期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
A NEW TYPE LOW SHEAR RATE VISCOMETER FOR HIGH MOLECULAR WEIGHT POLYMER
1
作者 叶美玲 韩冬 施良和 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1996年第4期311-317,共7页
In this paper, the effects of shear rate on the intrinsic viscosity measurement of partially Hydrolysed Polyacrylamide (HPAM) in salt solution were studied with homemade multibulb viscometer and low shear rate rheomet... In this paper, the effects of shear rate on the intrinsic viscosity measurement of partially Hydrolysed Polyacrylamide (HPAM) in salt solution were studied with homemade multibulb viscometer and low shear rate rheometer. The critical shear rate of HPAM in salt solution for high molecular weight HPAM was determined. A low shear rate capillary viscometer was designed in which the [eta] approached to value at zero shear rate can be obtained for HPAM -salt system. The effect of molecular weight on shear rate dependence of viscosity was also studied. 展开更多
关键词 viscometer intrinsic viscosity molecular weight POLYELECTROLYTE POLYACRYLAMIDE capillary viscometer
下载PDF
Effect of Thermal Convection on Viscosity Measurement in Vibrational Viscometer
2
作者 Ali Akpek Chongho Youn +2 位作者 Atsushi Maeda Nobuyuki Fujisawa Toshiharu Kagawa 《Journal of Flow Control, Measurement & Visualization》 2014年第1期12-17,共6页
This paper describes the experimental study of viscosity measurement error in the vibrational type viscometer, which measures viscous damping of the oscillating circular plate in a fluid in continuously increasing tem... This paper describes the experimental study of viscosity measurement error in the vibrational type viscometer, which measures viscous damping of the oscillating circular plate in a fluid in continuously increasing temperatures. The experiments are carried out to measure non-uniformity of the temperature field in the test cup of the vibrational viscometer in continuously increasing temperatures, while changing the viscosity of the target fluids. Experimental outcomes show that non-uniformity of the temperature grows in the cup and results in viscosity measurement error, when the viscosity of the fluid increases. In order to understand this phenomenon, velocity measurement by particle image velocimetry is conducted in the test cup for fluids of varying viscosity. The results indicate that mixing is enhanced in the low-viscosity fluid by the occurrence of unsteady thermal convection, while weaker convection appears in the high-viscosity fluid. 展开更多
关键词 VISCOSITY Measurement VIBRATIONAL viscometer Thermal CONVECTION RAYLEIGH Number PIV
下载PDF
Ultra-High Sensitivity Viscometer Based on a Torsion Pendulum
3
作者 Xiao-Guang Ma Lan Chen +2 位作者 Hai-Yan Wang Jin-Xiu Zhang Xiao-Min Xiong 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第6期6-10,共5页
Based on a conventional torsion pendulum,we develop a forced oscillation viscometer with ultra-high viscosity sensitivity of 2×10^(-7)Pa·s working at frequencies near the resonance.The viscosity is achieve... Based on a conventional torsion pendulum,we develop a forced oscillation viscometer with ultra-high viscosity sensitivity of 2×10^(-7)Pa·s working at frequencies near the resonance.The viscosity is achieved by exploiting the phase lag for the angle displacement behind the torque,instead of the resonant curve,i.e.,the variation of angle displacement amplitude versus frequency.The general formula for the measurement of the visco-elasticit.y of complex fluids is also presented.With such precision it is easy to measure tiny change in viscosity result from circumstantial influences.Deionized water and two kinds of NaCl aqueous solutions are chosen to demonstrate the performance of our home-made torsion pendulum-based viscometer. 展开更多
关键词 Ultra-High Sensitivity viscometer Based on a Torsion Pendulum
原文传递
Viscosity testing method of ultra-low temperature drilling fluids for polar glacier drilling 被引量:4
4
作者 HAN Lili XU Huiwen +2 位作者 CAO Pinlu YU Dahui P.G.Talalay 《Global Geology》 2012年第4期276-280,共5页
According to the working environment of the polar glacier core drilling, a separatory funnel capillary viscometer which can be used for testing the viscosity of liquids under ultra-low temperature conditions was de- s... According to the working environment of the polar glacier core drilling, a separatory funnel capillary viscometer which can be used for testing the viscosity of liquids under ultra-low temperature conditions was de- signed. This viscometer has a simple structure and it is easy to operate, which can meet the testing requirements of different temperature conditions. The viscosity of the dimethyl silicone oil KF-96L-2.0cs was measured under different temperatures using this designed viseometer, and it is found that the viscometer coefficient K changes linearly with temperature. This testing method has relatively high test accuracy and its relative error is less than 4%, which can be used to test the viscosity of the different liquids in ultra-low temperature conditions. 展开更多
关键词 polar drilling separatory funnel-capillary viscometer VISCOSITY dimethyl silicone oil viscometer coefficient
下载PDF
THE APPARENT VISCOSITY OF SEMI-SOLID AZ91D ALLOY AT STEADY STATE 被引量:10
5
作者 Z.S. Zhen, W.M. Mao, S.J. Van, A.M. Zhao, C.L. Cui and X.Y. ZhongSchool of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2002年第6期505-510,共6页
The rheological behavior of semi-solid AZ91D at steady state is studied usinga Couette type viscometer in the present paper. The results show that the apparent viscosity ofsemi-solid AZ91D at the steady state increase... The rheological behavior of semi-solid AZ91D at steady state is studied usinga Couette type viscometer in the present paper. The results show that the apparent viscosity ofsemi-solid AZ91D at the steady state increases with the solid fraction increasing, and goes upsharply when the solid fraction reaches a certain value, which is called critical fraction. Inaddition, the apparent viscosity of semi-solid AZ91D at the steady state takes on a distinctdowntrend with the shearing rate increasing, which indicates a strong shear thinning property. Inaddition, the critical solid fraction becomes higher under larger shearing rate, owing to the moreglobular shape of the solid particles. Based on the present experiment results, an empiricalequation is built as that, relating the steady state apparent viscosity of semi-solid AZ91D with thesolid fraction f_s and shearing rate gamma at the same time: eta_(app)=10.74 exp (6.95 f_s)gamma^(-0.86). 展开更多
关键词 rheological behavior magnesium alloy SEMI-SOLID VISCOSITY viscometer
下载PDF
A new and reliable model for predicting methane viscosity at high pressures and high temperatures 被引量:6
6
作者 Ehsan Heidaryan Jamshid Moghadasi Amir Salarabadi 《Journal of Natural Gas Chemistry》 EI CAS CSCD 2010年第5期552-556,共5页
In recent years, there has been an increase of interest in the flow of gases at relatively high pressures and high temperatures. Hydrodynamic calculation of the energy losses in the flow of gases in conduits, as well ... In recent years, there has been an increase of interest in the flow of gases at relatively high pressures and high temperatures. Hydrodynamic calculation of the energy losses in the flow of gases in conduits, as well as through the porous media constituting natural petroleum reservoirs, requires knowledge of the viscosity of the fluid at the pressure and temperature involved. Although there are numerous publications concerning the viscosity of methane at atmospheric pressure, there appears to be little information available relating to the effect of pressure and temperature upon the viscosity. A survey of the literature reveals that the disagreements between published data on the viscosity of methane are common and that most investigations have been conducted over restricted temperature and pressure ranges. Experimental viscosity data for methane are presented for temperatures from 320 to 400 K and pressures from 3000 to 140000 kPa by using falling body viscometer. A summary is given to evaluate the available data for methane, and a comparison is presented for that data common to the experimental range reported in this paper. A new and reliable correlation for methane gas viscosity is presented. Predicted values are given for temperatures up to 400 K and pressures up to 140000 kPa with Average Absolute Percent Relative Error (EABS) of 0.794. 展开更多
关键词 METHANE VISCOSITY falling body viscometer high pressures high temperatures CORRELATION
下载PDF
Experimental Investigation on Viscosity of Cu-H_2O Nanofluids 被引量:2
7
作者 李新芳 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2009年第1期48-52,共5页
A procedure for preparing a nanofluid that a solid-liquid composite material consists of solid nanoparticles with sizes typically of 1-100 nm suspended in liquid was proposed. By means of the procedure, Cu-H2O nanoflu... A procedure for preparing a nanofluid that a solid-liquid composite material consists of solid nanoparticles with sizes typically of 1-100 nm suspended in liquid was proposed. By means of the procedure, Cu-H2O nanofluids with and without dispersant were prepared, whose sediment pho-tographs and particle size distribution were given to illustrate the stability and evenness of suspension with dispersant. The viscosity of Cu-H2O nanofluid was measured using capillary viscometers. The mass fractions(w) of copper nanoparticles in the experiment varied between 0.04% and 0.16% with the temperature range of 30-70 ℃. The experimental results show that the temperature and SDBS concentration are the major factors affecting the viscosity of the nano-copper suspensions, while the effect of the mass fraction of Cu on the viscosity is not as obvious as that of the temperature and SDBS dispersant for the mass fraction chosen in the experiment. The apparent viscosity of the copper nano-suspensions decreases with the temperature increase, and increases slightly with the increase of the mass fraction of SDBS dispersant, and almost keeps invariability with increasing the mass fraction of Cu. The influence of SDBS concentration on the viscosity of nano-suspension was relatively large comparing with that of the nanoparticle concentration. 展开更多
关键词 nano-Cu/water suspension SDBS kinematic viscosity capillary viscometer
原文传递
Densities and Viscosities of 1-butyl-3-methylimidazolium Hexafluorophosphate [bmim][PF6] + CO2 Binary System: Determination and Correlation 被引量:1
8
作者 乔燕 闫方友 +1 位作者 夏淑倩 马沛生 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2013年第11期1284-1290,共7页
A gas-dissolving device was designed and connected to the falling-body viscometer, which was used to determine the viscosities of liquids in our lab before. The equipment can be used to determine the gas composition, ... A gas-dissolving device was designed and connected to the falling-body viscometer, which was used to determine the viscosities of liquids in our lab before. The equipment can be used to determine the gas composition, the densities and viscosities of the solution at the same time. The densities and viscosities of [bmim][PF6] + CO2 binary system were determined in the temperature range of 313.2 to 413.2 K and pressure range of 5.0 to 25.0 MPa by the equipment. Then the viscosities of [bmim][PF6] + CO2 binary system at constant temperature, constant pressure, and different temperature and pressure were correlated, respectively. For the correlation at different tempera- ture and different t3ressure for different concentration mixtures the average relative deviation ARD is 0.037. 展开更多
关键词 viscosity falling-body viscometer [bmim] [PF6] ionic liquid carbon dioxide
下载PDF
Dependence of viscosity of Cu_9In_4 intermetallics melt on thermal history 被引量:1
9
作者 CHENG Sujuan WANG Zhonghua +1 位作者 BIAN Xiufang SUI Xuepu 《Rare Metals》 SCIE EI CAS CSCD 2006年第1期27-31,共5页
The temperature dependence of the dynamic viscosity of Cu9In4 intermetallics melt has been investigated in five kinds of different heating and cooling processes with a torsional oscillation viscometer, It has been fou... The temperature dependence of the dynamic viscosity of Cu9In4 intermetallics melt has been investigated in five kinds of different heating and cooling processes with a torsional oscillation viscometer, It has been found that the viscosity of all Cu9In4 intermetallics decreases with increasing temperature in five kinds of different thermal processes. Thermal history has considerable effect on the viscosity. The viscosity in the cooling process with high superheating is greater than that in the cooling process with low superheating. The viscosity in the heating process is greater than that in the cooling process. No anomalous change in viscosity is measured in three kinds of cooling processes with low superheating. The anomalous change occurs at about 1050℃ in cooling with high superheating and at 800℃ in heating. Furthermore, the structural variation in different thermal processes has also been discussed on the basis of the change in viscosity and DSC analysis. 展开更多
关键词 liquid structure VISCOSITY torsional oscillation viscometer Cu9In4 intermetallics thermal history
下载PDF
润滑油低温表观粘度测定及影响因素 被引量:2
10
作者 钮晓予 《广东化工》 CAS 2017年第8期44-45,共2页
在低温下测定润滑油布式粘度的影响因素。分析差异的原因并对实验现象做出了解释。
关键词 低温表观粘度 Brookfield viscometer 润滑油
下载PDF
A Modified Methodology to Evaluate Viscosity of Non-Newtonian Liquid Foods with a Flow Channel Instrument
11
作者 Masanori Yoshida Akimasa Soda +2 位作者 Aya Togashi Yuta Egawa Yuki Sato 《Journal of Food Science and Engineering》 2013年第8期411-423,共13页
Through experimental analysis of the liquid flows in a flow channel instrument, prompt evaluation of the physically defined viscosity of non-Newtonian liquid foods was investigated for development into a structurally ... Through experimental analysis of the liquid flows in a flow channel instrument, prompt evaluation of the physically defined viscosity of non-Newtonian liquid foods was investigated for development into a structurally simple and easy-to-use viscometer. For Newtonian and non-Newtonian test liquids, a relation between the friction coefficient and Reynolds number, which was dimensionless as derived from an expression of analysis as a gravity current, indicated a condition under which the flow in the instrument was laminar and under which an average shear rate was on the order of less than 1 s~. Prediction organized based on this empirical relation reproduced practically the flow curve determined for the liquid foods using a rotor type viscometer. Utilization of the channel instrument as a viscometer was formulated in terms of physical meanings of measurements such as the flow length and elapsed time. 展开更多
关键词 Liquid food non-Newtonian VISCOSITY flow channel flow analysis viscometer
下载PDF
粘度法测定驱油用聚丙烯酰胺分子量常见问题分析 被引量:2
12
作者 何冬月 《中国石油和化工标准与质量》 2011年第11期69-69,共1页
论述了测量聚丙烯酰胺产品特性粘数及分子量的影响因素。确定了粘度计常数的选取范围,明确稀释溶液浓度的配制要求。分析了不同分子量聚丙烯酰胺在数据处理过程中可能出现的问题。建议取Huggins方程外推截距作为特性粘数值。
关键词 特性粘数limiting viscosity number 聚丙烯酰胺polyacrylamide 粘度计常数Ubbelohde viscometer canstant
原文传递
Experimental Viscosity Measurements for Copper Oxide Nanoparticle Suspensions 被引量:10
13
作者 李俊明 李泽梁 王补宣 《Tsinghua Science and Technology》 SCIE EI CAS 2002年第2期198-201,共4页
The viscosity of water with copper oxide nanoparticle suspensions was measured using capillary viscometers. The mass fractions of copper oxide nanoparticles in the experiment, w , varied between 0.02 and 0.10, a... The viscosity of water with copper oxide nanoparticle suspensions was measured using capillary viscometers. The mass fractions of copper oxide nanoparticles in the experiment, w , varied between 0.02 and 0.10, and the temperature range was 30℃ to 80℃. The experimental results show that the temperature was the major factor affecting the viscosity of the nanoparticle suspensions, while the effect of the mass fraction on the viscosity was not so obvious as that of the temperature for the mass fractions chosen in the experiment. The effect of the capillary tube size on the viscosity was also found to be relatively important at higher mass fractions. 展开更多
关键词 nanoparticle suspensions VISCOSITY capillary viscometer
原文传递
Lifetime Evaluation of Medium and Small Size Power Transformers —— Part 2 : Experimental Study
14
作者 郭永基 代有杰 《Tsinghua Science and Technology》 SCIE EI CAS 1997年第4期72-76,共5页
This paper is the experimental verification of the theoretical analysis in Part 1 of a new method to evaluate the lifetime of power transformers. A new experimental method is proposed to detect the degree of polymeriz... This paper is the experimental verification of the theoretical analysis in Part 1 of a new method to evaluate the lifetime of power transformers. A new experimental method is proposed to detect the degree of polymerization (D P) values during the paper aging process. Experiments show that the aging process of insulating paper is related to the temperature, the oxygen and the water content. If the oxygen and the water content are low, the D P value decreases logarithmically with time. At the same temperature level, D P values are submitted to normal distribution. Applying the presented methodology, expected lifetime of new type of power transformer SBS9 is evaluated. 展开更多
关键词 DEGRADATION capillary viscometer normal distribution
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部