期刊文献+
共找到951篇文章
< 1 2 48 >
每页显示 20 50 100
Two-dimensional atom localization via probe absorption in a four-level atomic system
1
作者 王志平 葛强 +1 位作者 阮于华 俞本立 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期202-207,共6页
We have investigated the two-dimensional (2D) atom localization via probe absorption in a coherently driven four-level atomic system by means of a radio-frequency field driving a hyperfine transition. It is found th... We have investigated the two-dimensional (2D) atom localization via probe absorption in a coherently driven four-level atomic system by means of a radio-frequency field driving a hyperfine transition. It is found that the detecting probability and precision of 2D atom localization can be significantly improved via adjusting the system parameters. As a result, our scheme may be helpful in laser cooling or the atom nano-lithography via atom localization. 展开更多
关键词 two-dimensional (2D) atom localization probe absorption four-level atomic system
原文传递
High-precision two-dimensional atom localization via probe absorption in an M-scheme atomic system
2
作者 吴建春 刘正东 郑军 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第4期264-267,共4页
In the present paper, we investigate the behavior of two-dimensional atom localization in a five-level M-scheme atomic system driven by two orthogonal standing-wave fields. We find that the precision and resolution of... In the present paper, we investigate the behavior of two-dimensional atom localization in a five-level M-scheme atomic system driven by two orthogonal standing-wave fields. We find that the precision and resolution of the atom localization depends on the probe field detuning significantly. And because of the effect of the microwave field, an atom can be located at a particular position via adjusting the system parameters. 展开更多
关键词 two-dimensional atom localization probe absorption
原文传递
ACCELERATOR-BASED ATOMIC PHYSICS AT THE LAWRENCE BERKELEY LABORATOTY:COLLISIONS OF FAST,HIGHLY-CHARGED IONS WITH ATOMS
3
作者 AlfredS.Schlachter 《Nuclear Science and Techniques》 SCIE CAS CSCD 1990年第Z1期32-39,共8页
Research on accelerator-based atomic physics at the Lawrence Berkeley Laboratory super-HILAC and Bevalac accelerators is described. This research covers several important topics in collisions of fast, highly charged i... Research on accelerator-based atomic physics at the Lawrence Berkeley Laboratory super-HILAC and Bevalac accelerators is described. This research covers several important topics in collisions of fast, highly charged ions with atoms: charge transfer, ionization, and excitation. Multiple - electron processes are emphasized. Electron correlation is important in some of these processes, e.g., resonance transfer and excitation (RTE) multiple-electron capture in close collisions. A variety of experiments and results for energies from 1 to 420 MeV/u are presented. 展开更多
关键词 ACCELERATOR atomic physics COLLISIONS of IONS with ATOMS
下载PDF
Spatial Splitting and Intensity Suppression of Four-Wave Mixing in V-Type Three-Level Atomic System
4
作者 李创社 尹伟涛 +3 位作者 袁晨智 史美震 赵燕 张彦鹏 《Chinese Physics Letters》 SCIE CAS CSCD 2010年第4期140-142,共3页
We illustrate our experimental observation of coexisting the controllable spatial splitting and intensity suppression of four-wave mixing (FWM) beam in a V-type three-level atomic system. The peak number and separat... We illustrate our experimental observation of coexisting the controllable spatial splitting and intensity suppression of four-wave mixing (FWM) beam in a V-type three-level atomic system. The peak number and separation distance of the FWM beam are controlled by the intensities and frequencies of the laser beams, as well as atomic density. 展开更多
关键词 atomic and molecular physics Optics quantum optics and lasers
原文传递
Upgrade of an integrated Langmuir probe system on the closed divertor target plates in the HL-2A tokamak
5
作者 Zhihui HUANG Jun CHENG +14 位作者 Na WU Longwen YAN Hongbing XU Weice WANG Xianggan MIAO Kaiyang YI Jianqiang XU Laizhong CAI Zhongbing SHI Jiaqi DONG Yi LIU Wulyu ZHONG Qingwei YANG Min XU Xuru DUAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第5期9-16,共8页
A newly designed divertor Langmuir probe diagnostic system has been installed in a rare closed divertor of the HL-2A tokamak and steadily operated for the study of divertor physics involved edge-localized mode mitigat... A newly designed divertor Langmuir probe diagnostic system has been installed in a rare closed divertor of the HL-2A tokamak and steadily operated for the study of divertor physics involved edge-localized mode mitigation,detachment and redistribution of heat flux,etc.Two sets of probe arrays including 274 probe tips were placed at two ports(approximately 180°separated toroidally),and the spatial and temporal resolutions of this measurement system could reach6 mm and 1μs,respectively.A novel design of the ceramic isolation ring can ensure reliable electrical insulation property between the graphite tip and the copper substrate plate where plasma impurities and the dust are deposited into the gaps for a long experimental time.Meanwhile,the condition monitoring and mode conversion between single and triple probe of the probe system could be conveniently implemented via a remote-control station.The preliminary experimental result shows that the divertor Langmuir probe system is capable of measuring the high spatiotemporal parameters involved the plasma density,electron temperature,particle flux as well as heat flux during the ELMy H-mode discharges. 展开更多
关键词 Langmuir probe H-mode discharge HL-2A tokamak divertor physics
下载PDF
Scanning transmission electron microscopy and atom probe tomography analysis of non-stoichiometry long-period-stacking-ordered structures in Mg-Ni-Y/Sm alloys
6
作者 Yimeng Chen Manuel Legrée +1 位作者 Jean-Louis Bobet Alexander Kvit 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第3期954-965,共12页
The long-period-stacking-ordered(LPSO)structure affects the mechanical,corrosion and hydrolysis properties of Mg alloys.The current work employs high angle annular dark field-scanning transmission electron microscopy(... The long-period-stacking-ordered(LPSO)structure affects the mechanical,corrosion and hydrolysis properties of Mg alloys.The current work employs high angle annular dark field-scanning transmission electron microscopy(HAADF-STEM)and atom probe tomography(APT)to investigate the structural and local chemical information of LPSO phases formed in Mg-Ni-Y/Sm ternary alloys after extended isothermal annealing.Depending on the alloying elements and their concentrations,Mg-Ni-Y/Sm develops a two-phase LPSO+α-Mg structure in which the LPSO phase contains defects,hybrid LPSO structure,and Mg insertions.HAADF-STEM and APT indicate non-stoichiometric LPSO with incomplete Ni_(6)(Y/Sm)_(8) clusters.In addition,the APT quantitatively determines the local composition of LPSO and confirms the presence of Ni within the Mg bonding layers.These results provide insight into a better understanding of the structure and hydrolysis properties of LPSO-Mg alloys. 展开更多
关键词 Magnesium alloys Long-range ordering Atom probe tomography(APT) STEM HAADF Hydrolysis properties.
下载PDF
A novel atomic force microscope operating in liquid with open probe unit and optimized laser tracking system
7
作者 伏霞 张冬仙 章海军 《Chinese Optics Letters》 SCIE EI CAS CSCD 2009年第10期891-893,共3页
A novel atomic force microscope (AFM) for large samples to be measured in liquid is developed. An innovative laser beam tracking system is proposed to eliminate the tracking and feedback errors. The open probe desig... A novel atomic force microscope (AFM) for large samples to be measured in liquid is developed. An innovative laser beam tracking system is proposed to eliminate the tracking and feedback errors. The open probe design of the AFM makes the operation in liquid convenient and easy. A standard 1200-lines/mm grating and a sheet of filter paper axe imaged respectively in air and liquid to confirm its performance. The corrosion behavior of aluminum surface in 1-mol/L NaOH solution is further investigated by the AFM. Experimental results show that the system can realize wide range (20 × 20 (μm)) scanning for large samples both in air and liquid, while keeping nanometer order resolution in liquid by eliminating the tracking and feedback error. 展开更多
关键词 Air filters atomic force microscopy NAVIGATION Paper sheeting probes
原文传递
Fidelity of quantum state for interacting system of light field and atomic Bose-Einstein condensate 被引量:12
8
作者 黄春佳 周明 +2 位作者 孔凡志 方家元 莫克威 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第7期410-413,共4页
The evolution characteristics of quantum state fidelity in an interacting system of single-mode light field and atomic Bose-Einstein condensate have been studied and the influence of the initial light field intensity ... The evolution characteristics of quantum state fidelity in an interacting system of single-mode light field and atomic Bose-Einstein condensate have been studied and the influence of the initial light field intensity and the interaction among atoms of Bose-Einstein condensate on the quantum state fidelity respectively have been discussed. 展开更多
关键词 atomic physics CONDENSATION Laser applications Quantum theory
原文传递
Absorption-amplification response with or withoutspontaneously generated coherence effectin a four-level atomic system 被引量:1
9
作者 李家华 杨文星 彭菊村 《Chinese Optics Letters》 SCIE EI CAS CSCD 2004年第5期302-304,共3页
We discuss and analyze the absorption properties of a weak probe field in a typical four-level atomic system in the presence of a spontaneously generated coherence (SGC) term. The influences of the SGC and a coherent ... We discuss and analyze the absorption properties of a weak probe field in a typical four-level atomic system in the presence of a spontaneously generated coherence (SGC) term. The influences of the SGC and a coherent pump field on the probe absorption-amplification are investigated. The results show that the absorption of such a weak probe field can be dramatically enhanced due to the SGC effect. At the same time, the probe-absorption profile exhibits a two-peak structure and the probe-absorption peak gradually decreases as the pump intensity increases. On the contrary, the amplification of such a weak probe field near the line center of the probe transition can be achieved by adjusting the coherent pump field intensity in the absence of the SGC effect. 展开更多
关键词 AMPLIFICATION atomic physics Light absorption probes Quantum optics
原文传递
Precise measurement of a weak radio frequency electric field using a resonant atomic probe 被引量:5
10
作者 Liping Hao Yongmei Xue +3 位作者 Jiabei Fan Jingxu Bai Yuechun Jiao Jianming Zhao 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第3期164-168,共5页
We present a precise measurement of a weak radio frequency electric field with a frequency of ■3 GHz employing a resonant atomic probe that is constituted with a Rydberg cascade three-level atom, including a cesium g... We present a precise measurement of a weak radio frequency electric field with a frequency of ■3 GHz employing a resonant atomic probe that is constituted with a Rydberg cascade three-level atom, including a cesium ground state |6S(1/2)〉,an excited state |6P(3/2)〉, and Rydberg state |nD(5/2)〉. Two radio frequency(RF) electric fields, noted as local and signal fields, couple the nearby Rydberg transition. The two-photon resonant Rydberg electromagnetically induced transparency(Rydberg-EIT) is employed to directly read out the weak signal field having hundreds of k Hz difference between the local and signal fields that is encoded in the resonant microwave-dressed Rydberg atoms. The minimum detectable signal fields of ESmin= 1.36 ± 0.04 mV/m for 2.18 GHz coupling |68D(5/2)〉→ |69P(3/2)〉 transition and 1.33 ± 0.02 mV/m for 1.32 GHz coupling |80D(5/2)〉→ |81P(3/2)〉 transition are obtained, respectively. The bandwidth dependence is also investigated by varying the signal field frequency and corresponding -3 dB bandwidth of 3 MHz is attained. This method can be employed to perform a rapid and precise measurement of the weak electric field, which is important for the atom-based microwave metrology. 展开更多
关键词 RYDBERG electromagnetically induced transparency(Rydberg-EIT) atomic probe WEAK field measurement
原文传递
Integrated physics package of a chip-scale atomic clock 被引量:4
11
作者 李绍良 徐静 +3 位作者 张志强 赵璐冰 龙亮 吴亚明 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第7期470-474,I0003,共6页
The physics package of a chip-scale atomic clock (CSAC) has been successfully realized by integrating vertical cavity surface emitting laser (VCSEL), neutral density (ND) filter, λ/4 wave plate, 87Rb vapor cell... The physics package of a chip-scale atomic clock (CSAC) has been successfully realized by integrating vertical cavity surface emitting laser (VCSEL), neutral density (ND) filter, λ/4 wave plate, 87Rb vapor cell, photodiode (PD), and magnetic coil into a cuboid metal package with a volume of about 2.8 cm3. In this physics package, the critical component, 87Rb vapor cell, is batch-fabricated based on MEMS technology and in-situ chemical reaction method. Pt heater and thermistors are integrated in the physics package. A PTFE pillar is used to support the optical elements in the physics package, in order to reduce the power dissipation. The optical absorption spectrum of 87Rb D1 line and the microwave frequency correction signal are successfully observed while connecting the package with the servo circuit system. Using the above mentioned packaging solution, a CSAC with short-term frequency stability of about 7 × 10^-10τ-1/2 has been successfully achieved, which demonstrates that this physics package would become one promising solution for the CSAC. 展开更多
关键词 chip-scale atomic clock (CSAC) physics package 87Rb vapor cell coherent population trapping(CPT)
原文传递
IMPROVED FABRICATION METHOD FOR CARBON NANOTUBE PROBE OF ATOMIC FORCE MICROSCOPY(AFM) 被引量:1
12
作者 XU Zongwei DONG Shen +1 位作者 GUO Liqiu ZHAO Qingliang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第3期373-375,共3页
An improved arc discharge method is developed to fabricate carbon nanotube probe of atomic force microscopy (AFM) here. First, silicon probe and carbon nanotube are manipulated under an optical microscope by two hig... An improved arc discharge method is developed to fabricate carbon nanotube probe of atomic force microscopy (AFM) here. First, silicon probe and carbon nanotube are manipulated under an optical microscope by two high precision microtranslators. When silicon probe and carbon nanotube are very close, several tens voltage is applied between them. And carbon nanotube is divided and attached to the end of silicon probe, which mainly due to the arc welding function. Comparing with the arc discharge method before, the new method here needs no coat silicon probe with metal film in advance, which can greatly reduce the fabrication's difficulty. The fabricated carbon nanotube probe shows good property of higher aspect ratio and can more accurately reflect the true topography of silicon grating than silicon probe. Under the same image drive force, carbon nanotube probe had less indentation depth on soft triblock copolymer sample than silicon probe. This showed that carbon nanotube probe has lower spring constant and less damage to the scan sample than silicon probe. 展开更多
关键词 Carbon nanotube (CNT) atomic force microscope (AFM) probe Fabrication
下载PDF
THEORETICAL ANALYSIS AND EXPERIMENTAL STUDY OF CARBON NANOTUBE PROBE AND CONVENTIONAL ATOMIC FORCE MICROSCOPY PROBE ON SURFACE ROUGHNESS
13
作者 WANG Jinghe WANG Hongxiang XU Zongwei DONG Shen WANG Shiqian ZHANG Huali 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第5期62-64,共3页
In this paper, three different tips are employed, i.e., the carbon nanotube tip, monocrystalline silicon tip and silicon nitride tip. Resorting to atomic force microscope (AFM), they are used for measuring the surfa... In this paper, three different tips are employed, i.e., the carbon nanotube tip, monocrystalline silicon tip and silicon nitride tip. Resorting to atomic force microscope (AFM), they are used for measuring the surface roughness of indium tin oxide (ITO) film and the immunoglobulin G (IgG) proteins within the scanning area of 10 μm×10 μm and 0.5 μm×0.5 μm, respectively. Subsequently, the scanned surface of the ITO film and IgG proteins are analyzed by using fractal dimension. The results show that the ffactal dimension measured by carbon nanotube tip is biggest with the highest frequency components and the most microscopic information. Therefore, the carbon nanotube tip is the ideal measuring tool for measuring super-smooth surface, which will play a more and more important role in the high-resolution imaging field. 展开更多
关键词 atomic force microscope Carbon nanotube probes Fractal dimension
下载PDF
Studies of Atomic Structure and Physical Properties of Metal Clusters in MgO by HREM and Nano-probe Methods
14
作者 Nobuo Tanaka (Dept. of Applied Physics, School of Engineering, Nagoya University, Nagoya, 464-01, Japan) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1997年第4期265-270,共6页
Nanometer-sized metal clusters were prepared inside single crystalline MgO films by vacuum co-deposition of metals and MgO. The atomic structure was studied by high-resolution electron microscopy (HREM) and nm-area el... Nanometer-sized metal clusters were prepared inside single crystalline MgO films by vacuum co-deposition of metals and MgO. The atomic structure was studied by high-resolution electron microscopy (HREM) and nm-area electron diffraction. The size of the clusters is ranging from 1 nm to 3 nm without those larger than 5 nm, and most of them have definite epitaxial orientations with the MgO matrix films. The character of the composite films is very much useful for the studies of various kinds of physical properties with anisotroPy. The physical properties such as electric transport, magnetic, optical absorption, sintering and catalytic ones were thus measured on the same samples analyzed by HREM by using high sensitivity apparatus with interest of clarifying the retationship between the atomic structure and physical properties 展开更多
关键词 FIGURE NANO Studies of atomic Structure and Physical Properties of Metal Clusters in MgO by HREM and Nano-probe Methods HREM MGO
下载PDF
THEORY OF LC BIOMEMBRANE——A PROBE INTO SOFT CONDENSED MATTER PHYSICS
15
作者 Ouyang Zhongcan(Institute of Theoretical Physics, CAS) 《Bulletin of the Chinese Academy of Sciences》 1999年第3期154-157,共4页
Soft condensed-state physics is a disciplinary frontier of 20th-century physics. An interdiscipline in nature, it involves biology, chemistry and even pure mathematics. Taking the liquid crystal (LC) biomembrane as an... Soft condensed-state physics is a disciplinary frontier of 20th-century physics. An interdiscipline in nature, it involves biology, chemistry and even pure mathematics. Taking the liquid crystal (LC) biomembrane as an example, this article expounds the current development trend of this new and promising branch of contemporary physics. 展开更多
关键词 PRO LC THEORY OF LC BIOMEMBRANE A probe INTO SOFT CONDENSED MATTER physics
下载PDF
原子物理学的课程思政研究与实践
16
作者 靳奉涛 高城 +1 位作者 王小伟 戴佳钰 《大学物理》 2024年第9期54-62,共9页
原子物理学的发展联系着近代物理学史上许多著名的物理学家和故事,是一座富含思政素材的金矿.深入挖掘这些素材,使之融入到原子物理教学中,不但有利于学生加深知识的理解,也能培养学生科学的思维方式,对树立学生正确的人生观、世界观、... 原子物理学的发展联系着近代物理学史上许多著名的物理学家和故事,是一座富含思政素材的金矿.深入挖掘这些素材,使之融入到原子物理教学中,不但有利于学生加深知识的理解,也能培养学生科学的思维方式,对树立学生正确的人生观、世界观、科学观起到非常重要的作用.本文将思政素材进行合理的分类,根据其特点自然地融入到课堂授课中,使物理内容与思政元素有机地结合成一体,起到“春风化雨、润物无声”的作用,同时也拓展课程的深度和广度.从问卷调查、课上课下交流以及考试设计的实践来看,也证实了思政能够对课程教学起到升华的作用. 展开更多
关键词 原子物理 教学 课程思政
下载PDF
无磁光学非互易实验教学与设计 被引量:1
17
作者 王志平 李哲 +2 位作者 马阳成 吕亮 胡志家 《大学物理实验》 2024年第1期52-57,共6页
作为一种有趣的非线性光学效应,四波混频在众多领域有重要的应用。本文利用四波混频效应实现无磁的光学非互易,分别研究了信号光失谐量、泵浦光光功率和气体池温度等参量对信号光正向和反向传播时透过率的影响。实验结果表明改变这些参... 作为一种有趣的非线性光学效应,四波混频在众多领域有重要的应用。本文利用四波混频效应实现无磁的光学非互易,分别研究了信号光失谐量、泵浦光光功率和气体池温度等参量对信号光正向和反向传播时透过率的影响。实验结果表明改变这些参量可有效地调控正向透过率,而极低的反向透过率几乎不受影响。该文对于大学物理实验教学具有一定的参考价值。 展开更多
关键词 光学非互易 四波混频 热原子 物理实验教学
下载PDF
三维原子探针的电场结构模拟研究
18
作者 李依轩 刘俊亮 +2 位作者 王伟 于得洋 徐先东 《电子显微学报》 CAS CSCD 北大核心 2024年第2期173-179,共7页
本文针对目前世界上被广泛使用的局部电极原子探针的样品及局部电极几何结构,通过有限元方法,结合多物理场仿真技术,研究了局部电极与针状样品的距离z、样品尖端曲率半径ρ、局部电极的入口直径φ、厚度w、开口角度α和入口长度h等参数... 本文针对目前世界上被广泛使用的局部电极原子探针的样品及局部电极几何结构,通过有限元方法,结合多物理场仿真技术,研究了局部电极与针状样品的距离z、样品尖端曲率半径ρ、局部电极的入口直径φ、厚度w、开口角度α和入口长度h等参数对样品尖端附近的局部电场的影响。模拟结果表明:当z与φ的取值满足z/φ≥1时,既能在样品尖端得到较高的蒸发电场强度,又能降低局部电极对离子轨迹的影响;局部电极的厚度w和开口角度α的取值对样品尖端的电场影响较小;增大局部电极入口长度h的值有利于提高样品尖端电场强度;随着原子的蒸发(样品尖端曲率半径ρ增大),为维持原子蒸发所需的电场强度,施加在样品上的电压V与样品尖端的曲率半径ρ成正比,且所需维持的电场强度越高,施加的电压V越大。 展开更多
关键词 三维原子探针 局部电极 有限元模拟 电场结构 离子轨迹
下载PDF
基于大高宽比CD-AFM探针的设计与制备
19
作者 贺龙 李淑娴 +4 位作者 苗斌 李加东 陈颖 苗小浦 吴森 《压电与声光》 CAS 北大核心 2024年第3期409-413,428,共6页
针对传统原子力显微镜(AFM)探针和关键尺寸原子力显微镜(CD-AFM)探针受限于针尖有效扫描高度较低,无法对深沟槽和大悬垂侧壁结构进行精准扫描成像的问题,提出了一种大高宽比针尖结构的新型CDAFM探针设计与制备方案。开发的新型CD-AFM探... 针对传统原子力显微镜(AFM)探针和关键尺寸原子力显微镜(CD-AFM)探针受限于针尖有效扫描高度较低,无法对深沟槽和大悬垂侧壁结构进行精准扫描成像的问题,提出了一种大高宽比针尖结构的新型CDAFM探针设计与制备方案。开发的新型CD-AFM探针针尖有效高度为5.1~5.8μm,高宽比达到14,相较于传统硅基CD-AFM探针,其有效高度提升了约4倍。利用开发的探针完成了标称深度为2.3μm、深宽比为4.6的深沟槽样品测试。 展开更多
关键词 关键尺寸原子力显微镜探针 深沟槽 大悬垂侧壁 大高宽比 有效高度
下载PDF
上一页 1 2 48 下一页 到第
使用帮助 返回顶部