期刊文献+
共找到172篇文章
< 1 2 9 >
每页显示 20 50 100
Association of accelerometer-measured sleep duration and different intensities of physical activity with incident type 2 diabetes in a population-based cohort study 被引量:2
1
作者 Xinyi Jin Yilin Chen +8 位作者 Hongliang Feng Mingqing Zhou Joey W.Y.Chang Yaping Liu Alice Pik Shan Kong Xiao Tan Yun-Kwok Wing Yannis Yan Liang Jihui Zhang 《Journal of Sport and Health Science》 SCIE CAS CSCD 2024年第2期222-232,共11页
Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a populat... Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a population-based prospective cohort study.Methods:Altogether,88,000 participants(mean age=62.2±7.9 years,mean±SD)were included from the UK Biobank.Sleep duration(short:<6 h/day;normal:6-8 h/day;long:>8 h/day)and PA of different intensities were measured using a wrist-won accelerometer over a 7-day period between 2013 and 2015.PA was classified according to the median or World Health Organization-recommendation:total volume of PA(high,low),moderate-to-vigorous PA(MVPA)(recommended,not recommended),and light-intensity PA(high,low).Incidence of type 2diabetes was ascertained using hospital records or death registries.Results:During a median follow-up of 7.0 years,1615 incident type 2 diabetes cases were documented.Compared with normal sleep duration,short(hazard ratio(HR)=1.21,95%confidence interval(95%CI):1.03-1.41)but not long sleep duration(HR=1.01,95%CI:0.89-1.15)was associated with excessive type 2 diabetes risk.This increased risk among short sleepers seems to be protected against by PA.Compared with normal sleepers with high or recommended PA,short sleepers with low volume of PA(HR=1.81,95%CI:1.46-2.25),not recommended(below the World Health Organization-recommended level of)MVPA(HR=1.92,95%CI:1.55-2.36),or low light-intensity PA(HR=1.49,95%CI:1.13-1.90)had a higher risk of type 2 diabetes,while short sleepers with a high volume of PA(HR=1.14,95%CI:0.88-1.49),recommended MVPA(HR=1.02,95%CI:0.71-1.48),or high light-intensity PA(HR=1.14,95%CI:0.92-1.41)did not.Conclusion:Accelerometer-measured short but not long sleep duration was associated with a higher risk of incident type 2 diabetes.A higher level of PA,regardless of intensity,potentially ameliorates this excessive risk. 展开更多
关键词 Light physical activity Sleep duration Triaxial accelerometer Type 2 diabetes UK Biobank
下载PDF
Efficient Real-Time Devices Based on Accelerometer Using Machine Learning for HAR on Low-Performance Microcontrollers
2
作者 Manh-Tuyen Vi Duc-Nghia Tran +2 位作者 Vu Thi Thuong Nguyen Ngoc Linh Duc-Tan Tran 《Computers, Materials & Continua》 SCIE EI 2024年第10期1729-1756,共28页
Analyzing physical activities through wearable devices is a promising research area for improving health assessment.This research focuses on the development of an affordable and real-time Human Activity Recognition(HA... Analyzing physical activities through wearable devices is a promising research area for improving health assessment.This research focuses on the development of an affordable and real-time Human Activity Recognition(HAR)system designed to operate on low-performance microcontrollers.The system utilizes data from a bodyworn accelerometer to recognize and classify human activities,providing a cost-effective,easy-to-use,and highly accurate solution.A key challenge addressed in this study is the execution of efficient motion recognition within a resource-constrained environment.The system employs a Random Forest(RF)classifier,which outperforms Gradient Boosting Decision Trees(GBDT),Support Vector Machines(SVM),and K-Nearest Neighbors(KNN)in terms of accuracy and computational efficiency.The proposed features Average absolute deviation(AAD),Standard deviation(STD),Interquartile range(IQR),Range,and Root mean square(RMS).The research has conducted numerous experiments and comparisons to establish optimal parameters for ensuring system effectiveness,including setting a sampling frequency of 50 Hz and selecting an 8-s window size with a 40%overlap between windows.Validation was conducted on both the WISDM public dataset and a self-collected dataset,focusing on five fundamental daily activities:Standing,Sitting,Jogging,Walking,and Walking the stairs.The results demonstrated high recognition accuracy,with the system achieving 96.7%on the WISDM dataset and 97.13%on the collected dataset.This research confirms the feasibility of deploying HAR systems on low-performance microcontrollers and highlights the system’s potential applications in patient support,rehabilitation,and elderly care. 展开更多
关键词 accelerometer CLASSIFICATION wearable computing activity recognition HAR
下载PDF
Design and simulation of an accelerometer based on NV center spin–strain coupling
3
作者 季鲁敏 赵立业 王裕海 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期192-198,共7页
The nitrogen-vacancy (NV) center quantum systems have emerged as versatile tools in the field of precision measurement because of their high sensitivity in spin state detection and miniaturization potential as solid-s... The nitrogen-vacancy (NV) center quantum systems have emerged as versatile tools in the field of precision measurement because of their high sensitivity in spin state detection and miniaturization potential as solid-state platforms.In this paper,an acceleration sensing scheme based on NV spin–strain coupling is proposed,which can effectively eliminate the influence of the stray noise field introduced by traditional mechanical schemes.Through the finite element simulation,it is found that the measurement bandwidth of this ensemble NV spin system ranges from 3 kHz to hundreds of kHz with structure√optimization.The required power is at the sub-μW level,corresponding to a noise-limited sensitivity of 6.7×10^(-5) /√Hz.Compared with other types of accelerometers,this micro-sized diamond sensor proposed here has low power consumption,exquisite sensitivity,and integration potential.This research opens a fresh perspective to realize an accelerometer with appealing comprehensive performance applied in biomechanics and inertial measurement fields. 展开更多
关键词 nitrogen-vacancy(NV)accelerometer spin–strain DIAMOND
原文传递
Trajectory of Walking Function in Late-Stage Older Individuals Managed with a Regular Exercise Program: A 5-Year Longitudinal Tracking with an IoT Gait Analysis System Using Accelerometers
4
作者 Taisuke Ito 《Open Journal of Therapy and Rehabilitation》 2024年第2期174-184,共11页
Purpose: This study focused on maintaining and improving the walking function of late-stage older individuals while longitudinally tracking the effects of regular exercise programs in a day-care service specialized fo... Purpose: This study focused on maintaining and improving the walking function of late-stage older individuals while longitudinally tracking the effects of regular exercise programs in a day-care service specialized for preventive care over 5 years, using detailed gait function measurements with an accelerometer-based system. Methods: Seventy individuals (17 male and 53 female) of a daycare service in Tokyo participated in a weekly exercise program, meeting 1 - 2 times. The average age of the participants at the start of the program was 81.4 years. Gait function, including gait speed, stride length, root mean square (RMS) of acceleration, gait cycle time and its standard deviation, and left-right difference in stance time, was evaluated every 6 months. Results: Gait speed and stride length improved considerably within six months of starting the exercise program, confirming an initial improvement in gait function. This suggests that regular exercise programs can maintain or improve gait function even age groups that predictably have a gradual decline in gait ability due to enhanced age. In the long term, many indicators tended to approach baseline values. However, the exercise program seemingly counteracts age-related changes in gait function and maintains a certain level of function. Conclusions: While a decline in gait ability with aging is inevitable, establishing appropriate exercise habits in late-stage older individuals may contribute to long-term maintenance of gait function. 展开更多
关键词 Late-Stage Elderly Exercise Gait Function accelerometer IoT-Based Gait Analysis Device
下载PDF
Vector fiber Bragg gratings accelerometer based on silicone compliant cylinder for low frequency vibration monitoring
5
作者 胡文玉 陈卓 +3 位作者 尤江山 王若晖 周锐 乔学光 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期33-39,共7页
Vector accelerometer has attracted much attention for its great application potential in underground seismic signal measurement. We propose and demonstrate a novel vector accelerometer based on the three fiber Bragg g... Vector accelerometer has attracted much attention for its great application potential in underground seismic signal measurement. We propose and demonstrate a novel vector accelerometer based on the three fiber Bragg gratings(FBGs)embedded in a silicone rubber compliant cylinder at 120° distributed uniformly. The accelerometer is capable of detecting the orientation of vibration with a range of 0°–360° and the acceleration through monitoring the central wavelength shifts of three FBGs simultaneously. The experimental results show that the natural frequency of the accelerometer is about 85 Hz, and the sensitivity is 84.21 pm/g in the flat range of 20 Hz–60 Hz. Through experimental calibration, the designed accelerometer can accurately obtain vibration vector information, including vibration orientation and acceleration. In addition, the range of resonant frequency and sensitivity can be expanded by adjusting the hardness of the silicone rubber materials. Due to the characteristics of small size and orientation recognition, the accelerometer can be applied to low-frequency vibration acceleration vector measurement in narrow spaces. 展开更多
关键词 fiber-optic sensor vector accelerometer silicone compliant cylinder orientation recognition
原文传递
Bulk-Silicon Resonant Accelerometer 被引量:3
6
作者 贾玉斌 郝一龙 张嵘 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2005年第2期281-286,共6页
Resonant accelerometer is designed,which includes two double-ended tuning forks,a proof mass,four-leverage system amplifying inertial force,and drive/sense combs.Each tuning fork is electrostatically actuated and sens... Resonant accelerometer is designed,which includes two double-ended tuning forks,a proof mass,four-leverage system amplifying inertial force,and drive/sense combs.Each tuning fork is electrostatically actuated and sensed at resonance using comb electrodes.The device is fabricated using MEMS bulk-silicon technology,whose sensitive degree is 27 3Hz/g,and the resolution is 167 8μg. 展开更多
关键词 MEMS accelerometer resonant driving and sensing bulk-silicon process frequency shift
下载PDF
Calculation,Simulation,and Testing for the Natural Frequency of a Micro Accelerometer 被引量:2
7
作者 熊继军 范波 +1 位作者 郭虎岗 高建飞 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2008年第9期1715-1722,共8页
A calculation and test method for the natural frequency of a high-g micro accelerometer with complex structures is presented. A universal formula for natural frequency, which can significantly simplify the structural ... A calculation and test method for the natural frequency of a high-g micro accelerometer with complex structures is presented. A universal formula for natural frequency, which can significantly simplify the structural design process, is deduced and confirmed by experiment. A simplified analytical model is established to describe the accelerometer's mechanical behavior and deduce the formula for the natural frequency. Finite element modeling is also conducted to evaluate the natural frequency of the micro-accelerometer and verify the formula. The results obtained from the analytical model and the finite element simulation show good agreement. Finally, a shock comparison method designed for acquiring the high frequency characteristics of the accelerometer is introduced to verify the formula by testing its actual natural frequency. 展开更多
关键词 natural frequency micro accelerometer Rayleigh-Ritz formula
下载PDF
ATTITUDE MEASUREMENT ON HIGH-SPINNING PROJECTILE USING MAGNETIC SENSORS AND ACCELEROMETERS 被引量:5
8
作者 李玎 卜雄洙 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2008年第2期106-112,共7页
In allusion to the limitations of the traditional attitude measurement system consisting of a three-axis magnetic sensor and two accelerometers on high-spinning projectile, a new scheme comprised of two magnetic senso... In allusion to the limitations of the traditional attitude measurement system consisting of a three-axis magnetic sensor and two accelerometers on high-spinning projectile, a new scheme comprised of two magnetic sensors and two accelerometers installed in a particular way is given. The configuration of the sensors is described. The calculation method and the mathematical model of the projectile attitude based on the sensor configuration are discussed. The basic calculation method including the Magsonde Window, the proof of the ratios of maximums and minimums and the calculation of the attitude angles are analyzed in theory. Finally, the system is simulated under the given conditions. The simulation result indicates that the estimated attitude angles are in agreement with the true attitude angles. 展开更多
关键词 PROJECTILE MAGNETOMETERS accelerometers attitude solution digital simulation
下载PDF
Fabrication and Characterization of Tunneling Current of Anodic Bonded Dry-Etched MEMS Tunneling Accelerometer 被引量:1
9
作者 董海峰 郝一龙 +3 位作者 贾玉斌 闫桂珍 王颖 李婷 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2004年第12期1606-1611,共6页
A tunneling accelerometer is fabricated and characterized based on the extension of the silicon-glass anodic-bonding and deep etching releasing process provided by Peking University.The tunneling current under open lo... A tunneling accelerometer is fabricated and characterized based on the extension of the silicon-glass anodic-bonding and deep etching releasing process provided by Peking University.The tunneling current under open loop operation is tested in the air by HP4145B semiconductor analyzer,which verifies the presence of tunneling current and the exponential relationship between tunneling gap and tunneling current.The tunneling barrier is extrapolated to be from 1.182 to 2.177eV.The threshold voltages are tested to be 14~16V for most of the devices.The threshold voltages under -1,0,and +1g are tested,respectively,which shows the sensitivity of the accelerometer is about 87mV/g. 展开更多
关键词 tunneling effect accelerometer MEMS EEACC:0580 7280 2575
下载PDF
A Novel Capacitive Biaxial Microaccelerometer Based on the Slide-Film Damping Effect 被引量:1
10
作者 董林玺 颜海霞 +1 位作者 钱忺 孙玲玲 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2008年第2期219-223,共5页
A novel capacitive biaxial microaccelerometer with a highly symmetrical microstructure is developed. The sensor is composed of a single seismic mass, grid strip, supporting beam, joint beam, and damping adjusting comb... A novel capacitive biaxial microaccelerometer with a highly symmetrical microstructure is developed. The sensor is composed of a single seismic mass, grid strip, supporting beam, joint beam, and damping adjusting combs. The sensing method of changing capacitance area is used in the design,which depresses the requirement of the DRIE process, and de- creases electronic noise by increasing sensing voltage to improve the resolution. The parameters and characteristics of the biaxial microaccelerometer are discussed with the FEM tool ANSYS. The simulated results show that the transverse sensitivity of the sensor is equal to zero. The testing devices based on the slide-film damping effect are fabricated, and the testing quality factor is 514, which shows that the designed structure can improve the resolution and proves the feasibility of the designed process. 展开更多
关键词 capacitive accelerometer inertial sensor high resolution MEMS
下载PDF
System-Level Modeling and Simulation of Force-Balance MEMS Accelerometers 被引量:1
11
作者 张宇峰 刘晓为 陈伟平 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2008年第5期917-922,共6页
This paper presents two approaches for system-level simulation of force-balance accelerometers. The derivation of the system-level model is elaborated and simulation results are obtained from the implementation of tho... This paper presents two approaches for system-level simulation of force-balance accelerometers. The derivation of the system-level model is elaborated and simulation results are obtained from the implementation of those strategies on the fabricated silicon force-balance MEMS accelerometer. The mathematical model presented is implemented in VHDL- AMS and SIMULINK TM,respectively. The simulation results from the two approaches are compared and show a slight difference. Using VHDL-AMS is flexible,reusable,and more accurate. But there is not a mature solver developed for the language and this approach takes more time, while the simulation model can be easily built and quickly evaluated using SIMULINK. 展开更多
关键词 MEMS force-balance accelerometers system-level simulation mathematical model
下载PDF
Review of micromachined optical accelerometers:from mg to sub-μg 被引量:12
12
作者 Qianbo Lu Yinan Wang +3 位作者 Xiaoxu Wang Yuan Yao Xuewen Wang Wei Huang 《Opto-Electronic Advances》 SCIE 2021年第3期1-24,共24页
Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume... Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume and anti-electromagnetic disturbance measurement of acceleration.In recent years,with the in-depth research and development of MOEMS accelerometers,the community is flourishing with the possible applications in seismic monitoring,inertial navigation,aerospace and other industrial and military fields.There have been a variety of schemes of MOEMS accelerometers,whereas the performances differ greatly due to different measurement principles and corresponding application requirements.This paper aims to address the pressing issue of the current lack of systematic review of MOEMS accelerometers.According to the optical measurement principle,we divide the MOEMS accelerometers into three categories:the geometric optics based,the wave optics based,and the new optomechanical accelerometers.Regarding the most widely studied category,the wave optics based accelerometers are further divided into four sub-categories,which is based on grating interferometric cavity,Fiber Bragg Grating(FBG),Fabry-Perot cavity,and photonic crystal,respectively.Following a brief introduction to the measurement principles,the typical performances,advantages and disadvantages as well as the potential application scenarios of all kinds of MOEMS accelerometers are discussed on the basis of typical demonstrations.This paper also presents the status and development tendency of MOEMS accelerometers to meet the ever-increasing demand for high-precision acceleration measurement. 展开更多
关键词 accelerometer Micro-Opto-Electro-Mechanical Systems(MOEMS) integrated optics accelerometer review
下载PDF
Analysis and Design of an Accelerometer Fabricated with Porous Silicon as Sacrificial Layer
13
作者 周俊 王晓红 +2 位作者 姚朋军 董良 刘理天 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2003年第7期687-692,共6页
A piezoresistive silicon accelerometer fabricated by a selective,self-stopping porous silicon (PS) etching method using an epitaxial layer for movable microstructures is described and analyzed.The technique is capable... A piezoresistive silicon accelerometer fabricated by a selective,self-stopping porous silicon (PS) etching method using an epitaxial layer for movable microstructures is described and analyzed.The technique is capable of constructing a microstructure precisely.PS is used as a sacrificial layer,and releasing holes are etched in the film.TMAH solution with additional Si powder and (NH_4)_2S_2O_8 is used to remove PS through the small releasing holes without eroding uncovered Al.The designed fabrication process is full compatible with standard CMOS process. 展开更多
关键词 accelerometer porous silicon MICROMACHINING sacrificial layer MEMS
下载PDF
A Survey of Error Analysis and Calibration Methods for MEMS Triaxial Accelerometers
14
作者 Bo Xiao Yinghang Jiang +2 位作者 Qi Liu Xiaodong Liu Mingxu Sun 《Computers, Materials & Continua》 SCIE EI 2020年第7期389-399,共11页
MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safe... MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safety we need to calibrate MEMS accelerometers.Many authors have improved accelerometer accuracy by calculating calibration parameters,and a large number of published calibration methods have been confusing.In this context,this paper introduces these techniques and methods,analyzes and summarizes the main error models and calibration procedures,and provides useful suggestions.Finally,the content of the accelerometer calibration method needs to be overcome. 展开更多
关键词 MEMS accelerometer CALIBRATION error analysis accelerometer calibration
下载PDF
基于Accelerometer及GPS的中国优秀男子曲棍球运动员比赛负荷的研究 被引量:10
15
作者 冯锐 陈小平 蔡旭旦 《中国体育科技》 CSSCI 北大核心 2018年第6期59-67,共9页
目的:通过对中国优秀男子曲棍球运动员比赛不同位置Accelerometer及GPS指标进行分析,以期达到对我国曲棍球及集体球类项目比赛的负荷特征更为精准的把控。方法:选取16名辽宁省男子曲棍球运动员的9场关键比赛,每场比赛运动员均佩戴Catap... 目的:通过对中国优秀男子曲棍球运动员比赛不同位置Accelerometer及GPS指标进行分析,以期达到对我国曲棍球及集体球类项目比赛的负荷特征更为精准的把控。方法:选取16名辽宁省男子曲棍球运动员的9场关键比赛,每场比赛运动员均佩戴Catapult公司研发的Optimeye S5信号接收器对数据进行采集,使用Openfield软件对部分数据进行实时监测和记录,赛后编辑数据并进行差异性和相关性分析。结果:比赛平均跑动距离为5 505±2 048 m,加速和减速距离占比为13.2%和7.5%。平均IMA为483±188次,HIE占比为27%。变向尤其左变向次数显著高于加速和减速次数(P<0.01)。前锋进行爆发式运动的频率最高且每分钟HIE及变向次数显著高于前卫和后卫(P<0.05);后卫每分钟加速次数最高且显著高于前卫(P<0.05)。各PlayerLoad TM均与跑动距离呈极强相关性(r>0.9,P<0.01)并与IMA和HIE次数呈高度相关性(r>0.7,P<0.01),2D PlayerLoad TM与各指标相关程度最高。结论与建议:需加强我国曲棍球运动员整体跑动负荷量及高强度跑动与爆发式运动能力,重点训练变向尤其左变向能力。加强前锋磷酸原系统供能及短距离重复冲刺能力,提高瞬时启动、急停和急转等灵敏能力。加强前卫和后卫的有氧系统供能,提高持续跑动能力。重点训练后卫下肢爆发力,提高瞬时加速进行近身抢断的能力。PlayerLoad TM和2D PlayerLoad TM均可作为集体球类项目跑动距离和爆发式运动的有效替代指标。PlayerLoad TM Slow更适合实时监测速度小于2 m·s-1的爆发式运动,后卫HIE更适合使用PlayerLoad TM Slow进行实时监测。 展开更多
关键词 曲棍球 集体球类项目 accelerometer GPS IMA PlayerLoadTM
下载PDF
Novel Resonant Accelerometer with Micro Leverage Fabricated by MEMS Technology 被引量:6
16
作者 HE Gaofa TANG Yike +2 位作者 ZHOU Chuande HE Xiaoping WU Ying 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第3期495-500,共6页
For the purpose of improving the precision of the inertial guidance system,it is necessary to enhance the accuracy of the accelerometer.Combining the micro-fabrication processes with resonant sensor technology,a high-... For the purpose of improving the precision of the inertial guidance system,it is necessary to enhance the accuracy of the accelerometer.Combining the micro-fabrication processes with resonant sensor technology,a high-resolution inertial-grade novel micro resonant accelerometer is studied.Based on the detecting theory of the resonant sensors,the accelerometer is designed,fabricated,and tested.The accelerometer consists of one proofmass,two micro leverages and two double-ended-tuning-fork (DETF) resonators.The sensing principle of this accelerometer is based on that the natural frequency of the DETF resonator shifts with its axial load which is caused by inertial force.The push-pull configuration of the DETF is for temperature compensation.The two-stage micro leverage mechanisms are employed to amplify the force and increase the sensitivity of the accelerometer.The micro leverage and the resonator are modeled for static analysis and nonlinear modal analysis via theory method and finite element method (FEM),respectively.The geometrical parameters of them are optimized.The amplification factor of the leverage is 102,and the sensitivity of the resonator on theory is about 62 Hz/g.The samples of the accelerometer are fabricated with deep reactive ion etching (DRIE) technology which can get a high-aspect ratio structure for contributing a greater sensing-capacitance.The measuring results of the samples by scanning electron microscopy (SEM) show that the process is feasible,because of the complete structure,the sound combs and micro leverages,and the acceptable errors.The frequency of the resonator and the sensitivity of the accelerometer are tested via printed circuit board (PCB),respectively.The result of the test shows that the frequency of the push-resonator is about 54 530 Hz and the sensitivity of the accelerometer is about 55 Hz/g.The amplification factor of the leverage is calculated more accurately because the coupling of the two stages leverage is considered during derivation of the analysis formula.In addition,the novel differential structure of the accelerometer can greatly improve the sensitivity of the accelerometers. 展开更多
关键词 accelerometer RESONATOR MICRO-FABRICATION SENSOR
下载PDF
Design and application of single-antenna GPS/accelerometers attitude determination system 被引量:4
17
作者 He Jie Huang Xianlin Wang Guofeng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第2期220-227,共8页
In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system ... In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system is of large volume, high cost, and complex structure, this approach is presented to determine the attitude based on vector space with single-antenna GPS and accelerometers in the micro inertial measurement unit (MIMU). It can provide real-time and accurate attitude information. Subsequently, the single-antenna GPS/SINS integrated navigation system is designed based on the combination of position, velocity, and attitude. Finally the semi- physical simulations of single-antenna GPS attitude determination system and single-antenna GPS/SINS integrated navigation system are carried out. The simulation results, based on measured data, show that the single-antenna GPS/SINS system can provide more accurate navigation information compared to the GPS/SINS system, based on the combination of position and velocity. Furthermore, the single-antenna GPS/SINS system is characteristic of lower cost and simpler structure. It provides the basis for the application of a single-antenna GPS/SINS integrated navigation system in a micro aerial vehicle (MAV). 展开更多
关键词 single-antenna GPS attitude determination vector space accelerometer integrated navigation MAV.
下载PDF
Structural Design of a Compact in-Plane Nano-Grating Accelerometer 被引量:4
18
作者 YAO Bao-Yin ZHOU Zhen +2 位作者 FENG Li-Shuang WANG Wen-Pu WANG Xiao 《Chinese Physics Letters》 SCIE CAS CSCD 2012年第11期219-223,共5页
A combination of large mass,weak spring and nano-grating is the key for a nano-grating accelerometer to measure nano-G acceleration.A novel compact nano-grating accelerometer integrating a large mass with nano-grating... A combination of large mass,weak spring and nano-grating is the key for a nano-grating accelerometer to measure nano-G acceleration.A novel compact nano-grating accelerometer integrating a large mass with nano-grating is proposed.First,the numbers of diffraction orders are calculated.Then,structure parameters are optimized by finite element analysis to achieve a high sensitivity in an ideal vibration mode.Finally,we design the fabrication method to form such a compact nano-grating accelerometer and successfully fabricate the uniform and well-designed nano-gratings with a period of 847 nm,crater of 451 nm by an FIB/SEM dual beam system.Based on the ANSYS simulation,a nano-grating accelerometer is predicted to work in the first modal and enables the accelerometer to have displacement sensitivity at 197 nm/G with a measurement range of±1 G,corresponding to zeroth diffraction beam optical sensitivity 1%/mG.The nano-gratings fabricated are very close to those designed ones within experimental error to lay the foundation for the sequent fabrication.These results provide a theoretical basis for the design and fabrication of nano-grating accelerometers. 展开更多
关键词 accelerometer BEAM integrating
原文传递
Effect of annealing temperature on the microstructure and optoelectrical properties of ZnO thin films and their application in self-powered accelerometers 被引量:2
19
作者 Xiao-zhou Zhang Yan-ping Xia +3 位作者 Xing Liu Yi-ming Zhong Hai-bo Zhao Pei-hong Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2019年第9期1186-1193,共8页
This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron spu... This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron sputtering machine was used. Polymethyl methacrylate(PMMA) and aluminum-doped zinc oxide(AZO) were used as the insulating layer and the top electrode of the NG, respectively. The experimental results show that the ZnO thin films annealed at 150℃ exhibited the highest crystallinity among the prepared films and an optical band gap of 3.24 eV. The NG fabricated with an AZO/PMMA/ZnO/stainless steel configuration exhibited a higher output voltage than the device with an AZO/ZnO/PMMA/stainless steel configuration. In addition, the annealing temperature affected the open-circuit voltage of the NGs;the output voltage reached 3.81 V when the annealing temperature was 150℃. The open-circuit voltage of the prepared self-powered accelerometer increased linearly with acceleration. In addition, the small NG-based accelerometer, which exhibited excellent fatigue resistance, can be used for acceleration measurements of small and lightweight devices. 展开更多
关键词 piezoelectric ZnO thin film RF MAGNETRON SPUTTERING ANNEALING temperature accelerometer
下载PDF
Response to McAvoy and Tudor-Locke on their commentary on our manuscript:“Association of accelerometer-derived step volume and intensity with hospitalizations and mortality in older adults:A prospective cohort study” 被引量:2
20
作者 Asier Mañas Borja del Pozo Cruz +6 位作者 Ulf Ekelund JoséLosa Reyna Irene Rodríguez Gómez JoséAntonio Carnicero Carreño Leocadio Rodríguez Mañas Francisco J.García García Ignacio Ara 《Journal of Sport and Health Science》 SCIE 2022年第6期639-640,共2页
Dear Editor,We have read with interest the commentary by McAvoy and Tudor-Locke on our article entitled "Association of accelerometer-derived step volume and intensity with ho spitalizations and mortality in olde... Dear Editor,We have read with interest the commentary by McAvoy and Tudor-Locke on our article entitled "Association of accelerometer-derived step volume and intensity with ho spitalizations and mortality in older adults:A prospective cohort study". The authors expressed some concerns about our methodology used to define accelerometer-derived step intensity and the analytical approach applied in our study. 展开更多
关键词 accelerometer prospective MORTALITY
下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部