期刊文献+
共找到98篇文章
< 1 2 5 >
每页显示 20 50 100
Understanding Tremor in Rapid Upper Limb Movements Using 3D Accelerometers Data 被引量:3
1
作者 Paula Pascoal-Faria Miguel Patrício +4 位作者 Adriana Leal Francisco Caramelo António Freire Cristina Januário Miguel Castelo-Branco 《Neuroscience & Medicine》 2014年第5期205-213,共9页
Tremor is a manifestation of a variety of human neurodegenerative diseases, notably Parkinson’s disease (PD) and Essential Tremor (ET), both affecting millions worldwide. PD is primarily caused by a progressive loss ... Tremor is a manifestation of a variety of human neurodegenerative diseases, notably Parkinson’s disease (PD) and Essential Tremor (ET), both affecting millions worldwide. PD is primarily caused by a progressive loss of dopamine neurons in the nigrostriatal system that leads to widespread motor symptoms such as bradykinesia, rigidity, tremor and postural instability. ET typically involves a tremor of the arms, hands or fingers. No definitive test or biomarker is yet available for PD or ET, so the rate of misdiagnosis is relatively high. As tremor is a very common feature at the onset of both diseases, it is crucial to be able to characterize it. This is made possible using acce?lerometers to quantify the tremor amplitude and frequency. In this work we aim to find tasks involving upper limb movements that are suitable to modulate both types of tremor. Four tasks were tested, differing on whether the arms moved together or alternatingly and whether loads were added. Significant differences in tremor measures were found when patients were asked to perform simultaneous rapid arms movements with loads placed on their wrists. These results may allow the design of an efficient fMRI protocol for identifying the cortical circuits responsible for the modulation of tremor. 展开更多
关键词 DISEASE ESSENTIAL TREMOR TREMOR Quantification TREMOR MODULATION accelerometers
下载PDF
Review of micromachined optical accelerometers:from mg to sub-μg 被引量:8
2
作者 Qianbo Lu Yinan Wang +3 位作者 Xiaoxu Wang Yuan Yao Xuewen Wang Wei Huang 《Opto-Electronic Advances》 SCIE 2021年第3期1-24,共24页
Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume... Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume and anti-electromagnetic disturbance measurement of acceleration.In recent years,with the in-depth research and development of MOEMS accelerometers,the community is flourishing with the possible applications in seismic monitoring,inertial navigation,aerospace and other industrial and military fields.There have been a variety of schemes of MOEMS accelerometers,whereas the performances differ greatly due to different measurement principles and corresponding application requirements.This paper aims to address the pressing issue of the current lack of systematic review of MOEMS accelerometers.According to the optical measurement principle,we divide the MOEMS accelerometers into three categories:the geometric optics based,the wave optics based,and the new optomechanical accelerometers.Regarding the most widely studied category,the wave optics based accelerometers are further divided into four sub-categories,which is based on grating interferometric cavity,Fiber Bragg Grating(FBG),Fabry-Perot cavity,and photonic crystal,respectively.Following a brief introduction to the measurement principles,the typical performances,advantages and disadvantages as well as the potential application scenarios of all kinds of MOEMS accelerometers are discussed on the basis of typical demonstrations.This paper also presents the status and development tendency of MOEMS accelerometers to meet the ever-increasing demand for high-precision acceleration measurement. 展开更多
关键词 ACCELEROMETER Micro-Opto-Electro-Mechanical Systems(MOEMS) integrated optics accelerometer review
下载PDF
Effect of annealing temperature on the microstructure and optoelectrical properties of ZnO thin films and their application in self-powered accelerometers 被引量:2
3
作者 Xiao-zhou Zhang Yan-ping Xia +3 位作者 Xing Liu Yi-ming Zhong Hai-bo Zhao Pei-hong Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2019年第9期1186-1193,共8页
This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron spu... This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron sputtering machine was used. Polymethyl methacrylate(PMMA) and aluminum-doped zinc oxide(AZO) were used as the insulating layer and the top electrode of the NG, respectively. The experimental results show that the ZnO thin films annealed at 150℃ exhibited the highest crystallinity among the prepared films and an optical band gap of 3.24 eV. The NG fabricated with an AZO/PMMA/ZnO/stainless steel configuration exhibited a higher output voltage than the device with an AZO/ZnO/PMMA/stainless steel configuration. In addition, the annealing temperature affected the open-circuit voltage of the NGs;the output voltage reached 3.81 V when the annealing temperature was 150℃. The open-circuit voltage of the prepared self-powered accelerometer increased linearly with acceleration. In addition, the small NG-based accelerometer, which exhibited excellent fatigue resistance, can be used for acceleration measurements of small and lightweight devices. 展开更多
关键词 piezoelectric ZnO thin film RF MAGNETRON SPUTTERING ANNEALING temperature ACCELEROMETER
下载PDF
Summary of Research Status and Application of MEMS Accelerometers 被引量:1
4
作者 Weimeng Niu Liqing Fang +4 位作者 Lei Xu Xu Li Ruikun Huo Deqing Guo Ziyuan Qi 《Journal of Computer and Communications》 2018年第12期215-221,共7页
The rapid development of MEMS technology has made MEMS accelerometers mature and the application range has been expanded. Many kinds of MEMS accelerometers are researched. According to the working principle of MEMS ac... The rapid development of MEMS technology has made MEMS accelerometers mature and the application range has been expanded. Many kinds of MEMS accelerometers are researched. According to the working principle of MEMS accelerometer, it can be divided into: piezoresistive, piezoelectric, capacitive, tunnel, resonant, electromagnetic, thermocouple, optical, inductive, etc. Due to its outstanding features in terms of size, quality, power consumption and reliability, MEMS sensors are used in military applications and where high environmental resistance is required. MEMS accelerometers are developing rapidly and have good application prospects. In order to make MEMS accelerometers more widely understood, the advantages of MEMS accelerometers are expounded. The research status of MEMS accelerometers is introduced, and MEMS are analyzed. The application of accelerometers in real-world environments, and the development trend of MEMS accelerometers in the future. More scholars will invest in MEMS accelerometer research, pursuing high performance, low power consumption, high precision, multi-function, and interaction. Strong MEMS accelerometers will be ubiquitous in the future. 展开更多
关键词 MEMS TECHNOLOGY MEMS ACCELEROMETER
下载PDF
Rigid Bridges Health Dynamic Monitoring Using 100 Hz GPS Single-Frequency and Accelerometers 被引量:1
5
作者 Joao Olympio de Araújo Neto Jorge Luiz Alves Trabanco +2 位作者 Ana Paula C.Larocca Andre Luiz Cunha Marcelo Carvalho dos Santos 《Positioning》 2019年第2期17-33,共17页
This article presents the modal frequency recordings of a rigid bridge, monitored by the GPS receivers (Global Positioning System) with a data recording rate of 100 Hz and accelerometers. The GPS data processing was p... This article presents the modal frequency recordings of a rigid bridge, monitored by the GPS receivers (Global Positioning System) with a data recording rate of 100 Hz and accelerometers. The GPS data processing was performed through the double-difference phase, using the adjusted interferometry technique (i.e. phase residue method—PRM&reg). In the method, the double-difference phase of the carrier L1 is realized by using two satellites only, one was positioned at the zenith of the structure and the other satellite was positioned near the horizon. The results of the parametric adjustment of the PRM observations were finalized through software Interferometry, mathematical algorithm were applied and compared with the accelerometer. The comparison served to validate the use of GPS as a fast and reliable instrument for the preliminary monitoring of the dynamic behavior of the bridge, road artworks which are common in several countries, especially in the Brazilian road network. The data time series from the GPS and accelerometers were processed using the Wavelet. The detection of frequencies means that the combination of 100 Hz GPS receivers and the PRM allows detecting vibrations up to 5 mm. It presented significant results which were never obtained by the Fourier Transform. 展开更多
关键词 GPS Rigid Bridge Modal Frequency WAVELET ACCELEROMETER Health Monitoring
下载PDF
A Survey of Error Analysis and Calibration Methods for MEMS Triaxial Accelerometers
6
作者 Bo Xiao Yinghang Jiang +2 位作者 Qi Liu Xiaodong Liu Mingxu Sun 《Computers, Materials & Continua》 SCIE EI 2020年第7期389-399,共11页
MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safe... MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safety we need to calibrate MEMS accelerometers.Many authors have improved accelerometer accuracy by calculating calibration parameters,and a large number of published calibration methods have been confusing.In this context,this paper introduces these techniques and methods,analyzes and summarizes the main error models and calibration procedures,and provides useful suggestions.Finally,the content of the accelerometer calibration method needs to be overcome. 展开更多
关键词 MEMS ACCELEROMETER CALIBRATION error analysis accelerometer calibration
下载PDF
Dose-response associations,physical activity intensity and mortality risk:A narrative review 被引量:1
7
作者 Ulf Ekelund Miguel Adriano Sanchez-Lastra +1 位作者 Knut Eirik Dalene Jakob Tarp 《Journal of Sport and Health Science》 SCIE CSCD 2024年第1期24-29,共6页
Physical activity is consistently associated with reduced mortality,decreased risk for non-communicable diseases,and improved mental health in observational studies.Randomized controlled trials and observational Mende... Physical activity is consistently associated with reduced mortality,decreased risk for non-communicable diseases,and improved mental health in observational studies.Randomized controlled trials and observational Mendelian randomization studies support causal links between physical activity and health outcomes.However,the scarcity of evidence from randomized controlled trials,along with their inherent challenges like exposure contrasts,healthy volunteer biases,loss to follow-up,and limited real-world dose-response data,warrants a comprehensive approach.This review advocates synthesizing insights from diverse study designs to better understand the causal relationship between physical activity,mortality risk,and other health outcomes.Additionally,it summarizes recent research since the publication of current physical activity recommendations.Novel observational studies utilizing device-measured physical activity underscore the importance of every minute of activity and suggest that all intensity levels confer health benefits,with vigorous-intensity potentially requiring lower volumes for substantial benefits.Future guidelines,informed by device-measured physical activity studies,may offer refined age-specific recommendations,emphasize vigorous-intensity physical activity,and include daily step counts as a simple,easily assessable metric using commercial wearables. 展开更多
关键词 accelerometers Non-communicable diseases Public health Sedentary behavior
下载PDF
Association of accelerometer-measured sleep duration and different intensities of physical activity with incident type 2 diabetes in a population-based cohort study
8
作者 Xinyi Jin Yilin Chen +8 位作者 Hongliang Feng Mingqing Zhou Joey W.Y.Chang Yaping Liu Alice Pik Shan Kong Xiao Tan Yun-Kwok Wing Yannis Yan Liang Jihui Zhang 《Journal of Sport and Health Science》 SCIE CAS CSCD 2024年第2期222-232,共11页
Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a populat... Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a population-based prospective cohort study.Methods:Altogether,88,000 participants(mean age=62.2±7.9 years,mean±SD)were included from the UK Biobank.Sleep duration(short:<6 h/day;normal:6-8 h/day;long:>8 h/day)and PA of different intensities were measured using a wrist-won accelerometer over a 7-day period between 2013 and 2015.PA was classified according to the median or World Health Organization-recommendation:total volume of PA(high,low),moderate-to-vigorous PA(MVPA)(recommended,not recommended),and light-intensity PA(high,low).Incidence of type 2diabetes was ascertained using hospital records or death registries.Results:During a median follow-up of 7.0 years,1615 incident type 2 diabetes cases were documented.Compared with normal sleep duration,short(hazard ratio(HR)=1.21,95%confidence interval(95%CI):1.03-1.41)but not long sleep duration(HR=1.01,95%CI:0.89-1.15)was associated with excessive type 2 diabetes risk.This increased risk among short sleepers seems to be protected against by PA.Compared with normal sleepers with high or recommended PA,short sleepers with low volume of PA(HR=1.81,95%CI:1.46-2.25),not recommended(below the World Health Organization-recommended level of)MVPA(HR=1.92,95%CI:1.55-2.36),or low light-intensity PA(HR=1.49,95%CI:1.13-1.90)had a higher risk of type 2 diabetes,while short sleepers with a high volume of PA(HR=1.14,95%CI:0.88-1.49),recommended MVPA(HR=1.02,95%CI:0.71-1.48),or high light-intensity PA(HR=1.14,95%CI:0.92-1.41)did not.Conclusion:Accelerometer-measured short but not long sleep duration was associated with a higher risk of incident type 2 diabetes.A higher level of PA,regardless of intensity,potentially ameliorates this excessive risk. 展开更多
关键词 Light physical activity Sleep duration Triaxial accelerometer Type 2 diabetes UK Biobank
下载PDF
Design and simulation of an accelerometer based on NV center spin–strain coupling
9
作者 季鲁敏 赵立业 王裕海 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期192-198,共7页
The nitrogen-vacancy (NV) center quantum systems have emerged as versatile tools in the field of precision measurement because of their high sensitivity in spin state detection and miniaturization potential as solid-s... The nitrogen-vacancy (NV) center quantum systems have emerged as versatile tools in the field of precision measurement because of their high sensitivity in spin state detection and miniaturization potential as solid-state platforms.In this paper,an acceleration sensing scheme based on NV spin–strain coupling is proposed,which can effectively eliminate the influence of the stray noise field introduced by traditional mechanical schemes.Through the finite element simulation,it is found that the measurement bandwidth of this ensemble NV spin system ranges from 3 kHz to hundreds of kHz with structure√optimization.The required power is at the sub-μW level,corresponding to a noise-limited sensitivity of 6.7×10^(-5) /√Hz.Compared with other types of accelerometers,this micro-sized diamond sensor proposed here has low power consumption,exquisite sensitivity,and integration potential.This research opens a fresh perspective to realize an accelerometer with appealing comprehensive performance applied in biomechanics and inertial measurement fields. 展开更多
关键词 nitrogen-vacancy(NV)accelerometer spin–strain DIAMOND
原文传递
A Novel All-Optical Sensor Design Based on a Tunable Resonant Nanocavity in Photonic Crystal Microstructure Applicable in MEMS Accelerometers 被引量:2
10
作者 Mojtaba HOSSEINZADEH SANI Hamed SAGHAEI +1 位作者 Mohammad Amin MEHRANPOUR Afsaneh ASGARIYAN TABRIZI 《Photonic Sensors》 SCIE EI CSCD 2021年第4期457-471,共15页
In view of the large scientific and technical interest in the microelectromechanical system(MEMS)accelerometer sensor and the limitations of capacitive,resistive piezo,and piezoelectric methods,we focus on the measure... In view of the large scientific and technical interest in the microelectromechanical system(MEMS)accelerometer sensor and the limitations of capacitive,resistive piezo,and piezoelectric methods,we focus on the measurement of the seismic mass displacement using a novel design of the all-optical sensor(AOS).The proposed AOS consists of two waveguides and a ring resonator in a two-dimensional rod-based photonic crystal(PhC)microstructure,and a holder which connects the central rod of a nanocavity to a proof mass.The photonic band structure of the AOS is calculated with the plane-wave expansion approach for TE and TM polarization modes,and the light wave propagation inside the sensor is analyzed by solving MaxwelFs equations using the finite-difference time-domain method.The results of our simulations demonstrate that the fundamental PhC has a free spectral range of about 730 nm covering the optical communication wavelength-bands.Simulations also show that the AOS has the resonant peak of 0.8 at 1.644μm,quality factor of 3288,full width at half maximum of 0.5nm,and figure of merit of 0.97.Furthermore,for the maximum 200nm nanocavity displacements in the x-or y-direction,the resonant wavelengths shift to 1.618μm and 1.547μm,respectively.We also calculate all characteristics of the nanocavity displacement in positive and negative directions of the jc-axis and y-axis.The small area of 104.35μm^(2)and short propagation time of the AOS make it an interesting sensor for various applications,especially in the vehicle navigation systems and aviation safety tools. 展开更多
关键词 Photonic crystal MEMS accelerometer sensor tunable resonator finite-difference time-domain method
原文传递
Calibration of GRACE on-board accelerometers for thermosphere density derivation
11
作者 Min Li Zhuo Lei +3 位作者 Wenwen Li Kecai Jiang Youcun Wang Qile Zhao 《Geo-Spatial Information Science》 SCIE EI CSCD 2022年第1期74-87,共14页
Low Earth Orbit satellite on-board accelerometers play an important role in improving our understanding of thermosphere density;however,the accelerometer-derived densities are subject to accelerometer calibration erro... Low Earth Orbit satellite on-board accelerometers play an important role in improving our understanding of thermosphere density;however,the accelerometer-derived densities are subject to accelerometer calibration errors.In this study,two different dynamic calibration schemes,the accelerometer parameter-incorporated orbit fitting and precise orbit determination(POD),are investigated with the Gravity Recovery And Climate Experiment(GRACE)satellite accelerometers for thermosphere density derivation during years 2004–2007(inclusive).We show that the GRACE accelerometer parametrization can be optimized by fixing scale coefficients and estimating biases every 60 min so that the orbit fitting and POD precision can be improved from 10 cm to 2 cm in the absence of empirical acceleration compensations and as a result the integrity of calibration parameters may be reserved.The orbit-fitting scheme demonstrates similar calibration precision with respect to POD.Their bias estimates in the along-track and cross-track components exhibit an offset within 0.1%and a standard deviation(STD)less than 0.3%.Correspondingly,a bias of 2.20%and a STD of 5.75%exists between their thermosphere density estimates.The orbit-fitting and POD-derived thermosphere densities are validated through the comparison against the results published by other institution.The comparison shows that either of them can achieve a precision level at 6%.To derive thermosphere density from the rapid-increasing amount of on-board accelerometer data sets,it is suggested to take full advantage of the orbit-fitting scheme due to its high efficiency as well as high precision. 展开更多
关键词 GRACE accelerometer calibration thermosphere density precise orbit determination orbit fit
原文传递
Vector fiber Bragg gratings accelerometer based on silicone compliant cylinder for low frequency vibration monitoring
12
作者 胡文玉 陈卓 +3 位作者 尤江山 王若晖 周锐 乔学光 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期33-39,共7页
Vector accelerometer has attracted much attention for its great application potential in underground seismic signal measurement. We propose and demonstrate a novel vector accelerometer based on the three fiber Bragg g... Vector accelerometer has attracted much attention for its great application potential in underground seismic signal measurement. We propose and demonstrate a novel vector accelerometer based on the three fiber Bragg gratings(FBGs)embedded in a silicone rubber compliant cylinder at 120° distributed uniformly. The accelerometer is capable of detecting the orientation of vibration with a range of 0°–360° and the acceleration through monitoring the central wavelength shifts of three FBGs simultaneously. The experimental results show that the natural frequency of the accelerometer is about 85 Hz, and the sensitivity is 84.21 pm/g in the flat range of 20 Hz–60 Hz. Through experimental calibration, the designed accelerometer can accurately obtain vibration vector information, including vibration orientation and acceleration. In addition, the range of resonant frequency and sensitivity can be expanded by adjusting the hardness of the silicone rubber materials. Due to the characteristics of small size and orientation recognition, the accelerometer can be applied to low-frequency vibration acceleration vector measurement in narrow spaces. 展开更多
关键词 fiber-optic sensor vector accelerometer silicone compliant cylinder orientation recognition
原文传递
Research on Human Activity Recognition Algorithm Based on LSTM-1DCNN
13
作者 Yuesheng Zhao Xiaoling Wang +1 位作者 Yutong Luo Muhammad Shamrooz Aslam 《Computers, Materials & Continua》 SCIE EI 2023年第12期3325-3347,共23页
With the rapid advancement of wearable devices,Human Activities Recognition(HAR)based on these devices has emerged as a prominent research field.The objective of this study is to enhance the recognition performance of... With the rapid advancement of wearable devices,Human Activities Recognition(HAR)based on these devices has emerged as a prominent research field.The objective of this study is to enhance the recognition performance of HAR by proposing an LSTM-1DCNN recognition algorithm that utilizes a single triaxial accelerometer.This algorithm comprises two branches:one branch consists of a Long and Short-Term Memory Network(LSTM),while the other parallel branch incorporates a one-dimensional Convolutional Neural Network(1DCNN).The parallel architecture of LSTM-1DCNN initially extracts spatial and temporal features from the accelerometer data separately,which are then concatenated and fed into a fully connected neural network for information fusion.In the LSTM-1DCNN architecture,the 1DCNN branch primarily focuses on extracting spatial features during convolution operations,whereas the LSTM branch mainly captures temporal features.Nine sets of accelerometer data from five publicly available HAR datasets are employed for training and evaluation purposes.The performance of the proposed LSTM-1DCNN model is compared with five other HAR algorithms including Decision Tree,Random Forest,Support Vector Machine,1DCNN,and LSTM on these five public datasets.Experimental results demonstrate that the F1-score achieved by the proposed LSTM-1DCNN ranges from 90.36%to 99.68%,with a mean value of 96.22%and standard deviation of 0.03 across all evaluated metrics on these five public datasets-outperforming other existing HAR algorithms significantly in terms of evaluation metrics used in this study.Finally the proposed LSTM-1DCNN is validated in real-world applications by collecting acceleration data of seven human activities for training and testing purposes.Subsequently,the trained HAR algorithm is deployed on Android phones to evaluate its performance.Experimental results demonstrate that the proposed LSTM-1DCNN algorithm achieves an impressive F1-score of 97.67%on our self-built dataset.In conclusion,the fusion of temporal and spatial information in the measured data contributes to the excellent HAR performance and robustness exhibited by the proposed 1DCNN-LSTM architecture. 展开更多
关键词 Human activity recognition ACCELEROMETER CNN LSTM DEPLOYMENT temporal and spatial information
下载PDF
Wearable monitors criterion validity for energy expenditure in sedentary and light activities
14
作者 Florez-Pregonero Alberto Meckes Nathanael +1 位作者 Buman Mathew Barbara E.Ainsworth 《Journal of Sport and Health Science》 SCIE 2017年第1期103-110,共8页
Background: Wearable monitors(WMs) are used to estimate the time spent in sedentary behaviors(SBs) and light-intensity physical activities(LPAs) and their associated energy cost; however, the accuracy of WMs in measur... Background: Wearable monitors(WMs) are used to estimate the time spent in sedentary behaviors(SBs) and light-intensity physical activities(LPAs) and their associated energy cost; however, the accuracy of WMs in measuring behaviors on the lower end of the intensity spectrum is unclear. The aim of this study was to assess the validity of 3 WMs(Acti Graph GT3X+; activ PAL, and Sense Wear 2) in estimating the intensity of SB and LPA in adults as compared with the criterion measure of oxygen uptake(VO_2) measured by indirect calorimetry.Methods: Sixteen participants(age: 25.38 ± 8.58 years) wore the ActiG raph GT3X+, activP AL, and SenseW ear 2 devices during 7 sedentary-to-light activities. VO_2(mL/kg/min) was estimated by means of a portable gas analyzer, Oxycon Mobile(Carefusion, Yorba Linda, CA, USA). All data were transformed into metabolic equivalents and analyzed using mean percentage error, equivalence plots, Bland-Altman plots, kappa statistics, and sensitivity/specificity.Results: Mean percentage error was lowest for the activ PAL for SB(14.9%) and LPA(9.3%) compared with other WMs, which were >21.2%.None of the WMs fell within the equivalency range of ±10% of the criterion mean value. Bland-Altman plots revealed narrower levels of agreement with all WMs for SB than for LPA. Kappa statistics were low for all WMs, and sensitivity and specificity varied by WM type.Conclusion: None of the WMs tested in this study were equivalent with the criterion measure(VO_2) in estimating sedentary-to-light activities;however, the activ PAL had greater overall accuracy in measuring SB and LPA than did the Acti Graph and Sense Wear 2 monitors. 展开更多
关键词 accelerometers ACCURACY Low intensity Metabolic estimations Objective measurement Sedentary behaviors
下载PDF
A Combined Alignment Method for Strapdown Inertial Navigation System on Stationary Base
15
作者 Shuai Chen Xinzhi Liu +1 位作者 Qian Sun Ya Zhang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2020年第6期57-71,共15页
Owing to the weak observability of the azimuth misalignment angle,alignment accuracy and time are always the contradictory issues in the initial alignment process of Strapdown Inertial Navigation System(SINS),which re... Owing to the weak observability of the azimuth misalignment angle,alignment accuracy and time are always the contradictory issues in the initial alignment process of Strapdown Inertial Navigation System(SINS),which requires a compromise between them.In this paper,a combined alignment mechanism is proposed to construct an observable and controllable system model,which can effectively achieve higher azimuth alignment accuracy during the fixed time period.First,the Reduced Order Kalman Filter(ROKF)alignment algorithm was utilized to calculate the misalignment angles in parallel with the classical gyrocompass alignment algorithm.Then,the misalignment angles calculated by the gyrocompass alignment method were used to formulate the augmented measurement model with zero velocity models.Finally,the zero velocity model of the ROKF method was switched into the augmented measurement model when the azimuth misalignment angle of the gyrocompass alignment method was close to steady situation.The combined alignment method was analyzed reasonably by the observability and the mathematical deduction.The comparison results of the numerical simulation and the experimental data test showed that the combined method had good performance in terms of estimation accuracy and consistency of the alignment results. 展开更多
关键词 inertial navigation instrumentation and measurement GYROSCOPES accelerometers Kalman filter measurement errors
下载PDF
Analysis for Transverse Sensitivity of the Microaccelerometer
16
作者 Yu LIU Guochao WANG Changwen GUO 《Engineering(科研)》 2009年第3期196-200,共5页
For the microaccelerometer, strong axial response and weak cross-axial one are always expected. This paper presents a general analysis about transverse sensitivity of the microaccelerometer. The analysis model is deve... For the microaccelerometer, strong axial response and weak cross-axial one are always expected. This paper presents a general analysis about transverse sensitivity of the microaccelerometer. The analysis model is developed, where the influence of response stiffness and damping in different axes, as well as symmetrical decline angles of 3 degrees of freedom system is considered. Moreover, multi-freedom vibration equations based on the analysis model are established. And the equations are solved on condition that damping force is ignored. Finally, the theoretical analysis about transverse sensitivity is accomplished, and some effective methods, which are beneficial to reduce cross disturbance, are provided. 展开更多
关键词 MEMS accelerometers TRANSVERSE Sensitivity Multi-Freedom VIBRATION EQUATION
下载PDF
基于Accelerometer及GPS的中国优秀男子曲棍球运动员比赛负荷的研究 被引量:10
17
作者 冯锐 陈小平 蔡旭旦 《中国体育科技》 CSSCI 北大核心 2018年第6期59-67,共9页
目的:通过对中国优秀男子曲棍球运动员比赛不同位置Accelerometer及GPS指标进行分析,以期达到对我国曲棍球及集体球类项目比赛的负荷特征更为精准的把控。方法:选取16名辽宁省男子曲棍球运动员的9场关键比赛,每场比赛运动员均佩戴Catap... 目的:通过对中国优秀男子曲棍球运动员比赛不同位置Accelerometer及GPS指标进行分析,以期达到对我国曲棍球及集体球类项目比赛的负荷特征更为精准的把控。方法:选取16名辽宁省男子曲棍球运动员的9场关键比赛,每场比赛运动员均佩戴Catapult公司研发的Optimeye S5信号接收器对数据进行采集,使用Openfield软件对部分数据进行实时监测和记录,赛后编辑数据并进行差异性和相关性分析。结果:比赛平均跑动距离为5 505±2 048 m,加速和减速距离占比为13.2%和7.5%。平均IMA为483±188次,HIE占比为27%。变向尤其左变向次数显著高于加速和减速次数(P<0.01)。前锋进行爆发式运动的频率最高且每分钟HIE及变向次数显著高于前卫和后卫(P<0.05);后卫每分钟加速次数最高且显著高于前卫(P<0.05)。各PlayerLoad TM均与跑动距离呈极强相关性(r>0.9,P<0.01)并与IMA和HIE次数呈高度相关性(r>0.7,P<0.01),2D PlayerLoad TM与各指标相关程度最高。结论与建议:需加强我国曲棍球运动员整体跑动负荷量及高强度跑动与爆发式运动能力,重点训练变向尤其左变向能力。加强前锋磷酸原系统供能及短距离重复冲刺能力,提高瞬时启动、急停和急转等灵敏能力。加强前卫和后卫的有氧系统供能,提高持续跑动能力。重点训练后卫下肢爆发力,提高瞬时加速进行近身抢断的能力。PlayerLoad TM和2D PlayerLoad TM均可作为集体球类项目跑动距离和爆发式运动的有效替代指标。PlayerLoad TM Slow更适合实时监测速度小于2 m·s-1的爆发式运动,后卫HIE更适合使用PlayerLoad TM Slow进行实时监测。 展开更多
关键词 曲棍球 集体球类项目 ACCELEROMETER GPS IMA PlayerLoadTM
下载PDF
Physical activity after total knee arthroplasty: A critical review 被引量:5
18
作者 Roger J Paxton Edward L Melanson +1 位作者 Jennifer E Stevens-Lapsley Cory L Christiansen 《World Journal of Orthopedics》 2015年第8期614-622,共9页
Total knee arthroplasty(TKA) is the most commonly performed elective surgery in the United States. TKA typically improves functional performance and reduces pain associated with knee osteoarthritis. Little is known ab... Total knee arthroplasty(TKA) is the most commonly performed elective surgery in the United States. TKA typically improves functional performance and reduces pain associated with knee osteoarthritis. Little is known about the influence of TKA on overall physical activity levels. Physical activity, defined as "any bodily movement produced by skeletal muscles that results in energy expenditure", confers many health benefits but typically decreases with endstage osteoarthritis. The purpose of this review is to describe the potential benefits(metabolic, functional, and orthopedic) of physical activity to patients undergoing TKA, present results from recent studies aimed to determine the effect of TKA on physical activity, and discuss potential sources of variability and conflicting results for physical activity outcomes. Several studies utilizing self-reported outcomes indicate that patients perceive themselves to be more physically active after TKA than they were before surgery. Accelerometry-based outcomes indicate that physical activity for patients after TKA remains at or below pre-surgical levels. Several different factors likely contributed to these variable results, including the use of different instruments, duration of follow-up, and characteristics of the subjects studied. Comparison to norms, however, suggests that daily physical activity for patients following TKA may fall short of healthy agematched controls. We propose that further study of the relationship between TKA and physical activity needs to be performed using accelerometry-based outcome measures at multiple post-surgical time points. 展开更多
关键词 PHYSICAL activity KNEE OSTEOARTHRITIS Selfreport TOTAL KNEE ARTHROPLASTY ACCELEROMETER
下载PDF
Structural Design of a Compact in-Plane Nano-Grating Accelerometer 被引量:3
19
作者 姚保寅 周震 +2 位作者 冯丽爽 王文璞 王潇 《Chinese Physics Letters》 SCIE CAS CSCD 2012年第11期219-223,共5页
A combination of large mass,weak spring and nano-grating is the key for a nano-grating accelerometer to measure nano-G acceleration.A novel compact nano-grating accelerometer integrating a large mass with nano-grating... A combination of large mass,weak spring and nano-grating is the key for a nano-grating accelerometer to measure nano-G acceleration.A novel compact nano-grating accelerometer integrating a large mass with nano-grating is proposed.First,the numbers of diffraction orders are calculated.Then,structure parameters are optimized by finite element analysis to achieve a high sensitivity in an ideal vibration mode.Finally,we design the fabrication method to form such a compact nano-grating accelerometer and successfully fabricate the uniform and well-designed nano-gratings with a period of 847 nm,crater of 451 nm by an FIB/SEM dual beam system.Based on the ANSYS simulation,a nano-grating accelerometer is predicted to work in the first modal and enables the accelerometer to have displacement sensitivity at 197 nm/G with a measurement range of±1 G,corresponding to zeroth diffraction beam optical sensitivity 1%/mG.The nano-gratings fabricated are very close to those designed ones within experimental error to lay the foundation for the sequent fabrication.These results provide a theoretical basis for the design and fabrication of nano-grating accelerometers. 展开更多
关键词 ACCELEROMETER BEAM integrating
原文传递
Response to McAvoy and Tudor-Locke on their commentary on our manuscript:“Association of accelerometer-derived step volume and intensity with hospitalizations and mortality in older adults:A prospective cohort study” 被引量:2
20
作者 Asier Mañas Borja del Pozo Cruz +6 位作者 Ulf Ekelund JoséLosa Reyna Irene Rodríguez Gómez JoséAntonio Carnicero Carreño Leocadio Rodríguez Mañas Francisco J.García García Ignacio Ara 《Journal of Sport and Health Science》 SCIE 2022年第6期639-640,共2页
Dear Editor,We have read with interest the commentary by McAvoy and Tudor-Locke on our article entitled "Association of accelerometer-derived step volume and intensity with ho spitalizations and mortality in olde... Dear Editor,We have read with interest the commentary by McAvoy and Tudor-Locke on our article entitled "Association of accelerometer-derived step volume and intensity with ho spitalizations and mortality in older adults:A prospective cohort study". The authors expressed some concerns about our methodology used to define accelerometer-derived step intensity and the analytical approach applied in our study. 展开更多
关键词 ACCELEROMETER prospective MORTALITY
下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部