期刊文献+
共找到127,385篇文章
< 1 2 250 >
每页显示 20 50 100
Single incision laparoscopic surgery 被引量:2
1
作者 Arun Prasad 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第21期2705-2706,共2页
As a complement to standard laparoscopic surgery and a safe alternative to natural orifice transluminal endoscopic surgery,single incision laparoscopic surgery is gaining popularity.There are expensive ports,disposabl... As a complement to standard laparoscopic surgery and a safe alternative to natural orifice transluminal endoscopic surgery,single incision laparoscopic surgery is gaining popularity.There are expensive ports,disposable hand instruments and flexible endoscopes that have been suggested to do this surgery and would increase the cost of operation.For a simple surgery like laparoscopic cholecystectomy,these extras are not needed and the surgery can be performed using standard ports,instruments and telescopes.Triangular port insertion and use of instruments by the "chop stick method" are recommended to successfully do the procedure as we have done in our so far small series of 40 cases. 展开更多
关键词 single incision laparoscopic surgery CHOLECYSTECTOMY
下载PDF
Therapeutic advances: Single incision laparoscopic hepatopancreatobiliary surgery 被引量:8
2
作者 Stephen Kin Yong Chang Kai Yin Lee 《World Journal of Gastroenterology》 SCIE CAS 2014年第39期14329-14337,共9页
Single-port laparoscopic surgery(SPLS) is proposed to be a step towards minimizing the invasiveness of surgery, and has since gained popularity in several surgical sub-specialties including hepatopancreatobiliary surg... Single-port laparoscopic surgery(SPLS) is proposed to be a step towards minimizing the invasiveness of surgery, and has since gained popularity in several surgical sub-specialties including hepatopancreatobiliary surgery. SPLS has since been applied to cholecystectomy, liver resection as well as pancreatectomy for a multitude of pathologies. Benefits of SPLS over conventional multi-incision laparoscopic surgery include improved cosmesis and potentially post-operative pain at specific time periods and extra-umbilical sites. However, it is also associated with longer operating time, increased rate of complications, and increased rate of port-site hernia. There is no significant difference between length of hospital stay. SPLS has a significant learning curve that affects operating time, rate of conversion and rate of complications. In this article, we review the literature on SPLS in hepatobiliary surgery- cholecystectomy, hepatectomy and pancreatectomy, and offer tips on overcoming potential technical obstacles and minimizing the complications when performing SPLS- surgeon position, position of port and instruments, instrument crossing position, standard hand grip vs reverse hand grip, snooker cue guide position, prevention of incisional hernia. SPLS is a promising direction in laparoscopic surgery, and we recommend step-wise progression of applications of SPLS to various hepatopancreatobiliary surgeries to ensure safe adoption of the surgical technique. 展开更多
关键词 single port LAPAROSCOPIC CHOLECYSTECTOMY Hepatecto
下载PDF
Single incision laparoscopic fundoplication: A systematic review of the literature 被引量:1
3
作者 Konstantinos Perivoliotis Chamaidi Sarakatsianou +1 位作者 Konstantinos Tepetes Ioannis Baloyiannis 《World Journal of Gastrointestinal Surgery》 SCIE CAS 2019年第3期179-190,共12页
BACKGROUND Fundoplication, was first introduced as a surgical treatment method of gastroesophageal reflux disease. Consequently, several modifications of this method have been described, whereas laparoscopic fundoplic... BACKGROUND Fundoplication, was first introduced as a surgical treatment method of gastroesophageal reflux disease. Consequently, several modifications of this method have been described, whereas laparoscopic fundoplication was recently introduced. Although single incision(SI) fundoplication was considered as an alternative to the conventional laparoscopic approach, several studies reported an increased operation duration, and high rates of multiport conversion and incisional hernia.AIM To provide a current overview of the technical variations and the postoperative outcomes of patients submitted to SI fundoplication.METHODS The present systematic review of the literature was designed and conducted on the basis of the PRISMA guidelines. A systematic screening of the electronic scholar databases(Medline, Scopus and Web of Science) was performed.RESULTS Literature search resulted in the identification of 19 studies. Overall, 266, 137 and110 SI Nissen, Dor and Toupet fundoplications were reported, respectively. In the majority of the trials, standard laparoscopic instruments were used. The left liver lobe was displayed through the use of forceps, graspers, retractors, drains or even glue. Both intra-corporeal and extracorporeal suturing was described. Mean operative time was 136.3 min. Overall complication rate was 5.2% and the rate of incisional hernia was 0.9%. No mortality was reported.CONCLUSIONDue to the methodological heterogeneity and the lack of high quality studies comparing multi to single access techniques and the several variations, we conclude that further well designed studies are necessary, in order to evaluate the role of SI fundoplication. 展开更多
关键词 single incision single PORT FUNDOPLICATION NISSEN Dor TOUPET
下载PDF
Long Term Follow up of the Solyx Single Incision Sling in the Treatment of Female Stress Urinary Incontinence (SUI) 被引量:1
4
作者 Scott Serels Michael Douso 《Open Journal of Urology》 2014年第2期13-17,共5页
Objectives: The Solyx System was developed to be easier and safer to use than other slings. It was the objective of this study to retrospectively assess the long-term safety and efficacy of the SolyxTM SIS Sling Syste... Objectives: The Solyx System was developed to be easier and safer to use than other slings. It was the objective of this study to retrospectively assess the long-term safety and efficacy of the SolyxTM SIS Sling System. Methods: After IRB approval and informed consent, chart reviews with follow up phone questionnaires of 69 subjects implanted with the Solyx Sling were collected at 2 sites. All of the patients had SUI and had urethral hypermobility with a q-tip test of >30 degrees. All subjects underwent surgery from 12/2008 to 01/2010 with a mean follow up of 43 months (range 39 -49). Subjects included in this data collection had a mean age of 67 years (range 30 -87). The dominant type of incontinence within the study patients was SUI while 17/69 (25%) of the subjects also had a component of urge incontinence. 38/69 (55%) of study patients had concomitant procedures. Results: Long-term Solyx results showed 64/69 (93%) of patients were subjectively dry by questionnaire and were satisfied with their outcome. 63/69 (91%) would have the procedure again. There were 4 cases of denovo urge incontinence and 2 reports of transient retention. There were no serious adverse events including no bladder, bowel, vessel or nerve perforations and no erosions or extrusions. No pain was reported that was attributed to the implant. Conclusions: Chart review with follow phone questionnaires indicated that the Solyx Sling was a safe, efficacious and less-invasive option for patients requiring SUI surgery and that these results were sustainable for an average of 43 months. 展开更多
关键词 single incision SLING STRESS URINARY INCONTINENCE
下载PDF
Review of 500 single incision laparoscopic colorectalsurgery cases-Lessons learned 被引量:8
5
作者 Deborah S Keller Juan R Flores-Gonzalez +1 位作者 Sergio Ibarra Eric M Haas 《World Journal of Gastroenterology》 SCIE CAS 2016年第2期659-667,共9页
Single incision laparoscopic surgery(SILS) is a minimally invasive platform with specific benefits over traditional multiport laparoscopic surgery. The safety and feasibility of SILS has been proven, and the applicati... Single incision laparoscopic surgery(SILS) is a minimally invasive platform with specific benefits over traditional multiport laparoscopic surgery. The safety and feasibility of SILS has been proven, and the applications continue to grow with experience. After 500 cases at a high-volume, single-institution, we were able to standardize instrumentation and operative steps, as well as develop adaptations in technique to help overcome technical and ergonomic challenges. These technical adaptations have allowed the successful application of SILS to technically difficult patient populations, such as pelvic cases, inflammatory bowel disease cases, and high body mass index patients. This review is a frame of reference for the application and wider integration of the single incision laparoscopic platform in colorectal surgery. 展开更多
关键词 LAPAROSCOPIC COLECTOMY MINIMALLY invasivecolorectal SURGERY single-incision LAPAROSCOPIC SURGERY
下载PDF
Single Incision Laparoscopic Transabdominal Preperitoneal Repair for Strangulated Groin Hernia
6
作者 Po Ching Cathy Ng George Pei Cheung Yang Michael Ka Wah Li 《International Journal of Clinical Medicine》 2013年第6期35-38,共4页
Introduction: Single incision laparoscopic surgery (SILS) has become more popular for various surgical procedures including hernia surgery. Initial results of SILS in elective hernia repair were comparable to those of... Introduction: Single incision laparoscopic surgery (SILS) has become more popular for various surgical procedures including hernia surgery. Initial results of SILS in elective hernia repair were comparable to those of conventional laparoscopic approaches. However the use of SILS in emergency case has not been widely reported. This study aimed to evaluate the feasibility of the use of single incision laparoscopic transabdominal preperitoneal (TAPP) repair for patients presenting with strangulated groin hernia. Method: Emergency single incision laparoscopic TAPP repair were performed in our unit from June 2011 onwards for selected patients. Retrospectively data including the patient demographics, operative time, type of hernia, hospital stay, complications and recurrence rate were collected and analyzed. Result: There were a total of five patients in this series from June 2011 to June 2012. The median age was 62 years old with a male to female ratio of 4:1. Four patients had unilateral hernia (one femoral and three inguinal hernias) and one had bilateral hernia (unilaterally strangulated femoral hernia and bilaterally reducible indirect inguinal hernia). The median operative time was 75 minutes for patients with unilateral repair. None of the patients required bowel resection. The conversion rate to either conventional laparoscopic or open repair was zero. The median hospital stay was 2 days. No major complication or recurrence was detected. Conclusion: This series showed that single port laparoscopic TAPP repair for strangulated groin hernia is a feasible option with no major complication reported. 展开更多
关键词 single incision LAPAROSCOPIC Surgery Transabdominal PREPERITONEAL REPAIR Strangulated HERNIA GROIN HERNIA
下载PDF
Single incision slings: Past, present, and future
7
作者 Scott Serels 《World Journal of Obstetrics and Gynecology》 2015年第3期68-71,共4页
Pubovaginal slings have become the gold standard to treat stress urinary incontinence. Traditionally, the sling referred to a suspensory that was placed under the urethra and brought through the retropubic space and a... Pubovaginal slings have become the gold standard to treat stress urinary incontinence. Traditionally, the sling referred to a suspensory that was placed under the urethra and brought through the retropubic space and anchored on either side of the midline. Since this original concept, there have been many materials used for the sling, and there have been many different anchoring approaches. Most agree that one of the best materials is polypropylene mesh. However, the means of anchoring the device and where best to have this anchorage placed is debatable. The options for anchoring simply include using darts vs not to hold the sling in place. The location of this anchorage, on the other hand, is much more controversial. The main locations are retropubic, transobturator, and via a single incision. The obturator and retropubic slings have become the standard of care over time. The single incision sling, on the other hand, is starting to be more acceptable which has resulted in it being used more frequently. The single incision relies on mainly anchoring the sling through the obturator internus muscle with possible inclusion of the obturator membrane. The purpose of this review article is to present the data that exists for the use of the single incision sling. 展开更多
关键词 阴道 尿失禁 闭孔器 生殖健康
下载PDF
Ten-year observation of corneal densitometry and associated factors following small incision lenticule extraction
8
作者 Xiao-Song Han Fei Xia +4 位作者 Zhuo-Yi Chen Pei-Jun Yao Dong-Mei Yang Jing Zhao Xing-Tao Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期485-490,共6页
●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equival... ●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equivalent of-6.46±1.50 D and mean age 28.23±7.38y were enrolled.Full-scale examinations were conducted on all patients preoperatively and during followup.Visual acuity,manifest refraction,axial length,corneal thickness,corneal higher-order aberrations,and CD were evaluated.●RESULTS:All surgeries were completed successfully without complications or adverse events.Ten-year safety index was 1.17±0.20 and efficacy 1.04±0.28.CD value of 0–6 mm zones in central layer was statistically significantly lower 10y postoperatively,compared with preoperative values(0–2 mmΔ=-1.62,2–6 mmΔ=-1.24,P<0.01).There were no correlations between CD values and factors evaluated.●CONCLUSION:SMILE is a safe and efficient procedure for myopia on a long-term basis.CD values get lower 10y postoperatively,whose mechanism is to be further discussed. 展开更多
关键词 MYOPIA small incision lenticule extraction corneal densitometry
原文传递
Changes in posterior corneal elevation after small incision lenticule extraction for different myopic diopters
9
作者 Xiao-Tong Sun Yang Zhang +5 位作者 Xiao-Kun Mei Nan-Nan Zheng Ling-Zhi Niu Xiao-Li Qu Ai-Ping Song Jian Zhuo 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期491-498,共8页
●AIM:To study the changes and effect factors of posterior corneal surface after small incision lenticule extraction(SMILE)with different myopic diopters.●METHODS:Ninety eyes of 90 patients who underwent SMILE were i... ●AIM:To study the changes and effect factors of posterior corneal surface after small incision lenticule extraction(SMILE)with different myopic diopters.●METHODS:Ninety eyes of 90 patients who underwent SMILE were included in this retrospective study.Patients were allocated into three groups based on the preoperative spherical equivalent(SE):low myopia(SE≥-3.00 D),moderate myopia(-3.00 D>SE>-6.00 D)and high myopia(SE≤-6.00 D).Posterior corneal surfaces were measured by a Scheimpflug camera preoperatively and different postoperative times(1wk,1,3,6mo,and 1y).Posterior mean elevation(PME)at 25 predetermined points of 3 concentric circles(2-,4-,and 6-mm diameter)above the best fit sphere was analyzed.●RESULTS:All surgeries were completed uneventfully and no ectasia was found through the observation.The difference of myopia group was significant at the 2-mm ring at 1 and 3mo postoperatively(1mo:P=0.017;3mo:P=0.018).The effect of time onΔPME was statistically significant(2-mm ring:P=0.001;4-mm ring:P<0.001;6-mm ring:P<0.001).The effect of different corneal locations onΔPME was significant except 1wk postoperatively(1mo:P=0.000;3mo:P=0.000;6mo:P=0.001;1y:P=0.001).Posterior corneal stability was linearly correlated with SE,central corneal thickness,ablation depth,residual bed thickness,percent ablation depth and percent stromal bed thickness.●CONCLUSION:The posterior corneal surface changes dynamically after SMILE.No protrusion is observed on the posterior corneal surface in patients with different degrees of myopia within one year after surgery.SMILE has good stability,accuracy,safety and predictability. 展开更多
关键词 MYOPIA posterior corneal elevation corneal ectasia small incision lenticule extraction
原文传递
Single-atom Pt on carbon nanotubes for selective electrocatalysis
10
作者 Samuel S.Hardisty Xiaoqian Lin +1 位作者 Anthony R.J.Kucernak David Zitoun 《Carbon Energy》 SCIE EI CAS CSCD 2024年第1期63-71,共9页
Utilizing supported single atoms as catalysts presents an opportunity to reduce the usage of critical raw materials such as platinum,which are essential for electrochemical reactions such as hydrogen oxidation reactio... Utilizing supported single atoms as catalysts presents an opportunity to reduce the usage of critical raw materials such as platinum,which are essential for electrochemical reactions such as hydrogen oxidation reaction(HOR).Herein,we describe the synthesis of a Pt single electrocatalyst inside single-walled carbon nanotubes(SWCNTs)via a redox reaction.Characterizations via electron microscopy,X-ray photoelectron microscopy,and X-ray absorption spectroscopy show the single-atom nature of the Pt.The electrochemical behavior of the sample to hydrogen and oxygen was investigated using the advanced floating electrode technique,which minimizes mass transport limitations and gives a thorough insight into the activity of the electrocatalyst.The single-atom samples showed higher HOR activity than state-of-the-art 30%Pt/C while almost no oxygen reduction reaction activity in the proton exchange membrane fuel cell operating range.The selective activity toward HOR arose as the main fingerprint of the catalyst confinement in the SWCNTs. 展开更多
关键词 CONFINEMENT ELECTROCATALYSIS hydrogen PLATINUM single atom catalysts
下载PDF
Metal-organic framework-based single-atom electro-/ photocatalysts: Synthesis, energy applications, and opportunities
11
作者 Munir Ahmad Jiahui Chen +10 位作者 Jianwen Liu Yan Zhang Zhongxin Song Shahzad Afzal Waseem Raza Liaqat Zeb Andleeb Mehmood Arshad Hussain Jiujun Zhang Xian-Zhu Fu Jing-Li Luo 《Carbon Energy》 SCIE EI CAS CSCD 2024年第1期1-43,共43页
Single-atom catalysts(SACs)have gained substantial attention because of their exceptional catalytic properties.However,the high surface energy limits their synthesis,thus creating significant challenges for further de... Single-atom catalysts(SACs)have gained substantial attention because of their exceptional catalytic properties.However,the high surface energy limits their synthesis,thus creating significant challenges for further development.In the last few years,metal–organic frameworks(MOFs)have received significant consideration as ideal candidates for synthesizing SACs due to their tailorable chemistry,tunable morphologies,high porosity,and chemical/thermal stability.From this perspective,this review thoroughly summarizes the previously reported methods and possible future approaches for constructing MOF-based(MOF-derived-supported and MOF-supported)SACs.Then,MOF-based SAC's identification techniques are briefly assessed to understand their coordination environments,local electronic structures,spatial distributions,and catalytic/electrochemical reaction mechanisms.This review systematically highlights several photocatalytic and electrocatalytic applications of MOF-based SACs for energy conversion and storage,including hydrogen evolution reactions,oxygen evolution reactions,O_(2)/CO_(2)/N_(2) reduction reactions,fuel cells,and rechargeable batteries.Some light is also shed on the future development of this highly exciting field by highlighting the advantages and limitations of MOF-based SACs. 展开更多
关键词 carbon energy generation MOF-derived-supported MOF-supported single atoms
下载PDF
Clinical observation of extraction-site incisional hernia after laparoscopic colorectal surgery
12
作者 Bao-Hang Fan Ke-Li Zhong +3 位作者 Li-Jin Zhu Zhao Chen Fang Li Wen-Fei Wu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期710-716,共7页
BACKGROUND Laparoscopic colorectal cancer surgery increases the risk of incisional hernia(IH)at the tumor extraction site.AIM To investigate the incidence of IH at extraction sites following laparoscopic colo-rectal c... BACKGROUND Laparoscopic colorectal cancer surgery increases the risk of incisional hernia(IH)at the tumor extraction site.AIM To investigate the incidence of IH at extraction sites following laparoscopic colo-rectal cancer surgery and identify the risk factors for IH incidence.METHODS This study retrospectively analyzed the data of 1614 patients who underwent la-paroscopic radical colorectal cancer surgery with tumor extraction through the abdominal wall at our center between January 2017 and December 2022.Diffe-rences in the incidence of postoperative IH at different extraction sites and the risk factors for IH incidence were investigated.RESULTS Among the 1614 patients who underwent laparoscopic radical colorectal cancer surgery,303(18.8%),923(57.2%),171(10.6%),and 217(13.4%)tumors were ex-tracted through supraumbilical midline,infraumbilical midline,umbilical,and off-midline incisions.Of these,52 patients developed IH in the abdominal wall,with an incidence of 3.2%.The incidence of postoperative IH was significantly higher in the off-midline incision group(8.8%)than in the middle incision groups[the supraumbilical midline(2.6%),infraumbilical midline(2.2%),and umbilical incision(2.9%)groups](χ^(2)=24.985;P<0.05).Univariate analysis showed that IH occurrence was associated with age,obesity,sex,chronic cough,incision infection,and combined diabetes,anemia,and hypopro-teinemia(P<0.05).Similarly,multivariate analysis showed that off-midline incision,age,sex(female),obesity,incision infection,combined chronic cough,and hypoproteinemia were independent risk factors for IH at the site of laparoscopic colorectal cancer surgery(P<0.05).CONCLUSION The incidence of postoperative IH differs between extraction sites for laparoscopic colorectal cancer surgery.The infraumbilical midline incision is associated with a lower hernia rate and is thus a suitable tumor extraction site. 展开更多
关键词 incisional hernia LAPAROSCOPY Colorectal cancer incision infection
下载PDF
Photostability of colloidal single photon emitter in near-infrared regime at room temperature
13
作者 靳思玥 许兴胜 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期515-520,共6页
The photostability of a colloidal single photon emitter in near-infrared regime at room temperature is investigated.The fluorescence lifetime,blinking phenomenon,and anti-bunching effect of a single CdTeSe/ZnS quantum... The photostability of a colloidal single photon emitter in near-infrared regime at room temperature is investigated.The fluorescence lifetime,blinking phenomenon,and anti-bunching effect of a single CdTeSe/ZnS quantum dot with an emission wavelength of 800 nm at room temperature are studied.The second-order correlation function at zero delay time is much smaller than 0.1,which proves that the emission from single quantum dots at 800 nm is a highly pure single-photon source.The effects of the irradiation duration on the fluorescence from single quantum dots are analyzed.The experimental results can be explained by a recombination model including a multi-nonradiative recombination center model and a multi-charged model. 展开更多
关键词 colloidal quantum dots single photon source BLINKING
原文传递
Purification of copper foils driven by single crystallization
14
作者 寇金宗 赵孟泽 +10 位作者 李兴光 何梦林 杨方友 刘科海 成庆秋 任云龙 刘灿 付莹 吴慕鸿 刘开辉 王恩哥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期506-511,共6页
High-purity copper(Cu) with excellent thermal and electrical conductivity, is crucial in modern technological applications, including heat exchangers, integrated circuits, and superconducting magnets. The current puri... High-purity copper(Cu) with excellent thermal and electrical conductivity, is crucial in modern technological applications, including heat exchangers, integrated circuits, and superconducting magnets. The current purification process is mainly based on the zone/electrolytic refining or anion exchange, however, which excessively relies on specific integrated equipment with ultra-high vacuum or chemical solution environment, and is also bothered by external contaminants and energy consumption. Here we report a simple approach to purify the Cu foils from 99.9%(3N) to 99.99%(4N) by a temperature-gradient thermal annealing technique, accompanied by the kinetic evolution of single crystallization of Cu.The success of purification mainly relies on(i) the segregation of elements with low effective distribution coefficient driven by grain-boundary movements and(ii) the high-temperature evaporation of elements with high saturated vapor pressure.The purified Cu foils display higher flexibility(elongation of 70%) and electrical conductivity(104% IACS) than that of the original commercial rolled Cu foils(elongation of 10%, electrical conductivity of ~ 100% IACS). Our results provide an effective strategy to optimize the as-produced metal medium, and therefore will facilitate the potential applications of Cu foils in precision electronic products and high-frequency printed circuit boards. 展开更多
关键词 PURIFICATION copper foil thermal annealing technique single crystallization
原文传递
Cryptanalysis of efficient semi-quantum secret sharing protocol using single particles
15
作者 高甘 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期254-257,共4页
In paper[Chin.Phys.B 32070308(2023)],Xing et al.proposed a semi-quantum secret sharing protocol by using single particles.We study the security of the proposed protocol and find that it is not secure,that is,the three... In paper[Chin.Phys.B 32070308(2023)],Xing et al.proposed a semi-quantum secret sharing protocol by using single particles.We study the security of the proposed protocol and find that it is not secure,that is,the three dishonest agents,Bob,Charlie and Emily can collude to obtain Alice's secret without the help of David. 展开更多
关键词 security loophole rearranging orders semi-quantum secret sharing single particles
原文传递
Enhancing thermodynamic stability of single-crystal Ni-rich cathode material via a synergistic dual-substitution strategy
16
作者 Jixue Shen Hui Li +6 位作者 Haoyu Qi Zhan Lin Zeheng Li Chuanbo Zheng Weitong Du Hao Chen Shanqing Zhang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第1期428-436,I0010,共10页
Nickel(Ni)-rich cathode materials have become promising candidates for the next-generation electrical vehicles due to their high specific capacity.However,the poor thermodynamic stability(including cyclic performance ... Nickel(Ni)-rich cathode materials have become promising candidates for the next-generation electrical vehicles due to their high specific capacity.However,the poor thermodynamic stability(including cyclic performance and safety performance or thermal stability)will restrain their wide commercial application.Herein,a single-crystal Ni-rich Li Ni_(0.83)Co_(0.12)Mn_(0.05)O_(2) cathode material is synthesized and modified by a dual-substitution strategy in which the high-valence doping element improves the structural stability by forming strong metal–oxygen binding forces,while the low-valence doping element eliminates high Li^(+)/Ni^(2+)mixing.As a result,this synergistic dual substitution can effectively suppress H2-H3 phase transition and generation of microcracks,thereby ultimately improving the thermodynamic stability of Ni-rich cathode material.Notably,the dual-doped Ni-rich cathode delivers an extremely high capacity retention of 81%after 250 cycles(vs.Li/Li+)in coin-type half cells and 87%after 1000 cycles(vs.graphite/Li^(+))in pouch-type full cells at a high temperature of 55℃.More impressively,the dual-doped sample exhibits excellent thermal stability,which demonstrates a higher thermal runaway temperature and a lower calorific value.The synergetic effects of this dual-substitution strategy pave a new pathway for addressing the critical challenges of Ni-rich cathode at high temperatures,which will significantly advance the high-energy-density and high-safety cathodes to the subsequent commercialization. 展开更多
关键词 Ni-rich cathode single crystalline Dual-substitution strategy High-temperature cathode Li-ion batteries
下载PDF
Oxidation behavior of 4774DD1 Ni-based single-crystal superalloy at 980℃ in air
17
作者 Yu Fang Ya-zhou Li +7 位作者 Qiang Yang Qun-gong He Xiu-fang Gong Qian Duan Hai-yang Song Fu Wang Qiong-yuan Zhang Hong Zeng 《China Foundry》 SCIE EI CAS CSCD 2024年第2期116-124,共9页
The oxidation behavior of a novel Ni-based single-crystal 4774DD1 superalloy for industrial gas turbine applications was investigated by the isothermal oxidation at 980℃ and discontinuous oxidation weight gain method... The oxidation behavior of a novel Ni-based single-crystal 4774DD1 superalloy for industrial gas turbine applications was investigated by the isothermal oxidation at 980℃ and discontinuous oxidation weight gain methods.The phase constitution and morphology of surface oxides and the characteristics of the crosssection oxide film were analyzed by XRD,SEM and EDS.Results show that the oxidation kinetics of the 4774DD1 superalloy follows the cubic law,indicating its weak oxidation resistance at this temperature.As the oxidation time increases,the composition of the oxide film evolves as following:One layer consisting of a bottom Al_(2)O_(3)sublayer and an upper(Al_(2)O_(3)+NiO)mixture sublayer after oxidized for 25 h.Then,two layers composed of an outermost small NiO discontinuous grain layer and an internal layer for 75 h.This internal layer is consisted of the bottom Al_(2)O_(3)sublayer,an intermediate narrow CrTaO_(4)sublayer,and an upper(Al_(2)O_(3)+NiO)mixture sublayer.Also two layers comprising an outermost relative continuous NiO layer with large grain size and an internal layer as the oxidation time increases to 125 h.This internal layer is composed of the upper(Al_(2)O_(3)+NiO)mixture sublayer,an intermediate continuous(CrTaO_(4)+NiWO_(4))mixture sublayer,and a bottom Al_(2)O_(3)sublayer.Finally,three layers consisting of an outermost(NiAl2O_(4)+NiCr2O_(4))mixture layer,an intermediate(CrTaO_(4)+NiWO_(4))mixture layer,and a bottom Al_(2)O_(3)layer for 200 h. 展开更多
关键词 nickel-base single crystal superalloy oxidation kinetics oxide film MICROSTRUCTURE mechanism
下载PDF
Comprehensive integration of single-cell transcriptomic data illuminates the regulatory network architecture of plant cell fate specification
18
作者 Shanni Cao Xue Zhao +6 位作者 Zhuojin Li Ranran Yu Yuqi Li Xinkai Zhou Wenhao Yan Dijun Chen Chao He 《Plant Diversity》 SCIE CAS CSCD 2024年第3期372-385,共14页
Plant morphogenesis relies on precise gene expression programs at the proper time and position which is orchestrated by transcription factors(TFs)in intricate regulatory networks in a cell-type specific manner.Here we... Plant morphogenesis relies on precise gene expression programs at the proper time and position which is orchestrated by transcription factors(TFs)in intricate regulatory networks in a cell-type specific manner.Here we introduced a comprehensive single-cell transcriptomic atlas of Arabidopsis seedlings.This atlas is the result of meticulous integration of 63 previously published scRNA-seq datasets,addressing batch effects and conserving biological variance.This integration spans a broad spectrum of tissues,including both below-and above-ground parts.Utilizing a rigorous approach for cell type annotation,we identified 47 distinct cell types or states,largely expanding our current view of plant cell compositions.We systematically constructed cell-type specific gene regulatory networks and uncovered key regulators that act in a coordinated manner to control cell-type specific gene expression.Taken together,our study not only offers extensive plant cell atlas exploration that serves as a valuable resource,but also provides molecular insights into gene-regulatory programs that varies from different cell types. 展开更多
关键词 ARABIDOPSIS single cell transcriptome Gene regulatory network Data integration Plant cell atlas
下载PDF
Micro-power negative pressure wound technique reduces risk of incision infection following loop ileostomy closure
19
作者 Deng-Yong Xu Bing-Jun Bai +4 位作者 Lina Shan Hui-Yan Wei Deng-Feng Lin Ya Wang Da Wang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期186-195,共10页
BACKGROUND Prophylactic loop ileostomy is an effective way to reduce the clinical severity of anastomotic leakage following radical resection of rectal cancer.Incisional surgical site infection(SSI)is a common complic... BACKGROUND Prophylactic loop ileostomy is an effective way to reduce the clinical severity of anastomotic leakage following radical resection of rectal cancer.Incisional surgical site infection(SSI)is a common complication after ileostomy closure.AIM To evaluate the efficacy and safety of the micro-power negative pressure wound technique(MPNPWT)in preventing incisional SSI.METHODS This was a prospective,randomized controlled clinical trial conducted at a single center.A total of 101 consecutive patients who underwent ileostomy closure after rectal cancer surgery with a prophylactic ileostomy were enrolled from January 2019 to December 2021.Patients were randomly allocated into an MPNPWT group and a control group.The MPNPWT group underwent intermittent suturing of the surgical incision with 2-0 Prolene and was covered with a micro-power negative pressure dressing.The surgical outcomes were compared between the MPNPWT(n=50)and control(n=51)groups.Risk factors for incisional SSI were identified using logistic regression.RESULTS There were no differences in baseline characteristics between the MPNPWT(n=50)and control groups(n=51).The incisional SSI rate was significantly higher in the control group than in the MPNPWT group(15.7%vs 2.0%,P=0.031).However,MPNPWT did not affect other surgical outcomes,including intra-abdominal complications,operative time,and blood loss.Postoperative hospital stay length and hospitalization costs did not differ significantly between the two groups(P=0.069 and 0.843,respectively).None of the patients experienced adverse effects of MPNPWT,including skin allergy,dermatitis,and pain.MPNPWT also helped heal the infected incision.Our study indicated that MPNPWT was an independent protective factor[odds ratio(OR)=0.005,P=0.025)]and diabetes was a risk factor(OR=26.575,P=0.029)for incisional SSI.CONCLUSION MPNPWT is an effective and safe way to prevent incisional SSI after loop ileostomy closure. 展开更多
关键词 Micro-power negative pressure technique Ileostomy closure incisional surgical site infection Infection prevention Postoperative incision
下载PDF
Localization effect in single crystal of RuAs_(2)
20
作者 易哲铠 刘琪 +12 位作者 光双魁 徐升 岳小宇 梁慧 李娜 周颖 吴丹丹 孙燕 李秋菊 程鹏 夏天龙 孙学峰 王义炎 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期195-200,共6页
We report the magnetotransport and thermal properties of RuAs_(2) single crystal.RuAs_(2) exhibits semiconductor behavior and localization effect.The crossover from normal state to diffusive transport in the weak loca... We report the magnetotransport and thermal properties of RuAs_(2) single crystal.RuAs_(2) exhibits semiconductor behavior and localization effect.The crossover from normal state to diffusive transport in the weak localization(WL)state and then to variable range hopping(VRH)transport in the strong localization state has been observed.The transitions can be reflected in the measurement of resistivity and Seebeck coefficient.Negative magnetoresistance(NMR)emerges with the appearance of localization effect and is gradually suppressed in high magnetic field.The temperature dependent phase coherence length extracted from the fittings of NMR also indicates the transition from WL to VRH.The measurement of Hall effect reveals an anomaly of temperature dependent carrier concentration caused by localization effect.Our findings show that RuAs_(2) is a suitable platform to study the localized state. 展开更多
关键词 weak localization variable range hopping RuAs_(2)single crystal
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部