期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Groundwater Potential Mapping in Lapan Gwari Community Using Integrated Remote Sensing and Electrical Resistivity Soundings
1
作者 Ayuba Danmangu Mangs Jude Steven Ejepu +5 位作者 Charity Chizaram Nkemkah Solomon Nehemiah Yusuf Adamu Keana Sallau Janet Agati Yakubu Yusuf Ibrahim Williams Midala Wakili 《International Journal of Geosciences》 2023年第8期719-732,共14页
This research aims to address the pressing issue of failed and abandoned wells, causing water scarcity in Lapan Gwari Community, through an improved groundwater exploration approach integrating remote sensing and elec... This research aims to address the pressing issue of failed and abandoned wells, causing water scarcity in Lapan Gwari Community, through an improved groundwater exploration approach integrating remote sensing and electrical resistivity soundings. The study area, located within the Zungeru Sheet 163 SE, spans Latitudes 9°30'00"N to 9°32'00"N and Longitudes 6°28'00" to 6°30'00". The surface geologic, structural, and hydrogeological mapping provided essential insights into the hydrogeological framework. Leveraging SRTM DEM data, thematic maps were created for geomorphology, slope, land use, lineament density, and drainage density. These datasets were then integrated using ArcGIS to develop a preliminary groundwater potential zones map. Further investigations were conducted using Vertical Electrical Sounding (VES) and Electrical Resistivity Imaging (2D VES) surveys at targeted locations identified by the preliminary map. Results show that the study area predominantly consists of crystalline rocks of the Nigerian Basement Complex, primarily comprising schist and granite with minor occurrences of quartz vein intrusions. Surface joint directions indicated a dominant NE-SW trend. The VES data revealed three to four geoelectric layers, encompassing the topsoil (1 to 5 m depth, resistivity: 100 Ωm to 300 Ωm), the weathered layer (in the 3-layer system) or fractured layer (in the 4-layer system), and the fresh basement rock characterized by infinite resistivity. The shallow weathered layers (3 to 30 m thickness) are believed to hold aquiferous potential. Hydrogeological interpretation, facilitated by 2D resistivity models, delineated water horizons trapped within clayey sand and weathered/fractured formations. Notably, the aquifer resistivity range was found to be between 3 - 35 m and 100 - 300 Ωm, signifying a promising aquifer positioned at depths of 40 to 88 m. This aligns with corroborative static water level measurements. Given this, we recommend drilling depths of a minimum of 80 m to ensure the acquisition of sufficient and sustainable water supplies. The final groundwater potential zones map derived from this study is expected to serve as an invaluable guide for prospective groundwater developers and relevant authorities in formulating effective water resource management plans. By effectively tackling water scarcity challenges in Lapan Gwari Community, this integrated approach demonstrates its potential for application in similar regions facing comparable hydrogeological concerns. 展开更多
关键词 vertical electrical sounding electrical Resistivity Imaging Fractured Aquifer Groundwater Exploration
下载PDF
Characterization of Subsurface Lithology and Aquifer Parameters Using Vertical Electrical Sounding(VES)for Groundwater Development in Igbo-Imabana,Southern Nigeria
2
作者 Philip Obasi Awara Ekinya +1 位作者 Chibuike Akpa Emmanuel Edene 《Advances in Geological and Geotechnical Engineering Research》 2022年第3期12-31,共20页
Vertical Electrical Soundings(VES)using Schlumberger array was carried out at fifteen(15)different points to evaluate aquifer characteristics within Igbo-Imabana,Abi L.G.A of Cross River State.Resistivity meter and it... Vertical Electrical Soundings(VES)using Schlumberger array was carried out at fifteen(15)different points to evaluate aquifer characteristics within Igbo-Imabana,Abi L.G.A of Cross River State.Resistivity meter and its accessories were used for data acquisition.The maximum current and potential electrode distance were 400 m and 20 m respectively.The field data were interpreted using Interpex software and three to five geo-electric layers encountered within the study area.The dominant curve type was H followed by K.From the result,geo-electric layers delineated were sandstone,clay,saturated sandstone,sandy shale,clayey shale,and shale with average apparent resistivity values of 2249.94Ωm,2.86Ωm,365.28Ωm,222.69Ωm,14.60Ωm and 59.02Ωm respectively.The top geoelectric layer was dominantly lateritic topsoil,with variation in degrees of compaction and having an average resistivity of 876.33Ωm with depth and thickness generally less than 5 m.The calculated aquifer parameters hydraulic conductivity(K_(c)),transmissivity,longitudinal conductance,and transverse resistance from the VES results show ranges values;3.86×10^(-4)to 4.69×10^(-2)m/day,2.95×10^(-3)to 2.82 m^(2)/day,2.95×10^(-3)to 2.81Ωm and 484.33 to 19444.83Ω^(2)m respectively.The aquifer thickness and depth values range from 3.60 m to 68.05 m and 5.20 m to 76 m respectively.The study reviewed that the area is made of heterolithic/heterogenous lithofacies,confined aquifer(s),shallow and deep aquifer.Also,from the models and aquifer parameters,the area is characterized by semipervious materials.This integrally explains why the area have have low transmissivity and majority of boreholes drilled in the area failed. 展开更多
关键词 GROUNDWATER Aquifer parameters vertical electrical sounding(VES) Igbo-Imabana
下载PDF
Electrical Resistivity Sounding for Groundwater Investigation around Enugu Metropolis and the Environs, Southeast Nigeria
3
作者 Claris C. Nwachukwu Charles C. Ugbor Osim Jethro Ogboke 《International Journal of Geosciences》 2022年第1期54-70,共17页
This report evaluates the use of electrical method and borehole data to investigate the subsurface to delineate the groundwater potential in Enugu metropolis and the environs, south-eastern Nigeria other than rely onl... This report evaluates the use of electrical method and borehole data to investigate the subsurface to delineate the groundwater potential in Enugu metropolis and the environs, south-eastern Nigeria other than rely only on resistivity method w</span><span style="font-family:Verdana;">hich could lead to interpretation error. Integrating these 2 data sets is key in this study. The study area is located in the Anambra Basin and is underlain by Nkporo/Enugu Shale which is overlain by the Mamu Formation. It is bounded by Latitudes 6</span><span style="font-family:Verdana;"><span style="white-space:nowrap;">&#176;</span>2 0'00</span></span><span style="font-family:Verdana;">"</span><span style="font-family:Verdana;">N to 6<span style="white-space:nowrap;">&#176;</span>30'00</span><span style="font-family:Verdana;">"</span><span style="font-family:Verdana;">N and Longitudes 7<span style="white-space:nowrap;">&#176;</span>25'00</span><span style="font-family:Verdana;">"</span><span style="font-family:Verdana;">E to 7<span style="white-space:nowrap;">&#176;</span>35'00</span><span style="font-family:Verdana;">"</span><span style="font-family:""><span style="font-family:Verdana;">E and covers surface area of about 342 m</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;">. Thirty</span></span><span style="font-family:Verdana;">-</span><span style="font-family:Verdana;">one vertical electrical soundings (VES) were carried out across the area using the Schlumberger electrode array with current electrode separation from 2 to 500 m to identify the depths and resistivity values of the identified geo-electric layers. Through data analysis using WinResist software, the apparent resistivity, thicknesses and depths and the thicknesses of the aquifers were generated. The resistivity</span><span style="font-family:""> </span><span style="font-family:Verdana;">and depths were modelled to generate resistivity map and depth map. The resistivity of the aquiferous zone within the study area varie</span><span style="font-family:Verdana;">d</span><span style="font-family:Verdana;"> from 20.55</span><span style="font-family:""> - </span><span style="font-family:Verdana;">427.8 ohm-m at depths of between 10.7</span> - <span style="font-family:Verdana;">40.05 m. Depth to the water table appears to be shallow at the south western part of the map. The interpreted geo-electric layers show a sequence of lateritic top soil, shale, sand and shale. The frequency distribution of the VES curves generated shows the presence of 3 to 5 layers with HK type as the highest. Also, a 2D model was generated using the correlation of VES to VES data and borehole data to VES data to show the underlying stratigraphy beneath the study area as well as the direction of ground water flow. Result of the VES curve analysis reveal</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;"> that the sub-surface is underlain by three lithological layers namely: lateritic top soil, shale, sand and shales with NW direction of groundwater flow from the 2D model. Groundwater prospective zones can be seen along NW, SW and central parts of the study area which have low resistivity values. 展开更多
关键词 electrical Method vertical electrical sounding GROUNDWATER AQUIFER Apparent Resistivity
下载PDF
Electrical geophysical evaluation of susceptibility to flooding in University of Nigeria, Nsukka main campus and its environs, Southeastern Nigeria
4
作者 Daniel Nnaemeka Obiora Johnson Cletus Ibuot 《Journal of Groundwater Science and Engineering》 2023年第4期422-434,共13页
Flooding occurs when rainfall exceeds the absorption capacity of soil and causes significant environmental consequences.In this study,electrical resistivity techniques were employed to assess the flood susceptibility ... Flooding occurs when rainfall exceeds the absorption capacity of soil and causes significant environmental consequences.In this study,electrical resistivity techniques were employed to assess the flood susceptibility of the study area by examining variations in electrical properties.Prior to flooding,Vertical Electrical Sounding(VES)and Electrical Resistivity Tomography(ERT)profiles were conducted to determine the variations in resistivity within subsurface lithologies exposed to the injected current.The injected current penetrated the subsurface units characterised by resistivity ranging from 190.5Ω·m to 6,775.7Ω·m,42.3Ω·m to 7,297.4Ω·m,and 320.2Ω·m to 24,433.3Ω·m in the first,second and third layers,respectively.These layers were identified as lateritic topsoil,medium-coarse brownish grained sand,and coarse pebbly blackish sand,respectively.The calculated reflection coefficients between layers 1,2,and 3 reveal alternation in layers with values ranging from−0.04 to 0.66 and 0.36 to 0.95 for and,respectively.The transverse resistivity,longitudinal resistivity and anisotropy ranged from 243.59Ω·m to 24,115.42Ω·m,199.61Ω·m to 14,950.76Ω·m,and 1.02 to 2.14.Models derived from the ERT profiles reveal variations in resistivity,pinpointing areas of low resistivity which correspond to waterlogged and impermeable layers.The result of this study underscores the importance of integrated resistivity techniques in the study of floods,as it provides valuable insights into flood behaviour,and subsurface dynamics. 展开更多
关键词 Anisotropy vertical electrical sounding electrical resistivity tomography Geoelectric layer Permeability
下载PDF
Hydrogeophysical and Structural Investigations Using VES: A Case Study of Dosso Region in the Southwestern Part of the Meso-Cenozoic Iullemmeden Basin (Southwestern Niger)
5
作者 Abdou Ali Ibrahim Huguette C. Emvoutou +2 位作者 Alain Zanga Konaté Moussa Serigne Faye 《Open Journal of Geology》 CAS 2024年第1期50-80,共31页
A regional study connecting geolelectrical surveys with geology and hydrogeology was carried out in the western part of the Iullemmeden basin, precisely in the Dosso region in Niger. One hundred and four (104) vertica... A regional study connecting geolelectrical surveys with geology and hydrogeology was carried out in the western part of the Iullemmeden basin, precisely in the Dosso region in Niger. One hundred and four (104) vertical electrical sounds have been realized, among them nineteen representative were thus be used as parametric surveys. The local resistivity values of the geological formations of Quaternary range from 100 Ω⋅m to 1000 Ω⋅m (sands and lateritic sandstones). The Oligo-Miocene formation of the Continental terminal (Ct) shows resistivity values ranging from 1 to 5 Ω⋅m (brackish groundwaters) to 1500 Ω⋅m (clay sandstones) while the Upper Cretaceous formation of the Continental “hamadien” (Ch) indicates values ranging from 20 Ω⋅m (sandy clay) to 5000 Ω⋅m (clayey sandstones). The geological formations of Paleocene have values from 2 Ω⋅m (marls) to 60 Ω⋅m (calcareous marl), while the Precambrian basement exhibits values of granite around 300 Ω⋅m to 60,000 Ω⋅m. The update of the structural settings reveals many faults in the study area which explain both the shape of the basin and the geometry of the aquifers. Tectonics is also consistent with the hydraulic characteristics of aquifers. In addition, brackish groundwaters were identified as perched aquifer groundwaters in different depths in Dosso region. They probably come from the marine brines during the regression of the Paleocene Sea. 展开更多
关键词 vertical electrical soundings Continental Terminal Continental “Hamadien” Brackish Groundwaters Iullemmeden Basin Dosso Region
下载PDF
Estimating aquifer transmissivity using Dar-Zarrouk parameters to delineate groundwater potential zones in Alluri Seetharama Raju District,Andhra Pradesh, India 被引量:1
6
作者 Bakuru Anandagajapathi Raju Palavai Venkateswara Rao Mangalampalli Subrahmanyam 《Journal of Groundwater Science and Engineering》 2023年第2期116-132,共17页
This study aimed to explore groundwater potential zones in the EGMB of Alluri Seetharama Raju district, Andhra Pradesh, India, for drinking and agriculture purposes. To achieve this goal, 72 Vertical Electrical Soundi... This study aimed to explore groundwater potential zones in the EGMB of Alluri Seetharama Raju district, Andhra Pradesh, India, for drinking and agriculture purposes. To achieve this goal, 72 Vertical Electrical Soundings(VES) were conducted using the Schlumberger electrode configuration. The resistivity sounding data were analyzed to determine the aquifer thickness, basement depth, Dar-Zarrouk parameters,and aquifer transmissivity. Spatial distribution maps were generated for these parameters to understand the subsurface formation. The analysis revealed a linear groundwater potential zone(8.46 km~2) in the eastern part of the study area, extending in the NNE-SSW direction for 9.6 km. Six VES locations(P24, P27, P29,P30, P33, and P38) in this zone exhibit good potential(>30 m aquifer thickness), while the three VES locations(OP19, P5, and P46) in the central region are recommended for drilling bore wells. Additionally,moderate aquifer thickness(20–30 m) are identified in other VES locations(OP14, OP20, P4, P10, P12,P13, P15, P17, P18, P31, P46, and P50) along streams in the western and central part of the area, which can yield reasonable quantities of water. This information is useful for groundwater exploration and watershed management to meet the demands of tribal population in the study area. 展开更多
关键词 vertical electrical sounding Longitudinal conductance Transverse resistance Coefficient of anisotropy Potential groundwater locations
下载PDF
Dar Zarrouk Parameter as a Tool for Evaluation of Well Locations in Afikpo and Ohaozara, Southeastern Nigeria 被引量:1
7
作者 Robert Egwu Otu Iduma Tamunoene Kingdom Simeon Abam Etim Daniel Uko 《Journal of Water Resource and Protection》 2016年第4期505-521,共17页
The inhabitants of this area depend solely on contact springs as supply source of potable water. However, provision of potable water to meet the needs of the people still remains an unsolved problem. Therefore, this p... The inhabitants of this area depend solely on contact springs as supply source of potable water. However, provision of potable water to meet the needs of the people still remains an unsolved problem. Therefore, this paper attempts to solve this problem by using Dar Zarrouk (D-Z) Parameters;Total Transverse Unit Resistance, T (Ωm<sup>2</sup>) and Total Longitudinal Unit Conductance, S (Ω<sup>-1</sup>) to suggest optimal locations for drilling of boreholes in the study area. To attain this purpose, 50 Schlumberger Vertical Electrical Sounding (VES) curves with maximum current electrode spacing of AB/2 = 681 m were interpreted. Thus, the aquifer parameters information estimated from the (VES) curves were used to prepare contour maps of T (Ωm<sup>2</sup>), S (Ω<sup>-1</sup>), aquifer thickness h (m), aquifer resistivity ρ (Ωm), and Water Table Depth (WTD). For effective use of these parameters, iso-thickness and iso-resistivity maps were compared with contour map of transverse resistance. The good agreement between these parameters provided the basis for identification of prolific aquiferous zones. It was observed that the Southern part of the study area majorly underlain by the Afikpo Sandstone of Nkporo Formation (Campanian-Maastrichtian), relatively showed higher T (Ωm<sup>2</sup>), h (m), and ρ (Ωm) values, which implies high yield aquiferous zones. The relatively loose structure of this sandstone unit, coarse grains, and sorting enables it to be porous and permeable. The Northern part of the region which shows low values for T (Ωm<sup>2</sup>), h (m), and ρ (Ωm) suggests low productivity for the aquiferous zones. The paucity of water in this parts of the study area can be explained to be as a result of the dominant geology. The high S, values at the Uburu and Okposi locations in this region suggests the presence of saline aquifer. This study would be relevant to the development of effective ground water scheme and for future hydrogeological investigations in the area. 展开更多
关键词 vertical electrical sounding Dar Zarrouk Parameters Nkporo Formation Afikpo Sandstone
下载PDF
Evaluation of Aquifer Characteristics and Groundwater Protective Capacity in Abavo, Nigeria
8
作者 Felix Iwebunor Chinyem Glory Ovwamuedo 《International Journal of Geosciences》 CAS 2024年第11期841-860,共20页
Aquifer characteristics evaluation enables the determination of aquifer’s ability to recharge as well as discharge. However, knowledge of aquifer characteristics has been scarce in Abavo area. Thus, geophysical and h... Aquifer characteristics evaluation enables the determination of aquifer’s ability to recharge as well as discharge. However, knowledge of aquifer characteristics has been scarce in Abavo area. Thus, geophysical and hydrogeological investigations, involving vertical electrical sounding (VES), pumping test and well logging were conducted in Abavo area, Nigeria, to evaluate the aquifer hydraulic properties as well as the groundwater protective capacity of the area. Seventeen (17) VES, using the Schlumberger configuration, were carried out. The field data were curve-matched, iterated, using Win Resist software. The VES result revealed subsurface lithology that comprised lateritic top soil/sand, sandy clay/clayey sand, fine sand, medium sand and coarse to gravelly sand. The VES result equally revealed an aquifer depth range from 28.8 - 76.6 m, with resistivity range from 1175 - 27,272 Ω·m. Two boreholes were drilled, the cuttings were collected and were used to model the subsurface lithology. Well logging result showed that the electrical conductivity (EC) as well as total dissolved solid (TDS) are 15 μs/cm and 112 mg/l respectively, indicative of the fact that the values were within the standard organization of Nigeria (SON) permissible limit for drinking water. Pumping test analysis, using the Cooper Jacob’s method, revealed that the transmissivity, specific capacity, storativity and hydraulic conductivity are 5.9 m2/day, 33.13 m/day, 0.0069 and 0.1722 m/day respectively. The study revealed longitudinal conductance and transverse resistance range of 0.001048 - 0.027828 Ω−1 and 105470.4 - 1255775.3 Ω·m2 respectively. These results have established that the aquifer is semi-confined, has poor protective capacity and high rechargibility and will provide adequate, potable groundwater for local water supply to communities for domestic and other purposes. 展开更多
关键词 Groundwater Transmissivity Abavo Pumping Test vertical electrical sounding
下载PDF
Geoelectrical Investigation of Groundwater Potentials of Northern Paiko,Niger State,North Central Nigeria
9
作者 Usman D.Alhassan Daniel Nnaemeka Obiora Francisca Nneka Okeke 《Journal of Earth Science》 SCIE CAS CSCD 2017年第1期103-112,共10页
Vertical electrical sounding(VES) was carried out in northern part of Paiko, North Central Nigeria, using Abem terrameter model SAS 4000 to determine the subsurface layer parameters(resistivities, depths and thickn... Vertical electrical sounding(VES) was carried out in northern part of Paiko, North Central Nigeria, using Abem terrameter model SAS 4000 to determine the subsurface layer parameters(resistivities, depths and thickness) employed in delineating the groundwater potential of the area. A total of six transverses with ten VES stations along each traverse, at intervals of 50 m were investigated. It has a maximum current electrode separation(AB/2) of 100 m. Three to four distinct geoelectric layers were observed, namely, the top layer, the weathered layer, the fractured/fresh layer, and the fresh basement layer. The observed frequencies in curve types include 21% of H, 4.2% of HA, 2.4% of K, 4.2% of A, 1.67% of KH and 3% of HK. Eight VES stations were delineated as ground water potentials of the area, with third and fourth layer resistivities ranging from 191 to 398 ?·m. Depths range from 13.60 to 36.60 m and thickness varies from 9.23 to 30.51 m. A correlation of the borehole log with the VES lithology is in agreement. Viable boreholes for good portable water should be sited at VES stations J8 and J10 having a fine aquifer at a depth of 36.60 and 17.80 m respectively with thickness of 30.51 and 15.07 m, respectively. 展开更多
关键词 vertical electrical sounding groundwater potential northern Paiko RESISTIVITY aquifer geoelectric layer Abem terrameter.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部