Fiber optic Fourier transform white-light inter-fereometry is presented to interrogate the absolute optical path difference of an Maeh-Zehnder interferometer. The phase change of the interferometer caused by scanning ...Fiber optic Fourier transform white-light inter-fereometry is presented to interrogate the absolute optical path difference of an Maeh-Zehnder interferometer. The phase change of the interferometer caused by scanning wavelength can be calculated by a Fourier transform-based phase demodulation technique. A linear output is achieved.展开更多
Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colore...Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colorectal lesions in the Chinese population.Methods This was a multicenter,single-blind,randomized,controlled trial with a non-inferiority design.Patients undergoing endoscopy for physical examination,screening,and surveillance were enrolled from July 2017 to December 2020.The primary outcome measure was the adenoma detection rate(ADR),defined as the proportion of patients with at least one adenoma detected.The associated factors for detecting adenomas were assessed using univariate and multivariate logistic regression.Results Out of 653 eligible patients enrolled,data from 596 patients were analyzed.The ADRs were 34.5%in the SD-WL group,33.5%in the HD-WL group,and 37.5%in the HD-NBI group(P=0.72).The advanced neoplasm detection rates(ANDRs)in the three arms were 17.1%,15.5%,and 10.4%(P=0.17).No significant differences were found between the SD group and HD group regarding ADR or ANDR(ADR:34.5%vs.35.6%,P=0.79;ANDR:17.1%vs.13.0%,P=0.16,respectively).Similar results were observed between the HD-WL group and HD-NBI group(ADR:33.5%vs.37.7%,P=0.45;ANDR:15.5%vs.10.4%,P=0.18,respectively).In the univariate and multivariate logistic regression analyses,neither HD-WL nor HD-NBI led to a significant difference in overall adenoma detection compared to SD-WL(HD-WL:OR 0.91,P=0.69;HD-NBI:OR 1.15,P=0.80).Conclusion HD-NBI and HD-WL are comparable to SD-WL for overall adenoma detection among Chinese outpatients.It can be concluded that HD-NBI or HD-WL is not superior to SD-WL,but more effective instruction may be needed to guide the selection of different endoscopic methods in the future.Our study’s conclusions may aid in the efficient allocation and utilization of limited colonoscopy resources,especially advanced imaging technologies.展开更多
Atomic nonlinear interferometry has wide applications in quantum metrology and quantum information science.Here we propose a nonlinear time-reversal interferometry scheme with high robustness and metrological gain bas...Atomic nonlinear interferometry has wide applications in quantum metrology and quantum information science.Here we propose a nonlinear time-reversal interferometry scheme with high robustness and metrological gain based on the spin squeezing generated by arbitrary quadratic collective-spin interaction,which could be described by the Lipkin–Meshkov–Glick(LMG)model.We optimize the squeezing process,encoding process,and anti-squeezing process,finding that the two particular cases of the LMG model,one-axis twisting and two-axis twisting outperform in robustness and precision,respectively.Moreover,we propose a Floquet driving method to realize equivalent time reverse in the atomic system,which leads to high performance in precision,robustness,and operability.Our study sets a benchmark for achieving high precision and high robustness in atomic nonlinear interferometry.展开更多
The principle and application of optical interferometry to measure the coating thickness of color-coated plates were introduced in this paper.Additionally,several factors affecting the test results,including coating r...The principle and application of optical interferometry to measure the coating thickness of color-coated plates were introduced in this paper.Additionally,several factors affecting the test results,including coating refractive index,wavelength range,and film thickness range setting,were analyzed.Among these,the refractive index of the color coating,which cannot be measured directly,was identified as the key factor.A solution to this problem was proposed.Finally,the optical interference method and the current detection methods,including the micrometer method and the magnetic eddy current method,were analyzed and compared.The results show that optical interferometry has better repeatability and reproducibility than the current methods and show no significant difference from the current methods through statistical tests.Therefore,the method can be applied to the detection of the coating thickness of color-coated plates.展开更多
Recent developments in spectral white-light interferometry(WLI)are reviewed.Firstly,the techniques for obtaining optical spectrum are introduced.Secondly,some novel measurement techniques are reviewed,including the im...Recent developments in spectral white-light interferometry(WLI)are reviewed.Firstly,the techniques for obtaining optical spectrum are introduced.Secondly,some novel measurement techniques are reviewed,including the improved peak-to-peak WLI,improved wavelength-tracking WLI,Fourier transform WLI,and 3×3 coupler based WLI.Furthermore,a hybrid measurement for the intensity-type sensors,interferometric sensors,and fiber Bragg grating sensors is achieved.It is shown that these developments have assisted in the progress of WLI.展开更多
Laser interferometry is an important technique for ultrasensitive detection of motion and displacement.We push the limit of laser interferometry through noise optimization and device engineering.The contribution of no...Laser interferometry is an important technique for ultrasensitive detection of motion and displacement.We push the limit of laser interferometry through noise optimization and device engineering.The contribution of noises other than shot noise is reduced from 92.6%to 62.4%,demonstrating the possibility towards shotnoise-limited measurement.Using noise thermometry,we quantify the laser heating effect and determine the range of laser power values for room-temperature measurements.With detailed analysis and optimization of signal transduction,we achieve 1.2 fm/Hz^(1/2)displacement measurement sensitivity at room temperature in twodimensional(2D)Ca Nb_(2)O_(6)nanomechanical resonators,the best value reported to date among all resonators based on 2D materials.Our work demonstrates a possible pathway towards quantum-noise-limited measurement at room temperature.展开更多
High resolution imaging is achieved using increasingly larger apertures and successively shorter wavelengths.Optical aperture synthesis is an important high-resolution imaging technology used in astronomy.Conventional...High resolution imaging is achieved using increasingly larger apertures and successively shorter wavelengths.Optical aperture synthesis is an important high-resolution imaging technology used in astronomy.Conventional long baseline amplitude interferometry is susceptible to uncontrollable phase fluctuations,and the technical difficulty increases rapidly as the wavelength decreases.The intensity interferometry inspired by HBT experiment is essentially insensitive to phase fluctuations,but suffers from a narrow spectral bandwidth which results in a lack of effective photons.In this study,we propose optical synthetic aperture imaging based on spatial intensity interferometry.This not only realizes diffraction-limited optical aperture synthesis in a single shot,but also enables imaging with a wide spectral bandwidth,which greatly improves the optical energy efficiency of intensity interferometry.And this method is insensitive to the optical path difference between the sub-apertures.Simulations and experiments present optical aperture synthesis diffraction-limited imaging through spatial intensity interferometry in a 100 nm spectral width of visible light,whose maximum optical path difference between the sub-apertures reaches 69λ.This technique is expected to provide a solution for optical aperture synthesis over kilometer-long baselines at optical wavelengths.展开更多
High-order harmonics are ideal probes to resolve the attosecond dynamics of strong-field recollision processes.An easy-to-implement phase mask is utilized to covert the Gaussian beam to TEM01 transverse electromagneti...High-order harmonics are ideal probes to resolve the attosecond dynamics of strong-field recollision processes.An easy-to-implement phase mask is utilized to covert the Gaussian beam to TEM01 transverse electromagnetic mode,allowing the realization of two-source interferometry of high-order harmonics.We experimentally measure the intensity dependence of dipole phase directly with high-order harmonic interferometry,in which the driving laser intensity can be precisely adjusted.The classical electron excursion simulations reproduce the experimental findings quite well,demonstrating that Coulomb potential plays subtle roles on movement of electrons for harmonics near the ionization threshold.This work is of great importance for precision measurements of ultrafast dynamics in strong-field physics.展开更多
Measurements of frictional resistance play an important role in engineering practice. There are several types of air resistance acting on an aircraft, for example. One of them, frictional resistance, accounts for half...Measurements of frictional resistance play an important role in engineering practice. There are several types of air resistance acting on an aircraft, for example. One of them, frictional resistance, accounts for half of the air resistance. Oil film interferometry is one of methods for measuring the frictional resistance. Oil dropped on an object is thinly stretched by the frictional resistance. The bright and dark fringe pattern is generated when monochromatic light is applied to the oil film. The gradient of the oil thickness decreases with the lapse of time, and thus the spacing between neighboring the dark lines increases. The rate at which the spacing increases is proportional to the frictional resistance. In this study, the frictional resistance acting on a small area on a plate was measured and compared with the theoretical value. As a result, these results qualitatively agree well with each other.展开更多
基金supported by the Program for New Century Excellent Talents (NCET) in the University of China and National 863 Program under Grant No. 2008AA04Z406.
文摘Fiber optic Fourier transform white-light inter-fereometry is presented to interrogate the absolute optical path difference of an Maeh-Zehnder interferometer. The phase change of the interferometer caused by scanning wavelength can be calculated by a Fourier transform-based phase demodulation technique. A linear output is achieved.
基金supported by the Beijing Municipal Science and Technology Commission(BMSTC,No.D171100002617001).
文摘Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colorectal lesions in the Chinese population.Methods This was a multicenter,single-blind,randomized,controlled trial with a non-inferiority design.Patients undergoing endoscopy for physical examination,screening,and surveillance were enrolled from July 2017 to December 2020.The primary outcome measure was the adenoma detection rate(ADR),defined as the proportion of patients with at least one adenoma detected.The associated factors for detecting adenomas were assessed using univariate and multivariate logistic regression.Results Out of 653 eligible patients enrolled,data from 596 patients were analyzed.The ADRs were 34.5%in the SD-WL group,33.5%in the HD-WL group,and 37.5%in the HD-NBI group(P=0.72).The advanced neoplasm detection rates(ANDRs)in the three arms were 17.1%,15.5%,and 10.4%(P=0.17).No significant differences were found between the SD group and HD group regarding ADR or ANDR(ADR:34.5%vs.35.6%,P=0.79;ANDR:17.1%vs.13.0%,P=0.16,respectively).Similar results were observed between the HD-WL group and HD-NBI group(ADR:33.5%vs.37.7%,P=0.45;ANDR:15.5%vs.10.4%,P=0.18,respectively).In the univariate and multivariate logistic regression analyses,neither HD-WL nor HD-NBI led to a significant difference in overall adenoma detection compared to SD-WL(HD-WL:OR 0.91,P=0.69;HD-NBI:OR 1.15,P=0.80).Conclusion HD-NBI and HD-WL are comparable to SD-WL for overall adenoma detection among Chinese outpatients.It can be concluded that HD-NBI or HD-WL is not superior to SD-WL,but more effective instruction may be needed to guide the selection of different endoscopic methods in the future.Our study’s conclusions may aid in the efficient allocation and utilization of limited colonoscopy resources,especially advanced imaging technologies.
基金Project supported by the National Key R&D Program of China (Grant No.2023YFA1407600)the National Natural Science Foundation of China (Grant Nos.12275145,92050110,91736106,11674390,and 91836302)。
文摘Atomic nonlinear interferometry has wide applications in quantum metrology and quantum information science.Here we propose a nonlinear time-reversal interferometry scheme with high robustness and metrological gain based on the spin squeezing generated by arbitrary quadratic collective-spin interaction,which could be described by the Lipkin–Meshkov–Glick(LMG)model.We optimize the squeezing process,encoding process,and anti-squeezing process,finding that the two particular cases of the LMG model,one-axis twisting and two-axis twisting outperform in robustness and precision,respectively.Moreover,we propose a Floquet driving method to realize equivalent time reverse in the atomic system,which leads to high performance in precision,robustness,and operability.Our study sets a benchmark for achieving high precision and high robustness in atomic nonlinear interferometry.
文摘The principle and application of optical interferometry to measure the coating thickness of color-coated plates were introduced in this paper.Additionally,several factors affecting the test results,including coating refractive index,wavelength range,and film thickness range setting,were analyzed.Among these,the refractive index of the color coating,which cannot be measured directly,was identified as the key factor.A solution to this problem was proposed.Finally,the optical interference method and the current detection methods,including the micrometer method and the magnetic eddy current method,were analyzed and compared.The results show that optical interferometry has better repeatability and reproducibility than the current methods and show no significant difference from the current methods through statistical tests.Therefore,the method can be applied to the detection of the coating thickness of color-coated plates.
基金This work was supported by the National Natural Scientific Foundation of China(51075037)the Program for New Century Excellent Talents(NCET)at the University of China and Chinese 863 Project(2008AA04Z406).
文摘Recent developments in spectral white-light interferometry(WLI)are reviewed.Firstly,the techniques for obtaining optical spectrum are introduced.Secondly,some novel measurement techniques are reviewed,including the improved peak-to-peak WLI,improved wavelength-tracking WLI,Fourier transform WLI,and 3×3 coupler based WLI.Furthermore,a hybrid measurement for the intensity-type sensors,interferometric sensors,and fiber Bragg grating sensors is achieved.It is shown that these developments have assisted in the progress of WLI.
基金the National Key R&D Program of China(Grant No.2022YFB3203600)the National Natural Science Foundation of China(Grant Nos.62150052,62250073,U21A20459,62004026,61774029,62104029,and 12104086)+2 种基金the Sichuan Science and Technology Program(Grant No.2021YJ0517 and 2021JDTD0028)the Natural Science Foundation of Hunan Province(Grant No.2021JJ40780)the Science and Technology Innovation Program of Hunan Province“Hu Xiang Young Talents”(Grant No.2021RC3021)。
文摘Laser interferometry is an important technique for ultrasensitive detection of motion and displacement.We push the limit of laser interferometry through noise optimization and device engineering.The contribution of noises other than shot noise is reduced from 92.6%to 62.4%,demonstrating the possibility towards shotnoise-limited measurement.Using noise thermometry,we quantify the laser heating effect and determine the range of laser power values for room-temperature measurements.With detailed analysis and optimization of signal transduction,we achieve 1.2 fm/Hz^(1/2)displacement measurement sensitivity at room temperature in twodimensional(2D)Ca Nb_(2)O_(6)nanomechanical resonators,the best value reported to date among all resonators based on 2D materials.Our work demonstrates a possible pathway towards quantum-noise-limited measurement at room temperature.
基金supported by National Natural Foundation of China(Grant No.61991454)the project of CAS Interdisciplinary Innovation Team。
文摘High resolution imaging is achieved using increasingly larger apertures and successively shorter wavelengths.Optical aperture synthesis is an important high-resolution imaging technology used in astronomy.Conventional long baseline amplitude interferometry is susceptible to uncontrollable phase fluctuations,and the technical difficulty increases rapidly as the wavelength decreases.The intensity interferometry inspired by HBT experiment is essentially insensitive to phase fluctuations,but suffers from a narrow spectral bandwidth which results in a lack of effective photons.In this study,we propose optical synthetic aperture imaging based on spatial intensity interferometry.This not only realizes diffraction-limited optical aperture synthesis in a single shot,but also enables imaging with a wide spectral bandwidth,which greatly improves the optical energy efficiency of intensity interferometry.And this method is insensitive to the optical path difference between the sub-apertures.Simulations and experiments present optical aperture synthesis diffraction-limited imaging through spatial intensity interferometry in a 100 nm spectral width of visible light,whose maximum optical path difference between the sub-apertures reaches 69λ.This technique is expected to provide a solution for optical aperture synthesis over kilometer-long baselines at optical wavelengths.
基金supported by the National Key Research and Development Program of China(Grant No.2019YFA0307703)the National Natural Science Foundation of China(Grant Nos.12234020 and 11974426)。
文摘High-order harmonics are ideal probes to resolve the attosecond dynamics of strong-field recollision processes.An easy-to-implement phase mask is utilized to covert the Gaussian beam to TEM01 transverse electromagnetic mode,allowing the realization of two-source interferometry of high-order harmonics.We experimentally measure the intensity dependence of dipole phase directly with high-order harmonic interferometry,in which the driving laser intensity can be precisely adjusted.The classical electron excursion simulations reproduce the experimental findings quite well,demonstrating that Coulomb potential plays subtle roles on movement of electrons for harmonics near the ionization threshold.This work is of great importance for precision measurements of ultrafast dynamics in strong-field physics.
文摘Measurements of frictional resistance play an important role in engineering practice. There are several types of air resistance acting on an aircraft, for example. One of them, frictional resistance, accounts for half of the air resistance. Oil film interferometry is one of methods for measuring the frictional resistance. Oil dropped on an object is thinly stretched by the frictional resistance. The bright and dark fringe pattern is generated when monochromatic light is applied to the oil film. The gradient of the oil thickness decreases with the lapse of time, and thus the spacing between neighboring the dark lines increases. The rate at which the spacing increases is proportional to the frictional resistance. In this study, the frictional resistance acting on a small area on a plate was measured and compared with the theoretical value. As a result, these results qualitatively agree well with each other.