Based on the corresponding theories of engineering thermodynamics and hydro-dynamics, a careful study is made of the characteristics of air flow in different duct-embedded ways. According to critical Reynolds number, ...Based on the corresponding theories of engineering thermodynamics and hydro-dynamics, a careful study is made of the characteristics of air flow in different duct-embedded ways. According to critical Reynolds number, the atmospheric critical velocity of the duct with different diameters, which makes laminar flow different from turbulent flow, is calculated. Given the condition in which a forced flow occurs and the wind strength is larger than the atmospheric pressure gradient along the air-duct, a rational ratio of the length to the diameter is presented. Based on the above theory and field test data on soil temperature and embankment settlement, the advantages and disadvantages are discussed in details of all duct-embedded ways that might affect the stability of embankment.展开更多
Heating-only fan coil(HFC)is one of the suited end users,which is not only compact but also highly efficient.And the major factors affecting the heat dissipation performance of HFC include leakage through coil bypass,...Heating-only fan coil(HFC)is one of the suited end users,which is not only compact but also highly efficient.And the major factors affecting the heat dissipation performance of HFC include leakage through coil bypass,distance between fan and coil,fan structure and air inlet type.Under natural air convection or forced,experimental studies were made on the effects of these factors upon the heat dissipation performance of HFC.The results show that:1)After reducing the leakage through coil bypass,the heat dissipation of HFC increases 16.9% under natural convection,and increases 8.3% under forced convection.2)After the distance between fan and coil be raised from 23.2cm to 41.7cm,the heat dissipation of HFC decreases 21.3% under natural convection,but increases12.8% under forced convection.3)After changing the fan structure,the heat dissipation of HFC increases 41.8% under natural convection,and the heat dissipation per motor power increases 96.1% under forced convection.4)The heat dissipations of HFC with round pass,slit and strip type of air inlet are different,whose proportion is about 100%,110%,136% under natural convection,and 100%,105%,116% under forced convection.展开更多
The samples cut from U75V 60 kg/m heavy rail are heated to 900 ℃ in resistance furnace and then put into air spraying channel to be cooled for 80 s, and change air pressure from 0.16 MPa to 0.33 MPa, and observe the ...The samples cut from U75V 60 kg/m heavy rail are heated to 900 ℃ in resistance furnace and then put into air spraying channel to be cooled for 80 s, and change air pressure from 0.16 MPa to 0.33 MPa, and observe the effect of air pressure on hardened layer. The thickness and hardness of hardened layer increases with the increase of air pressure, and the thickness is more than 24 mm at the center and top fillets of rail head, and more than 15 mm at the blow fillets of rail head when air pressure is more than 0.26 MPa. During the tempering after heat treatment, tempering temperature of rail head is more than 570 ℃ when air pressure is separately 0.16 MPa, 0.20 MPa and 0.23 MPa, which is higher than finishing temperature of pearlite transformation at the cooling rate of 3 ℃/s according to CCT curve of U75V steel. When air pressure is separately 0.26, 0.30 and 0.33 MPa, the tempering temperature is 529 ℃ lower than finishing temperature of pearlite transformation at the cooling rate of 3 ℃/s. Under this condition, pearlite transformation is finished totally, so in order to reduce air consumption and control the cost, proper air pressure for U75V 60 kg/m heavy rail heat treating should be 0.26 MPa; the cooling rate increases with the increase of air pressure, and the average cooling rate on the surface of rail head is more than 3.21 ℃/s when air pressure is more than 0.26 MPa, and the largest cooling rate occurs at the top fillets of rail head.展开更多
The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was u...The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was used to predict the system performance and zone air temperature of two kinds of layouts that were applied to a typical floor of an existing building office in Hong Kong. The position where the static pressure sensor was placed should affect the zones temperature and energy consumption. The comparison of predictions of the two kinds of layouts indicates that with the same DSPR control method the layout of the air duct might influence the fan control result and energy savings.展开更多
Air in the main pancreatic duct has been reported only rarely and might be associated with either a spontane- ous or a surgically induced alteration of the anatomy of the biliary tract. We report a case of "innocent...Air in the main pancreatic duct has been reported only rarely and might be associated with either a spontane- ous or a surgically induced alteration of the anatomy of the biliary tract. We report a case of "innocent" air found incidentally in the main pancreatic duct. To our knowledge, this is only the third such case reported. A 54-year-old woman presented with hemoptysis that had lasted for 3 d. She underwent a chest computed tomography scan, which revealed not only focal bron- chiectasis in the left lower lobe, but also air in the main pancreatic duct and dilatation of the common bile duct. She was managed conservatively for the hemop- blsis and no further problems developed. She had no specific gastrointestinal symptoms and had no history of surgery or medication. Her laboratory parameters were normal. Magnetic resonance cholangiopancrea- tography also demonstrated air in the main pancreatic duct and a dilated common bile duct (CBD). Duode- noscopy revealed separate biliary and pancreatic ori-rices with patulous openings and some air bubbles ap- pearing in the pancreatic orifice. Endoscopic retrograde cholangiopancreatography (ERCP) showed the dilated CBD and pancreatic duct with some air bubbles, but no other abnormal lesions. She was discharged with no further problems. Most patients with air in the main pancreatic duct have had a pancreatobiliary disease, or a history of pancreatobiliary disease, pancreatobiliary surgery or sphincterotomy. If the air is innocent, as in our case, ERCP should be performed to evaluate any altered sphincteric function or anatomy such as patu- Ious openings.展开更多
Bleed air system is one of the most important components of air management system(AMS).It acts as transfer pipes responsible for air supply at high temperature and pressure.The thermal and flow performance of the blee...Bleed air system is one of the most important components of air management system(AMS).It acts as transfer pipes responsible for air supply at high temperature and pressure.The thermal and flow performance of the bleed air system is a key issue for the design of AMS since the characteristics of air source have a great influence on the anti-ice system,the environmental control system and other downstream system in need of high temperature pressurized air.Based on the one-dimensional lumped parameter technology,a computer analysis model of bleed air system is developed in order to analyze the thermal and flow behaviors of the nodal points in the pipeline network.The simulation are performed with a given flight assignment using the analysis model,and the results verify that the system meets the design requirements.展开更多
Applying the air impact molding method to mold the complicated pattern with wider opening surface and deeper concave, there always exist vaulted phenomenon and lower compactibility of sand mold over the entrance and t...Applying the air impact molding method to mold the complicated pattern with wider opening surface and deeper concave, there always exist vaulted phenomenon and lower compactibility of sand mold over the entrance and the concave regions. Using the air-stream and synchro-formed clamp plate impact molding, however, this problem will be preferably solved. In this paper, the compact mechanism of the new molding method and the effect of some configuration factors, such as the area flowed by compressed air and the highness of the protruding block displacement around the diffluent clamp plate, on the compactibility of sand mold were discussed.展开更多
Temperature is critical to maintaining seed viability under long-term storage conditions. It has been common practice to use refrigeration systems to maintain required storage temperatures. A seed repository construct...Temperature is critical to maintaining seed viability under long-term storage conditions. It has been common practice to use refrigeration systems to maintain required storage temperatures. A seed repository constructed in permafrost in Yakutsk, Russia is the first seed storage facility that relies solely on natural cold. This paper describes the design and performance of the cooling system of the repository. An innovative aspect of the cooling system is that it utilizes the patterns of temperature wave propagation in permafrost. Predicted and measured ground temperatures for the first year of operation are presented and analyzed. Results indicate that convection air cooling systems can be used to control the temperature regime in underground facilities in permafrost.展开更多
After the completion of Beijing New Airport, air-rail intermodality will become an important means of internal and external links in Jing-Jin-Ji Region. Jing-Jin-Ji Air-Rail Intermodality System is built and 7 sub-sys...After the completion of Beijing New Airport, air-rail intermodality will become an important means of internal and external links in Jing-Jin-Ji Region. Jing-Jin-Ji Air-Rail Intermodality System is built and 7 sub-systems are divided based on user demand analysis. Refer to the passenger process, the business process of the system is planned and the sub-systems are described using data flow diagram. The system provides theoretical support for the development of air-rail intermodal in Jing-Jin-Ji region.展开更多
The high-speed rail(HSR)network in China has experienced rapid development since the 2000s.In 2016,the State Council of the People’s Republic of China issued a revised version of the“Mid-and Long-term Railway Networ...The high-speed rail(HSR)network in China has experienced rapid development since the 2000s.In 2016,the State Council of the People’s Republic of China issued a revised version of the“Mid-and Long-term Railway Network Plan”,detailing the expansion of the railway network and construction of an HSR system.In the future,the HSR construction efforts in China will further increase,which is considered to impact regional development and air pollutant emissions.Therefore,in this paper,we apply a transportation network-multiregional computable general equilibrium(CGE)model to estimate the dynamic effects of HSR projects on economic growth,regional disparities,and air pollutant emissions in China.The results indicate that HSR system improvement could generate a positive economic impact but could also increase emissions.The gross domestic product(GDP)growth per unit investment cost stimulated by HSR investment is found to be the largest in eastern China but the smallest in the northwest regions.Conversely,HSR investment in Northwest China contributes to a substantial reduction in regional disparities in terms of the GDP per capita.In regard to air pollution emissions,HSR construction in South-Central China results in the largest increase in CO_(2) and NO_(X) emissions,while for CO,SO_(2),and fine particulate matter(PM_(2.5))emissions,the largest increase occurs due to HSR construction in Northwest China.At the regional level,the provinces with large changes in accessibility also experience large changes in their air pollutant emissions.展开更多
This paper deals with the mechanism of fibre deposition in OE friction spinning.A fibremodel has been established to analize and evaluate fibre.straightness after deposition.Exper-iments have been done on the measurem...This paper deals with the mechanism of fibre deposition in OE friction spinning.A fibremodel has been established to analize and evaluate fibre.straightness after deposition.Exper-iments have been done on the measurement of air flow speed at the entrance and exit of thefeed duct which is mounted in an experimental friction spinning unit.Conclusion has beendrawn:the weakness of friction spun yarn is mainly due to its poor fibre straigthness after dep-osition.展开更多
This paper expounds the concept of HVAC construction,specifically analyzes the current situation of HVAC construction in construction engineering,and focuses on the key and difficult points in HVAC construction.In ord...This paper expounds the concept of HVAC construction,specifically analyzes the current situation of HVAC construction in construction engineering,and focuses on the key and difficult points in HVAC construction.In order to provide an effective reference for improving the quality of HVAC construction in the current construction engineering,some suggestions are put forward for improvement of relevant technologies involved in key and difficult points.展开更多
文摘Based on the corresponding theories of engineering thermodynamics and hydro-dynamics, a careful study is made of the characteristics of air flow in different duct-embedded ways. According to critical Reynolds number, the atmospheric critical velocity of the duct with different diameters, which makes laminar flow different from turbulent flow, is calculated. Given the condition in which a forced flow occurs and the wind strength is larger than the atmospheric pressure gradient along the air-duct, a rational ratio of the length to the diameter is presented. Based on the above theory and field test data on soil temperature and embankment settlement, the advantages and disadvantages are discussed in details of all duct-embedded ways that might affect the stability of embankment.
基金Supported by National11th Five-Year Plan Major Scientific and Technological Issues of China(2006BAJ01A04)
文摘Heating-only fan coil(HFC)is one of the suited end users,which is not only compact but also highly efficient.And the major factors affecting the heat dissipation performance of HFC include leakage through coil bypass,distance between fan and coil,fan structure and air inlet type.Under natural air convection or forced,experimental studies were made on the effects of these factors upon the heat dissipation performance of HFC.The results show that:1)After reducing the leakage through coil bypass,the heat dissipation of HFC increases 16.9% under natural convection,and increases 8.3% under forced convection.2)After the distance between fan and coil be raised from 23.2cm to 41.7cm,the heat dissipation of HFC decreases 21.3% under natural convection,but increases12.8% under forced convection.3)After changing the fan structure,the heat dissipation of HFC increases 41.8% under natural convection,and the heat dissipation per motor power increases 96.1% under forced convection.4)The heat dissipations of HFC with round pass,slit and strip type of air inlet are different,whose proportion is about 100%,110%,136% under natural convection,and 100%,105%,116% under forced convection.
基金Sponsored by the National Key Technologies Research and Development Program(Grant No.2004BA317B-4-1)
文摘The samples cut from U75V 60 kg/m heavy rail are heated to 900 ℃ in resistance furnace and then put into air spraying channel to be cooled for 80 s, and change air pressure from 0.16 MPa to 0.33 MPa, and observe the effect of air pressure on hardened layer. The thickness and hardness of hardened layer increases with the increase of air pressure, and the thickness is more than 24 mm at the center and top fillets of rail head, and more than 15 mm at the blow fillets of rail head when air pressure is more than 0.26 MPa. During the tempering after heat treatment, tempering temperature of rail head is more than 570 ℃ when air pressure is separately 0.16 MPa, 0.20 MPa and 0.23 MPa, which is higher than finishing temperature of pearlite transformation at the cooling rate of 3 ℃/s according to CCT curve of U75V steel. When air pressure is separately 0.26, 0.30 and 0.33 MPa, the tempering temperature is 529 ℃ lower than finishing temperature of pearlite transformation at the cooling rate of 3 ℃/s. Under this condition, pearlite transformation is finished totally, so in order to reduce air consumption and control the cost, proper air pressure for U75V 60 kg/m heavy rail heat treating should be 0.26 MPa; the cooling rate increases with the increase of air pressure, and the average cooling rate on the surface of rail head is more than 3.21 ℃/s when air pressure is more than 0.26 MPa, and the largest cooling rate occurs at the top fillets of rail head.
文摘The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was used to predict the system performance and zone air temperature of two kinds of layouts that were applied to a typical floor of an existing building office in Hong Kong. The position where the static pressure sensor was placed should affect the zones temperature and energy consumption. The comparison of predictions of the two kinds of layouts indicates that with the same DSPR control method the layout of the air duct might influence the fan control result and energy savings.
文摘Air in the main pancreatic duct has been reported only rarely and might be associated with either a spontane- ous or a surgically induced alteration of the anatomy of the biliary tract. We report a case of "innocent" air found incidentally in the main pancreatic duct. To our knowledge, this is only the third such case reported. A 54-year-old woman presented with hemoptysis that had lasted for 3 d. She underwent a chest computed tomography scan, which revealed not only focal bron- chiectasis in the left lower lobe, but also air in the main pancreatic duct and dilatation of the common bile duct. She was managed conservatively for the hemop- blsis and no further problems developed. She had no specific gastrointestinal symptoms and had no history of surgery or medication. Her laboratory parameters were normal. Magnetic resonance cholangiopancrea- tography also demonstrated air in the main pancreatic duct and a dilated common bile duct (CBD). Duode- noscopy revealed separate biliary and pancreatic ori-rices with patulous openings and some air bubbles ap- pearing in the pancreatic orifice. Endoscopic retrograde cholangiopancreatography (ERCP) showed the dilated CBD and pancreatic duct with some air bubbles, but no other abnormal lesions. She was discharged with no further problems. Most patients with air in the main pancreatic duct have had a pancreatobiliary disease, or a history of pancreatobiliary disease, pancreatobiliary surgery or sphincterotomy. If the air is innocent, as in our case, ERCP should be performed to evaluate any altered sphincteric function or anatomy such as patu- Ious openings.
文摘Bleed air system is one of the most important components of air management system(AMS).It acts as transfer pipes responsible for air supply at high temperature and pressure.The thermal and flow performance of the bleed air system is a key issue for the design of AMS since the characteristics of air source have a great influence on the anti-ice system,the environmental control system and other downstream system in need of high temperature pressurized air.Based on the one-dimensional lumped parameter technology,a computer analysis model of bleed air system is developed in order to analyze the thermal and flow behaviors of the nodal points in the pipeline network.The simulation are performed with a given flight assignment using the analysis model,and the results verify that the system meets the design requirements.
文摘Applying the air impact molding method to mold the complicated pattern with wider opening surface and deeper concave, there always exist vaulted phenomenon and lower compactibility of sand mold over the entrance and the concave regions. Using the air-stream and synchro-formed clamp plate impact molding, however, this problem will be preferably solved. In this paper, the compact mechanism of the new molding method and the effect of some configuration factors, such as the area flowed by compressed air and the highness of the protruding block displacement around the diffluent clamp plate, on the compactibility of sand mold were discussed.
文摘Temperature is critical to maintaining seed viability under long-term storage conditions. It has been common practice to use refrigeration systems to maintain required storage temperatures. A seed repository constructed in permafrost in Yakutsk, Russia is the first seed storage facility that relies solely on natural cold. This paper describes the design and performance of the cooling system of the repository. An innovative aspect of the cooling system is that it utilizes the patterns of temperature wave propagation in permafrost. Predicted and measured ground temperatures for the first year of operation are presented and analyzed. Results indicate that convection air cooling systems can be used to control the temperature regime in underground facilities in permafrost.
文摘After the completion of Beijing New Airport, air-rail intermodality will become an important means of internal and external links in Jing-Jin-Ji Region. Jing-Jin-Ji Air-Rail Intermodality System is built and 7 sub-systems are divided based on user demand analysis. Refer to the passenger process, the business process of the system is planned and the sub-systems are described using data flow diagram. The system provides theoretical support for the development of air-rail intermodal in Jing-Jin-Ji region.
基金supported by funding from the National Natural Science Foundation of China(Nos.41821005 and 42077196).
文摘The high-speed rail(HSR)network in China has experienced rapid development since the 2000s.In 2016,the State Council of the People’s Republic of China issued a revised version of the“Mid-and Long-term Railway Network Plan”,detailing the expansion of the railway network and construction of an HSR system.In the future,the HSR construction efforts in China will further increase,which is considered to impact regional development and air pollutant emissions.Therefore,in this paper,we apply a transportation network-multiregional computable general equilibrium(CGE)model to estimate the dynamic effects of HSR projects on economic growth,regional disparities,and air pollutant emissions in China.The results indicate that HSR system improvement could generate a positive economic impact but could also increase emissions.The gross domestic product(GDP)growth per unit investment cost stimulated by HSR investment is found to be the largest in eastern China but the smallest in the northwest regions.Conversely,HSR investment in Northwest China contributes to a substantial reduction in regional disparities in terms of the GDP per capita.In regard to air pollution emissions,HSR construction in South-Central China results in the largest increase in CO_(2) and NO_(X) emissions,while for CO,SO_(2),and fine particulate matter(PM_(2.5))emissions,the largest increase occurs due to HSR construction in Northwest China.At the regional level,the provinces with large changes in accessibility also experience large changes in their air pollutant emissions.
文摘This paper deals with the mechanism of fibre deposition in OE friction spinning.A fibremodel has been established to analize and evaluate fibre.straightness after deposition.Exper-iments have been done on the measurement of air flow speed at the entrance and exit of thefeed duct which is mounted in an experimental friction spinning unit.Conclusion has beendrawn:the weakness of friction spun yarn is mainly due to its poor fibre straigthness after dep-osition.
文摘This paper expounds the concept of HVAC construction,specifically analyzes the current situation of HVAC construction in construction engineering,and focuses on the key and difficult points in HVAC construction.In order to provide an effective reference for improving the quality of HVAC construction in the current construction engineering,some suggestions are put forward for improvement of relevant technologies involved in key and difficult points.