开更多
关键词 sewage outlet guaranteed DISPOSAL FLUVIAL MUNICIPAL suspended hydraulic YANGTZE affecting
下载PDF
Primary gastroduodenal tuberculosis presenting as gastric outlet obstruction:A case report and review of literature
2
作者 Abdihamid Mohamed Ali Yahye Garad Mohamed +4 位作者 Abdirahman Ahmed Mohamud Abdulkadir Nor Mohamed Mohamed Rage Ahmed Ismail Mohamud Abdullahi Tuba Saydam 《World Journal of Clinical Cases》 SCIE 2024年第8期1536-1543,共8页
BACKGROUND Mycobacterium tuberculosis(TB)is the causative agent of TB,a chronic granulo-matous illness.This disease is prevalent in low-income countries,posing a significant global health challenge.Gastrointestinal TB... BACKGROUND Mycobacterium tuberculosis(TB)is the causative agent of TB,a chronic granulo-matous illness.This disease is prevalent in low-income countries,posing a significant global health challenge.Gastrointestinal TB is one of the three forms.The disease can mimic other intra-abdominal conditions,leading to delayed diagnosis owing to the absence of specific symptoms.While gastric outlet obs-truction(GOO)remains a frequent complication,its incidence has declined with the advent of proton pump inhibitors and Helicobacter pylori eradication therapy.Gastroduodenal TB can cause upper gastrointestinal hemorrhage,obstruction,and malignancy-like tumors.CASE SUMMARY A 23-year-old male presented with recurrent epigastric pain,distension,nausea,vomiting,and weight loss,prompting a referral to a gastroenterologist clinic.Endoscopic examination revealed distorted gastric mucosa and signs of chronic inflammation.However,treatment was interrupted,possibly owing to vomiting or comorbidities such as human immunodeficiency virus infection or diabetes.Subsequent surgical intervention revealed a dilated stomach and diffuse thickening of the duodenal wall.Resection revealed gastric wall effacement with TB.CONCLUSION Primary gastric TB is rare,frequently leading to GOO.Given its rarity,suspicions should be promptly raised when encountering relevant symptoms,often requiring surgical intervention for diagnosis and treatment. 展开更多
关键词 TUBERCULOSIS Gastrointestinal tuberculosis Gastric outlet obstruction Gastroduodenal tuberculosis Case report
下载PDF
Chemical Associations of Heavy Metals in the Sediments near Bailonggang Sewage Discharge Outlet of Shanghai 被引量:1
3
作者 毕春娟 陈振楼 许世远 《Marine Science Bulletin》 CAS 2003年第1期52-58,共7页
The five chemical associations of heavy metals have been extracted continuously using the Tessier extracting method. Results show that Cu, Pb, Fe, Zn and Cr in the sediments are mainly distributed in residual fraction... The five chemical associations of heavy metals have been extracted continuously using the Tessier extracting method. Results show that Cu, Pb, Fe, Zn and Cr in the sediments are mainly distributed in residual fraction, while the major chemical association of Mn is carbonates. Carbonate heavy metals are converted into Fe-Mn oxides in autumn. And in the low tidal flat, after carbonates have changed into ionic heavy metals, some of the elements are transported to the overlying water. Cu, Pb, Fe and Mn have good correlations with each other, and Zn, Cr also show their similarity of chemical behavior in the sediments. 展开更多
关键词 重金属 化学组合 沉积物 上海 下水道出口
下载PDF
Establishing an Assessment Index System for Sewage Treatment Works in China
4
作者 Zuxin Xu Jin Xu 《Engineering》 SCIE EI CAS CSCD 2023年第8期18-22,共5页
1.Introduction The urban sewage treatment system,including sewage pipe networks and sewage treatment plants,is an important infrastructure to ensure urban social and economic operation.In the past few decades,due to t... 1.Introduction The urban sewage treatment system,including sewage pipe networks and sewage treatment plants,is an important infrastructure to ensure urban social and economic operation.In the past few decades,due to the unremitting efforts of the Chinese government,the construction of China’s urban sewage treatment infrastructure has developed rapidly[1]. 展开更多
关键词 TREATMENT sewage sewage
下载PDF
Occurrence and Decay of SARS-CoV-2 in Community Sewage Drainage Systems
5
作者 Qian Dong 蔡俊雄 +8 位作者 刘艳臣 凌海波 Qi Wang Luo-Jing Xiang Shao-Lin Yang Zheng-Sheng Lu Yi Liu Xia Huang 曲久辉 《Engineering》 SCIE EI CAS CSCD 2023年第7期214-219,I0008,I0009,共8页
The rapid spread of the coronavirus disease(COVID-19)pandemic in over 200 countries poses a substantial threat to human health.Severe acute respiratory syndrome coronavirus 2(SARS-CoV-2),which causes COVID-19,can be d... The rapid spread of the coronavirus disease(COVID-19)pandemic in over 200 countries poses a substantial threat to human health.Severe acute respiratory syndrome coronavirus 2(SARS-CoV-2),which causes COVID-19,can be discharged with feces into the drainage system.However,a comprehensive understanding of the occurrence,presence,and potential transmission of SARS-CoV-2 in sewers,especially in community sewers,is still lacking.This study investigated the virus occurrence by viral nucleic acid testing in vent stacks,septic tanks,and the main sewer outlets of community where confirmed patients had lived during the early days of the epidemic in Wuhan,China.The results indicated that the risk of long-term emission of SARS-CoV-2 to the environment via vent stacks of buildings was low after confirmed patients were hospitalized.SARS-CoV-2 were mainly detected in the liquid phase,as opposed to being detected in aerosols,and its RNA in the sewage of septic tanks could be detected for only four days after confirmed patients were hospitalized.The surveillance of SARS-CoV-2 in sewage could be a sensitive indicator for the possible presence of asymptomatic patients in the community,though the viral concentration could be diluted more than ten times,depending on the sampling site,as indicated by the Escherichia coli test.The comprehensive investigation of the community sewage drainage system is helpful to understand the occurrence characteristics of SARS-CoV-2 in sewage after excretion with feces and the feasibility of sewage surveillance for COVID-19 pandemic monitoring. 展开更多
关键词 SARS-CoV-2 Transmission risk Drainage system sewage COMMUNITY
下载PDF
Research Progress Related to Rural Domestic Sewage Treatment
6
作者 Yu Wang Xiujuan Wang 《Agricultural Sciences》 2023年第6期775-784,共10页
Rural domestic sewage treatment is an important part of the rural revitalization strategy and a key action to build a livable, livable and beautiful countryside. This paper composes and summarizes the relevant studies... Rural domestic sewage treatment is an important part of the rural revitalization strategy and a key action to build a livable, livable and beautiful countryside. This paper composes and summarizes the relevant studies on rural domestic sewage treatment from the governance techniques and modes of governance subjects and research perspectives, in order to provide reference for the implementation of rural revitalization strategy and rural domestic sewage treatment research and action implementation. 展开更多
关键词 COUNTRYSIDE Domestic sewage sewage Treatment
下载PDF
Application of Anti-clogging Ecological Soil Sewage Treatment Process in Rural Domestic Sewage Treatment and Prospects
7
作者 Xingyu QI Qiuxia TAN 《Agricultural Biotechnology》 CAS 2023年第3期95-96,共2页
[Objectives] By reasonable water distribution and air supply to soil, soil water permeability is maintained, and the nutrient conditions of degrading bacteria in soil are improved to effectively prevent soil clogging.... [Objectives] By reasonable water distribution and air supply to soil, soil water permeability is maintained, and the nutrient conditions of degrading bacteria in soil are improved to effectively prevent soil clogging. [Methods] Through the innovation and improvement of traditional soil sewage treatment technology, the physical, chemical and biological characteristics of soil for sewage purification are utilized to enhance the pollutant decomposition ability of soil microorganisms and maintain soil water permeability.[Results] It has no secondary pollution, and can effectively remove pollutants such as COD_(Cr), TN, TP, NH_3-N, etc. in sewage. [Conclusions] The operation and maintenance cost is low, and the land can be reused, while water and nutrients can be restored to the land. 展开更多
关键词 Anti-clogging Ecological soil sewage treatment POLLUTANTS
下载PDF
Rural Domestic Sewage Treatment Model: Case Study Based on Dongying Section of the Yellow River Basin
8
作者 Shan Zhang Yu Wang Xiujuan Wang 《Journal of Environmental Protection》 CAS 2023年第3期172-184,共13页
The 20<sup>th</sup> National Congress of the Communist Party of China proposed to promote the improvement of urban and rural living environment and build livable and workable villages and beautiful village... The 20<sup>th</sup> National Congress of the Communist Party of China proposed to promote the improvement of urban and rural living environment and build livable and workable villages and beautiful villages. The development and challenges of rural domestic sewage treatment coexist. Based on the field investigation of 15 administrative villages in 3 districts and counties of Dongying City, there is a big gap between the development status of rural domestic sewage treatment and expectations. Investigate rural domestic sewage treatment cases in-depth, and condense four modes of primitive, developmental, mature and advanced in a variety of different rural domestic sewage treatment models for discussion, among which, the village sewage treatment work under the mature mode has achieved remarkable results, and is at the forefront of the current rural domestic sewage treatment. Through the multi-case analysis method, the practical dilemma of sewage treatment in different models of villages is summarized, and the feasible improvement path is explored, which contributes to the ecological protection and high-quality development of Dongying and the Yellow River Basin. 展开更多
关键词 Rural Domestic sewage Human Settlements Ecological Protection and High-Quality Development of the Yellow River Basin
下载PDF
Outcomes of Transcatheter Closure in Outlet-Type Ventricular Septal Defect after 1 Year
9
作者 Supaporn Roymanee Nantawan Su-angka +4 位作者 Worakan Promphan Kanjarut Wongwaitaweewong Jirayut Jarutach Rujira Buntharikpornpun Pimpak Prachasilchai 《Congenital Heart Disease》 SCIE 2023年第2期169-182,共14页
Background:Ventricular septal defect(VSD)is the most common congenital heart disease.Transcatheter VSD closure is an effective treatment for patients with muscular and perimembranous VSD.However,there is a limit data ... Background:Ventricular septal defect(VSD)is the most common congenital heart disease.Transcatheter VSD closure is an effective treatment for patients with muscular and perimembranous VSD.However,there is a limit data for outlet VSD,especially impact to the aortic valve leaflet after transcatheter closure.This study aims to assess the outcomes of transcatheter closure of the outlet-type ventricular septal defect(OVSD)after 1 postoperative year.Methods:A retrospective study was performed including 50 patients who underwent transcatheter(n=25)and surgical(n=25)OVSD closure during the exact time frame at two medical centres.Results:The median age and body weight of patients in the transcatheter group were significantly higher than those of patients in the surgical group(7.0 vs.2.8 years;27.0 vs.11.4 kg;p<0.01).The defect size in the surgical group was significantly larger than that in the transcatheter group(5.0 vs.3.0 mm;p<0.01).All OVSD patients have successful transcatheter closure(100%)as effective as surgical closure.Less than small residual shunt was present 20%and 8%immediately after the procedure in the transcatheter and surgical groups(p=0.50),which decreased to 12%and 4%at the 1-year follow-up(p=0.61),respectively.No incidence of complete atrioventricular block and other complications was observed in both groups,and no significant differences were noted in the new onset or worsening of the aortic regurgitation in both groups(p=1.0).Conclusions:Transcatheter treatment could be effectively and safely achieved for OVSD closure at 1-year follow-up. 展开更多
关键词 outlet ventricular septal defect aortic valve prolapse aortic regurgitation transcatheter closure OUTCOME INTERVENTION
下载PDF
Modified stomach-partitioning gastrojejunostomy for initially unresectable advanced gastric cancer with outlet obstruction: A case report
10
作者 Xin-Xin Shao Quan Xu +1 位作者 Bing-Zhi Wang Yan-Tao Tian 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第6期1247-1255,共9页
BACKGROUND Chemotherapy followed by gastrojejunostomy remains the main treatment for unresectable gastric cancer(GC)in the middle-or lower-third regions with gastric outlet obstruction(GOO).Radical surgery is performe... BACKGROUND Chemotherapy followed by gastrojejunostomy remains the main treatment for unresectable gastric cancer(GC)in the middle-or lower-third regions with gastric outlet obstruction(GOO).Radical surgery is performed as part of a multimodal treatment strategy for selected patients who respond well to chemotherapy.This study describes a case of successful radical resection with completely laparoscopic subtotal gastrectomy after a modified stomach-partitioning gastrojejunostomy(SPGJ)for obstruction relief,in a patient with GOO.CASE SUMMARY During the initial esophagogastroduodenoscopy,an advanced growth was detected in the lower part of the stomach,which caused an obstruction in the pyloric ring.Following this,a computed tomography(CT)scan revealed the presence of lymph node metastases and tumor invasion in the duodenum,but no evidence of distant metastasis was found.Consequently,we performed a modified SPGJ,a complete laparoscopic SPGJ combined with No.4sb lymph node dissection,for obstruction relief.Seven courses of adjuvant capecitabine plus oxaliplatin combined with Toripalimab(programmed death ligand-1 inhibitor)were administered thereafter.A preoperative CT showed partial response;therefore,completely laparoscopic radical subtotal gastrectomy with D2 lymphadenectomy was performed after conversion therapy,and pathological complete remission was achieved.CONCLUSION Laparoscopic SPGJ combined with No.4sb lymph node dissection was an effective surgical technique for initially unresectable GC with GOO. 展开更多
关键词 GASTROJEJUNOSTOMY Gastric cancer Gastric outlet obstruction Conversion therapy Curative resection Case report
下载PDF
Transoral outlet reduction:Outcomes of endoscopic Roux-en-Y gastric bypass revision in 284 patients at a community practice
11
作者 Daniel B Maselli Vibhu Chittajallu +6 位作者 Chase Wooley Areebah Waseem Daniel Lee Michelle Secic Lauren LDonnangelo Brian Coan Christopher E McGowan 《World Journal of Gastrointestinal Endoscopy》 2023年第10期602-613,共12页
BACKGROUND Transoral outlet reduction(TORe)is a minimally invasive endoscopic revision of Roux-en-Y gastric bypass(RYGB)for weight recurrence;however,little has been published on its clinical implementation in the com... BACKGROUND Transoral outlet reduction(TORe)is a minimally invasive endoscopic revision of Roux-en-Y gastric bypass(RYGB)for weight recurrence;however,little has been published on its clinical implementation in the community setting.AIM To characterize the safety and efficacy of TORe in the community setting for adults with weight recurrence after RYGB.METHODS This is a retrospective cohort study of argon plasma coagulation and purse-string suturing for gastric outlet reduction in consecutive adults with weight recurrence after RYGB at a single community center from September 2020 to September 2022.Patients were provided longitudinal nutritional support via virtual visits.The primary outcome was total body weight loss(TBWL)at twelve months from TORe.Secondary outcomes included TBWL at three months and six months;excess weight loss(EWL)at three,six,and twelve months;twelve-month TBWL by obesity class;predictors of twelve-month TBWL;rates of post-TORe stenosis;and serious adverse events(SAE).Outcomes were reported with descriptive statistics.RESULTS Two hundred eighty-four adults(91.9%female,age 51.3 years,body mass index 39.3 kg/m^(2))underwent TORe an average of 13.3 years after RYGB.Median pre-and post-TORe outlet diameter was 35 mm and 8 mm,respectively.TBWL was 11.7%±4.6%at three months,14.3%±6.3%at six months,and 17.3%±7.9%at twelve months.EWL was 38.4%±28.2%at three months,46.5%±35.4%at six months,and 53.5%±39.2%at twelve months.The number of follow-up visits attended was the strongest predictor of TBWL at twelve months(R^(2)=0.0139,P=0.0005).Outlet stenosis occurred in 11 patients(3.9%)and was successfully managed with endoscopic dilation.There was one instance of post-procedural nausea requiring overnight observation(SAE rate 0.4%).CONCLUSION When performed by an experienced endoscopist and combined with longitudinal nutritional support,purse-string TORe is safe and effective in the community setting for adults with weight recurrence after RYGB. 展开更多
关键词 Transoral outlet reduction Purse-string Roux-en-Y gastric bypass Obesity Endoscopic revision Weight recurrence Gastrojejunal anastomosis
下载PDF
The Hydrodynamic Behaviour of Euboean Gulf Coastal Areas and the Mixing of the Physico-Chemical Characteristics of Urban Sewage Discharged into Them under the Influence of Climate Change
12
作者 Evangelos Tsirogiannis Panagiotis Angelidis 《Computational Water, Energy, and Environmental Engineering》 2023年第4期27-57,共31页
The hydrodynamic circulation within the marine environment is a complex phenomenon, characterized by the interplay of strong tidal forces, atmospheric influences, and bathymetric features. The physical and hydrodynami... The hydrodynamic circulation within the marine environment is a complex phenomenon, characterized by the interplay of strong tidal forces, atmospheric influences, and bathymetric features. The physical and hydrodynamic attributes of this flow play a pivotal role in promoting vertical mixing of seawater masses, thereby facilitating the integration of their physical and chemical parameters, including nutrients and oxygen. Additionally, they are instrumental in governing the dispersion and diffusion of pollutants originating from urban sewage, contributing to the overall water renewal process and environmental quality. This study investigates the potential impact of anticipated increases in average air temperatures on water column stratification in coastal regions susceptible to these dynamic influences. These areas receive treated urban sewage, and the study aims to assess how these temperature changes might influence the dispersion and mixing of pollutant loads present in these coastal waters. 展开更多
关键词 Hydrodynamic Modeling Climate Change Euboean Gulf Greece STRATIFICATION sewage Mixing Water Quality Modeling
下载PDF
Design and Operation of Municipal Rain and Sewage United Pumping Station
13
作者 Ting Ting Liu 《Journal of Architectural Research and Development》 2023年第4期51-56,共6页
In the process of designing a municipal rainwater and sewage pumping station,it is necessary to accurately grasp the design points,reasonably determine the scale of the rainwater and sewage pumping station,scientifica... In the process of designing a municipal rainwater and sewage pumping station,it is necessary to accurately grasp the design points,reasonably determine the scale of the rainwater and sewage pumping station,scientifically select the location and layout,and select materials reasonably.After completing the process design of the municipal rainwater and sewage pumping station and putting it into operation,in order to ensure the normal and stable operation of the pumping station,it is necessary to focus on strengthening the operation and management of diving equipment,cleaning equipment,and electromechanical equipment.The author analyzes the key points and specific design path of the process design of municipal rainwater and sewage pumping stations,and puts forward effective strategies for operation management,hoping to contribute to the scientific design and stable operation of municipal rainwater and sewage pumping stations. 展开更多
关键词 Municipal administration Rainwater and sewage united pumping stations Design path Operation management
下载PDF
热风加热沥青路面冲击射流共轭传热特性
14
作者 徐信芯 刘道成 +3 位作者 郑江溢 蔡万智 顾海荣 张辉 《哈尔滨工业大学学报》 EI CAS CSCD 2024年第4期148-157,共10页
为提高热风加热沥青路面的就地再生加热效果,基于热风冲击射流对流换热和沥青路面内部导热的共轭传热过程,建立了热风加热沥青路面的冲击射流共轭传热理论模型,选取有限容积法得到了共轭传热模型的通用离散方程,采用压力-速度耦合半隐... 为提高热风加热沥青路面的就地再生加热效果,基于热风冲击射流对流换热和沥青路面内部导热的共轭传热过程,建立了热风加热沥青路面的冲击射流共轭传热理论模型,选取有限容积法得到了共轭传热模型的通用离散方程,采用压力-速度耦合半隐式算法(semi-implicit method for pressure linked equations,SIMPLE)获得了整个求解域内温度场分布,选取平均热流密度和平均换热系数反映沥青路面加热效果,通过正交试验研究了热风出口速度和热风出口温度对路面加热效果的影响程度。仿真和试验结果表明:理论计算与实验温度场分布趋势吻合度高,两者平均误差为8.4%;平均热流密度和平均换热系数在加热初期均从最大值急剧下降,而后下降幅度逐渐减小趋于平衡,两者的仿真计算与实验结果趋势相同,平均误差分别为6.4%和7.8%;热风出口速度和热风出口温度对平均热流密度均有显著影响,热风出口速度对平均换热系数有显著影响,热风出口温度对平均换热系数的影响相较于平均热流密度指标表现为不显著。研究结果为后续沥青路面就地热再生热风加热温度控制和加热器设计提供了理论依据。 展开更多
关键词 就地热再生 冲击射流 热风出口速度 热风出口温度 平均热流密度 平均换热系数
下载PDF
添加微藻的水生动植物组合对畜禽养殖场污水净化效应
15
作者 叶美锋 吴晓梅 +1 位作者 吴飞龙 林代炎 《中国沼气》 CAS 2024年第2期73-80,共8页
用正交试验方法研究了添加微藻后的不同水生动植物组合对畜禽养殖场污水的净化效果。结果表明微藻的添加对污水的脱氮除磷效果有促进作用,当小球藻的添加量为1000 mL时,对总氮、硝态氮、总磷的去除效果最好,比未添加小球藻组去除率提高4... 用正交试验方法研究了添加微藻后的不同水生动植物组合对畜禽养殖场污水的净化效果。结果表明微藻的添加对污水的脱氮除磷效果有促进作用,当小球藻的添加量为1000 mL时,对总氮、硝态氮、总磷的去除效果最好,比未添加小球藻组去除率提高4.8%、32.63%、22.18%;当小球藻的添加量为4.4×10^(6)cell·mL^(-1)时,对氨氮、COD的去除效果较好,比未添加小球藻组去除率提高25.77%、13.30%。其中去除水体总氮、硝态氮效果最佳组合为红鲫鱼270 g·m^(-2),小球藻2.2×10^(6)cell·mL^(-1),田螺400 g·m^(-2),黑藻200 g·m^(-2)。去除氨氮最佳组合为红鲫鱼540 g·m^(-2),小球藻4.4×10^(6)cell·mL^(-1),田螺200 g·m^(-2),添加黑藻和苦草(种植比例1∶1,密度200 g·m^(-2))。去除总磷TP最佳组合为红鲫鱼540 g·m^(-2),小球藻2.2×10^(6)cell·mL^(-1),田螺400 g·m^(-2),黑藻(种植密度200 g·m^(-2))。研究表明,应用正交试验可以优化水生植物组合对畜禽污水净化处理工艺,对于不同的目标污染物,具有不同的最优参数组合,综合考虑各因素对各目标污染物的去除效果的影响,可以选择污水净化工艺的最优参数组合,通过回收沼液养殖的微藻用于水生动植物组合进一步净化养殖场污水,实现废弃物资源化循环利用,对于污水深度处理技术具有良好的应用前景。 展开更多
关键词 小球藻 水生植物 养殖场污水 净化
下载PDF
等离子体处理农村污水技术研究现状与趋势 被引量:1
16
作者 王冉冉 张帆 +5 位作者 齐凯 王光荣 张文娟 申小冉 樊梅娜 刘双喜 《智能化农业装备学报(中英文)》 2024年第1期51-57,共7页
近年来,发展中国家农村生活水平的提高和农村工业经济的不断升级,使得农村污水排放也愈加严重。这些来自生产生活污水、农田尾水以及养殖废水的农村污水会严重破坏生态环境,影响居民的幸福指数和经济的发展。本文指出了传统生态法和生... 近年来,发展中国家农村生活水平的提高和农村工业经济的不断升级,使得农村污水排放也愈加严重。这些来自生产生活污水、农田尾水以及养殖废水的农村污水会严重破坏生态环境,影响居民的幸福指数和经济的发展。本文指出了传统生态法和生物处理法存在的处理周期长、受环境影响大、存在二次污染等局限性,进一步探讨了等离子体技术在处理农村污水时应用范围广、处理效率高、无二次污染的优势,填补了等离子体技术在处理农业污水的空白。虽然等离子体的某些反应机理还不明确,对装置要求比较高,这些仍需不断改善,但未来还可以通过与其他技术的结合,进一步提高等离子体技术的效率和适用范围,使其在污水处理领域发挥更大的作用,优化和改进发展中国家农村污水综合处理过程。 展开更多
关键词 等离子体 农村污水 生态法 生物处理法
下载PDF
农村纳污坑塘水体治理技术
17
作者 布凡 高强 《农业工程》 2024年第2期114-118,共5页
研究出一套针对农村纳污坑塘水体治理的相关技术,即预处理+缺氧生化+复合型人工湿地。将纳污坑塘隔离出3个区,农村污水依次经过预处理区、缺氧生化区和水生植物稳定区,通过过滤、混凝、微生物降解、湿地基质吸附和植物吸收等作用,实现... 研究出一套针对农村纳污坑塘水体治理的相关技术,即预处理+缺氧生化+复合型人工湿地。将纳污坑塘隔离出3个区,农村污水依次经过预处理区、缺氧生化区和水生植物稳定区,通过过滤、混凝、微生物降解、湿地基质吸附和植物吸收等作用,实现纳污坑塘水体的高效净化,改善农村的生态环境。 展开更多
关键词 纳污坑塘 治理技术 污水处理 生态环境
下载PDF
多分水口长距离输水工程停泵水锤防护措施
18
作者 杨春霞 李倩 +3 位作者 马经童 郑源 耿魏强 张震 《排灌机械工程学报》 CSCD 2024年第3期250-255,共6页
为了能够有效避免多泵且多分水口输水系统在无防护抽水断电时可能出现较为严重的负水锤带来的危害,建立了全长106.46 km的大型供水工程的数学模型进行系统过渡过程计算,选择空气阀与两阶段液控蝶阀联合防护与单向塔防护2种方案消除其负... 为了能够有效避免多泵且多分水口输水系统在无防护抽水断电时可能出现较为严重的负水锤带来的危害,建立了全长106.46 km的大型供水工程的数学模型进行系统过渡过程计算,选择空气阀与两阶段液控蝶阀联合防护与单向塔防护2种方案消除其负水锤,在前者远不达理想防护效果后针对后者进行优化.结合工程实际在确定了单向塔的数量、位置以及塔高后,对不同位置单向塔的底面积进行多种方案的对比选取,最终选用塔1#的底面积为28.26 m^(2),塔2#的底面积为176.63 m^(2);为了防止单向塔漏空需要分水口以及供水终端调流阀配合关闭,在确保管道最大压力不超出其承压能力的前提下,创新性地对各分水口调流阀与供水终端调流阀的关闭时间规律进行了效果比较,使输水系统能够更加经济安全地稳定运行,为此类长距离多分水口多泵供水工程的水锤防护提供了优化方向. 展开更多
关键词 单向调压塔 多分水口 负水锤 空气阀 关阀规律
下载PDF
进水底物对好氧颗粒污泥特性及微生物群落的影响
19
作者 郝桂珍 赵勇 +3 位作者 陆江锋 王佳伟 李振河 徐利 《水处理技术》 CAS CSCD 2024年第4期91-97,共7页
为了研究进水底物对好氧颗粒污泥(AGS)特性的影响,通过接种絮状污泥于序批式反应器(SBR)中以生活污水和模拟生活污水作为进水底物,对AGS形成过程中的污泥特性和微生物群落展开研究。研究表明:以模拟生活污水为进水底物,发现颗粒污泥内... 为了研究进水底物对好氧颗粒污泥(AGS)特性的影响,通过接种絮状污泥于序批式反应器(SBR)中以生活污水和模拟生活污水作为进水底物,对AGS形成过程中的污泥特性和微生物群落展开研究。研究表明:以模拟生活污水为进水底物,发现颗粒污泥内部以丝状菌为框架,通过对污泥的截留逐渐形成AGS,污泥沉降性能良好。随着AGS的形成胞外聚合物(EPS)组分中蛋白质(PN)含量增加显著,PN/PS由1.77上升至5.80,促进了AGS的形成和稳定性,且EPS含量与Zeta电位、污泥沉降指数呈负相关。连续投加Fe(OH)_(3)胶体抑制了NOB菌的活性,导致生活污水阶段污染物的去除效果较差;AGS形成后污染物的去除效果明显上升,特别是氮、磷污染物。生活污水阶段Candidatus_Microthrix菌属引起了系统内丝状菌膨胀,同时微生物群落丰富度、多样性逐渐降低。模拟生活污水阶段具有疏水性和分泌EPS功能的菌属丰度占比持续上升,例如:unclassified_o__Saccharimonadale(33.%→22.0%)、Zoogloea(3.0%→6.0%)、unclassified_f__Sphingomonadaceae(0.87%→3.1%)菌属等;促进了污泥颗粒化;同时随着污泥颗粒化程度提高,具有反硝化和除磷功能的菌属丰度占比持续上升,保证了AGS系统高效的脱氮除磷性能。 展开更多
关键词 好氧颗粒污泥 生活污水 模拟生活污水 微生物群落
原文传递
生物接触氧化-潜流型人工湿地组合工艺处理农村生活污水的应用案例研究
20
作者 郭伟杰 贡丹丹 +2 位作者 何起利 赵伟华 汤显强 《水处理技术》 CAS CSCD 2024年第3期138-141,147,共5页
以浙江省永康市某农村的生活污水处理及灌溉回用工程为例,对“生物接触氧化-潜流人工湿地”组合工艺处理农村生活污水的设计参数、运行效果和工程效益等进行了分析。该工程设计规模为30 m^(3)/d,研究期间实际处理规模12~20 m^(3)/d,出水... 以浙江省永康市某农村的生活污水处理及灌溉回用工程为例,对“生物接触氧化-潜流人工湿地”组合工艺处理农村生活污水的设计参数、运行效果和工程效益等进行了分析。该工程设计规模为30 m^(3)/d,研究期间实际处理规模12~20 m^(3)/d,出水中TP、NH_(3)-N、COD、BOD5、SS、粪大肠菌群等11项主要指标灌溉期(4月至10月)满足《农田灌溉水质标准》,作为该村苗木基地灌溉用水,非灌溉期(11月至次年3月)出水满足《浙江省农村生活污水处理设施水污染物排放标准》,作为该村荷花种植塘的用水。工程运行期间对TP、NH_(3)-N、COD、BOD_(5)、粪大肠菌群、阴离子表面活性剂、色度、SS和浊度的平均去除率分别为44.3%、65.3%、63.8%、61.7%、76.2%、65.7%、74.2%、54.3%和50.5%。 展开更多
关键词 生物接触氧化 潜流人工湿地 农村生活污水 案例分析
原文传递