The effects of higher modes and torsion have a significant impact on the seismic responses of asymmetric-plan tall buildings. A consecutive modal pushover (CMP) procedure is one of the pushover methods that have been ...The effects of higher modes and torsion have a significant impact on the seismic responses of asymmetric-plan tall buildings. A consecutive modal pushover (CMP) procedure is one of the pushover methods that have been developed to consider these effects. The aim of this paper is to modify the (CMP) analysis procedure to estimate the seismic demands of one-way asymmetric-plan tall buildings with dual systems. An analysis of 10-, 15- and 20-story asymmetric-plan buildings is carried out, and the results from the modified consecutive modal pushover (MCMP) procedure are compared with those obtained from the modal pushover analysis (MPA) procedure and the nonlinear time history analysis (NLTHA). The MCMP estimates of the seismic demands of one-way asymmetric-plan buildings demonstrate a reasonable accuracy, compared to the results obtained from the NLTHA. Furthermore, the accuracy of the MCMP procedure in the prediction of plastic hinge rotations is better than the MPA procedure. The new pushover procedure is also more accurate than the FEMA load distribution and the MPA procedure.展开更多
A pushover procedure with a load pattern based on the height-wise distribution of the combined modal story shear and torsional moment is proposed to estimate the seismic response of 3D asymmetric-plan building frames....A pushover procedure with a load pattern based on the height-wise distribution of the combined modal story shear and torsional moment is proposed to estimate the seismic response of 3D asymmetric-plan building frames. Contribution of the higher modes and torsional response of asymmetric-plan buildings are incorporated into the proposed load pattern. The proposed pushover method is a single-run procedure, which enables tracing the nonlinear response of the structure during the analysis and averts the elusiveness of conducting multiple pushover analyses. The proposed method has been used to estimate the response of two moment-resisting building frames with 9 and 20 stories. The obtained results indicate the appropriate accuracy and efficiency of the proposed procedure in estimating the trend of the drift profiles of the structures resulted from nonlinear time history analyses.展开更多
文摘The effects of higher modes and torsion have a significant impact on the seismic responses of asymmetric-plan tall buildings. A consecutive modal pushover (CMP) procedure is one of the pushover methods that have been developed to consider these effects. The aim of this paper is to modify the (CMP) analysis procedure to estimate the seismic demands of one-way asymmetric-plan tall buildings with dual systems. An analysis of 10-, 15- and 20-story asymmetric-plan buildings is carried out, and the results from the modified consecutive modal pushover (MCMP) procedure are compared with those obtained from the modal pushover analysis (MPA) procedure and the nonlinear time history analysis (NLTHA). The MCMP estimates of the seismic demands of one-way asymmetric-plan buildings demonstrate a reasonable accuracy, compared to the results obtained from the NLTHA. Furthermore, the accuracy of the MCMP procedure in the prediction of plastic hinge rotations is better than the MPA procedure. The new pushover procedure is also more accurate than the FEMA load distribution and the MPA procedure.
文摘A pushover procedure with a load pattern based on the height-wise distribution of the combined modal story shear and torsional moment is proposed to estimate the seismic response of 3D asymmetric-plan building frames. Contribution of the higher modes and torsional response of asymmetric-plan buildings are incorporated into the proposed load pattern. The proposed pushover method is a single-run procedure, which enables tracing the nonlinear response of the structure during the analysis and averts the elusiveness of conducting multiple pushover analyses. The proposed method has been used to estimate the response of two moment-resisting building frames with 9 and 20 stories. The obtained results indicate the appropriate accuracy and efficiency of the proposed procedure in estimating the trend of the drift profiles of the structures resulted from nonlinear time history analyses.