An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse.A simple theoretical model based on power balance is used to design the ...An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse.A simple theoretical model based on power balance is used to design the shape of the drive laser pulse.Experiments are carried out on the Shenguang III prototype laser facility,and the experimental results are presented for radiation sources with the flat-top lasting about 2.5 ns at two diferent peak temperatures of about150 eV and 170 eV,respectively,including the time histories of the temperatures,the shapes of the drive laser pulses and the time integrated radiation spectra.The validity of the model and possible improvements are discussed.展开更多
Besides the original seeded undulator line,in the soft X-ray free-electron laser(SXFEL) user facility in Shanghai,a second undulator line based on self-amplified spontaneous emission is proposed to achieve 2-nm laser ...Besides the original seeded undulator line,in the soft X-ray free-electron laser(SXFEL) user facility in Shanghai,a second undulator line based on self-amplified spontaneous emission is proposed to achieve 2-nm laser pulse with extremely high brightness.In this paper,the beam energy deviation induced by the undulator wakefields is numerically calculated,and 3D and 2D results agree well with each other.The beam energy loss along the undulator degrades the expected FEL output performances,i.e.,the pulse energy,radiation power and spectrum,which can be compensated with a proper taper in the undulator.Using the planned time-resolved diagnostic,a novel experiment is proposed to measure the SXFEL longitudinal wakefields.展开更多
An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A ...An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A radiation source with a flattop temperature of about130 e V that lasted about 5 ns was obtained.The previous analytical iteration method based on power balance and self-similar solution of ablation was modified taking into account the plasma movements and it was used to design the laser pulse shape for experiment.A comparison between experimental results and simulation is presented and better agreement was achieved using the modified method.Further improvements are discussed.展开更多
文摘An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse.A simple theoretical model based on power balance is used to design the shape of the drive laser pulse.Experiments are carried out on the Shenguang III prototype laser facility,and the experimental results are presented for radiation sources with the flat-top lasting about 2.5 ns at two diferent peak temperatures of about150 eV and 170 eV,respectively,including the time histories of the temperatures,the shapes of the drive laser pulses and the time integrated radiation spectra.The validity of the model and possible improvements are discussed.
基金supported by the National Natural Science Foundation of China(Nos.11475250 and 11322550)Ten Thousand Talent Program
文摘Besides the original seeded undulator line,in the soft X-ray free-electron laser(SXFEL) user facility in Shanghai,a second undulator line based on self-amplified spontaneous emission is proposed to achieve 2-nm laser pulse with extremely high brightness.In this paper,the beam energy deviation induced by the undulator wakefields is numerically calculated,and 3D and 2D results agree well with each other.The beam energy loss along the undulator degrades the expected FEL output performances,i.e.,the pulse energy,radiation power and spectrum,which can be compensated with a proper taper in the undulator.Using the planned time-resolved diagnostic,a novel experiment is proposed to measure the SXFEL longitudinal wakefields.
文摘An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A radiation source with a flattop temperature of about130 e V that lasted about 5 ns was obtained.The previous analytical iteration method based on power balance and self-similar solution of ablation was modified taking into account the plasma movements and it was used to design the laser pulse shape for experiment.A comparison between experimental results and simulation is presented and better agreement was achieved using the modified method.Further improvements are discussed.