Evaporation erosion of the contacts is one of the fundamental failure mechanisms for relays. In this paper, the evaporation erosion characteristics are investigated for the copper contact pair breaking a resistive dir...Evaporation erosion of the contacts is one of the fundamental failure mechanisms for relays. In this paper, the evaporation erosion characteristics are investigated for the copper contact pair breaking a resistive direct current (dc) 30 V/10 A circuit in the air. Molten pool simulation of the contacts is coupled with the gas dynamics to calculate the evaporation rate. A simplified arc model is constructed to obtain the contact voltage and current variations with time for the prediction of the current density and the heat flux distributions flowing from the arc into the contacts. The evaporation rate and mass variations with time during the breaking process are presented. Experiments are carried out to verify the simulation results.展开更多
An arc model in SiO2 current-limiting fuse has been put forward. Through taking into account the comprehensive effects such as: fundamental action process among particles of arc column, geometrical and external circui...An arc model in SiO2 current-limiting fuse has been put forward. Through taking into account the comprehensive effects such as: fundamental action process among particles of arc column, geometrical and external circuit characteristics of arc column, physical procedure in arc column and in cathode and anode, and power equilibrium in arc column plasma et al., parameters such as the temperature, length, volumn, pressure, arc voltage, arc current et al. in the arc column can be obtained by the model. In view of the serious nonlinearity and huge difference among parameters in the equation set of the model, via analysis on these equations, two solution methods for the equations of the model have been presented with a basic accordance between calculated results and test results.展开更多
Conventional arc models are usually used to research the interaction between switching arc and circuit. It is important to simulate the fault arc for arc flash calculations, choice of electrical equipments and power s...Conventional arc models are usually used to research the interaction between switching arc and circuit. It is important to simulate the fault arc for arc flash calculations, choice of electrical equipments and power system protection. This paper investigates several conventional arc models for calculating the fault arcing current. Simulation results show that conventional arc models can be used to simulate the fault arc if the parameters of arc models are given properly. This paper provides the parameters of 5 popular arc models and describes the simulation results of the fault arc.展开更多
Since the epidemic,online classes have been a common practice,and learning motivation plays a key role in the efficiency of the online English,which should not be underestimated in improving online foreign language te...Since the epidemic,online classes have been a common practice,and learning motivation plays a key role in the efficiency of the online English,which should not be underestimated in improving online foreign language teaching.This paper discusses how to effectively apply ARCS motivation model in online English teaching design with examples of college English textbooks,so as to motivate students and improve students’online classroom efficiency by improving their learning motivation.展开更多
To simulate the process of electrode operation, a dynamic model describing the electrode system of three-phase electric arc furnace was developed. This new model can be divided into three submodels in terms of the pra...To simulate the process of electrode operation, a dynamic model describing the electrode system of three-phase electric arc furnace was developed. This new model can be divided into three submodels in terms of the practical situation. They are the power supply system model the electric arc model and the hydraulic actuator system model. According to the basic circuit theory, the power supply system model where the high voltage transmission circuit and mutual inductances were considered, was set up. The electric arc model, which was novel for the electrode control, served as the electrical load and was connected to the power supply system model. The hydraulic actuator system model consists of the proportional valve part that is modeled to capture the dead-zone nonlinear characteristics and the hydraulic cylinder part where the impact of the load force is taken into account. By comparing simulation data and actual data, the results show that the electrode system model is proved to be accurate.展开更多
基金supported by National Natural Science Foundation of China(Nos.51377038,51307030)
文摘Evaporation erosion of the contacts is one of the fundamental failure mechanisms for relays. In this paper, the evaporation erosion characteristics are investigated for the copper contact pair breaking a resistive direct current (dc) 30 V/10 A circuit in the air. Molten pool simulation of the contacts is coupled with the gas dynamics to calculate the evaporation rate. A simplified arc model is constructed to obtain the contact voltage and current variations with time for the prediction of the current density and the heat flux distributions flowing from the arc into the contacts. The evaporation rate and mass variations with time during the breaking process are presented. Experiments are carried out to verify the simulation results.
文摘An arc model in SiO2 current-limiting fuse has been put forward. Through taking into account the comprehensive effects such as: fundamental action process among particles of arc column, geometrical and external circuit characteristics of arc column, physical procedure in arc column and in cathode and anode, and power equilibrium in arc column plasma et al., parameters such as the temperature, length, volumn, pressure, arc voltage, arc current et al. in the arc column can be obtained by the model. In view of the serious nonlinearity and huge difference among parameters in the equation set of the model, via analysis on these equations, two solution methods for the equations of the model have been presented with a basic accordance between calculated results and test results.
文摘Conventional arc models are usually used to research the interaction between switching arc and circuit. It is important to simulate the fault arc for arc flash calculations, choice of electrical equipments and power system protection. This paper investigates several conventional arc models for calculating the fault arcing current. Simulation results show that conventional arc models can be used to simulate the fault arc if the parameters of arc models are given properly. This paper provides the parameters of 5 popular arc models and describes the simulation results of the fault arc.
文摘Since the epidemic,online classes have been a common practice,and learning motivation plays a key role in the efficiency of the online English,which should not be underestimated in improving online foreign language teaching.This paper discusses how to effectively apply ARCS motivation model in online English teaching design with examples of college English textbooks,so as to motivate students and improve students’online classroom efficiency by improving their learning motivation.
基金Projects(2007AA04Z194, 2007AA041401) supported by the National High-Tech Research and Development Program of China
文摘To simulate the process of electrode operation, a dynamic model describing the electrode system of three-phase electric arc furnace was developed. This new model can be divided into three submodels in terms of the practical situation. They are the power supply system model the electric arc model and the hydraulic actuator system model. According to the basic circuit theory, the power supply system model where the high voltage transmission circuit and mutual inductances were considered, was set up. The electric arc model, which was novel for the electrode control, served as the electrical load and was connected to the power supply system model. The hydraulic actuator system model consists of the proportional valve part that is modeled to capture the dead-zone nonlinear characteristics and the hydraulic cylinder part where the impact of the load force is taken into account. By comparing simulation data and actual data, the results show that the electrode system model is proved to be accurate.