期刊文献+
共找到7,761篇文章
< 1 2 250 >
每页显示 20 50 100
Influence of Different Vortex Generators on Heat Transfer in Direct Air-Cooled Condensers 被引量:17
1
作者 ZHOU Guobing YANG Laishun 《中国电机工程学报》 EI CSCD 北大核心 2012年第5期I0001-I0020,共20页
通过数值模拟研究了矩形小翼、三角小翼、梯形小翼、柱面梯形翼、柱面三角翼和柱面矩形翼等6种涡流发生器分别安装于直接空冷凝汽器单排蛇形翅片扁管中的压降和换热性能。Re数在600~1800范围内,涡流发生器采用相同高宽比、尾高、攻角以... 通过数值模拟研究了矩形小翼、三角小翼、梯形小翼、柱面梯形翼、柱面三角翼和柱面矩形翼等6种涡流发生器分别安装于直接空冷凝汽器单排蛇形翅片扁管中的压降和换热性能。Re数在600~1800范围内,涡流发生器采用相同高宽比、尾高、攻角以及安装位置。结果表明:矩形小翼的换热及压降增大最多,Re=1729时,相比平直翅片分别增加了14.27%和18.32%。Re=1 729时,柱面梯形翼的压力损失比矩形小翼少4.7%,换热低1.5%。当以(j/j0)/(f/f0)1/3作为综合换热性能评价标准时,柱面梯形翼的综合换热性能最好。另外,考察了柱面梯形翼倾角的影响(0°、6°、12°、20°、24°和26°),相同工况下,倾角为12°的柱面梯形翼换热最好(较平直翅片增强4.29%~14.1%)、压降最小(增大7.5%~12.8%)且综合换热性能最好。柱面梯形翼因其迎流面积与斜边长度的匹配以及流线型柱面,具有良好的强化传热效果以及较小的压降。 展开更多
关键词 直接空冷凝汽器 涡发生器 传热 涡流发生器 风冷冷凝器 空气冷却 化学工业 热交换器
原文传递
Effect of Chromium on CCT Diagrams of Novel Air-Cooled Bainite Steels Analyzed by Neural Network 被引量:4
2
作者 YOU Wei XU Wei-hong +2 位作者 LIU Ya-xiu BAI Bing-zhe FANG Hong-sheng 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2007年第4期39-42,共4页
The quantitative effects of chromium content on continuous cooling transformation(CCT)diagrams of novel air-cooled bainite steels were analyzed using artificial neural network models.The results showed that the chromi... The quantitative effects of chromium content on continuous cooling transformation(CCT)diagrams of novel air-cooled bainite steels were analyzed using artificial neural network models.The results showed that the chromium may retard the high and medium-temperature martensite transformation. 展开更多
关键词 空气冷却 人工神经网络 铬元素 钢铁
下载PDF
Calculation of the Choked Back Pressure for Steam Turbines with Air Cooled Condensers
3
作者 Haisheng Yang Shuping Chang Ruitao Wu 《Energy and Power Engineering》 2013年第4期1474-1477,共4页
The choked back pressure characteristic of the steam turbine unit with air cooled condenser is very different with the unit with wet cooling technology, and the understanding of the choked back pressure performance ch... The choked back pressure characteristic of the steam turbine unit with air cooled condenser is very different with the unit with wet cooling technology, and the understanding of the choked back pressure performance change with operation load is important to guide the economic operation of the unit. One simplified Variable Operation Condition Analysis Method was put forward for calculation of the unit output-turbine back pressure characteristics. Based on this method, the choked back pressure for each operation load can be determined. An example was given for a super-critical, regenerative single-shaft, 2-casing with 2-exhaust steam turbine generation unit with air cooled condenser. The calculation result was provided and compared with the result of the unit with wet cooling technology. 展开更多
关键词 air cooled CONDENSER STEAM TURBINE Choked BACK Pressure CHARACTERISTIC CALCULATION
下载PDF
Physical Properties of Crushed Air-cooled Blast Furnace Slag and Numerical Representation of Its Morphology Characteristics 被引量:1
4
作者 王爱国 邓敏 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第5期973-978,共6页
Physical properties and geometrical morphologies of crushed air-cooled blast furnace slag (SCR) and crushed limestone (LCR) were comparatively investigated. The shape, angularity, surface texture and internal pore str... Physical properties and geometrical morphologies of crushed air-cooled blast furnace slag (SCR) and crushed limestone (LCR) were comparatively investigated. The shape, angularity, surface texture and internal pore structure of aggregate particles for different size and gradation were numerically represented by sphericity (ψ) and shape index (SI), angularity number (AN), index of aggregate particle shape and texture (IAPST), porosity and pore size, respectively. The results show that SCR is a porous and rough aggregate. Apparent density, void, water absorption and smashing index of SCR are obviously higher than those of LCR with the same gradation, respectively. However, bulk density of SCR is lower than that of LCR with the same gradation. SI, AN, IAPST and porosity of SCR are obviously higher than those of LCR with the same gradation, respectively. The smaller particle size of SCR, the larger of its AN, IAPST and porosity. 展开更多
关键词 物理性质 数值表示 形态特征 粉碎 矿渣粉 聚集体颗粒 风冷 形状指数
原文传递
Application of Air-cooled Blast Furnace Slag Aggregates as Replacement of Natural Aggregates in Cement-based Materials:A Study on Water Absorption Property 被引量:1
5
作者 王爱国 liu peng +3 位作者 liu kaiwei li yan zhang gaozhan 孙道胜 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2018年第2期445-451,共7页
The influence of air-cooled blast furnace slag aggregates as replacement of natural aggregates on the water absorption of concrete and mortar was studied, and the mechanism was analyzed. The interface between aggregat... The influence of air-cooled blast furnace slag aggregates as replacement of natural aggregates on the water absorption of concrete and mortar was studied, and the mechanism was analyzed. The interface between aggregate and matrix in concrete was analyzed by using a micro-hardness tester, a laser confocal microscope and a scanning electron microscope with backscattered electron image mode. The pore structure of mortar matrixes under different curing conditions was investigated by mercury intrusion porosimetry. The results showed that when natural aggregates were replaced with air-cooled blast furnace slag aggregates in mortar or concrete, the content of the capillary pore in the mortar matrix was reduced and the interfacial structure between aggregate and matrix was improved, resulting in the lower water absorption of mortar or concrete. Compared to the concrete made with crushed limestone and natural river sand, the initial absorption coefficient, the secondary absorption coefficient and the water absorption capacity through the surface for 7 d of the concrete made from crushed air-cooled blast furnace slag and air-cooled blast furnace slag sand were reduced by 48.9%, 52.8%, and 46.5%, respectively. 展开更多
关键词 空气冷却 水吸收 水泥 炉渣 炉子 强风 扫描电子显微镜 聚集
原文传递
Water, land, and energy use efficiencies and financial evaluation of air conditioner cooled greenhouses based on field experiments
6
作者 Ibtihal AL-MANTHRIA Abdulrahim M AL-ISMAILIA +2 位作者 Hemesiri KOTAGAMAB Mumtaz KHANC L H Janitha JEEWANTHAD 《Journal of Arid Land》 SCIE CSCD 2021年第4期375-387,共13页
High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial asp... High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial aspects of the AC-cooled greenhouse as compared to the evaporative cooled(EV-cooled)greenhouse in winter and summer seasons.Two quonset single-span prototype greenhouses were built in the Agriculture Experiment Station of Sultan Qaboos University,Oman,with dimensions of 6.0 m long and 3.0 m wide.The AC-cooled greenhouse was covered by a rockwool insulated polyethylene plastic sheet and light emitting diodes(LED)lights were used as a source of light,while the EV-cooled greenhouse was covered by a transparent polyethylene sheet and sunlight was used as light source.Three cultivars of high-value lettuce were grown for experimentation.To evaluate the technical efficiency of greenhouse performance,we conducted measures on land use efficiency(LUE),water use efficiency(WUE),gross water use efficiency(GWUE)and energy use efficiency(EUE).Financial analysis was conducted to compare the profitability of both greenhouses.The results showed that the LUE in winter were 10.10 and 14.50 kg/m^(2) for the AC-and EV-cooled greenhouses,respectively.However,the values reduced near to 6.80 kg/m^(2) in both greenhouses in summer.The WUE of the AC-cooled greenhouse was higher than that of the EV-cooled greenhouse by 3.8%in winter and 26.8%in summer.The GWUE was used to measure the total yield to the total greenhouse water consumption including irrigation and cooling water;it was higher in the AC-cooled greenhouse than in the EV-cooled greenhouse in both summer and winter seasons by almost 98.0%–99.4%.The EUE in the EV-cooled greenhouse was higher in both seasons.Financial analysis showed that in winter,gross return,net return and benefit-to-cost ratio were better in the EVcooled greenhouse,while in summer,those were higher in the AC-cooled greenhouse.The values of internal rate of return in the AC-and EV-cooled greenhouses were 63.4%and 129.3%,respectively.In both greenhouses,lettuce investment was highly sensitive to changes in price,yield and energy cost.The financial performance of the AC-cooled greenhouse in summer was better than that of the EV-cooled greenhouse and the pattern was opposite in winter.Finally,more studies on the optimum LED light intensity for any particular crop have to be conducted over different growing seasons in order to enhance the yield quantity and quality of crop. 展开更多
关键词 land use efficiency energy use efficiency water use efficiency gross water use efficiency financial evaluation air conditioner cooled greenhouse evaporative cooled greenhouse
下载PDF
Effects of Using Wind Guiding Nets to Improve Prevailing Ambient Wind on Direct Air-cooled Condensers 被引量:1
7
作者 YANG Jianguo LIU Da ZHANG Zhaoying JU Xiaoli 《中国电机工程学报》 EI CSCD 北大核心 2012年第2期I0001-I0020,共20页
关键词 直接空冷凝汽器 环境风场 风网 入口流量 冷凝器风扇 质量流率 倒灌风 空气
原文传递
Feasibility Analysis of Back-Pressure Steam Feeding Water Pump for Direct Air-Cooled Unit 被引量:1
8
作者 Zhao Xiaodong Wang Meng +2 位作者 Du Xiaoze Yang Lijun Yang Yongping 《Electricity》 2013年第1期31-35,共5页
As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introd... As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introduces a new design of for steam feeding the water pump of an air-cooled unit using the back-pressure steam turbine as the prime motor. Using variable condition analysis on a 600 MW direct air-cooled unit, and with consideration of the effect on the ambient conditions, the feasibility, economy, and adaptability of the design are verified. 展开更多
关键词 直接空冷机组 给水泵 蒸汽 背压 风冷式冷凝器 变工况分析 空气冷却 汽轮机
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
9
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
城市化进程的加快意味着城市和国际组织需要去寻找各种能够提高能源效率和减少空气中污染物排放的方法。冷热电联产(CCHP)系统可以同时供暖、制冷和发电,具有提高城市或城市区域能源发电效率的潜力。本研究的目的是在满足建筑热需求(供... 城市化进程的加快意味着城市和国际组织需要去寻找各种能够提高能源效率和减少空气中污染物排放的方法。冷热电联产(CCHP)系统可以同时供暖、制冷和发电,具有提高城市或城市区域能源发电效率的潜力。本研究的目的是在满足建筑热需求(供热和制冷)的各种运行条件下,对亚特兰大大都市区内的五种常见建筑类型在采用CCHP系统时的发电耗水、CO_2和NO_x排放,及其经济性进行评价。对于大多数采用或不采用净计量策略的建筑类型来说,以满足每小时热需求去运行CCHP系统均可减少CO_2的排放量。该系统能否对这些建筑类型产生经济效益,主要取决于天然气的价格、净计量策略的采用和假定的CCHP系统的成本结构。当建筑物采用净计量策略并且CCHP系统是以满足建筑物每年的最大热需求而运行时,CCHP系统的发电耗水量和NO_x的排放量均有最大限度的减少,尽管此时该运行情景会增加温室气体排放和发电成本。CCHP系统对中型办公楼、大型办公楼和多户型住宅建筑更经济、实用。 展开更多
关键词 电力系统 空气冷却 供热成本 亚特兰大 微型燃气轮机 空气污染 冷热电联供系统 二氧化碳排放
下载PDF
Numerical Simulation of Thermal Management of Lithium Battery Based on Air Cooled Heat Dissipation
10
作者 Zhenhua Li 《Journal of Electronic & Information Systems》 2022年第1期18-25,共8页
In recent years,due to the rapid increase in the number of vehicles in the world,the traditional vehicles using gasoline or diesel as energy have led to serious air pollution and energy depletion.It is urgent to devel... In recent years,due to the rapid increase in the number of vehicles in the world,the traditional vehicles using gasoline or diesel as energy have led to serious air pollution and energy depletion.It is urgent to develop practical clean energy vehicles.The performance of electric vehicle depends on the power battery pack.The working temperature of the battery pack has a great impact on the performance of the battery,so it is necessary to carry out thermal management on the battery pack.Taking a lithium-ion battery as the research object,the temperature field of the battery pack in the charge and discharge state is simulated and analyzed by using CFD simulation software in the way of air cooled heat dissipation,so as to understand the influencing factors of uneven temperature field.At the same time,the development trend of battery temperature can be well predicted through simulation,so as to provide theoretical basis for the design of battery pack. 展开更多
关键词 Lithium ion battery pack air cooled heat dissipation Temperature field CFD
下载PDF
Effect of Crushed Air-cooled Blast Furnace Slag on Mechanical Properties of Concrete
11
作者 王爱国 邓敏 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第4期758-762,共5页
Morphology characteristics of mix aggregates with crushed air-cooled blast furnace slag(SCR) and crushed limestone(LCR) with 5-20 mm and 20-40 mm gradation were represented by numerical parameters including angularity... Morphology characteristics of mix aggregates with crushed air-cooled blast furnace slag(SCR) and crushed limestone(LCR) with 5-20 mm and 20-40 mm gradation were represented by numerical parameters including angularity number(AN) and index of aggregate particle shape and texture(IAPST).The effect of mix aggregates containing SCR on compressive strength and splitting tensile strength of concrete was investigated.Fracture characteristics of concrete,interfacial structure between aggregates and matrix were analyzed.The experimental results show that porous and rough SCR increases contact area with matrix in concrete,concave holes and micro-pores on the surface of SCR are filled by mortar and hydrated cement paste,which may increase interlocking and mechanical bond between aggregate and matrix in concrete.SCR can be used to produce a high-strength concrete with better mechanical properties than corresponding concrete made with LCR.The increase of AN and IAPST of aggregate may enhance mechanical properties of concrete. 展开更多
关键词 矿渣混凝土 高炉矿渣 力学性能 粉碎 风冷 劈裂抗拉强度 高强度混凝土 机械性能
原文传递
Quantitative analysis of Ni effect on CCT diagrams of novel air-cooled bainite steels using artificial neural network models
12
作者 Weihong Xu Wei You +2 位作者 Yaxiu Liu Bingzhe Bai Hongsheng Fang 《Journal of University of Science and Technology Beijing》 CSCD 2005年第5期410-415,共6页
The quantitative effect of Ni content on continuous cooling transformation (CCT) diagrams of novel air-cooled bainite steels was analyzed using artificial neural network models. The results showed that Ni may retard t... The quantitative effect of Ni content on continuous cooling transformation (CCT) diagrams of novel air-cooled bainite steels was analyzed using artificial neural network models. The results showed that Ni may retard the high- and medium-temperature transformation and martensite transformation. The results conform to the materials science theories. 展开更多
关键词 空气冷却贝氏体钢 镍含量 CCT图表 人工神经网络 合金钢
下载PDF
Thermodynamic Simulation of CCP in Air-Cooled Heat Pump Unit with HFCs and CO<sub>2</sub>Trans-Critical 被引量:1
13
作者 Feihu Chen Shuguang Liao Guangcai Gong 《Journal of Power and Energy Engineering》 2018年第9期141-164,共24页
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ... The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2. 展开更多
关键词 air-cooled Heat Pump Unit Compound Condensation Process (CCP) EXERGY Analysis Method Sanitary Hot Water MATLAB/SIMULINK Software Fluorine Substitute REFRIGERANT R407C/R410A Natural REFRIGERANT CO2
下载PDF
The Experimental Investigation of Recirculation of Air-Cooled System for a Large Power Plant
14
作者 Wanli Zhao Qiyue Wang Peiqing Liu 《Energy and Power Engineering》 2010年第4期291-297,共7页
The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV... The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV experiments are carried out and recirculation ratio of each condition is calculated. Results show that the thermal flow field of the cooling tower has great influence on the recirculation under the cooling tower. Ameliorating the thermal flow field of the cooling tower can reduce the recirculation under the cooling tower and improve the efficiency of air-cooled condenser also. 展开更多
关键词 DIRECT air-cooled CONDENSER Thermal Flow Field Recirculation PIV EXPERIMENT Power PLANT
下载PDF
Influence of thermal flow field of cooling tower on recirculation ratio of a direct air-cooled system for a power plant
15
作者 Zhao Wanli Liu Peiqing 《Engineering Sciences》 EI 2008年第4期64-70,共7页
In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get the... In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get thermal flow field of a ACC under different conditions in low velocity wind tunnel,at the same time,the recirculation ratio at cooling tower was measured,so the relationship between flow field characteristics and recirculation ratio of cooling tower can be discussed. From the results we can see that the flow field configuration around cooling tower has great effects on average recirculation ratio under cooling tower. The eddy formed around cooling tower is a key reason that recirculation produces. The eddy intensity relates to velocity magnitude and direction angle,and the configuration of eddy lies on the geometry size of cooling tower. So changing the flow field configuration around cooling tower reasonably can decrease recirculation ratio under cooling tower,and heat dispel effect of ACC can also be improved. 展开更多
关键词 直接空冷系统 冷却塔 流量场 再循环 电厂 比例 流场特性 冷却冷凝器
下载PDF
Experimental Study on Riprap Air-Cooled Roadbed of Qinghai-Tibet Railway
16
作者 Li Ning Wei Qingchao Wei Jing 《工程科学(英文版)》 2006年第2期98-107,共10页
The riprap air-cooled roadbed and common roadbed experimental project were designed and carried on in Qingshuihe test filed, an area of warm permafrost category with the fine frozen soil along Qinghai-Tibet Railway, t... The riprap air-cooled roadbed and common roadbed experimental project were designed and carried on in Qingshuihe test filed, an area of warm permafrost category with the fine frozen soil along Qinghai-Tibet Railway, to decide the temperature field of the roadbed after railway construction. Based on ground temperature variation of natural hole, left and right shoulder’s hole, the maximum thawing depth, and the deformation in these two kinds of roadbed were analysed comparatively. It showed that the riprap air-cooled roadbed had better effect of lowering ground temperature, lifting the maximum frozen-thawing depth obviously and decreasing deformation than that of the common roadbed. Therefore, the riprap air-cooled roadbed was a positive frozen soil protection measure for it effectively decreased ground temperature and protected permafrost. 展开更多
关键词 青藏铁路 乱石基 空气冷却 路基变形
下载PDF
云南冬季强降温过程冷空气路径及大气环流差异
17
作者 姚愚 晏红明 《云南大学学报(自然科学版)》 CAS CSCD 北大核心 2024年第1期94-105,共12页
基于云南125个测站日平均气温数据,判定了1961—2020年云南冬季95次强降温过程的4种冷空气路径,对比分析了不同路径冷空气对云南降温的影响及大气环流差异.结果表明,东北路径冷空气对云南降温幅度影响最剧烈、影响空间范围最广;偏东路... 基于云南125个测站日平均气温数据,判定了1961—2020年云南冬季95次强降温过程的4种冷空气路径,对比分析了不同路径冷空气对云南降温的影响及大气环流差异.结果表明,东北路径冷空气对云南降温幅度影响最剧烈、影响空间范围最广;偏东路径出现频率最高,偏东路径和偏北路径在降温幅度和影响范围上较为接近;东南路径降温幅度和影响范围最弱,出现频率最低.超前强降温日2 d时,东北路径欧亚大陆500 hPa位势高度场上正高度距平异常区域强度和面积、700 hPa反气旋距平环流强度和西伯利亚高压均为最强,东南路径最弱,偏东路径和偏北路径介于前二者之间.东北路径500 hPa上东亚槽横槽转竖特征最明显,偏东路径和偏北路径东亚槽槽底南压加深,但转竖特征不及东北路径明显;东南路径东亚槽底部较宽广;东北路径副高呈块状面积最小,其它3种路径副高则呈带状,偏东路径副高面积最大.700 hPa上东北路径和偏东路径在日本附近有较强海平面气压负距平发展,朝鲜半岛气旋距平环流较强,其西侧较强的偏北气流引导冷空气进入云南;东南路径和偏北路径在朝鲜半岛气旋距平环流及其西侧的偏北气流较弱.在200 hPa纬向风距平场上,东北路径急流轴附近正负距平区强度最强,偏东路径沿急流轴距平分布为西正东负;东南路径正负距平区强度最弱,负距平区主要分布在急流轴北侧,偏北路径负距平区分布在急流轴南北两侧. 展开更多
关键词 云南 冬季 强降温过程 冷空气路径 环流差异
下载PDF
汽轮发电机带有交替径向风道的转子流体与传热耦合分析
18
作者 李伟力 乔田怀 +3 位作者 李亚磊 李程昊 刘明洋 李志强 《电机与控制学报》 EI CSCD 北大核心 2024年第2期11-20,共10页
针对汽轮发电机带有交替径向通风道的转子发热冷却问题,以一台350 MW水氢氢冷汽轮发电机为研究对象,依据流体力学和传热学的基本理论,首先建立计及旋转的电机全域通风网络模型,采用逐次迭代法计算得到各支路流量和节点压力。其次,建立... 针对汽轮发电机带有交替径向通风道的转子发热冷却问题,以一台350 MW水氢氢冷汽轮发电机为研究对象,依据流体力学和传热学的基本理论,首先建立计及旋转的电机全域通风网络模型,采用逐次迭代法计算得到各支路流量和节点压力。其次,建立了带有交替径向风道的发电机转子流体-传热三维物理模型和数学模型,给出了基本假设和相应的边界条件,同时将通风网络计算得到的风速和压力作为转子求解域的耦合边界,采用有限体积法进行求解,计算结果与实测值吻合。然后分析了交替径向风道内流量分配和氢气流动情况,研究了转子内部氢气温度分布和槽楔出风口风温变化规律,探明了转子绕组和铁心轴向温度分布特性,讨论了副槽入口流量和槽楔出口直径对转子流体和温度的影响。得出副槽入口流量应控制在0.1~0.16 m^(3)/s范围内,且选择较小的槽楔出口直径,可以提高通风系统的效率与风量分配均匀性,降低转子轴向热不平衡。 展开更多
关键词 水氢氢冷汽轮发电机 交替径向风道 通风网络 流体流动与传热 有限体积法
下载PDF
数据中心冷却系统研究及应用进展
19
作者 周峰 谷文龙 +1 位作者 马国远 晏祥慧 《制冷与空调》 2024年第2期63-71,共9页
为加速实现数据中心节能降耗的目标,在合理、高效、最大化地利用自然冷源的同时,更不能忽视机械制冷系统本身能效的提升。加强自然冷却与机械制冷的协同,降低数据中心PUE,充分发挥安全稳定、高效运行的数据中心冷却系统自身能效至关重... 为加速实现数据中心节能降耗的目标,在合理、高效、最大化地利用自然冷源的同时,更不能忽视机械制冷系统本身能效的提升。加强自然冷却与机械制冷的协同,降低数据中心PUE,充分发挥安全稳定、高效运行的数据中心冷却系统自身能效至关重要。本文通过对气流组织、供/回水温度和冷却系统部件及形式3个方面的研究梳理,总结分析数据中心冷却系统节能提效有关技术研究与应用进展,从而为绿色、高效数据中心冷却系统的研发提供参考和借鉴。 展开更多
关键词 数据中心 冷却系统 气流组织 供回水温度 部件及形式
下载PDF
增材制造中空风冷板工艺设计与试验
20
作者 罗锡 刘骁 李珊 《机械研究与应用》 2024年第1期51-54,共4页
为了验证增材制造技术对复杂中空风冷板的可行性,对中空风冷板模型增材制造工艺性、增材制造打印成型工艺性和粉末选择进行了分析对比。文中优选成熟AlSi10Mg铝合金打印参数完成中空风冷板的成型,并对随炉打印的试样力学性能和表面处理... 为了验证增材制造技术对复杂中空风冷板的可行性,对中空风冷板模型增材制造工艺性、增材制造打印成型工艺性和粉末选择进行了分析对比。文中优选成熟AlSi10Mg铝合金打印参数完成中空风冷板的成型,并对随炉打印的试样力学性能和表面处理防护性能进行了试验验证。试验结果表明,增材中空风冷板性能可以满足产品设计使用要求。 展开更多
关键词 中空风冷板 增材制造 成型方向 力学性能 防护性能
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部