期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Discussion of the Horizontal Intensity of Late Quaternary Fault Activity Along the Tianjingshan Fault Zone in Different Time Intervals and Fault Segments 被引量:1
1
作者 Chai Chizhang,Zhang Weiqi,and Jiao DechengSeismological Bureau of Ningxia Hui Autonomous Region,Yinchuan 750001,China 《Earthquake Research in China》 1997年第3期25-32,共8页
By computing and classifying the data of gully offset obtained from field surveys along the Tianjingshan fault zone and estimating the ages of three types of gullies,the strike-slip rates along the fault zone are disc... By computing and classifying the data of gully offset obtained from field surveys along the Tianjingshan fault zone and estimating the ages of three types of gullies,the strike-slip rates along the fault zone are discussed in different time intervals and fault segments.The results suggest that the intensity of activity along the fault zone is not strong,but the differences between different time intervals and fault segments since the late Pleistocene have been obvious.The average rates range from 0.23 mm/a to 1.62 mm/a.The largest average rate is 1.40 mm/a,which occurred in the early and middle of late Pleistocene along the western segment of the fault zone.Since the late stage of the late Pleistocene,the center of faulting activity of the fault zone has shifted to the middle segment,and the average slip rates range have changed from 1.30 mm/a to 1.63 mm/a. 展开更多
关键词 Discussion of the Horizontal Intensity of Late Quaternary Fault activity Along the Tianjingshan Fault Zone in Different Time Intervals and Fault Segments activity
下载PDF
Comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping, transcranial Doppler sonography and computer tomography examinations
2
作者 Dongruo He Xiaoying Xu +1 位作者 Yinghui Zhang Guochao Han 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期379-381,共3页
BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to ... BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to severe hypoxic-ischemic encephalopathy (HIE).OBJECTIVE: To observe the abnormal results of HIE at different degrees detected with BEAM and TCD in infant patients, and compare the detection results at the same time point between BEAM, TCD and computer tomography (CT) examinations.DESIGN: Contrast observation.SETTING: Departments of Neuro-electrophysiology and Pediatrics, Second Affiliated Hospital of Qiqihar Medical College.PARTICIPANTS: Totally 416 infant patients with HIE who received treatment in the Department of Newborn Infants, Second Affiliated Hospital of Qiqihar Medical College during January 2001 and December 2005. The infant patients, 278 male and 138 female, were at embryonic 37 to 42 weeks and weighing 2.0 to 4.1 kg, and they were diagnosed with CT and met the diagnostic criteria of HIE of newborn infants compiled by Department of Neonatology, Pediatric Academy, Chinese Medical Association. According to diagnostic criteria, 130 patients were mild abnormal, 196 moderate abnormal and 90 severe abnormal. The relatives of all the infant patients were informed of the experiment. METHODS: BEAM and TCD examinations were performed in the involved 416 infant patients with HIE at different degrees with DYD2000 16-channel BEAM instrument and EME-2000 ultrasonograph before preliminary diagnosis treatment (within 1 month after birth) and 1,3,6,12 and 24 months after birth, and detected results were compared between BEAM, TCD and CT examinations. MAIN OUTCOME MEASURES: Comparison of detection results of HIE at different time points in infant patients between BEAM, TCD and CT examinations.RESULTS: All the 416 infant patients with HIE participated in the result analysis. ① Comparison of the detected results in infant patients with mild HIE at different time points after birth between BEAM, TCD and CT examinations: BEAM examination showed that the recovery was delayed, and the abnormal rate of BEAM examination was significantly higher than that of CT examination 1 and 3 months after birth [55.4%(72/130)vs. 17.0%(22/130),χ2=41.66;29.2%(38/130) vs. 6.2%(8/130),χ2=23.77,P < 0.01], exceptional patients had mild abnormality and reached the normal level in about 6 months. TCD examination showed that the disease condition significantly improved and infant patients with HIE basically recovered 1 or 2 months after birth, while CT examination showed that infant patients recovered 3 or 4 months after birth. ② Comparison of detection results of infant patients with moderate HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination 1,3,6 and 12 months after birth [90.8%(178/196),78.6%(154/196),χ2=4.32,P < 0.05;64.3%(126/196),43.9%(86/196),χ2=16.44;44.9%(88/196),22.4%(44/196),χ2=22.11;21.4%(42/196),10.2%(20/196),χ2=9.27,P < 0.01]. BEAM examination showed that there was still one patient who did not completely recovered in the 24th month due to the relatives of infant patients did not combine the treatment,. TCD examination showed that the abnormal rate was 23.1%(30/196)in the 1st month after birth, and all the patients recovered to the normal in the 3rd month after birth, while CT examination showed that mild abnormality still existed in the 24th month after birth(1.0%,2/196). ③ Comparison of detection results of infant patients with severe HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination in the 1st, 3rd, 6th and 12th months after birth[86.7%(78/90),44.4%(40/90),χ2=35.53;62.2%(56/90),31.1%(28/90),χ2=17.51;37.8%(34/90),6.7%(6/90),χ2=27.14,P < 0.01]. BEAM examination showed that mild abnormality still existed in 4 infant patients in the 24th month after birth. TCD examination showed that the abnormal rate was 11.1% (10/90) in the 3rd month after birth, and all the infant patients recovered in the 6th month after birth. CT examination showed that the abnormal rate was 6.7%(6/90) in the 12th month after birth, and all of infant patients recovered to the normal in the 24th month after birth.CONCLUSION: BEAM is the direct index to detect brain function of infant patients with HIE, and positive reaction is still very sensitive in the tracking detection of convalescent period. The positive rate of morphological reaction in CT examination is superior to that in TCD examination, and the positive rate is very high in the acute period of HIE in examination. 展开更多
关键词 HIE Comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping transcranial Doppler sonography and computer tomography examinations
下载PDF
A six-junction GaAs laser power converter with different sizes of active aperture 被引量:3
3
作者 孙玉润 董建荣 +7 位作者 何洋 赵勇明 于淑珍 薛济萍 薛驰 王瑾 陆云清 丁彦文 《Optoelectronics Letters》 EI 2017年第1期21-24,共4页
We investigate a novel Ga As-based laser power converters(LPCs) grown by metal-organic chemical vapor deposition(MOCVD),which uses a single monolithic structure with six junctions connected by tunnel junctions to obta... We investigate a novel Ga As-based laser power converters(LPCs) grown by metal-organic chemical vapor deposition(MOCVD),which uses a single monolithic structure with six junctions connected by tunnel junctions to obtain a high output voltage. The LPCs with diameters of active aperture of 2 mm and 4 mm were fabricated and tested. The test results show that under an 808 nm laser,two LPCs both show an open circuit voltage of above 6.5 V. A maximum power conversion efficiency of 50.2% is obtained by 2 mm sample with laser power of 0.256 W,and an output electric power of 1.9 W with laser power of 4.85 W is obtained by 4 mm sample. The performances of the LPCs are deteriorated under illumination of high flux,and the 4 mm sample shows a higher laser power tolerance. 展开更多
关键词 Ga A six-junction GaAs laser power converter with different sizes of active aperture As LPC
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部