期刊文献+
共找到5,046篇文章
< 1 2 250 >
每页显示 20 50 100
Which approach of total hip arthroplasty is the best efficacy and least complication? 被引量:1
1
作者 Lertkong Nitiwarangkul Natthapong Hongku +3 位作者 Oraluck Pattanaprateep Sasivimol Rattanasiri Patarawan Woratanarat Ammarin Thakkinstian 《World Journal of Orthopedics》 2024年第1期73-93,共21页
BACKGROUND Total hip arthroplasty is as an effective intervention to relieve pain and improve hip function.Approaches of the hip have been exhaustively explored about pros and cons.The efficacy and the complications o... BACKGROUND Total hip arthroplasty is as an effective intervention to relieve pain and improve hip function.Approaches of the hip have been exhaustively explored about pros and cons.The efficacy and the complications of hip approaches remains inconclusive.This study conducted an umbrella review to systematically appraise previous meta-analysis(MAs)including conventional posterior approach(PA),and minimally invasive surgeries as the lateral approach(LA),direct anterior approach(DAA),2-incisions method,mini-lateral approach and the newest technique direct superior approach(DSA)or supercapsular percutaneouslyassisted total hip(SuperPath).AIM To compare the efficacy and complications of hip approaches that have been published in all MAs and randomized controlled trials(RCTs).METHODS MAs were identified from MEDLINE and Scopus from inception until 2023.RCTs were then updated from the latest MA to September 2023.This study included studies which compared hip approaches and reported at least one outcome such as Harris Hip Score(HHS),dislocation,intra-operative fracture,wound compliData were independently selected,extracted and assessed by two reviewers.Network MA and cluster rank and surface under the cumulative ranking curve(SUCRA)were estimated for treatment efficacy and safety.RESULTS Finally,twenty-eight MAs(40 RCTs),and 13 RCTs were retrieved.In total 47 RCTs were included for reanalysis.The results of corrected covered area showed high degree(13.80%).Among 47 RCTs,most of the studies were low risk of bias in part of random process and outcome reporting,while other domains were medium to high risk of bias.DAA significantly provided higher HHS at three months than PA[pooled unstandardized mean difference(USMD):3.49,95%confidence interval(CI):0.98,6.00 with SUCRA:85.9],followed by DSA/SuperPath(USMD:1.57,95%CI:-1.55,4.69 with SUCRA:57.6).All approaches had indifferent dislocation and intraoperative fracture rates.SUCRA comparing early functional outcome and composite complications(dislocation,intra-operative fracture,wound complication,and nerve injury)found DAA was the best approach followed by DSA/SuperPath.CONCLUSION DSA/SuperPath had better earlier functional outcome than PA,but still could not overcome the result of DAA.This technique might be the other preferred option with acceptable complications. 展开更多
关键词 total hip arthroplasty total hip replacement APPROACH Supercapsular percutaneously-assisted total hip Harris hip Score Intra-operative fracture
下载PDF
Offset restoration in total hip arthroplasty:Important:A current review
2
作者 Anil Thomas Oommen 《World Journal of Orthopedics》 2024年第8期696-703,共8页
Normal vertical and horizontal offset is essential for hip biomechanics,muscle functioning and gait pattern.Total hip arthroplasty(THA)should aim to restore normal offset with implantation of femoral and acetabular co... Normal vertical and horizontal offset is essential for hip biomechanics,muscle functioning and gait pattern.Total hip arthroplasty(THA)should aim to restore normal offset with implantation of femoral and acetabular components.This would be possible with proper preoperative planning,templating and ensuring implant options are available for offset restoration.Templating is essential for understanding the vertical and horizontal offset change,especially in hip arthritis presenting late with significant limb length discrepancy at THA.Planning should include appropriate soft tissue releases and the use of ideal implants to achieve restoration of horizontal and vertical offset.Under correction of horizontal offset at THA for fracture neck of femur could result in abductor fatigue,limp and increased wear.Restoration of horizontal offset is imperative at THA for a fractured neck of the femur to achieve optimal abductor function.Horizontal offset is necessary for optimal abductor muscle tension and function.Revision THA for acetabular bone loss would require hip center restoration with the acetabular and femoral offset correction to achieve limb length correction and abductor length.The inability to achieve vertical and horizontal offset correction could lead to dislocation or signs of abductor fatigue.Careful vertical and horizontal femur offset restoration is required for normal hip biomechanics,decreased wear and increased longevity. 展开更多
关键词 OFFSET VERTICAL HORIZONTAL total hip arthroplasty TEMPLATING RESTORATION
下载PDF
Dislocation of primary total hip arthroplasty:Analysis of risk factors and preventive options
3
作者 Dario Regis Mattia Cason Bruno Magnan 《World Journal of Orthopedics》 2024年第6期501-511,共11页
Total hip arthroplasty(THA)is one of the most successful elective operations in orthopedic surgery for improving pain and functional disability in patients with end-stage joint disease.However,dislocation continues to... Total hip arthroplasty(THA)is one of the most successful elective operations in orthopedic surgery for improving pain and functional disability in patients with end-stage joint disease.However,dislocation continues to be a troublesome complication after THA,as it is a leading cause of revision and is associated with substantial social,health,and economic costs.It is a relatively rare,usually early occurrence that depends on both the patients’characteristics and the surgical aspects.The most recent and important finding is the special attention to be given preoperatively to spinopelvic mobility,which is closely related to the incidence of dislocation.Consequently,clinical and radiographic assessment of the lumbar spine is mandatory to identify an altered pelvic tilt that could suggest a different positioning of the cup.Lumbar spinal fusion is currently considered a risk factor for dislocation and revision regardless of whether it is performed prior to or after THA.Surgical options for its treatment and prevention include the use of prostheses with large diameter of femoral head size,dual mobility constructs,constrained liners,and modular neck stems. 展开更多
关键词 DISLOCATION total hip arthroplasty Revision surgery REVIEW Risk factors COMPLICATION
下载PDF
Effects of ulinastatin combined with dexmedetomidine on cognitive dysfunction and emergence agitation in elderly patients who underwent total hip arthroplasty
4
作者 Qi-Fan Huo Li-Juan Zhu +2 位作者 Jian-Wei Guo Yan-An Jiang Jing Zhao 《World Journal of Psychiatry》 SCIE 2024年第1期26-35,共10页
BACKGROUND With the continuous growth of the modern elderly population,the risk of fracture increases.Hip fracture is a common type of fracture in older people.Total hip arthroplasty(THA)has significant advantages in ... BACKGROUND With the continuous growth of the modern elderly population,the risk of fracture increases.Hip fracture is a common type of fracture in older people.Total hip arthroplasty(THA)has significant advantages in relieving chronic pain and promoting the recovery of hip joint function.AIM To investigate the effect of ulinastatin combined with dexmedetomidine(Dex)on the incidences of postoperative cognitive dysfunction(POCD)and emergence agitation in elderly patients who underwent THA.METHODS A total of 397 patients who underwent THA from February 2019 to August 2022.We conducted a three-year retrospective cohort study in Shaanxi Provincial People’s Hospital.Comprehensive demographic data were obtained from the electronic medical record system.We collected preoperative,intraoperative,and postoperative data.One hundred twenty-nine patients who were administered Dex during the operation were included in the Dex group.One hundred fifty patients who were intravenously injected with ulinastatin 15 min before anesthesia induction were included in the ulinastatin group.One hundred eighteen patients who were administered ulinastatin combined with Dex during the operation were included in the Dex+ulinastatin group.The patients’perioperative conditions,hemodynamic indexes,postoperative Mini-Mental State Examination(MMSE)scores,Ramsay score,incidence of POCD,and serum inflammatory cytokines were evaluated.RESULTS There was a significant difference in the 24 h visual analogue scale score among the three groups,and the score in the Dex+ulinastatin group was the lowest(P<0.05).Compared with the Dex and ulinastatin group,the MMSE scores of the Dex+ulinastatin group were significantly increased at 1 and 7 d after the operation(all P<0.05).Compared with those in the Dex and ulinastatin groups,incidence of POCD,levels of serum inflammatory cytokines in the Dex+ulinastatin group were significantly decreased at 1 and 7 d after the operation(all P<0.05).The observer’s assessment of the alertness/sedation score and Ramsay score of the Dex+ulinastatin group were significantly different from those of the Dex and ulinastatin groups on the first day after the operation(all P<0.05).CONCLUSION Ulinastatin combined with Dex can prevent the occurrence of POCD and emergence agitation in elderly patients undergoing THA. 展开更多
关键词 ULINASTATIN DEXMEDETOMIDINE Postoperative cognitive dysfunction Inflammatory cytokines total hip arthroplasty
下载PDF
Mortality rate after total knee arthroplasty or total hip arthroplasty in patients with a history of liver transplant
5
作者 E Carlos Rodriguez-Merchan 《World Journal of Orthopedics》 2024年第4期310-311,共2页
In this editorial I comment on the article by Ahmed et al published in a recent issue of the World J Orthop 2023;14:784-790.It is well known that patients who have undergone a liver transplant(LT)may need to have a to... In this editorial I comment on the article by Ahmed et al published in a recent issue of the World J Orthop 2023;14:784-790.It is well known that patients who have undergone a liver transplant(LT)may need to have a total hip arthroplasty(THA)or total knee arthroplasty(TKA)implanted.Ahmed et al stated that the mortality rate in these patients was similar to the one of the general population.However,there are three articles previously published that found higher mortality in LT patients who experienced THA/TKA than in the general population(individuals without LT).Therefore,in this Editorial I would like to point out that there is controversy in the literature regarding whether LT patients undergoing THA/TKA have higher mortality than the general population.Therefore,future research should attempt to resolve this controversy. 展开更多
关键词 Liver transplant total knee arthroplasty total hip arthroplasty RESULTS MORTALITY
下载PDF
Total hip arthroplasty for sequelae of childhood hip disorders:Current review of management to achieve hip centre restoration
6
作者 Anil Thomas Oommen 《World Journal of Orthopedics》 2024年第8期683-695,共13页
Adults requiring total hip arthroplasty(THA)for childhood disorder sequelae present with shortening,limp,pain,and altered gait.THA,which can be particularly challenging due to altered anatomy,requires careful planning... Adults requiring total hip arthroplasty(THA)for childhood disorder sequelae present with shortening,limp,pain,and altered gait.THA,which can be particularly challenging due to altered anatomy,requires careful planning,assessment,and computed tomography evaluation.Preoperative templating is essential to establish the appropriate acetabular and femoral size.Information regarding neck length and offset is needed to ensure the proper options are available at THA.Hip centre restoration must be planned preoperatively and achieved intraoperatively with appropriate exposure,identification,and stable fixation with optimum-size components.Identifying the actual acetabular floor is essential as changes include altered anatomy,distortion of the margins and version changes.Proximal femur changes include anatomical variation,decreased canal diameter,cortical thickness,changes in anteversion,and metaphyseal and diaphyseal mismatch.Preoperative assessment should consist of limb assessment for variations due to prior surgical procedures.Evaluation of the shortening pattern with the relationship of the lesser trochanter to the teardrop would help identify and plan for subtrochanteric shortening osteotomy,especially in high-riding hips.The surgical approach must ensure adequate exposure and soft tissue release to achieve restoration of the anatomical hip centre.The femoral components may require modularity to enable restoration of anteversion and optimum fixation. 展开更多
关键词 total hip arthroplasty Childhood disorder sequelae TEMPLATING hip centre restoration Soft tissue release Offset
下载PDF
Intraoperative application of three-dimensional printed guides in total hip arthroplasty: A systematic review
7
作者 Tim P Crone Bart M W Cornelissen +2 位作者 Jakob Van Oldenrijk Pieter Koen Bos Ewout S Veltman 《World Journal of Orthopedics》 2024年第7期660-667,共8页
BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular compon... BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular components are aligned freehand,without the use of navigation methods.Patient specific instruments(PSI)and three-dimensional(3D)printing of THA placement guides are increasingly used in primary THA to ensure optimal positioning.AIM To summarize the literature on 3D printing in THA and how they improve acetabular component alignment.METHODS PubMed was used to identify and access scientific studies reporting on different 3D printing methods used in THA.Eight studies with 236 hips in 228 patients were included.The studies could be divided into two main categories;3D printed models and 3D printed guides.RESULTS 3D printing in THA helped improve preoperative cup size planning and post-operative Harris hip scores between intervention and control groups(P=0.019,P=0.009).Otherwise,outcome measures were heterogeneous and thus difficult to compare.The overarching consensus between the studies is that the use of 3D guidance tools can assist in improving THA cup positioning and reduce the need for revision THA and the associated costs.CONCLUSION The implementation of 3D printing and PSI for primary THA can significantly improve the positioning accuracy of the acetabular cup component and reduce the number of complications caused by malpositioning. 展开更多
关键词 total hip arthroplasty Three-dimensional printing hip replacement surgery Three-dimensional planning Surgical guides
下载PDF
Technical note for intraoperative determination of proper acetabular cup size in primary total hip arthroplasty
8
作者 Panagiotis Karampinas John Vlamis +5 位作者 Athanasios Galanis Michail Vavourakis Anastasia Krexi Evangelos Sakellariou Christos Patilas Spiros Pneumaticos 《World Journal of Methodology》 2024年第1期94-101,共8页
BACKGROUND Selecting the optimal size of components is crucial when performing a primary total hip arthroplasty.Implanting the accurate size of the acetabular component can occasionally be exacting,chiefly for surgeon... BACKGROUND Selecting the optimal size of components is crucial when performing a primary total hip arthroplasty.Implanting the accurate size of the acetabular component can occasionally be exacting,chiefly for surgeons with little experience,whilst the complications of imprecise acetabular sizing or over-reaming can be potentially devastating.AIM To assist clinicians intraoperatively with a simple and repeatable tip in elucidating the ambivalence when determining the proper acetabular component size is not straightforwardly achieved,specifically when surgeons are inexperienced or preoperative templating is unavailable.METHODS This method was employed in 263 operations in our department from June 2021 to December 2022.All operations were performed by the same team of joint reconstruction surgeons,employing a typical posterior hip approach technique.The types of acetabular shells implanted were:The Dynasty®acetabular cup system(MicroPort Orthopedics,Shanghai,China)and the R3®acetabular system(Smith&Nephew,Watford,United Kingdom),which both feature cementless press-fit design.RESULTS The mean value of all cases was calculated and collated with each other.We distinguished as oversized an implanted acetabular shell when its size was>2 mm larger than the size of the acetabular size indicator reamer(ASIR)or when the implanted shell was larger than 4 mm compared to the preoperative planned cup.The median size of the implanted acetabular shell was 52(48–54)mm,while the median size of the preoperatively planned cup was 50(48–56)mm,and the median size of the ASIR was 52(50–54)mm.The correlation coefficient between ASIR size and implanted acetabular component size exhibited a high positive correlation with r=0.719(P<0.001).Contrariwise,intraoperative ASIR measurements precisely predicted the implanted cups’size or differed by only one size(2 mm)in 245 cases.CONCLUSION In our study,we demonstrated that the size of the first acetabular reamer not entering freely in the acetabular rim corroborates the final acetabular component size to implant.This was also corresponding in the majority of the cases with conventional preoperative templating.It can be featured as a valid tool for avoiding the potentially pernicious complications of acetabular cup over-reaming and over-sizing in primary total hip arthroplasty.It is a simple and reproducible technical note useful for confirming the predicted acetabular cup size preoperatively;thus,its application could be considered routinely,even in cases where preoperative templating is unavailable. 展开更多
关键词 Acetabular shell total hip arthroplasty hip ACETABULUM Acetabular component Primary hip arthroplasty
下载PDF
Primary Total Hip Arthroplasty on Complex Hips Conditions in a Low-Resource Setting
9
作者 Souleymane Ouédraogo Malick Diallo +4 位作者 Sékou Sidibé Massadiami Soulama Adama Sidibé Ousmane Ouermi Patrick W. H. Dakouré 《Open Journal of Orthopedics》 2024年第7期325-333,共9页
Introduction: Total hip arthroplasty of complex morphology is a challenge for the orthopaedic surgeon. Careful analysis of the hip’s anatomy helps to unravel the difficulties and anticipate the procedures to be perfo... Introduction: Total hip arthroplasty of complex morphology is a challenge for the orthopaedic surgeon. Careful analysis of the hip’s anatomy helps to unravel the difficulties and anticipate the procedures to be performed and the implants to be planned. The aim was to identify the types of hip that make first-line THR difficult, specify the technical procedures to be used on these sites, and assess the functional results of the series. Material and Methods: This was a retrospective study that concerned patients operated on for total hip arthroplasty between January 2015 and December 2022 at the medical center “La Grâce” in Bobo-Dioulasso, Burkina Faso. Patients with coxarthrosis (on hip dysplasia, acetabular protrusio, acetabular malunion or neurological hip) and those with ankylosis of the hip, osteonecrosis secondary to neglected dislocation of the hip or hemoglobinopathy were included. Results: A total of 31 total hip replacements were performed in 30 patients. The mean age of patients at the surgery time was 36.2 years with extremes of 17 and 61 years. The male-to-female sex ratio was 1. The main indications for THA were the dysplasic hip osteoarthritis (11 cases) and the neglected hip dislocations (7 cases). In situ femoral neck osteotomy before hip dislocation was performed in seven cases. The acetabulum reconstruction techniques varied from the structural iliac bone graft (n = 3) and cancellous bone graft (n = 4) to the Kerboull plate (n = 1). After 45 months of mean follow-up, all hips were evaluated. The mean PMA score increased from 7.1 [4 - 8] before the surgery to 13.2 [13 - 17]. Conclusion: The large spectrum of challenges in complex hip management requires effective preoperative planning. Preoperative planning minimizes complications and ensures a better outcome. 展开更多
关键词 Primary total hip Arthroplasty hip Dysplasia Complex hip
下载PDF
Physiologic postoperative presepsin kinetics following primary cementless total hip arthroplasty:A prospective observational study
10
作者 Davide Bizzoca Andrea Piazzolla +3 位作者 Lorenzo Moretti Giovanni Vicenti Biagio Moretti Giuseppe Solarino 《World Journal of Orthopedics》 2023年第7期547-553,共7页
BACKGROUND Presepsin is an emerging biomarker in the diagnosis of sepsis.In the field of orthopaedics,it could be useful in diagnosing and managing periprosthetic joint infections.AIM To define the normal postoperativ... BACKGROUND Presepsin is an emerging biomarker in the diagnosis of sepsis.In the field of orthopaedics,it could be useful in diagnosing and managing periprosthetic joint infections.AIM To define the normal postoperative presepsin plasmatic curve,in patients undergoing primary cementless total hip arthroplasty(THA).METHODS Patients undergoing primary cementless THA at our Institute were recruited.Inclusion criteria were:Primary osteoarthritis of the hip;urinary catheter time of permanence<24 h;peripheral venous cannulation time of permanence<24 h;no postoperative homologous blood transfusion administration and hospital stay≤8 d.Exclusion criteria were:The presence of other articular prosthetic replacement or bone fixation devices;chronic inflammatory diseases;chronic kidney diseases;history of recurrent infections or malignant neoplasms;previous surgery in the preceding 12 mo;diabetes mellitus;immunosuppressive drug or corticosteroid assumption.All the patients received the same antibiotic prophylaxis.All the THA were performed by the same surgical and anaesthesia team;total operative time was defined as the time taken from skin incision to completion of skin closure.At enrollment,anthropometric data,smocking status,osteoarthritis stage according to Kellgren and Lawrence,Harris Hip Score,drugs assumption and comorbidities were recorded.All the patients underwent serial blood tests,including complete blood count,presepsin(PS)and C-reactive protein 24 h before arthroplasty and at 24,48,72 and 96 h postoperatively and at 3,6 and 12-mo follow-up.RESULTS A total of 96 patients(51 female;45 male;mean age=65.74±5.58)were recruited.The mean PS values were:137.54 pg/mL at baseline,192.08 pg/mL at 24 h post-op;254.85 pg/mL at 48 h post-op;259 pg/mL at 72 h post-op;248.6 pg/mL at 96-h post-op;140.52 pg/mL at 3-mo follow-up;135.55 pg/mL at 6-mo follow-up and 130.11 pg/mL at 12-mo follow-up.In two patients(2.08%)a soft-tissue infection was observed;in these patients,higher levels(>350 pg/mL)were recorded at 3-mo follow-up.CONCLUSION The dosage of plasmatic PS concentration is highly recommended in patients undergoing THA before surgery to exclude the presence of an unknown infection.The PS plasmatic concentration should be also assessed at 72 h postoperatively,evaluate the maximum postoperative PS value,and at 96 h post-operatively when a decrease of presepsin should be found.The lack of a presepsin decrease at 96 h post-operatively could be a predictive factor of infection. 展开更多
关键词 Presepsin Periprosthetic joint infection total hip arthroplasty total hip replacement hip surgery Postoperative care
下载PDF
Total hip arthroplasty following the failure of intertrochanteric nailing:First implant or salvage surgery? 被引量:3
11
作者 Giuseppe Solarino Davide Bizzoca +4 位作者 Pasquale Dramisino Giovanni Vicenti Lorenzo Moretti Biagio Moretti Andrea Piazzolla 《World Journal of Orthopedics》 2023年第10期763-770,共8页
BACKGROUND Proximal femur fractures,including both intracapsular(femoral neck fractures)and extracapsular fractures(intertrochanteric femoral fractures,IFFs),affect around 1.5 million people per year worldwide.Mechani... BACKGROUND Proximal femur fractures,including both intracapsular(femoral neck fractures)and extracapsular fractures(intertrochanteric femoral fractures,IFFs),affect around 1.5 million people per year worldwide.Mechanical failures of intertrochanteric nailing in IFFs could be managed with revision total hip arthroplasty(THA).AIM To describe the surgical complexity and the procedure-related complication rates in patients with trochanteric nailing failure and treated with THA.METHODS Patients referred to our level I trauma center between April 2012 and July 2018 with failed cephalomedullary nailing following trochanteric fractures were retrospectively recruited.All patients underwent a salvage surgical procedure,i.e.,cephalomedullary nail removal and conversion to THA.The same surgical and anesthesiology team performed the surgical procedures under spinal anesthesia.All patients underwent clinical and radiographic follow-ups for at least 24 mo.Complications and re-operations were recorded.RESULTS Seventy-four patients met the inclusion criteria(male:29;female:45;mean age:73.8-years-old;range:65-89)and were included in the current study.The average operative time was 117 min(76-192 min).The average blood loss was 585 mL(430-1720 mL).Among the 74 patients,43(58.1%)required transfusion of three or more blood units.Two patients died within the 4th d after surgery because of pulmonary embolism,and 1 patient died 9 mo after surgery due to ischemic myocardial infarction.The complication rate in the 71 patients who completed the minimum 24-mo follow-up was 22.5%.In 3 cases out of 71(4.2%)periprosthetic acetabular fracture was observed during the followup.One of these periacetabular fractures occurred intraoperatively.An intraoperative periprosthetic femur fracture was observed in 5 patients out of 71(7.0%).Four of these patients needed a re-operation to fix the fracture with plates and cerclages;in one of these patients,femoral stem revision was also necessary.In 4 patients out of 71(5.6%),an early THA dislocation was observed,whereas in 1 case(1.4%)a late THA dislocation was observed.Three patients out of 71(4.2%)developed a periprosthetic joint infection during the study follow-up.CONCLUSION The present study demonstrated that salvage options for IFF fixation failure are complex procedures with a relevant intraoperative and postoperative complication rate. 展开更多
关键词 Femoral nailing total hip arthroplasty Proximal femur fractures OSTEOPOROSIS Fragility fractures Geriatric patients hip traumatology hip replacement
下载PDF
Comparison of clinical outcomes between total hip replacement and total knee replacement 被引量:1
12
作者 Alexander Green Alex Walsh Oday Al-Dadah 《World Journal of Orthopedics》 2023年第12期853-867,共15页
BACKGROUND Total hip replacements(THR)and total knee replacements(TKR)are effective treatments for severe osteoarthritis(OA).Some studies suggest clinical outcomes following THR are superior to TKR,the reason for whic... BACKGROUND Total hip replacements(THR)and total knee replacements(TKR)are effective treatments for severe osteoarthritis(OA).Some studies suggest clinical outcomes following THR are superior to TKR,the reason for which remains unknown.This study compares clinical outcomes between THR and TKR.AIM To compare the clinic outcomes of THR anad TKR using a comprehensive range of patient reported outcome measures(PROMs).METHODS A prospective longitudinal observational study of patients with OA undergoing THR and TKR were evaluated using a comprehensive range of generic and joint specific PROMs pre-and post-operatively.RESULTS A total of 131 patients were included in the study which comprised the THR group(68 patients)and the TKR group(63 patients).Both groups demonstrated significant post-operative improvements in all PROM scores(P<0.001).There were no significant differences in post-operative PROM scores between the two groups:Hip and Knee Osteoarthritis Outcome scores(P=0.140),Western Ontario and McMaster Universities Osteoarthritis Index pain(P=0.297)stiffness(P=0.309)and function(P=0.945),Oxford Hip and Knee Score(P=0.076),EuroQol-5D index(P=0.386)and Short-Form 12-item survey physical component score(P=0.106).Subgroup analyses showed no significant difference(P>0.05)between cruciate retaining and posterior stabilised prostheses in the TKR group and no significant difference(P>0.05)between cemented and uncemented fixation in the THR group.Obese patients had poorer outcomes following TKR but did not significantly influence the outcome following THR.CONCLUSION Contrary to some literature,THR and TKR are equally efficacious in alleviating the pain and disability of OA when assessed using a comprehensive range of PROMs.The varying knee prosthesis types and hip fixation techniques did not significantly influence clinical outcome.Obesity had a greater influence on the outcome following TKR than that of THR. 展开更多
关键词 OBESITY OSTEOARTHRITIS Patient reported outcome measures total hip arthroplasty total knee arthroplasty
下载PDF
Osteolysis in total hip arthroplasty in relation to metal ion release: Comparison between monolithic prostheses and different modularities 被引量:1
13
作者 Francesco Manfreda Egzon Bufi +4 位作者 Enrico Francesco Florio Paolo Ceccarini Giuseppe Rinonapoli Auro Caraffa Pierluigi Antinolfi 《World Journal of Orthopedics》 2021年第10期768-780,共13页
BACKGROUND Among the various complications associated with total hip arthroplasty(THA)periprosthetic osteolysis and wear phenomena due to the release of metal particles,are two of the most common and have been reporte... BACKGROUND Among the various complications associated with total hip arthroplasty(THA)periprosthetic osteolysis and wear phenomena due to the release of metal particles,are two of the most common and have been reported to be correlated because of inflammatory responses directed towards released particles that generally activate macrophagic osteolytic effects.Therein,new masses known as pseudotumors can appear in soft tissues around a prosthetic implant.To date,there is paucity of reliable data from studies investigating for any association between the above mentioned adverse events.AIM To investigate for the existence of any association between serum and urine concentrations of metal-ions released in THA and periprosthetic osteolysis for modular neck and monolithic implants.METHODS Overall,76 patients were divided into three groups according to the type of hip prosthesis implants:Monoblock,modular with metal head and modular with ceramic head.With an average f-up of 4 years,we conducted a radiological evaluation in order to detect any area of osteolysis around the prosthesis of both the femur and the acetabulum.Moreover,serum and urinary tests were performed to assess the values of Chromium and Cobalt released.Statistical analysis was performed to determine any association between the ion release and osteolysis.RESULTS For the 3 study groups,the monolithic,modular ceramic-headed and modular metal-headed implants had different incidences of osteolysis events,which were higher for the modular implants.Furthermore,the most serious of these(grade 3)were detected almost exclusively for the modular implants with metal heads.A mapping of the affected areas was performed revealing that the highest incidences of osteolysis were evidenced in the pertrochanteric region at the femur level,and in the supero-external region at the acetabular level.Regarding the evaluation of the release of metals-ions from wear processes,serum and urinary chromium and cobalt values were found to be higher in cases of modularity,and even more so for those with metal head.Statistical linear correlation test results suggested positive correlations between increasing metal concentrations and incidences areas of osteolysis.However,no cases of pseudo-tumor were detected.CONCLUSION Future studies are needed to identify risk factors that increase peri-prosthetic metal ion levels and whether these factors might be implicated in the triggering of local events,including osteolysis and aseptic loosening. 展开更多
关键词 total hip arthroplasty Peri-prosthetic osteolysis METAL-IONS Monolithic total hip arthroplasty Modular ceramic headed total hip arthroplasty Modular metallic headed total hip arthroplasty
下载PDF
Protective effect of sevoflurane on lung function of elderly chronic obstructive pulmonary disease patients undergoing total hip arthroplasty
14
作者 Yuan Yao Man-Si Zhang +1 位作者 Yue-Bing Li Ming-Zhe Zhang 《World Journal of Clinical Cases》 SCIE 2023年第31期7619-7628,共10页
BACKGROUND Chronic obstructive pulmonary disease(COPD)is a common respiratory disorder that affects the elderly population and increases the risk of postoperative pulmonary complications(PPCs)after major surgeries.Sev... BACKGROUND Chronic obstructive pulmonary disease(COPD)is a common respiratory disorder that affects the elderly population and increases the risk of postoperative pulmonary complications(PPCs)after major surgeries.Sevoflurane is a volatile anesthetic that has been shown to have anti-inflammatory and antioxidant properties and attenuate lung injury in animal models.AIM To evaluate the protective effect of sevoflurane on the lung function of elderly COPD patients undergoing total hip arthroplasty(THA).METHODS In this randomized controlled trial,we randomly assigned 120 elderly patients with COPD,who were scheduled for THA,to receive either sevoflurane(sevoflurane group)or propofol(propofol group)as the maintenance anesthetic.The primary outcome was the incidence of PPCs within seven days after surgery.The secondary outcomes were changes in the lung function parameters,inflammatory markers,oxidative stress markers,and postoperative pain scores.RESULTS The results showed that the incidence of PPCs was significantly lower in the sevoflurane group than in the propofol group(10%vs 25%,P=0.02).Furthermore,the decline in the forced expiratory volume in 1 s,forced vital capacity,and peak expiratory flow was significantly lesser in the sevoflurane group than in the propofol group at 24 h and 48 h after surgery(P<0.05).The interleukin-6,tumor necrosis factor-alpha,malondialdehyde,and 8-hydroxy-2α-deoxyguanosine levels were significantly lower in the sevoflurane group than in the propofol group at 24 h after surgery(P<0.05).The sevoflurane group showed significantly lower postoperative pain scores than the propofol group at 6 h,12 h,and 24 h after surgery(P<0.05).CONCLUSION Sevoflurane protects the lung function of elderly COPD patients undergoing THA under general anesthesia by reducing the incidence of PPCs,attenuating inflammatory and oxidative stress responses,and alleviating postoperative pain. 展开更多
关键词 SEVOFLURANE PROPOFOL Lung function Chronic obstructive pulmonary disease total hip arthroplasty Elderly patients Inflammatory markers
下载PDF
Clinical outcomes of robotic-assisted and manual total hip arthroplasty in the same patient:A case report
15
作者 Tian-Ye Hu Dao-Chao Lin +2 位作者 Yi-Jun Zhou Zhi-Wu Zhang Jia-Jun Yuan 《World Journal of Clinical Cases》 SCIE 2023年第23期5519-5524,共6页
BACKGROUND Total hip arthroplasty(THA)is an effective treatment for advanced osteonecrosis of the femoral head,which can significantly relieve pain and improve patients'quality of life.Robotic-assisted THA enhance... BACKGROUND Total hip arthroplasty(THA)is an effective treatment for advanced osteonecrosis of the femoral head,which can significantly relieve pain and improve patients'quality of life.Robotic-assisted THA enhances the accuracy and stability of THA surgery and achieves better clinical outcomes than manual THA.CASE SUMMARY We report the clinical outcomes of robotic-assisted THA and manual THA in the same patient with osteonecrosis of the femoral head.A 49-year-old male patient attended our hospital due to more than 3 years of pain in both hip joints.The left hip was treated with robotic-assisted THA.The patient underwent manual THA of the right hip 3 mo after robotic-assisted THA.We obtained postoperative radiograph parameters,Harris hip score and forgotten joint score of the patient 1 year after surgery.CONCLUSION Compared with manual THA,the patient’s left hip felt better 1 year after roboticassisted THA.Robotic-assisted THA resulted in a better Harris hip score and forgotten joint score than manual THA in the same patient with osteonecrosis of the femoral head. 展开更多
关键词 total hip arthroplasty ROBOTIC-ASSISTED Osteonecrosis of the femoral head Case report
下载PDF
Cemented versus uncemented stems for revision total hip replacement:A systematic review and meta-analysis
16
作者 Hany Elbardesy Fitzgerald Anazor +2 位作者 Mohammad Mirza Mohamed Aly Annis Maatough 《World Journal of Orthopedics》 2023年第8期630-640,共11页
BACKGROUND The popularity of uncemented stems in revision total hip arthroplasty(THA)has increased in the last decade.AIM To assess the outcomes of both cemented and uncemented stems after mid-term follow up.METHODS T... BACKGROUND The popularity of uncemented stems in revision total hip arthroplasty(THA)has increased in the last decade.AIM To assess the outcomes of both cemented and uncemented stems after mid-term follow up.METHODS This study was performed following both the Preferred Reporting Items for Systematic Reviews and Meta-analyses Statement and the Cochrane Handbook for systematic reviews and meta-analysis guidelines.Articles were chosen irrespective of country of origin or language utilized for the article full texts.This paper included studies that reviewed revision THA for both cemented or uncemented long stems.RESULTS Three eligible studies were included in the meta-analysis.Analysis was conducted by using Review Manager version 5.3.We computed the risk ratio as a measure of the treatment effect,taking into account heterogeneity.We used random-effect models.There were no significant differences found for intraoperative periprosthetic fractures[risk ratio(RR)=1.25;95%confidence interval(CI):0.29-5.32;P=0.76],aseptic loosening(RR=2.15,95%CI:0.81-5.70;P=0.13),dislocation rate(RR=0.50;95%CI:0.10-2.47;P=0.39),or infection rate(RR=0.99,95%CI:0.82-1.19;P=0.89),between the uncemented and the cemented long stems for revision THA after mid-term follow-up.CONCLUSION This study has evaluated the mid-term outcomes of both cemented and uncemented stems at first-time revision THA.In summary,there were no significant differences in the dislocation rate,aseptic loosening,intraoperative periprosthetic fracture and infection rate between the two cohorts. 展开更多
关键词 Long stem CEMENTED UNCEMENTED Revision total hip arthroplasty META-ANALYSIS
下载PDF
Is There Any Relationship between Total Hip Arthroplasty and Urinary Incontinent?
17
作者 Mariko Asahi Saiji Kondo +2 位作者 Atsushi Kusaba Akihiko Maeda Koji Kanzaki 《International Journal of Clinical Medicine》 CAS 2023年第4期197-205,共9页
Introduction: In my daily practice as a hip surgeon, I have observed some circumstances where urinary incontinence (UI) improves after total hip arthroplasty (THA). We investigated UI symptoms before and after THA at ... Introduction: In my daily practice as a hip surgeon, I have observed some circumstances where urinary incontinence (UI) improves after total hip arthroplasty (THA). We investigated UI symptoms before and after THA at our facility and considered the factors that influence UI. Patients and Method: The subjects were 113 female patients who underwent primary THA in our facility. An anterior lateral approach was used in all cases. Using the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF), we conducted an investigation into the presence of UI before and 2 weeks after THA. An improvement in UI was defined as a decrease of 1 point or more, a worsening is defined as an increase of 1 point or more. Results: The responses from the 113 subjects were analyzed. Of the 113 patients, prior to THA, UI was prevalent among 59 patients and was absent among 54 patients. In the group where UI was prevalent, it improved after THA in 50 patients (85%), remained unchanged in 5 (8%) and worsened in 4 (7%). In the group where UI was absent, 49 patients (91%) remained unchanged and UI appeared in 5 (9%). Compared with the non-prevalence group (62 patients), the prevalence group (50 patients) had a noticeable improvement rate of internal rotation of the surgical hip side (P Conclusion: UI greatly reduces the quality of life (QOL). In this study, there is a possibility that THA improves UI. 展开更多
关键词 total hip Arthroplasty Urinary Incontinence Obturator Internus
下载PDF
Excision of trochanteric bursa during total hip replacement:Does it reduce the incidence of post-operative trochanteric bursitis?
18
作者 Wai-Huang Teng Adeel Ditta +1 位作者 Jane Webber Oliver Pearce 《World Journal of Orthopedics》 2023年第7期533-539,共7页
BACKGROUND Trochanteric bursitis is a common complication following total hip replacement(THR),and it is associated with high level of disability and poor quality of life.Excision of the trochanteric bursa prophylacti... BACKGROUND Trochanteric bursitis is a common complication following total hip replacement(THR),and it is associated with high level of disability and poor quality of life.Excision of the trochanteric bursa prophylactically during THR could reduce the occurrence of post-operative trochanteric bursitis.AIM To evaluate whether synchronous trochanteric bursectomy at the time of THR affects the incidence of post-operative trochanteric bursitis.METHODS This retrospective cohort study was conducted in the secondary care setting at a large district general hospital.Between January 2010 and December 2020,954 patients underwent elective primary THR by two contemporary arthroplasty surgeons,one excising the bursa and the other not(at the time of THR).All patients received the same post-operative rehabilitation and were followed up for 1 year.We reviewed all cases of trochanteric bursitis over this 11-year period to determine the incidence of post-THR bursitis.Two proportion Z-test was used to compare incidences of trochanteric bursitis between groups.RESULTS 554 patients underwent synchronous trochanteric bursectomy at the time of THR whereas 400 patients did not.A total of 5 patients(incidence 0.5%)developed trochanteric bursitis following THR;4 of whom had undergone bursectomy as part of their surgical approach,1 who had not.There was no statistically significant difference between the two groups(Z value 1.00,95%CI:-0.4%to 1.3%,P=0.32).There were also 8 other patients who had both trochanteric bursitis and hip osteoarthritis prior to their THR;all of whom were treated with THR and synchronous trochanteric bursectomy,and 7 had resolution of their lateral buttock pains but 1 did not.CONCLUSION Synchronous trochanteric bursectomy during THR does not materially affect the incidence of post-operative bursitis.However,it is successful at treating patients with known trochanteric bursitis and osteoarthritis requiring THR. 展开更多
关键词 total hip replacement Trochanteric bursectomy Trochanteric bursitis Greater trochanteric pain syndrome
下载PDF
Cementless Buechel-Pappas Resurfacing Total Hip Replacement: A 45-Year Personal Journey to Overcome Wear, Osteolysis, Loosening and Femoral Neck Fractures
19
作者 Frederick F. Buechel Sr 《Open Journal of Orthopedics》 2023年第10期435-442,共8页
Background: Resurfacing-type total hip replacement (THR) has been successfully developed over the past 50 years through collaborative efforts between engineers and surgeons. Much of the development was pursued by indi... Background: Resurfacing-type total hip replacement (THR) has been successfully developed over the past 50 years through collaborative efforts between engineers and surgeons. Much of the development was pursued by individuals or groups, each of which participated in adding further refinements to the implants, instruments and surgical procedures, thus minimizing the serious problems of wear, osteolysis, loosening and femoral neck fractures. The purpose of this study is to explore the development process to optimize the resurfacing total hip replacement into its current application. Methods: In the early 1980s, cementless resurfacing implants were developed using “thin shell” technology to minimize bony resection of the acetabulum and femoral head. Femoral components utilized short, non-porous coated, tapered straight stems to reduce shear stresses in the femoral neck to prevent fractures and stress shielding, while mechanically stabilizing and aligning the components. Acetabular components were anatomically designed to be recessed inside bony borders to avoid neck-cup impingement and loosening. Initially, ultrahigh molecular weight polyethylene (UHMWPE) was used as a bearing, but due to high levels of wear and osteolysis, it was replaced by wear-resistant highly crossed-linked polyethylene (HXLPE) in 2008. Results: Use of HXLPE as a bearing material in both Co-Cr-Mo and titanium nitride (TiN) ceramic-coated resurfacing implants has led to excellent patient outcomes for more than 10 years. In clinical studies, 87% of patients with bilateral total hip replacements prefer their resurfacing-type total hip over their stem-type total hip. The author’s own personal resurfacing total hips, now at 8 and 5 years, respectively, provide “normal” function and no radiographic osteolysis. Conclusions: After 45 years of active evaluation, including mechanical design considerations, prosthetic design development, clinical and radiographic analysis of results, as well as availability of components cleared by the FDA 510 K process, the author has stated a personal preference for the BP Resurfacing Hip System. His excellent mid-term results in both of his resurfaced hips are similar to the long-term results presented in published studies. 展开更多
关键词 Resurfacing total hip Replacement
下载PDF
Total hip replacement using MINIMA^(■)short stem:A short-term follow-up study 被引量:1
20
作者 Georgios I Drosos Stylianos Tottas +3 位作者 Ioannis Kougioumtzis Konstantinos Tilkeridis Christos Chatzipapas Athanasios Ververidis 《World Journal of Orthopedics》 2020年第4期232-242,共11页
BACKGROUND Total hip replacement has become one of the most successful orthopaedic procedures.The length of the femoral stem constitutes one of the most important geometrical and mechanical features of the prosthesis.... BACKGROUND Total hip replacement has become one of the most successful orthopaedic procedures.The length of the femoral stem constitutes one of the most important geometrical and mechanical features of the prosthesis.Several different implants are currently available but data are limited concerning the clinical results for some of these implants.AIM To report the short-term clinical and radiological results of a novel squared section,tapered design–with four conicity-short stem in total hip replacement.METHODS This is a retrospective study of a prospectively collected data using of MINIMA?short stem in 61 consecutive patients with at least 1 year follow-up.The collected data included patients’demographics,type of arthritis,bone morphology,perioperative data,clinical results using Harris Hip Score,EuroQol(EQ-5D),pain score and satisfaction rate,complications and radiological results.RESULTS Total 61 patients were included in our study with a mean age of 56 years of age(range 25-73 years).The majority of them(68.6%)were women,thirty seven patients(56.9%)were less than 60 years of age and almost half of patients(45.1%)suffered from secondary osteoarthritis(hip dysplasia,osteonecrosis,etc.).The mean time of follow-up examination was 33.4 mo(2.8 years)with a range of 12-57 months(1-4.8 years).In 35 patients(56.9%)the follow-up examination was more than 3 years.No major complications such as revision,periprosthetic fracture,dislocation or infection were presented.Re-admission 90 d postoperatively or laterwas deemed unnecessary for any reason regarding the operation.Respectively,the mean pain score,mean Harris hip score,and mean EQ-5D were improved from 6.3,58.7 and 77.3 preoperatively to 0.1,95.1,and 79.8 postoperatively.The Satisfaction rate at the final follow-up was 9.9(SD 0.3,range 8.0-10.0).All stems were classified as stable bone ingrowth and no radiolucent lineswere revealed in any of the modified Gruens’zone at the postoperative Xrays.Stem subsidence was within acceptable limits and the incidence of distal cortical hypertrophy was relatively low.CONCLUSION The clinical and radiological results concerning the MINIMA?short stem are excellent according to this first report of this specific design of the short femoral stems.Because of the small number of cases and short-term follow-up of this study,a longer follow up time and more patients’enrollment is required. 展开更多
关键词 total hip replacement total hip arthroplasty Short-stem hip prostheses Femoral components MINIMA^(■) stem
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部