期刊文献+
共找到1,589篇文章
< 1 2 80 >
每页显示 20 50 100
Alternating current heating techniques for lithium-ion batteries in electric vehicles:Recent advances and perspectives
1
作者 Xinrong Huang Jinhao Meng +5 位作者 Wei Jiang Wenjie Liu Kailong Liu Yipu Zhang Daniel-Ioan Stroe Remus Teodorescu 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第9期679-697,共19页
The significant decrease in battery performance at low temperatures is one of the critical challenges that electric vehicles(EVs)face,thereby affecting the penetration rate in cold regions.Alternating current(AC)heati... The significant decrease in battery performance at low temperatures is one of the critical challenges that electric vehicles(EVs)face,thereby affecting the penetration rate in cold regions.Alternating current(AC)heating has attracted widespread attention due to its low energy consumption and uniform heating advantages.This paper introduces the recent advances in AC heating from the perspective of practical EV applications.First,the performance degradation of EVs in low-temperature environments is introduced briefly.The concept of AC heating and its research methods are provided.Then,the effects of various AC heating methods on battery heating performance are reviewed.Based on existing studies,the main factors that affect AC heating performance are analyzed.Moreover,various heating circuits based on EVs are categorized,and their cost,size,complexity,efficiency,reliability,and heating rate are elaborated and compared.The evolution of AC heaters is presented,and the heaters used in brand vehicles are sorted out.Finally,the perspectives and challenges of AC heating are discussed.This paper can guide the selection of heater implementation methods and the optimization of heating effects for future EV applications. 展开更多
关键词 Lithium-ion battery Low temperature alternating current heating HEATER Electric vehicle
下载PDF
Effects of alternating current interference on corrosion of X60 pipeline steel 被引量:9
2
作者 Yan-Bao Guo Cheng Liu +1 位作者 De-Guo Wang Shu-Hai Liu 《Petroleum Science》 SCIE CAS CSCD 2015年第2期316-324,共9页
With rapid economic development in China, demand for energy and transportation is growing. Due to the limitations of factors such as terrain and traffic, a large number of buried oil and gas pipelines are parallel to ... With rapid economic development in China, demand for energy and transportation is growing. Due to the limitations of factors such as terrain and traffic, a large number of buried oil and gas pipelines are parallel to high- voltage transmission lines and electrified railways over long distances. Alternating pipelines is very serious in laboratory experiments were current (AC) corrosion of such cases. In this work, carried out with an electrochemical method in a simulated soil solution at various AC current densities from 0 to 200 A]m2 and AC frequencies from 10 to 200 Hz. Experimental results indicated that with an increase in the AC current density, the corrosion po- tential of an X60 steel electrode shifted negatively, the anodic current density increased significantly, and the corrosion rate increased. Moreover, with an increase in the AC frequency, the corrosion potential of the X60 electrode shifted positively and the anodic current density decreased, which led to a decrease in the corrosion rate. Furthermore, the morphology of X60 electrodes indicated that uniform corrosion occurred at a low AC current density; while corrosion pits were found on the X60 electrode surface at a high AC current density, and deep corrosion pits seriously damaged the pipelines and might lead to leakage. 展开更多
关键词 alternating current interference - X60pipeline steel CORROSION AC current density - ACfrequency
下载PDF
Reversibility of visual field defects through induction of brain plasticity: vision restoration, recovery and rehabilitation using alternating current stimulation 被引量:8
3
作者 Bernhard A.Sabel Ying Gao Andrea Antal 《Neural Regeneration Research》 SCIE CAS CSCD 2020年第10期1799-1806,共8页
For decades visual field defects were considered irreversible because it was thought that in the visual system the regeneration potential of the neuronal tissues is low.Nevertheless,there is always some potential for ... For decades visual field defects were considered irreversible because it was thought that in the visual system the regeneration potential of the neuronal tissues is low.Nevertheless,there is always some potential for partial recovery of the visual field defect that can be achieved through induction of neuroplasticity.Neuroplasticity refers to the ability of the brain to change its own functional architecture by modulating synaptic efficacy.It is maintained throughout life and just as neurological rehabilitation can improve motor coordination,visual field defects in glaucoma,diabetic retinopathy or optic neuropathy can be improved by inducing neuroplasticity.In ophthalmology many new treatment paradigms have been tested that can induce neuroplastic changes,including non-invasive alternating current stimulation.Treatment with alternating current stimulation(e.g.,30 minutes,daily for 10 days using transorbital electrodes and^10 Hz)activates the entire retina and parts of the brain.Electroencephalography and functional magnetic resonance imaging studies revealed local activation of the visual cortex,global reorganization of functional brain networks,and enhanced blood flow,which together activate neurons and their networks.The future of low vision is optimistic because vision loss is indeed,partially reversible. 展开更多
关键词 alternating current stimulation glaucoma low vision optic nerve REHABILITATION RECOVERY stress VISION vision restoration therapy visual field
下载PDF
Alternating Pulse Current in Eiectrocoagulation for Wastewater Treatment to Prevent the Passivation of Al Electrode 被引量:2
4
作者 MAO Xuhui HONG Song +3 位作者 ZHU Hua LIN Hui WEI Lin GAN Fuxing 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2008年第2期239-241,共3页
A novel current feed style, alternating pulse current, was proposed in electrocoagulation aiming at preventing the passivation of electrode materials. The open circuit potential (OCP) measurements after anodic and c... A novel current feed style, alternating pulse current, was proposed in electrocoagulation aiming at preventing the passivation of electrode materials. The open circuit potential (OCP) measurements after anodic and cathodic potentiodynamic polarization showed that cathodic polarization could activate Al electrode. The surface of Al electrode after alternating pulse current electrocoagulation was investigated by scanning electron microscope (SEM) and X-ray photoelectron spectroscopy (XPS), and the results indicate that passivation of Al is not observed. Furthermore, the simulated wastewater treatment tests show that alternating pulse current electrocoagulation has a visible energy saving effect and is worthy of generalization. 展开更多
关键词 alternating pulse current ELECTROCOAGULATION passivation of Al
下载PDF
Sediment Movement in Periodic Alternating Current 被引量:11
5
作者 CAOZude KONGLingshuang LIUDefu 《Journal of Ocean University of Qingdao》 2002年第2期201-205,共5页
The present paper summarizes the results of previous studies, including the structure and principle of the rotary ring flume for researching the fine sediment movement, the mechanism of the flume, method of eliminatin... The present paper summarizes the results of previous studies, including the structure and principle of the rotary ring flume for researching the fine sediment movement, the mechanism of the flume, method of eliminating the influence of the centrifugal force and sediment movement experiments with periodic alternating current. Also included are the experiment-based relationship among sediment concentration, bed shear stress and silt carrying capacity, a proposed erosion-deposition function and bed erosion-deposition calculation together with the results of verification. 展开更多
关键词 rotary ring flume periodic alternating current hydraulic characteristics of sediment erosion-deposition function
下载PDF
Monitoring the spontaneous wetting process of hydrophobic microporous membrane assisted by alternating current impedance spectroscopy 被引量:1
6
作者 Juntian Xiao Qian Sun +1 位作者 Liying Liu Zhongwei Ding 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第11期96-102,共7页
In the process of membrane absorption,spontaneous wetting of hydrophobic microporous membrane causes membrane modification and increases membrane phase mass transfer resistance,which have attracted wide interest.Howev... In the process of membrane absorption,spontaneous wetting of hydrophobic microporous membrane causes membrane modification and increases membrane phase mass transfer resistance,which have attracted wide interest.However,due to the limitations of previous testing methods,the study of the spontaneous membrane wetting process is limited.Herein,we present a method for monitoring spontaneous membrane wetting by measuring its alternating current(AC)impedance.The impedance tests of the PVDF flat membranes and hollow fiber membranes were conducted in a two-electrode system.The results of equivalent circuit fitting indicate that the impedance value of the unwetted membrane is about 1.02×10^(10)Ω,which is close to the theoretical value of 1.4×10^(10)Ω,and this method can quantify the electrochemical impedance value of membranes with different degrees of spontaneous wetting.In addition,a method of impedance test for real-time monitoring of spontaneous wetting was designed.During the experiment,the timeliness and continuity of this method are confirmed with exact judgment under different conditions.In future work,the impedance data will be used to build model to predict the percentage of membrane wetting degree. 展开更多
关键词 alternating current impedance Spontaneous membrane wetting Hydrophobic membrane Dynamic monitoring
下载PDF
Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration 被引量:6
7
作者 Jun Ping Xiao Qing Xiang Zhou +2 位作者 Xiao Ke Tian Hua Hua Bai Xian Fa Su 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期730-733,共4页
A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosa... A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail. The experimental results indicated that this method was simple, rapid, and sensitive. The linear range was 8.367 × 10(?4) to 2.789 × 10(?2) mol L(?1), the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4–106.9% under the optimal conditions. The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples. 展开更多
关键词 alternating-current oscillopolarographic titration ANILINE Potassium bromide
下载PDF
Flow separation control over an airfoil using continuous alternating current plasma actuator 被引量:1
8
作者 Jian-Guo Zheng 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第3期346-355,共10页
The flow separation control over an NACA 0015 airfoil using continuous alternating current(AC)dielectric barrier discharge(DBD)plasma actuator is investigated experimentally and numerically.This work is intended to re... The flow separation control over an NACA 0015 airfoil using continuous alternating current(AC)dielectric barrier discharge(DBD)plasma actuator is investigated experimentally and numerically.This work is intended to report some observations made from our experiment,to which little attention is paid in the previous studies,but which is thought to be important to the understanding of control of complex flow separation with AC DBD.To this end,the response of separated flow to AC plasma actuation is visualized through the time-resolved particle image velocimetry(PIV)measurement,whereas numerical simulation is carried out to complement the experiment.The flow control process at chord-based Reynolds number(Re)of 3.31×105 is investigated.It is found that the response of external flow to plasma forcing is delayed for up to tens of milliseconds and the delay time increases with angle of attack increasing.Also observed is that at the intermediate angle of attack near stall,the forced flow features a well re-organized flow pattern.However,for airfoil at high post-stall angle of attack,the already well suppressed flow field can recover to the massively separated flow state and then reattach to airfoil surface with the flow pattern fluctuating between the two states in an irregular manner.This is contrary to one’s first thought that the forced flow at any angles of attack will become well organized and regular,and reflects the complexity of flow separation control. 展开更多
关键词 dielectric barrier discharge plasma actuator alternating current plasma discharge flow separation flow control delayed response
原文传递
Effects of alternating current imposition and alkaline earth elements on modification of primary Mg_2Si crystals in hypereutectic Mg-Si alloy 被引量:10
9
作者 杜军 K.IWAI +1 位作者 李文芳 彭继华 《中国有色金属学会会刊:英文版》 EI CSCD 2009年第5期1051-1056,共6页
The effects of alternating current imposition and/or alkaline earth elements on modification of the primary Mg2Si crystals in the hypereutectic Mg-Si alloy were investigated.An alternating current of 60 A with frequen... The effects of alternating current imposition and/or alkaline earth elements on modification of the primary Mg2Si crystals in the hypereutectic Mg-Si alloy were investigated.An alternating current of 60 A with frequency of 1 kHz was applied into the hypereutectic Mg-Si melt which was alloyed with alkaline earth elements or not in the fixed temperature range from 700 to 630℃. The results show that the primary Mg2Si crystals could be refined by imposing alternating current or adding alkaline elements. Compared with the samples treated by adding 0.4%Ca or 0.4%Sr,higher modification efficiency could be obtained for the samples treated by imposing alternating current.No further modification efficiency could be obtained for the samples treated by imposing alternating current combined with 0.4%Ca or 0.4%Sr addition. 展开更多
关键词 MG2SI 金属元素 交流电 碱土 修改 晶体 合金
下载PDF
Continuous electromagnetic separation of inclusion from aluminum melt using alternating current 被引量:6
10
作者 张邦文 任忠鸣 吴加雄 《中国有色金属学会会刊:英文版》 EI CSCD 2006年第1期33-38,共6页
A novel scheme about the continuous electromagnetic purification of aluminum melt was put forward based on the utilization of a square separation pipe and a 50 Hz alternating current to produce electromagnetic force. ... A novel scheme about the continuous electromagnetic purification of aluminum melt was put forward based on the utilization of a square separation pipe and a 50 Hz alternating current to produce electromagnetic force. It is experimentally found that with electrical current of 400 A/cm2, it takes only 10 s to remove 95% inclusion from aluminum melt. Comprehensive numerical simulations were carried out to investigate the dynamics mechanisms behind the process. The results show that the removal of inclusion is attributed to the cooperative effects of electromagnetic buoyancy and the secondary flow induced by the rotational electromagnetic force, and the removal efficient increases with the size of inclusion and the electrical current imposed. Theoretical predictions on the distribution and removal efficiency of inclusion were supported by the experiments. 展开更多
关键词 电磁分离 铝合金 交互电流 熔炼 电磁净化
下载PDF
Rapid determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration 被引量:1
11
作者 XIAO Jun-ping WANG Xue-feng +4 位作者 ZHOU Qing-xiang FAN Xiao-yuan SU Xian-fa Bai Hua-hua DUAN Hai-jing 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第5期622-627,共6页
A rapid, simple and sensitive method was demonstrated for the determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration. With the presence of sulfuric acid, phenol coul... A rapid, simple and sensitive method was demonstrated for the determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration. With the presence of sulfuric acid, phenol could be transferred into a nitroso-compound by reacting with NaNO2. The titration end-point was obtained by the formation of a sharp cut in the oscillopolarographic with infinitesimal NaNO2 on double platinum electrodes. The results showed that phenol had an excellent linear relationship over the range of 4.82×10^-6 -9.65×10^-3 mol/L, the RSD of the proposed method was lower than 1.5%, and the spiked recoveries of three real water samples were in the range of 95.6%-106.9%. 展开更多
关键词 alternating-current oscillopolarographic titration phenolic compounds
下载PDF
Experimental design to measure the anchoring energy on substrate surface by using the alternating-current bridge 被引量:1
12
作者 郝慧明 刘瑶瑶 +4 位作者 张平 蔡明雷 王晓燕 朱吉亮 叶文江 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第8期315-319,共5页
The anchoring property of the substrate surface of liquid crystal cells plays an important role in display and nondisplay fields. This property directly affects the deformation of liquid crystal molecules to change th... The anchoring property of the substrate surface of liquid crystal cells plays an important role in display and nondisplay fields. This property directly affects the deformation of liquid crystal molecules to change the phase difference through liquid crystal cells. In this paper, a test method based on the alternating-current bridge is proposed to determine the capacitance of liquid crystal cells and thus measure the anchoring energy of the substrate surface. The anchoring energy can be obtained by comparing the capacitance-voltage curves of twisted nematic liquid crystal cells with different anchoring properties in experimental and theoretical results simulated on the basis of Frank elastic theory. Compared with the other methods to determine the anchoring energy, our proposed method requires a simple treatment of liquid crystal cells and allows easy and high-accuracy measurements, thereby expanding the test ideas on the performance parameters of liquid crystal devices. 展开更多
关键词 anchoring energy alternating-current bridge capacitance of liquid crystal cell twisted nematic
原文传递
Research and exploration of direct current power supply and distribution systems for Antarctic research stations
13
作者 WANG Lei 《Advances in Polar Science》 CSCD 2024年第2期228-237,共10页
The power supply and distribution systems for Antarctic research stations have special characteristics.In light of a worldwide trend toward a gradual increase in the application of renewable energy,an analysis was per... The power supply and distribution systems for Antarctic research stations have special characteristics.In light of a worldwide trend toward a gradual increase in the application of renewable energy,an analysis was performed to assess the feasibility of achieving a direct current power supply and distribution at Antarctic research stations by comparing the characteristics of direct current and alternating current electricity.Research was also performed on the status quo and future trends in direct current power supply and distribution systems in Antarctica research stations in combination with case studies. 展开更多
关键词 direct current alternating current renewable energy ANTARCTIC research station
下载PDF
Electrical Characteristics of an Alternating Current Plasma Igniter in Airflow
14
作者 赵兵兵 何立明 +1 位作者 杜宏亮 张华磊 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第4期370-373,共4页
The electrical characteristics of an alternating current (AC) plasma igniter were investigated for a working gas of air at atmospheric pressure. The discharge voltage and current were measured in air in both breakdo... The electrical characteristics of an alternating current (AC) plasma igniter were investigated for a working gas of air at atmospheric pressure. The discharge voltage and current were measured in air in both breakdown and stable combustion processes, respectively, and the current-zero phenomena, voltage-current (V-I) characteristics were studied for different working gas flow rates. The results indicated that the working gas between anode and cathode could be ionized to generate gas discharge when the voltage reached 8 kV, and the maximum current was 33.36 A. When the current came to zero, current-zero phenomena appeared with duration of 2 #s. At the current-zero moment, dynamic resistance between electrodes became extremely high, and the maximum value could reach 445 kf~, which was the main factor to restrain the current. With increasing working gas flow rates, the gradient of V-I characteristic curves was increased, as was the dynamic resistance. At a constant driven power, the discharge voltage increased. 展开更多
关键词 alternating current discharge plasma igniter voltage-current characteristic current-zero phenomena
下载PDF
Characterization of alternating current impedance properties of biomedical electrodes
15
作者 周伟 程德才 +3 位作者 宋嵘 张春健 许文平 潘晓玲 《Journal of Central South University》 SCIE EI CAS 2013年第5期1254-1258,共5页
To study the alternating current (AC) impedance properties of Ag/AgC1 electrocardiograph (ECG) electrodes, the electrode pair was gel-to-gel connected, and then the electrical potential was recorded after a safe s... To study the alternating current (AC) impedance properties of Ag/AgC1 electrocardiograph (ECG) electrodes, the electrode pair was gel-to-gel connected, and then the electrical potential was recorded after a safe stimulating current passes through the electrode pair, so the AC impedance data of ECG electrodes were obtained. Varying the frequency and value of stimulating current, the detailed comparison and analysis of AC impedance properties of the electrodes were performed, and the stability was further characterized by using the continuous measurement within 24 h. The experimental results show that the AC impedance values of electrodes decreased, and then slightly increased with the increase of frequency of stimulating current. The minimum AC impedance value was obtained when the frequency was changed to 10 kHz. When the stimulating current increased, the AC impedance values of electrodes showed a slight decrease, but did not change significantly. Besides, the continuous measurement results show that the impedance value presented a significant increase in the initial 30 min, and then was stabilized in the following measuring process. 展开更多
关键词 bioelectrical impedance electrocardiograph electrodes alternating current impedance frequency properties currentproperties
下载PDF
Soft measurement model on torque of alternating current electrical dynamometer including copper loss and iron loss
16
作者 ZHONG Ding-qing WANG Ai-lun HE Qian 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第8期2272-2280,共9页
Alternating current electrical dynamometer is a common device to measure the torque of engines, such as the gasoline engine. In order to solve the problems such as high cost, high energy consumption and complicated me... Alternating current electrical dynamometer is a common device to measure the torque of engines, such as the gasoline engine. In order to solve the problems such as high cost, high energy consumption and complicated measurement system which exists in the direct measurement on the torque of alternating current electrical dynamometer, copper loss and iron loss are taken as two key factors and a soft-sensing model on the torque of alternating current electrical dynamometer is established using the fuzzy least square support vector machine (FLS-SVM). Then, the FLS-SVM parameters such as penalty factor and kernel parameter are optimized by adaptive genetic algorithm, torque soft-sensing is investigated in the alternating current electrical dynamometer, as well as the energy feedback efficiency and energy consumption during the measurement phase of a gasoline engine loading continual test is obtained. The results show that the minimum soft-sensing error of torque is about 0.0018, and it fluctuates within a range from -0.3 to 0.3 N·m. FLS-SVM soft-sensing method can increase by 1.6% power generation feedback compared with direct measurement, and it can save 500 kJ fuel consumption in the gasoline engine loading continual test. Therefore, the estimation accuracy of the soft measurement model on the torque of alternating current electrical dynamometer including copper loss and iron loss is high and this indirect measurement method can be feasible to reduce production cost of the alternating current electrical dynamometer and energy consumption during the torque measurement phase of a gasoline engine, replacing the direct method of torque measurement. 展开更多
关键词 TORQUE fuzzy theory least square support vector machine alternating current electrical dynamometer
下载PDF
Alternating Current Heating Technique of Hollow Rod
17
作者 Na Weisheng and Shi Tonghao(Survey & Design Institute, Liaohe Oilfield) 《China Oil & Gas》 CAS 1995年第4期42-44,共3页
AlternatingCurrentHeatingTechniqueofHollowRod¥NaWeishengandShiTonghao(Survey&DesignInstitute,LiaoheOilfield)... AlternatingCurrentHeatingTechniqueofHollowRod¥NaWeishengandShiTonghao(Survey&DesignInstitute,LiaoheOilfield)Keywords:Crudeoil... 展开更多
关键词 CRUDE oil. Well bore. Heating. alternating current. ROD PUMP
下载PDF
Alternating-current losses in two-layer superconducting cables consisting of second-generation superconductors coated by U-shaped ferromagnetic materials 被引量:1
18
作者 Ahmet Cicek Fedai Inanir Fedor Gmry 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第12期509-513,共5页
Alternating-current losses in a two-layer superconducting cable, each layer being composed of 15 closely-spaced rectangular wires made up of second-generation superconductors when the ends of wires are coated by eithe... Alternating-current losses in a two-layer superconducting cable, each layer being composed of 15 closely-spaced rectangular wires made up of second-generation superconductors when the ends of wires are coated by either a non-magnetic or strong ferromagnetic material having a U profile is numerically investigated. Computations are carried out through the finite-element method. The alternating-current losses do not increase significantly if the relative permeability of the coating is increased three orders of magnitude, provided that the current amplitude is less than half of the critical current in a superconducting wire. However, the losses are much higher for ferromagnetic coating if the amplitude of the applied current oscillating at 50 Hz is close to the critical current. The ferromagnetic coating is seen to accumulate the magnetic field lines normally on its surfaces, while the field lines are parallel to the long axes of the wires, leading to more significant flux penetration in the coated regions. This facilitates a uniform low-loss current flow in the uncoated regions of the wires. In contrast, coating with a non-magnetic material gives rise to a considerably smaller current flow in the uncoated regions, whereas the low-loss flow is maintained in the coated regions. Moreover, the current flows in opposite directions in the coated and uncoated regions, where the direction in each region is converse for the two materials. 展开更多
关键词 second-generation superconductor two-layer cable ferromagnetic coating U profile alternating-current losses
原文传递
EFFECT OF DIFFERENT WAVEFORM'S ALTERNATING CURRENT ON THE INCISION'S SENSITIVITY
19
作者 Shu Ping BIHong GAO (H.KAO) Department of Chemistry, Nanjing University, Nanjing, 210008 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第11期983-984,共2页
Compared with the conventionally used i=iosinωt alternating current, using asymmetric triangular and pulse wave as input signals can greatly enhance the incision's sensitivity of 'dE/dt-E'oscillogram.
关键词 KBR EFFECT OF DIFFERENT WAVEFORM’S alternating current ON THE INCISION’S SENSITIVITY
下载PDF
Basic Concepts for Alternating Current through Educational Videos
20
作者 Gilmar Barreto Carlos Alberto Favarin Murari 《Journal of Mechanics Engineering and Automation》 2014年第11期914-918,共5页
This article highlights the importance of complementing classes through educational videos, especially in disciplines exclusively with lectures. This proposition is exemplified through basic concepts in alternating cu... This article highlights the importance of complementing classes through educational videos, especially in disciplines exclusively with lectures. This proposition is exemplified through basic concepts in alternating current for both single-phase and three-phase circuits, which are critical in the formation of electrical engineers, mechanics, chemists, etc. The main objective of conducting educational videos is to make learning more attractive and stimulate interest in acquiring the knowledge of certain topics, given their importance in professional life in different engineering areas. The videos, filmed in laboratory and of short duration, aim to complement and consolidate the content taught in the classroom lectures. 展开更多
关键词 AUDIOVISUAL alternating current circuits electrotechnical engineering education educational videos
下载PDF
上一页 1 2 80 下一页 到第
使用帮助 返回顶部