期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Seismic Behaviour of Beam-Column Joints of Precast and Partial Steel Reinforced Concrete 被引量:1
1
作者 Wanpeng Cheng Licheng Wang +1 位作者 Yupu Song Jun Wang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2015年第2期108-117,共10页
A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is locate... A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is located in the core joint region and the connections between concrete members. This paper presents an experimental study of a series of PPSRC specimens. These specimens are tested under low cyclic loading.Experimental results demonstrate that the bearing capacity of the PPSRC specimens is 3 times that of the ordinary reinforced concrete( RC) beam-column joints. The strength and stiffness degradation rates are slower compared with that of the RC beam-column joints. In addition,the strength of the core joint region and the connections is higher than other parts of the PPSRC specimens. Beam failure occurs firstly for the PPSRC specimens,followed by column failure and connections failure. The failure of the core joint region occurs finally.Test results show that the seismic performance of the PPSRC is better than that of the ordinary RC beam-column joints. 展开更多
关键词 precast and partial steel reinforced concrete(PPSRC) beam-column joints low cyclic test hysteretic curve degradations of strength and stiffness DUCTILITY
下载PDF
Mesoscopic Modeling Approach and Application for Steel Fiber Reinforced Concrete under Dynamic Loading:A Review 被引量:2
2
作者 Jinhua Zhang Zhangyu Wu +2 位作者 Hongfa Yu Haiyan Ma Bo Da 《Engineering》 SCIE EI CAS 2022年第9期220-238,共19页
Steel fiber reinforced concrete(SFRC)has drawn extensive attention in recent years for its superior mechanical response to dynamic and impact loadings.Based on the existing test results,the highstrength steel fibers e... Steel fiber reinforced concrete(SFRC)has drawn extensive attention in recent years for its superior mechanical response to dynamic and impact loadings.Based on the existing test results,the highstrength steel fibers embedded in a concrete matrix usually play a strong bridging effect to enhance the bonding force between fiber and the matrix,and directly contribute to the improvement of the post-cracking behavior and residual strength of SFRC.To gain a better understanding of the action behavior of steel fibers in matrix and further capture the failure mechanism of SFRC under dynamic loads,the mesoscopic modeling approach that assumes SFRC to be composed of different mesoscale phases(i.e.,steel fibers,coarse aggregates,mortar matrix,and interfacial transition zone(ITZ))has been widely employed to simulate the dynamic responses of SFRC material and structural members.This paper presents a comprehensive review of the state-of-the-art mesoscopic models and simulations for SFRC under dynamic loading.Generation approaches for the SFRC mesoscale model in the simulation works,including steel fiber,coarse aggregate,and the ITZ between them,are reviewed and compared systematically.The material models for different phases and the interaction relationship between fiber and concrete matrix are summarized comprehensively.Additionally,some example applications for SFRC under dynamic loads(i.e.,compression,tension,and contact blast)simulated using the general mesoscale models are given.Finally,some critical analysis on the current shortcomings of the mesoscale modeling of SFRC is highlighted,which is of great significance for the future investigation and development of SFRC. 展开更多
关键词 steel fiber reinforced concrete Mesoscale modeling Dynamic loading Materials model Interfacial characteristic
下载PDF
Effect of Steel Fiber on Concrete’s Compressive Strength
3
作者 Mohammed Saed Yusuf Abdirisak Bashir Isak +4 位作者 Guled Ali Mohamud Abdullahi Hashi Warsame Yahye Ibrahim Osman Abdullahi Husein Ibrahim Liban Abdi Aziz Elmi 《Open Journal of Civil Engineering》 CAS 2023年第1期192-197,共6页
The general goal of this research is to investigate whether steel fiber has a significant “positive” or “negative” influence on concrete compressive strength, as well as the optimal steel fiber ratio that delivers... The general goal of this research is to investigate whether steel fiber has a significant “positive” or “negative” influence on concrete compressive strength, as well as the optimal steel fiber ratio that delivers best result. Manually, cement, fine aggregates, coarse aggregates, steel fibers, and water were mixed together properly. A slump test was carried on the mixed concrete. After determining the workability, the mixed concrete was poured into cubes dimension 150 mm × 150 mm × 150 mm and left for 24 hours. After 24 hours, the samples were removed from the mold and placed in a water tank to cure for 7 to 28 days. The cube was tested for compressive and flexural strength in a universal testing machine after the samples had cured for the required 7 - 28 days. This study focuses on how to obtain high strength concrete using with steel fiber in the Conventional mix ratio to enhance concrete strength. Concrete reinforcement using steel fibers alters the characteristics of the concrete, allowing it to withstand fracture and hence improve its mechanical qualities. This study reports on an experimental study that reveals the effect of steel fiber on concrete compressive strength and the optimal steel fiber ratio that produces the best results. Steel fiber reinforcing improved the compressive strength of concrete. The average compressive strength of normal M25 concrete with 0% steel fibers and curing ages of 7 and 28 days was determined to be 22.97 N/mm<sup>2</sup> and 25.78 N/mm<sup>2</sup>, respectively. The steel fibers are then added in various concentrations, such as 1%, 2%, and 3%, with aspect ratios of 70. The compressive strength of concrete with 1%, 2%, and 3% steel fiber with an aspect ratio of 70 was examined at 7 days and found to be 23.96, 24.80, and 26.14 N/mm<sup>2</sup> correspondingly. 展开更多
关键词 steel Fiber reinforced concrete Fiber Reinforcement Compression Strength of concrete Improvement Compression Strength
下载PDF
Toughness of Polymer Modified Steel Fiber Reinforced Concrete
4
作者 U. B. Kalwane Y. M. Ghugal A. G. Dahake 《Open Journal of Civil Engineering》 2016年第1期8-18,共11页
An experimental investigation is carried out to study the toughness of polymer modified steel fiber reinforced concrete. Volume fraction of steel fibers is varied from 0% to 7% at the interval of 1% by weight of cemen... An experimental investigation is carried out to study the toughness of polymer modified steel fiber reinforced concrete. Volume fraction of steel fibers is varied from 0% to 7% at the interval of 1% by weight of cement. 15% SBR latex polymer was used by weight of cement. Cubes of size 150 × 150 × 150 mm for compressive strength, prism specimens of size 150 mm × 150 mm × 700 mm for flexure strength and, specimen of size 150 × 150 × 150 mm with 16 mm diameter tor steel bar of length 650 mm embedded in concrete cube at the center for bond test were prepared. Various specimens were tested after 28 days of curing. Area under curve (toughness) is measured and mentioned in this work. 展开更多
关键词 TOUGHNESS steel Fiber reinforced concrete Polymer Modified steel Fiber reinforced concrete
下载PDF
A State-of-the-Art Review of Electrochemical Chloride Extraction for Concrete Structures
5
作者 Thamara Tofeti Lima 《Open Journal of Civil Engineering》 CAS 2023年第1期1-24,共24页
Electrochemical chloride extraction is a promising technique for the rehabilitation of concrete structures under chloride induced corrosion. This study consists of an extensive literature review of this treatment incl... Electrochemical chloride extraction is a promising technique for the rehabilitation of concrete structures under chloride induced corrosion. This study consists of an extensive literature review of this treatment including application cases. It is found that the rate of chlorides removed is affected by the total charge passed, whereas increasing charge in a range between 1500 to 2000 Ah/m<sup>2</sup> increases the amount of chlorides removed and this can be more effective by increasing current density instead of duration of treatment. Bound chlorides are extracted during treatment and, water works better than Ca(OH)<sub>2</sub> as an electrolyte, possibly due to modifications on the concrete pore structure. Moreover, ECE is not efficient in repassivate structures but is efficient in its purpose of removing chlorides if treatment setup is well planned, which justifies the need for better international standards on the topic. 展开更多
关键词 Chloride Induced Corrosion Corrosion Rehabilitation Electrochemical Chloride Extraction Electrochemical Rehabilitation Methods steel reinforced concrete
下载PDF
Improvement of Concrete Properties and Reinforcing Steel Inhibition Using a Natural Product Admixture
6
作者 S.H. Tantawi (Building Research Institute, Dokki, Cairo, Egypt)I.Z.Selim (Physical Chemistry Dept., National Research Center, Dokki, Cairo, Egypt (To whom correspondence should be addressed) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1996年第2期95-99,共5页
The use of a natural white juice, taken from magrabe banana stem, as concrete admixture to improve mechanical and physicrvchemical properties of concrete has been studied. The compressive strength, bulk density the fr... The use of a natural white juice, taken from magrabe banana stem, as concrete admixture to improve mechanical and physicrvchemical properties of concrete has been studied. The compressive strength, bulk density the free lime liberated during hydration and the combined water content were determined. The results indicate that the admixture acts as a retarder in most cases and as accelerator in some ones. Also, the admixture effect on the corrosion resistance of the reinforcing steel against surrounding aggressive media has been investigated using galvanostatic polarization technique. The addition of 0.2% admixture leads to the more inhibition of the 展开更多
关键词 pH FIGURE Improvement of concrete Properties and Reinforcing steel Inhibition Using a Natural Product Admixture OH
下载PDF
Corrosion Behaviour and Chloride Attack of Reinforcing Steel in Presence of Concrete Admixtures
7
作者 I.Z.Selim (Physical Chemistry Dept., National Research Center, Dokki, Cairo, Egypt 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1998年第4期339-343,共5页
Corrosion and electrochemical behaviour of reinforcing steel embedded in cement pastes with and without concrete admixtures used in Egypt to modify concrete properties have been studied. The influence of the admixture... Corrosion and electrochemical behaviour of reinforcing steel embedded in cement pastes with and without concrete admixtures used in Egypt to modify concrete properties have been studied. The influence of the admixtures on the corrosion resistance of the steel against chloride attack has been studied using impressed current and impressed voltage techniques. The results indicate that the type and concentration of the admixture used have an important effed on the extent of chloride induced corrosion of the steel. The mechanism of corrosion of steel due to chloride attack is discussed. 展开更多
关键词 SCE Corrosion Behaviour and Chloride Attack of Reinforcing steel in Presence of concrete Admixtures RES
全文增补中
Acoustic emissions evaluation of the dynamic splitting tensile properties of steel fiber reinforced concrete under freeze-thaw cycling
8
作者 Hua ZHANG Xinyue LIU +3 位作者 Lingyu BAI Shanshan JI Luoyu PAN Xuechen LI 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2023年第9期1341-1356,共16页
This study empirically investigated the influence of freeze-thaw cycling on the dynamic splitting tensile properties of steel fiber reinforced concrete(SFRC).Brazilian disc splitting tests were conducted using four lo... This study empirically investigated the influence of freeze-thaw cycling on the dynamic splitting tensile properties of steel fiber reinforced concrete(SFRC).Brazilian disc splitting tests were conducted using four loading rates(0.002,0.02,0.2,and 2 mm/s)on specimens with four steel fiber contents(0%,0.6%,1.2%,and 1.8%)subjected to 0 and 50 freeze-thaw cycles.The dynamic splitting tensile damage characteristics were evaluated using acoustic emission(AE)parameter analysis and Fourier transform spectral analysis.The results quantified using the freeze-thaw damage factor defined in this paper indicate that the degree of damage to SFRC caused by freeze-thaw cycling was aggravated with increasing loading rate but mitigated by increasing fiber content.The percentage of low-frequency AE signals produced by the SFRC specimens during loading decreased with increasing loading rate,whereas that of high-frequency AE signals increased.Freeze-thaw action had little effect on the crack types observed during the early and middle stages of the loading process;however,the primary crack type observed during the later stage of loading changed from shear to tensile after the SFRC specimens were subjected to freeze-thaw cycling.Notably,the results of this study indicate that the freeze-thaw damage to SFRC reduces AE signal activity at low frequencies. 展开更多
关键词 steel fiber reinforced concrete freeze-thaw cycling Brazilian disc splitting test acoustic emission technique dynamic splitting tensile acoustic emission properties
原文传递
Effect of organic silicon quaternary ammonium salts on mitigating corrosion of reinforced steel induced by SRB in mild alkaline simulated concrete pore solution 被引量:4
9
作者 Ini-Ibehe Nabuk Etim Junhua Dong +6 位作者 Jie Wei Chen Nan Durga Bhakt Pokharel Aniefiok Joseph Umoh Dake Xu Mingzhong Su Wei Ke 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2021年第5期126-140,共15页
The corrosion damage of 20 SiMn steel by sulphate-reducing bacteria(SRB)and the mitigation effect of organic silicon quaternary ammonium salt(OSA)were studied in sterilized mild alkaline simulated concrete pore soluti... The corrosion damage of 20 SiMn steel by sulphate-reducing bacteria(SRB)and the mitigation effect of organic silicon quaternary ammonium salt(OSA)were studied in sterilized mild alkaline simulated concrete pore solution(STR)with different additions of SRB and OSA at pH 9.35 for 28 days.Uniform corrosion occurs in STR medium while slight localized corrosion is observed in STR+OSA medium,and localized pitting corrosion occurs in STR+SRB and STR+SRB+OSA media.The largest pit depth reduces from 36.70μm in STR+SRB medium to 3.31μm in STR+SRB+OSA medium due to the mitigation effect of OSA.The corrosion rate reflected by weight loss and electrochemical impedance spectroscopy(EIS)results presents the order of STR<STR+OSA<STR+SRB+OSA<STR+SRB,which also proves that the presence of SRB can accelerate corrosion in a carbonated medium.However,OSA as an efficient bacteriostatic agent can reduce the excessive growth of SRB and thus reduce corrosion. 展开更多
关键词 steel reinforced concrete Microbial corrosion BIOCIDE EIS
原文传递
Axial compression tests and numerical simulation of steel reinforced recycled concrete short columns confined by carbon fiber reinforced plastics strips 被引量:1
10
作者 Hui MA Fangda LIU +2 位作者 Yanan WU Xin A Yanli ZHAO 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2022年第7期817-842,共26页
To research the axial compression behavior of steel reinforced recycled concrete(SRRC)short columns confined by carbon fiber reinforced plastics(CFRP)strips,nine scaled specimens of SRRC short columns were fabricated ... To research the axial compression behavior of steel reinforced recycled concrete(SRRC)short columns confined by carbon fiber reinforced plastics(CFRP)strips,nine scaled specimens of SRRC short columns were fabricated and tested under axial compression loading.Subsequently,the failure process and failure modes were observed,and load-displacement curves as well as the strain of various materials were analyzed.The effects on the substitution percentage of recycled coarse aggregate(RCA),width of CFRP strips,spacing of CFRP strips and strength of recycled aggregate concrete(RAC)on the axial compression properties of columns were also analyzed in the experimental investigation.Furthermore,the finite element model of columns which can consider the adverse influence of RCA and the constraint effect of CFRP strips was founded by ABAQUS software and the nonlinear parameter analysis of columns was also implemented in this study.The results show that the first to reach the yield state was the profile steel in the columns,then the longitudinal rebars and stirrups yielded successively,and finally RAC was crushed as well as the CFRP strips was also broken.The replacement rate of RCA has little effect on the columns,and with the substitution rate of RCA from 0 to 100%,the bearing capacity of columns decreased by only 4.8%.Increasing the CFRP strips width or decreasing the CFRP strips spacing could enhance the axial bearing capacity of columns,the maximum increase was 10.5%or 11.4%,and the ductility of columns was significantly enhanced.Obviously,CFRP strips are conducive to enhance the axial bearing capacity and deformation capacity of columns.On this basis,considering the restraint effect of CFRP strips and the adverse effects of RCA,the revised formulas for calculating the axial bearing capacity of SRRC short columns confined by CFRP strips were proposed. 展开更多
关键词 steel reinforced recycled concrete CFRP strips short columns axial compression behavior recycled aggregate concrete
原文传递
Compressive and cyclic flexural response of double-hooked-end steel fiber reinforced concrete
11
作者 Demewoz W.MENNA Aikaterini S.GENIKOMSOU Mark F.GREEN 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2022年第9期1104-1126,共23页
Recent developments on high-performance double-hooked-end steel fibers have enhanced the wide applications of steel fiber reinforced concrete(SFRC).This study presents the compressive properties and the cyclic flexura... Recent developments on high-performance double-hooked-end steel fibers have enhanced the wide applications of steel fiber reinforced concrete(SFRC).This study presents the compressive properties and the cyclic flexural performance of the SFRC that were experimentally examined.Three different double-hooked-end steel fibers at 0.25%,0.5%,0.75%,and 1%volume fractions were considered.All fiber types had similar length to diameter ratios,while the first two fiber types had similar anchorage mechanisms(4D)and tensile strength and the third type had different anchorage mechanism(5D)and a higher tensile strength.The increased volumetric ratio of the fibers increased the post-peak compressive strain(ductility),the tensile strength,and the cyclic flexural strength and cumulative energy dissipation characteristics of the SFRC.Among the 4D fibers,the mixtures with the larger steel fibers showed higher flexural strength and more energy dissipation compared to the SFRCs with smaller size fibers.For 1%steel fiber dosage,4D and 5D specimens showed similar cyclic flexural responses.Finally,a 3D finite element model that can predict the monotonic and cyclic flexural responses of the double-hooked-end SFRC was developed.The calibration process considered the results obtained from the inverse analysis to determine the tensile behavior of the SFRC. 展开更多
关键词 steel fiber reinforced concrete fiber geometry cyclic loading energy dissipation finite element modeling inverse analysis
原文传递
Effect of seismic design details on hysteresis performance of SRC-RC transfer columns 被引量:1
12
作者 Wu Kai Zhai Jiangpeng +2 位作者 Xue Jianyang Zhao Hongtie Chen Feng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第1期117-135,共19页
Four types of seismic design details were tested using 11 transfer column specimens and one comparison specimen of RC under low cyclic reversed loading. Test results show that diagonal cracks control the failure patte... Four types of seismic design details were tested using 11 transfer column specimens and one comparison specimen of RC under low cyclic reversed loading. Test results show that diagonal cracks control the failure pattern and damage occurs mainly in the RC section with weak shear capacity in the transfer columns. There is a large difference in the bearing capacity and ductility of the transfer columns according to the test results, which indicates that the strengthening effect of diverse structural measures is quite different. The section ratio of I-section-encased steel and the axial compression ratio also have a great influence on the bearing capacity and ductility. Although the bearing capacity of transfer columns with additional longitudinal bars and additional X bars is relatively large, they have poor deformation capacity. Setting more stirrups along the columns is the best structural measure to enhance the seismic performance. The studs on the I-sectionencased steel by welding can help to complete the stress transfer between the steel and concrete, and avoid performance degradation of the two materials due to bonding failure. 展开更多
关键词 seismic design details hysteresis performance steel reinforced concrete transfer column energy dissipation
下载PDF
Test on mechanical behavior of SRC L-shaped columns under combined torsion and bending moment 被引量:1
13
作者 Chen Zongping Ning Fan +2 位作者 Chen Jianjia Liu Xiang Xu Dingyi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第1期161-177,共17页
Investigations of the seismic behavior of steel reinforced concrete L-shaped columns under constant axial compression and cycled bending-shear-torsion load were performed.Six specimens,which considered two parameters,... Investigations of the seismic behavior of steel reinforced concrete L-shaped columns under constant axial compression and cycled bending-shear-torsion load were performed.Six specimens,which considered two parameters,i.e.,the moment ratio of torsion to bending(γ)and the aspect ratio(column length-to-depth ratio,φ),were prepared for the experiment.In this study,the failure process,torsion-displacement hysteresis curves,and flexure-displacement hysteresis curves were obtained.The failure characteristics,mechanical behavior of specimens such as the failure patterns,hysteresis curves,rigidity degradation,ductility and energy dissipation,are analyzed.The experimental research indicated that the major failures of the specimens were bending failure,bending-shear failure and bending-torsion failure as the moment ratio of torsion to bending(γ)increased.The torsion-displacement hysteresis curves were pinched in the middle,formed a slip platform,and the phenomenon of“load drop”occurred after the peak load.The bending-displacement hysteresis curves were plump,which showed that bending capacity of the specimen was better than its torsion capacity.Additionally,the energy dissipation of the specimen was dominated by torsion in the early stage and ultimately governed by the bending moment in the later phase.Test results also indicated that the displacement ductility coefficient and interstory rotation angle of the failure point were less than 3.0 and 1/50,respectively,which means the test specimen performance does not meet the requirement of the Chinese Code for Seismic Design of Buildings(GB 50011-2014)in this respect. 展开更多
关键词 compression-bending-shear-torsion combined action steel reinforced concrete(SRC) L-shaped columns seismic behavior
下载PDF
A precise solution for prediction of fiber-reinforced concrete behavior under flexure 被引量:1
14
作者 R.AHMADI P.GHODDOUSI +1 位作者 M.SHARIFI V.Mojarrad BAHREH 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2011年第7期495-502,共8页
This paper presents a precise solution to predict the behavior of steel fiber reinforced concrete(SFRC) under the four point bending test(FPBT).All the force components at the beam section(before and after cracking) a... This paper presents a precise solution to predict the behavior of steel fiber reinforced concrete(SFRC) under the four point bending test(FPBT).All the force components at the beam section(before and after cracking) are formulated by applying these assumptions:a realistic stress-strain model is used for concrete behavior in compression,a linear response is considered for the uncracked tension region in a concrete constitutive model,and an exponential relationship is proposed as a stress-crack opening in the crack region which requires two parameters.Then the moment capacity of the critical cracked section is calculated by using these forces and satisfying equilibrium law at the section.Parametric studies are done on the behavior of SFRC to assess the sensitivity of the solution.Finally,this solution is validated with some existing experimental data.The result shows the proposed solution is able to estimate the behavior of SFRC under FPBT. 展开更多
关键词 steel fiber reinforced concrete(SFRC) Flexure Stress-crack opening Four point bending test(FPBT)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部