期刊文献+
共找到63,526篇文章
< 1 2 250 >
每页显示 20 50 100
Insights into the hydrogen evolution reaction in vanadium redox flow batteries:A synchrotron radiation based X-ray imaging study
1
作者 Kerstin Köble Alexey Ershov +7 位作者 Kangjun Duan Monja Schilling Alexander Rampf Angelica Cecilia TomášFaragó Marcus Zuber Tilo Baumbach Roswitha Zeis 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第4期132-144,共13页
The parasitic hydrogen evolution reaction(HER)in the negative half-cell of vanadium redox flow batteries(VRFBs)causes severe efficiency losses.Thus,a deeper understanding of this process and the accompanying bubble fo... The parasitic hydrogen evolution reaction(HER)in the negative half-cell of vanadium redox flow batteries(VRFBs)causes severe efficiency losses.Thus,a deeper understanding of this process and the accompanying bubble formation is crucial.This benchmarking study locally analyzes the bubble distribution in thick,porous electrodes for the first time using deep learning-based image segmentation of synchrotron X-ray micro-tomograms.Each large three-dimensional data set was processed precisely in less than one minute while minimizing human errors and pointing out areas of increased HER activity in VRFBs.The study systematically varies the electrode potential and material,concluding that more negative electrode potentials of-200 m V vs.reversible hydrogen electrode(RHE)and lower cause more substantial bubble formation,resulting in bubble fractions of around 15%–20%in carbon felt electrodes.Contrarily,the bubble fractions stay only around 2%in an electrode combining carbon felt and carbon paper.The detected areas with high HER activity,such as the border subregion with more than 30%bubble fraction in carbon felt electrodes,the cutting edges,and preferential spots in the electrode bulk,are potential-independent and suggest that larger electrodes with a higher bulk-to-border ratio might reduce HER-related performance losses.The described combination of electrochemical measurements,local X-ray microtomography,AI-based segmentation,and 3D morphometric analysis is a powerful and novel approach for local bubble analysis in three-dimensional porous electrodes,providing an essential toolkit for a broad community working on bubble-generating electrochemical systems. 展开更多
关键词 Vanadium redox flow battery synchrotron X-ray imaging Tomography Hydrogen evolution reaction Gas bubbles Deep learning
下载PDF
L-shell x-ray fluorescence relative intensities for elements with 62≤Z≤83 at 18 keV and 23 keV by synchrotron radiation
2
作者 M Alqadi S AL-Humaidi +1 位作者 H Alkhateeb F Alzoubi 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期270-273,共4页
The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of... The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of the Synchrotron Light Center for Experimental Science and Applications in the Middle East(SESAME),Jordan.The experimentally measured results of the relative intensities were compared with the calculated results using the subshell fluorescence yield and the Coster-Kronig transition probabilities recommended by Campbell and the values based on the Dirac-Hartree-Slater model by Puri.The experimental and theoretical results are in agreement.In this work,L XRF relative intensities for the elements Sm,Gd,Tb,Er,Ta,W,Re,Hg,Pb and Bi at energies of 18 keV and 23 keV were measured. 展开更多
关键词 L shell x-ray fluorescence(XRF) relative intensities synchrotron radiation
原文传递
The biosafety level-2 macromolecular crystallography beamline(BL10U2)at the Shanghai Synchrotron Radiation Facility
3
作者 Qin Xu Hua‑Ting Kong +10 位作者 Ke Liu Huan Zhou Kun‑Hao Zhang Wei‑Wei Wang Min‑Jun Li Qiang‑Yan Pan Xing‑Ya Wang Yu‑Zhu Wang Feng Yu Xing‑Yu Gao Qi‑Sheng Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期251-263,共13页
BL10U2 is an undulator-based macromolecular crystallography(MX)beamline located at the 3.5-GeV Shanghai Synchrotron Radiation Facility.BL10U2 is specifically designed for conducting routine and biosafety level-2(BSL-2... BL10U2 is an undulator-based macromolecular crystallography(MX)beamline located at the 3.5-GeV Shanghai Synchrotron Radiation Facility.BL10U2 is specifically designed for conducting routine and biosafety level-2(BSL-2)MX experiments utilizing high-flux tunable X-rays with energies from 7 to 18 keV,providing a beam spot size of 20μm(horizontal)×10μm(vertical)at the sample point.Certification by the Shanghai Pudong Municipal Health Commission confirmed the capability to perform BSL-2 MX experiments.The beamline is currently equipped with an Eiger X 16 M detector and two newly developed in-house high-precision diffractometers that can be switched to perform conventional or in situ crystal diffraction experiments.An automatic sample changer developed in-house allows fast sample exchange in less than 30 s,supporting high-throughput MX experimentation and rapid crystal screening.Data collection from both the diffractometer and detector was controlled by an in-house developed data collection software(Finback)with a user-friendly interface for convenient operation.This study presents a comprehensive overview of the facilities,experimental methods,and performance characteristics of the BL10U2 beamline. 展开更多
关键词 Shanghai synchrotron radiation Facility BSL-2 MX beamline BL10U2
下载PDF
BL02U1:the relocated macromolecular crystallography beamline at the Shanghai Synchrotron Radiation Facility
4
作者 Ke Liu Huan Zhou +9 位作者 Qin Xu Hua‑Ting Kong Kun‑Hao Zhang Wei‑Wei Wang Min‑Jun Li Zhi‑Jun Wang Qiang‑Yan Pan Xing‑Ya Wang Feng Yu Qi‑Sheng Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期146-155,共10页
Macromolecular crystallography beamline BL17U1 at the Shanghai Synchrotron Radiation Facility has been relocated,upgraded,and given a new ID(BL02U1).It now delivers X-rays in the energy range of 6–16 keV,with a focus... Macromolecular crystallography beamline BL17U1 at the Shanghai Synchrotron Radiation Facility has been relocated,upgraded,and given a new ID(BL02U1).It now delivers X-rays in the energy range of 6–16 keV,with a focused beam of 11.6μm×4.8μm and photon flux greater than 1012 phs/s.The high credibility and stability of the beam and good timing synchronization of the equipment significantly improve the experimental efficiency.Since June 2021,when it officially opened to users,over 4200 h of beamtime have been provided to over 200 research groups to collect data at the beamline.Its good performance and stable operation have led to the resolution of several structures based on data collected at the beamline. 展开更多
关键词 Macromolecular crystallography beamline Shanghai synchrotron radiation Facility BL02U1
下载PDF
The effect of temperature on load partitioning evolution in magnesium metal matrix composite reinforced with Ti particles using in-situ synchrotron radiation diffraction experiments
5
作者 G.Garces J.Medina +3 位作者 P.Perez A.Stark N.Schell P.Adeva 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2023年第2期706-719,共14页
The load partitioning between the magnesium and titanium phases in an extruded Mg-15%Ti(vol.%) composite from room temperature up to 300 ℃ using synchrotron radiation diffraction during in-situ compression tests. Dur... The load partitioning between the magnesium and titanium phases in an extruded Mg-15%Ti(vol.%) composite from room temperature up to 300 ℃ using synchrotron radiation diffraction during in-situ compression tests. During compression, the magnesium matrix composite deforms mainly by the activation of the extension twinning system up to 200 ℃. The volume fraction of twins increases with the plastic strain but decrease with the compression temperature. Hard titanium particles bear an additional load transferred by the soft magnesium matrix from room temperature up to 300 ℃. This effect is amplified after yield stress during plastic deformation. Additionally, twins within magnesium grains behaves as an additional reinforcement at low temperature(below 200 ℃) inducing an increase in the work hardening of the composite. 展开更多
关键词 Magnesium alloys In-situ synchrotron radiationdiffraction PLASTICITY Precipitation Dislocationslip TWINNING
下载PDF
Synchrotron radiation-based materials characterization techniques shed light on molten salt reactor alloys 被引量:6
6
作者 Li Jiang Xiang-Xi Ye +1 位作者 De-Jun Wang Zhi-Jun Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第1期57-71,共15页
From a safety point of view, it is important to study the damages and reliability of molten salt reactor structural alloy materials, which are subjected to extreme environments due to neutron irradiation, molten salt ... From a safety point of view, it is important to study the damages and reliability of molten salt reactor structural alloy materials, which are subjected to extreme environments due to neutron irradiation, molten salt corrosion, fission product attacks, thermal stress, and even combinations of these. In the past few years, synchrotron radiation-based materials characterization techniques have proven to be effective in revealing the microstructural evolution and failure mechanisms of the alloys under surrogating operation conditions. Here, we review the recent progress in the investigations of molten salt corrosion,tellurium(Te) corrosion, and alloy design. The valence states and distribution of chromium(Cr) atoms, and the diffusion and local atomic structure of Te atoms near the surface of corroded alloys have been investigated using synchrotron radiation techniques, which considerably deepen the understandings on the molten salt and Te corrosion behaviors. Furthermore, the structure and size distribution of the second phases in the alloys have been obtained, which are helpful for the future development of new alloy materials. 展开更多
关键词 Molten salt reactor Alloy materials synchrotron radiation Shanghai synchrotron radiation Facility Molten salt corrosion Tellurium corrosion
下载PDF
Hot deformation of Mg-Y-Zn alloy with a low content of the LPSO phase studied by in-situ synchrotron radiation diffraction 被引量:5
7
作者 Klaudia Horváth Fekete Daria Drozdenko +5 位作者 Jan Capek Kristián Máthis Domonkos Tolnai Andreas Stark Gerardo Garcés Patrik Dobron 《Journal of Magnesium and Alloys》 SCIE 2020年第1期199-209,共11页
The compressive deformation behavior of the extruded WZ42(Mg98.5Y1Zn0.5 in at.%)magnesium alloy containing a low amount of long-period stacking ordered(LPSO)phase was studied by in-situ synchrotron radiation diffracti... The compressive deformation behavior of the extruded WZ42(Mg98.5Y1Zn0.5 in at.%)magnesium alloy containing a low amount of long-period stacking ordered(LPSO)phase was studied by in-situ synchrotron radiation diffraction technique.Tests were conducted at temperatures between room temperature and 350℃.Detailed microstructure investigation was provided by scanning electron microscopy,particularly the backscattered electron imaging and electron backscatter diffraction technique.The results show that twinning lost its dominance and kinking of the LPSO phase became more pronounced with increasing deformation temperature.No cracks of the LPSO phase and no debonding r at the interface between the LPSO phase and the Mg matrix were observed at temperatures above 200℃.At 350℃,the LPSO phase lost its strengthening effect and the deformation of the alloy was mainly realized by the dynamic recrystallization of the Mg matrix. 展开更多
关键词 Magnesium alloy LPSO phase KINKING High temperature synchrotron radiation diffraction
下载PDF
Small-angle X-ray scattering investigation of aging behavior of Al-Cu-Mg-Ag alloys using synchrotron radiation 被引量:2
8
作者 Zhang Jianbo Zhang Yongan +3 位作者 Zhu Baohong Liu Ruiqing Li Zhihui Li Xiwu 《Rare Metals》 SCIE EI CAS CSCD 2012年第6期537-540,共4页
The aging behavior of Al-Cu-Mg-Ag alloys with high Cu/Mg was studied by transmission electron microscopy (TEM) and small-angle X-ray scattering (SAXS) using synchrotron radiation. TEM study reveals that the major stre... The aging behavior of Al-Cu-Mg-Ag alloys with high Cu/Mg was studied by transmission electron microscopy (TEM) and small-angle X-ray scattering (SAXS) using synchrotron radiation. TEM study reveals that the major strengthening phases of the alloy after aging at 160?C for 10 h are Ω and less θ′. SAXS study shows that the scattering patterns are composed of several concentric circles at the beginning of aging process, which is replaced by the butterfly-wings scattering patterns with the increase of aging time. The butterfly-wings scattering patterns are composed of several branches. The angles between the branches are roughly equal to that between the habit planes of precipitates. The evolution of Guinier radius with aging time indicates the good coarsening resistance of the precipitates. The evolution of integrated intensity is consistent with the classical two-step precipitation process. 展开更多
关键词 Al-Cu-Mg-Ag alloys precipitate size synchrotron radiation small angle X-ray scattering
下载PDF
Characterization of metal element distributions in the rat brain following ischemic stroke by synchrotron radiation microfluorescence analysis 被引量:2
9
作者 Shu-Peng Shi Hui Wang +3 位作者 Zhuo-Hui Chen Xiao-Han Li Shi-Xin Liu Meng-Qi Zhang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第10期1-12,共12页
Ischemic stroke is one of the leading causes of death worldwide,and effective treatment strategies in the chronic phase of this disease remain insufficient.Homeostasis of metals in the brain plays an important role in... Ischemic stroke is one of the leading causes of death worldwide,and effective treatment strategies in the chronic phase of this disease remain insufficient.Homeostasis of metals in the brain plays an important role in maintaining normal brain function.However,the dynamic spatial distributions of iron,zinc,calcium,potassium,and copper in a rat brain following ischemic stroke and the association between structural distribution and function remain to be elucidated.In this study,we used a synchrotron radiation-based micro-X-ray fluorescence technique to image element mapping changes in special rat brain regions after ischemic stroke,showing the distribution characteristics of iron,zinc,calcium,potassium,and copper.We demonstrated,for the first time,the consistent dynamic spatial distributions of metal elements at a series of time points(3 h,4.5 h,6 h,12 h,1 d,3 d,5 d,7 d,10 d,14 d,28 d)after brain ischemia,which revealed that the homeostasis of iron,zinc,calcium,potassium,and copper in the brain was disturbed with distinctive change trends,providing clear insights in understanding the underlying pathogenesis of stroke from a novel perspective,thus laying the foundation of further developing new drug targets for stroke treatment. 展开更多
关键词 Ischemic stroke synchrotron radiation X-ray fluorescence METAL Rat brain
下载PDF
Picosecond time-resolved X-ray ferromagnetic resonance measurements at Shanghai synchrotron radiation facility 被引量:1
10
作者 Xia Yang Jie-Feng Cao +6 位作者 Jun-Qin Li Fang-Yuan Zhu Rui Yu Jian He Zi-Long Zhao Yong Wang Ren-Zhong Tai 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第5期126-134,共9页
An experimental picosecond time-resolved X-ray ferromagnetic resonance(TR-XFMR)apparatus with a time resolution of 13 ps(RMS)or 31 ps(FWHM)was constructed and demonstrated in the 07U and 08U1A soft X-ray beamlines at ... An experimental picosecond time-resolved X-ray ferromagnetic resonance(TR-XFMR)apparatus with a time resolution of 13 ps(RMS)or 31 ps(FWHM)was constructed and demonstrated in the 07U and 08U1A soft X-ray beamlines at the Shanghai Synchrotron Radiation Facility(SSRF)using pump-probe detection and X-ray magnetic circular dichroism(XMCD)spectroscopy.Element and time-resolved ferromagnetic resonance was excited by continuous microwave phase-locking of the bunch clock within the photon beam during synchrotron radiation and was characterized by detecting the magnetic circular dichroism signals of the elements of interest in the magnetic films.Using this equipment,we measured the amplitude of the element-specific moment precession during ferromagnetic resonance(FMR)at 2 GHz in a single Ni81Fe19layer. 展开更多
关键词 Ferromagnetic resonance Time resolution PUMP-PROBE synchrotron radiation
下载PDF
The protein complex crystallography beamline(BL19U1)at the Shanghai Synchrotron Radiation Facility 被引量:9
11
作者 Wei-Zhe Zhang Jian-Chao Tang +3 位作者 Si-Sheng Wang Zhi-Jun Wang Wen-Ming Qin Jian-Hua He 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第11期30-40,共11页
The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai... The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai,China).The beamline,which features a small-gap invacuum undulator,has been officially open to users since March 2015.This beamline delivers X-ray in the energy range 7–15 keV.With its high flux,low divergence beam and a large active area detector,BL19U1 is designed for proteins with large molecular weight and large crystallographic unit cell dimensions.Good performance and stable operation of the beamline have allowed the number of Protein Data Bank(PDB)depositions and the number of articles published based on data collected at this beamline to increase steadily.To date,over 300 research groups have collected data at the beamline.More than 600 PDB entries have been deposited at the PDB(www.pdb.org).More than 300 papers have been published that include data collected at the beamline,including 21 research articles published in the top-level journals Cell,Nature,and Science. 展开更多
关键词 MX BEAMLINES Macromolecular CRYSTALLOGRAPHY Shanghai synchrotron radiation Facility SSRF-BL19U1
下载PDF
Design of wide-range energy material beamline at the Shanghai Synchrotron Radiation Facility 被引量:3
12
作者 Zhen-Hua Chen Fan-Fei Sun +5 位作者 Ying Zou Fei Song Shuo Zhang Zheng Jiang Yong Wang Ren-Zhong Tai 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第2期91-102,共12页
We report the design of a wide-range energy material beamline(E-line) with multiple experimental techniques at the Shanghai Synchrotron Radiation Facility.The undulators consisted of an elliptically polarizing undulat... We report the design of a wide-range energy material beamline(E-line) with multiple experimental techniques at the Shanghai Synchrotron Radiation Facility.The undulators consisted of an elliptically polarizing undulator and in-vacuum undulator that generate the soft and hard X-rays, respectively. The beamline covered a wide energy range from 130 to 18 ke V with both a high photon flux([ 10^(12) phs/s with exit silt 30 lm in soft X-ray and [ 5 9 10^(12) phs/s in hard X-ray within 0.1%BW bandwidth) and promising resolving power(maximum E/DE [ 15,000 in soft X-ray with exit silt 30 lm and [6000 in hard X-ray). Moreover, the beam spots from the soft and hard X-rays were focused to the same sample position with a high overlap ratio, so that the surfaces, interfaces, and bulk properties were characterized in situ by changing the probing depth. 展开更多
关键词 synchrotron radiation BEAMLINE WIDE energy range E-line Shanghai synchrotron radiation FACILITY
下载PDF
Tuning control system of a third harmonic superconducting cavity in the Shanghai Synchrotron Radiation Facility 被引量:4
13
作者 Peng-Peng Gong Yu-Bin Zhao +6 位作者 Hong-Tao Hou Zhi-Gang Zhang Xiang Zheng Xiao-Yun Pu Kai Xu Qiang Chang Jian-Fei Liu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第10期123-132,共10页
Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge densit... Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge density of the bench.In the phaseⅡupgrade of the SSRF,a third harmonic superconducting cavity will be used to enhance the Touschek lifetime by lengthening the bunches.The Touschek lifetime improvement factor is affected by the voltage of a harmonic cavity.To stabilize the cavity voltage,a tuning control system was designed to control it.The design of the tuning control system was based on the SSRF third-generation low-level RF control system.Some hardware and specialized algorithms were redesigned to fit the harmonic cavity control.The design of the tuning control system is complete,and the control system has been tested.The test result shows that the fluctuation of amplitude is<±0.34%within 1.5 h,which satisfies the stability requirement. 展开更多
关键词 Passive HARMONIC CAVITY Low-level radio frequency Shanghai synchrotron radiation FACILITY Touschek LIFETIME
下载PDF
Three dimensional distribution of surfactant in microspheres revealed by synchrotron radiation X-ray microcomputed tomography 被引量:2
14
作者 Li Wu Manli Wang +7 位作者 Vikramjeet Singh Haiyan Li Zhen Guo Shuangying Gui Peter York Tiqiao Xiao Xianzhen Yin Jiwen Zhang 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2017年第4期326-334,共9页
This study investigated the formulation mechanism of microspheres via internal surfactant distribution. Eudragit L100 based microspheres loaded with bovine serum albumin were prepared by solid in oil in oil emulsion s... This study investigated the formulation mechanism of microspheres via internal surfactant distribution. Eudragit L100 based microspheres loaded with bovine serum albumin were prepared by solid in oil in oil emulsion solvent evaporation method using acetone and liquid paraffin system containing sucrose stearate as a surfactant. The fabricated microspheres were evaluated for encapsulation efficiency, particle size, production yield, and in vitro release characteristics. The internal structures of microspheres were characterized using synchrotron radiation X-ray microcomputed tomography(SR-μCT). The enhanced contrast made the sucrose stearate distinguished from Eudragit to have its three dimensional(3D) distribution. Results indicated that the content and concentration determined the state of sucrose stearate and had significant influences on the release kinetics of protein. The dispersity of sucrose stearate was the primary factor that controlled the structure of the microspheres and further affected the encapsulation efficiency, effective drug loading, as well as in vitro release behavior. In conclusion, the 3D internal distribution of surfactant in microspheres and its effects on protein release behaviors have been revealed for the first time. The highly resolved 3D architecture provides new evidence for the deep understanding of the microsphere formation mechanism. 展开更多
关键词 Three dimensional synchrotron radiation X-RAY microcomputed tomography DISTRIBUTION MICROSPHERE SUCROSE STEARATE
下载PDF
Synchrotron Radiation Lithography and MEMS Technique at NSRL 被引量:1
15
作者 LIU Gang, TIAN Yang chao (National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, 230029, China) 《光学精密工程》 EI CAS CSCD 2001年第5期455-457,共3页
Two beamlines and stations for soft X-ray lithography and hard X-ray lithography at NSRL are presented. Synchrotron radiation lithography (SRL) and mask techniques are developed, and the micro-electro-mechanical syste... Two beamlines and stations for soft X-ray lithography and hard X-ray lithography at NSRL are presented. Synchrotron radiation lithography (SRL) and mask techniques are developed, and the micro-electro-mechanical systems (MEMS) techniques are also investigated at NSRL. In this paper, some results based on SRL and MEMS techniques are reported, and sub-micron and high aspect ratio microstructures are given. Some micro-devices, such as microreactors are fabricated at NSRL. 展开更多
关键词 synchrotron radiation LITHOGRAPHY (SRL) MEMS MICROREACTORS
下载PDF
High pressure x-ray diffraction techniques with synchrotron radiation 被引量:6
16
作者 刘景 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第7期9-21,共13页
This article summarizes the developments of experimental techniques for high pressure x-ray diffraction(XRD) in diamond anvil cells(DACs) using synchrotron radiation. Basic principles and experimental methods for vari... This article summarizes the developments of experimental techniques for high pressure x-ray diffraction(XRD) in diamond anvil cells(DACs) using synchrotron radiation. Basic principles and experimental methods for various diffraction geometry are described, including powder diffraction, single crystal diffraction, radial diffraction, as well as coupling with laser heating system. Resolution in d-spacing of different diffraction modes is discussed. More recent progress, such as extended application of single crystal diffraction for measurements of multigrain and electron density distribution, timeresolved diffraction with dynamic DAC and development of modulated heating techniques are briefly introduced. The current status of the high pressure beamline at BSRF(Beijing Synchrotron Radiation Facility) and some results are also presented. 展开更多
关键词 北京同步辐射装置 X射线衍射技术 高压X射线衍射 金刚石对顶砧 电子密度分布 单晶衍射 加热系统 实验技术
原文传递
Synchrotron radiation investigations of the Sr_2MgSi_2O_7:Eu^(2+),R^(3+) persistent luminescence materials 被引量:5
17
作者 Tuomas Aitasalo Jukka Hassinen +5 位作者 Jorma Hls Taneli Laamanen Mika Lastusaari Marja Malkamki Janne Niittykoski Pavel Novák 《Journal of Rare Earths》 SCIE EI CAS CSCD 2009年第4期529-538,共10页
The electronic and defect energy level structure of polycrystalline Sr2MgSi2O7:Eu2+,R3+ persistent luminescence materials were studied with thermoluminescence and different synchrotron radiation spectroscopies (UV-VUV... The electronic and defect energy level structure of polycrystalline Sr2MgSi2O7:Eu2+,R3+ persistent luminescence materials were studied with thermoluminescence and different synchrotron radiation spectroscopies (UV-VUV emission and excitation, X-ray absorption near-edge spectroscopy (XANES) and extended X-ray absorption fine structure (EXAFS)). Special attention was paid on the effect of the R3+ co-dopants on the persistent luminescence properties of the materials. Theoretical calculations using the density functional theory (DFT) were carried out simultaneously with the experimental work. The experimental band gap energy (Eg) value of ca. 7.1 eV agreed very well with the DFT value of 6.7 eV. The variation of the Eg value was attempted to relate with the trap structure as well as with the different properties of the R3+ co-dopants. The trap level energy distribution depended strongly on the R3+ co-dopant except for the shallowest trap energy above the room temperature remaining practically the same, however. The different processes in the mechanism of persistent luminescence from Sr2MgSi2O7:Eu2+,R3+ were assembled and their contributions discussed. 展开更多
关键词 发光材料 光同步 辐射调查 真空紫外发射 密度泛函理论 X射线吸收 XANES谱
下载PDF
Polycapillary X-ray lens for the secondary focusing Beijing synchrotron radiation source 被引量:3
18
作者 李玉德 林晓燕 +4 位作者 刘世岗 何金龙 郭非 孙天希 刘鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第4期248-252,共5页
According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotr... According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results. 展开更多
关键词 同步辐射光源 X光透镜 毛细管 北京 聚焦 传输效率 强度分布 光学元件
原文传递
Potential applications of synchrotron radiation to the treatment of cancer 被引量:1
19
作者 SHI Zeliang ZHOU Shuhui FU Shen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2013年第1期1-6,共6页
Although conventional radiotherapy remains to be one of the most useful treatments for cancer, it is not the best strategy to maximize the effects on the tumors and minimize the damage to the surrounding tissues due t... Although conventional radiotherapy remains to be one of the most useful treatments for cancer, it is not the best strategy to maximize the effects on the tumors and minimize the damage to the surrounding tissues due to its physical and biological characteristics. Synchrotron radiation (SR) with uniquely physical and biological advantages may represent an innovative approach for cancer treatment. In recent years, SR-based photon activation therapy, stereotactic synchrotron radiation therapy and micro-beam radiation treatment have been developed, and the results of in vitro and in vivo experiments are very promising. It is necessary to understand the physical and radiobiological principle of those novel strategies before the approach is applied to the clinic. In this paper, we summarize the advances of SR in terms of physical, radiobiological advantages and its potential clinical applications. With the successful operation of shanghai synchrotron radiation, good opportunities in China have been provided for investigations on the treatment of cancer with synchrotron radiation. 展开更多
关键词 同步加速器 辐射治疗 临床应用 癌症 同步辐射光源 放射生物学 放射治疗 生物特性
下载PDF
Internal Structure of Cambrian Fossil Embryo Markuelia Revealed in the Light of Synchrotron Radiation X-ray Tomographic Microscopy 被引量:4
20
作者 CHENG Gong PENG Fan +1 位作者 DUAN Baichuan DONG Xiping 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2011年第1期81-90,共10页
根据同步加速器放射 X 光检查 Tomographic 显微镜学(SRXTM ) , Markuelia hunanensis 的内部结构被揭示。在一个例子,玻璃化和脱皮的表演在卵壳下面隐藏的 annuli。Sectioning 和 3-D 重建从转换内向的人显示一条未经触动的消化的道... 根据同步加速器放射 X 光检查 Tomographic 显微镜学(SRXTM ) , Markuelia hunanensis 的内部结构被揭示。在一个例子,玻璃化和脱皮的表演在卵壳下面隐藏的 annuli。Sectioning 和 3-D 重建从转换内向的人显示一条未经触动的消化的道到终端肛门。转换内向的人形成橄榄球 cavum。下列消化的道是像绳的卷,平行到身体轴,在长度的大约 650 m,和在直径(80 m ) 的制服。精致地保存的像管子的结构在像绳的结构的中间被隐藏,直径 2040 m,与一段 120 m。我们作为肌的可能的残余作为内脏和它的环境的可能的外皮解释这像管子的结构,类似于那在 Priapulans。连接身体墙和消化的道的二对称的杆形状结构作为可能的缩肌肌肉被解释。在比较左形式的保存的井和 Markuelia 的正确形式的身体以后,我们建议他们可以代表同种二形。直接数了, Markuelia hunanensis 的一件样品拥有 62 个环和其它 68。 展开更多
关键词 Markuelia 同步加速器放射 X 光检查 Tomographic 显微镜学(SRXTM ) 同种二形
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部