期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Three-dimensional Finite Element Analysis of a Newly Designed Onplant Miniplate Anchorage System
1
作者 刘琳 屈银英 +2 位作者 蒋立君 周倩 唐天琪 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2016年第3期422-427,共6页
The purpose of this research was to evaluate the structural stress and deformation of a newly designed onplant miniplate anchorage system compared to a standard anchorage system. A bone block integrated with a novel m... The purpose of this research was to evaluate the structural stress and deformation of a newly designed onplant miniplate anchorage system compared to a standard anchorage system. A bone block integrated with a novel miniplate and fixation screw system was simulated in a three-dimensional model and subjected to force at different directions. The stress distribution and deformation of the miniplate system and cortical bone were evaluated using the three-dimensional finite element method. The results showed that the stress on the plate system and bone was linearly proportional to the force magnitude and was higher when the force was in a vertical direction(Y-axis). Stress and deformation values of the two screws(screw 1 and 2) were asymmetric when the force was added along Y-axis and was greater in screw 1. The highest deformation value of the screws was 7.5148 μm, much smaller than the limit value. The load was decreased for each single miniscrew, and the ability of the new anchorage system to bear the load was also enhanced to some degree. It was suggested that the newly designed onplant miniplate anchorage system is effective, easily implanted and minimally invasive. 展开更多
关键词 onplant miniplate anchorage system temporary skeletal anchorage devices finite element analysis skeletal anchorage system
下载PDF
Systematic review of mini-implant displacement under orthodontic loading 被引量:2
2
作者 Manuel Nienkemper Jrg Handschel Dieter Drescher 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第1期1-6,共6页
A growing number of studies have reported that mini-implants do not remain in exactly the same position during treatment, although they remain stable. The aim of this review was to collect data regarding primary displ... A growing number of studies have reported that mini-implants do not remain in exactly the same position during treatment, although they remain stable. The aim of this review was to collect data regarding primary displacement immediately straight after loading and secondary displacement over time. A systematic review was performed to investigate primary and secondary displacement. The amount and type of displacement were recorded. A total of 27 studies were included. Sixteen in vitro studies or studies using finite element analysis addressed primary displacement, and nine clinical studies and two animal studies addressed secondary displacement. Significant primary displacement was detected (6.4-24.4 μm) for relevant orthodontic forces (0.5-2.5 N). The mean secondary displacement ranged from 0 to 2.7 mm for entire mini-implants, The maximum values for each clinical study ranged from 1.0 to 4.1 mm for the head, 1.0 to 1.5 for the body and 1,0 to 1.92 mm for the tail part. The most frequent type of movement was controlled tipping or bodily movement. Primary displacement did not reach a clinically significant level. However, clinicians can expect relevant secondary displacement in the direction of force. Consequently, decentralized insertion within the inter-radicular space, away from force direction, might be favourable. More evidence is needed to provide quantitative recommendations. 展开更多
关键词 DISPLACEMENT MIGRATION MINI-IMPLANT MINISCREW ORTHODONTICS skeletal anchorage
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部