期刊文献+
共找到23,435篇文章
< 1 2 250 >
每页显示 20 50 100
Influence of axial stress on rockburst in deep tunnels: insight from model experiment
1
作者 YAN Yaofeng XIA Yuanyou +4 位作者 HUANG Jian LIN Manqing LIU Xiqi YAN Minjia ZHANG Hongwei 《Journal of Mountain Science》 SCIE CSCD 2024年第10期3536-3551,共16页
Frequent rockburst disasters in deep-buried engineering projects severely impact construction. To explore the influence of axial stress on rockburst in deep-buried tunnels, large-scale true triaxial rockburst experime... Frequent rockburst disasters in deep-buried engineering projects severely impact construction. To explore the influence of axial stress on rockburst in deep-buried tunnels, large-scale true triaxial rockburst experiments were conducted under four different axial stress ratio conditions (ηt, axial loading stress/vertical loading stress) using a self-developed true triaxial loading device under the condition of "pre-loading before excavation". The influence of axial stress on the rockburst process and failure characteristics in deep tunnels was studied using a combination of real-time video monitoring, rockburst debris sieving, and acoustic emission monitoring. The results indicate: (1) all four specimens subjected to different axial stress ratio loading conditions exhibited three stages of macroscopic failure: small particle ejection, flake spalling, and large fragment ejection. Ultimately, "V"-shaped notches appeared on both sides of the tunnel. (2) The failure stress, fragment volume, and fragment size distribution of the rockburst specimens exhibited a clear two-stage failure characteristic with increasing axial stress ratio. In the lower axial stress ratio stage (ηt ≤ 0.7), the increase in the axial stress ratio enhances lateral confinement, thereby increasing the crack initiation strength of the surrounding rock, inhibiting crack formation and propagation, and thus suppressing damage to the surrounding rock of the tunnel. In the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio makes the Poisson effect of the surrounding rock more pronounced, promoting the generation and propagation of cracks along the tunnel axis direction, thereby promoting damage to the surrounding rock. (3) Based on the analysis of acoustic emission parameters (fracture properties), it can be concluded that in the lower axial stress ratio stage (ηt ≤ 0.7), an increase in the axial stress ratio leads to a higher proportion of shear fracture in rockburst damage. Conversely, in the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio gradually reduces the proportion of shear fracture in rockburst damage. 展开更多
关键词 ROCKBURST EXPERIMENTS axial stress ratio Failure characteristics Fracture properties
原文传递
Effects of different orthokeratology lens designs on slowing axial length elongation in children with myopia
2
作者 Hai-Long Ni Xiang Chen +2 位作者 Du-Ya Chen Pei-Ke Hu Zhi-Yi Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第10期1843-1849,共7页
AIM:To elucidate whether differences exist in the impact on retarding the elongation of axial length(AL)among children with myopia when utilizing orthokeratology(ortho-k)lenses employing the corneal refractive therapy... AIM:To elucidate whether differences exist in the impact on retarding the elongation of axial length(AL)among children with myopia when utilizing orthokeratology(ortho-k)lenses employing the corneal refractive therapy(CRT)design versus those employing the vision shaping treatment(VST)design.METHODS:This retrospective clinical trial aimed to collect and analyze AL data from individuals who wore ortho-k lenses for three years.A total of 654 subjects were enrolled and prescribed one of the three specific brands of ortho-k lenses:CRT,Euclid,and Mouldway.The study’s primary focus was to compare the rates of AL elongation and myopic progression across these three brands of ortho-k lenses.RESULTS:In the 3-year follow-up,the AL elongation exhibited variations of 0.73±0.36 mm in the CRT lens group,0.59±0.37 mm in the Euclid lens group,and 0.63±0.38 mm in the Mouldway lens group.A noteworthy disparity emerged between the CRT and Mouldway groups(P<0.01),as well as between the CRT and Euclid groups(P<0.001).Additionally,it was observed that 32.1%of participants who wore CRT lenses experienced a decelerated progression of myopia,in contrast to 47.2%in the Euclid group and 44.4%in the Mouldway group.Statistical analyses revealed a statistically significant distinction between the CRT and Euclid groups(P<0.01),and similarly,the CRT group demonstrated a statistically significant difference when compared to the Mouldway group(P<0.05).CONCLUSION:Ortho-k lenses represent a pragmatic strategy for mitigating the advancement of myopia.In contradistinction to ortho-k lenses utilizing the CRT design,those employing the VST design exhibited a more favorable impact regarding retarding AL elongation. 展开更多
关键词 MYOPIA ORTHOKERATOLOGY design axial length
原文传递
Parametric resonance of axially functionally graded pipes conveying pulsating fluid
3
作者 Jie JING Xiaoye MAO +1 位作者 Hu DING Liqun CHEN 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第2期239-260,共22页
Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functio... Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functions of a simply supported beam.Via the direct multi-scale method,the response and stability boundary to the pulsating fluid velocity are solved analytically and verified by the differential quadrature element method(DQEM).The influence of Young's modulus gradient on the parametric resonance is investigated in the subcritical and supercritical regions.In general,the pipe in the supercritical region is more sensitive to the pulsating excitation.The nonlinearity changes from hard to soft,and the non-trivial equilibrium configuration introduces more frequency components to the vibration.Besides,the increasing Young's modulus gradient improves the critical pulsating flow velocity of the parametric resonance,and further enhances the stability of the system.In addition,when the temperature increases along the axial direction,reducing the gradient parameter can enhance the response asymmetry.This work further complements the theoretical analysis of pipes conveying pulsating fluid. 展开更多
关键词 pipe conveying fluid axially functionally graded supercritical resonance multi-scale method parametric resonance
下载PDF
Investigation of granite failure precursor under axial load using modified LSTM framework
4
作者 WANG Ya-lei XU Jin-ming 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第8期2930-2943,共14页
Granite is usually composed of quartz,biotite,feldspar,and cracks,and the variation characteristics of these components could reflect the deformation and failure process of rock well.Taking granite as an example,the v... Granite is usually composed of quartz,biotite,feldspar,and cracks,and the variation characteristics of these components could reflect the deformation and failure process of rock well.Taking granite as an example,the video camera was used to record the deformation and failure process of rock.The distribution of meso-components in video images was then identified.The meso-components of rock failure precursors were also discussed.Moreover,a modified LSTM(long short-term memory method)based on SSA(sparrow search algorithm)was proposed to estimate the change of meso-components of rock failure precursor.It shows that the initiation and expansion of cracks are mainly caused by feldspar and quartz fracture,and when the quartz and feldspar exit the stress framework,rock failure occurs;the second large increase of crack area and the second large decrease of quartz or feldspar area may be used as a precursor of rock failure;the precursor time of rock failure based on meso-scopic components is about 4 s earlier than that observed by the naked eye;the modified LSTM network has the strongest estimation ability for quartz area change,followed by feldspar and biotite,and has the worst estimation ability for cracks;when using the modified LSTM network to predict the precursors of rock instability and failure,quartz and feldspar could be given priority.The results presented herein may provide reference in the investigation of rock failure mechanism. 展开更多
关键词 GRANITE failure precursor axial load modified long short-term memory method
下载PDF
Impact of multifocal gas-permeable lens designs on short-term choroidal response, axial length, and retinal defocus profile
5
作者 Muteb Alanazi Patrick Caroline +1 位作者 Amane Alshamrani Maria Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期247-256,共10页
AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defoc... AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments. 展开更多
关键词 CHOROID gas-permeable contact lens retinal defocus axial length MYOPIA
原文传递
Particle residence time distribution and axial dispersion coefficient in a pressurized circulating fluidized bed by using multiphase particle-in-cell simulation
6
作者 Jinnan Guo Daoyin Liu +2 位作者 Jiliang Ma Cai Liang Xiaoping Chen 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第5期167-176,共10页
The particle residence time distribution(RTD)and axial dispersion coefficient are key parameters for the design and operation of a pressurized circulating fluidized bed(PCFB).In this study,the effects of pressure(0.1-... The particle residence time distribution(RTD)and axial dispersion coefficient are key parameters for the design and operation of a pressurized circulating fluidized bed(PCFB).In this study,the effects of pressure(0.1-0.6 MPa),fluidizing gas velocity(2-7 m·s^(-1)),and solid circulation rate(10-90 kg·m^(-2)·s^(-1))on particle RTD and axial dispersion coefficient in a PCFB are numerically investigated based on the multiphase particle-in-cell(MP-PIC)method.The details of the gas-solid flow behaviors of PCFB are revealed.Based on the gas-solid flow pattern,the particles tend to move more orderly under elevated pressures.With an increase in either fluidizing gas velocity or solid circulation rate,the mean residence time of particles decreases while the axial dispersion coefficient increases.With an increase in pressure,the core-annulus flow is strengthened,which leads to a wider shape of the particle RTD curve and a larger mean particle residence time.The back-mixing of particles increases with increasing pressure,resulting in an increase in the axial dispersion coefficient. 展开更多
关键词 Pressurized circulating fluidized bed MP-PIC method Residence time distribution axial dispersion coefficient
下载PDF
A numerical survey of parameters to reach ignition condition for axial compression of a large-sized field reversed configuration
7
作者 李宜霖 廖晖 +1 位作者 周海洋 孙玄 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期47-55,共9页
Field reversed configuration(FRC)is widely considered as an ideal target plasma for magnetoinertial fusion.However,its confinement and stability,both proportional to the radius,will deteriorate inevitably during radia... Field reversed configuration(FRC)is widely considered as an ideal target plasma for magnetoinertial fusion.However,its confinement and stability,both proportional to the radius,will deteriorate inevitably during radial compression.Hence,we propose a new fusion approach based on axial compression of a large-sized FRC.The axial compression can be made by plasma jets or plasmoids converging onto the axial ends of the FRC.The parameter space that can reach the ignition condition while preserving the FRC's overall quality is studied using a numerical model based on different FRC confinement scalings.It is found that ignition is possible for a large FRC that can be achieved with the current FRC formation techniques if compression ratio is greater than 50.A more realistic compression is to combine axial with moderate radial compression,which is also presented and calculated in this work. 展开更多
关键词 field reversed configuration magnetized target fusion axial compression
下载PDF
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
8
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
原文传递
A Tabletop Nano-CT Image Noise Reduction Network Based on 3-Dimensional Axial Attention Mechanism
9
作者 Huijuan Fu Linlin Zhu +5 位作者 ChunhuiWang Xiaoqi Xi Yu Han Lei Li Yanmin Sun Bin Yan 《Computers, Materials & Continua》 SCIE EI 2024年第7期1711-1725,共15页
Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process ... Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process is time-consuming.For 3D reconstruction data,this paper proposed a lightweight 3D noise reduction method for desktop-level Nano-CT called AAD-ResNet(Axial Attention DeNoise ResNet).The network is framed by theU-net structure.The encoder and decoder are incorporated with the proposed 3D axial attention mechanism and residual dense block.Each layer of the residual dense block can directly access the features of the previous layer,which reduces the redundancy of parameters and improves the efficiency of network training.The 3D axial attention mechanism enhances the correlation between 3D information in the training process and captures the long-distance dependence.It can improve the noise reduction effect and avoid the loss of image structure details.Experimental results show that the network can effectively improve the image quality of a 0.1-s exposure scan to a level close to a 3-s exposure,significantly shortening the sample scanning time. 展开更多
关键词 Deep learning tabletop Nano-CT image denoising 3D axial attention mechanism
下载PDF
Nonlinear dynamic modeling of planar moving Timoshenko beam considering non-rigid non-elastic axial effects
10
作者 M.ABBASI GAVARI M.R.HOMAEINEZHAD 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第3期479-496,共18页
Due to the importance of vibration effects on the functional accuracy of mechanical systems,this research aims to develop a precise model of a nonlinearly vibrating single-link mobile flexible manipulator.The manipula... Due to the importance of vibration effects on the functional accuracy of mechanical systems,this research aims to develop a precise model of a nonlinearly vibrating single-link mobile flexible manipulator.The manipulator consists of an elastic arm,a rotary motor,and a rigid carrier,and undergoes general in-plane rigid body motion along with elastic transverse deformation.To accurately model the elastic behavior,Timoshenko’s beam theory is used to describe the flexible arm,which accounts for rotary inertia and shear deformation effects.By applying Newton’s second law,the nonlinear governing equations of motion for the manipulator are derived as a coupled system of ordinary differential equations(ODEs)and partial differential equations(PDEs).Then,the assumed mode method(AMM)is used to solve this nonlinear system of governing equations with appropriate shape functions.The assumed modes can be obtained after solving the characteristic equation of a Timoshenko beam with clamped boundary conditions at one end and an attached mass/inertia at the other.In addition,the effect of the transverse vibration of the inextensible arm on its axial behavior is investigated.Despite the axial rigidity,the effect makes the rigid body dynamics invalid for the axial behavior of the arm.Finally,numerical simulations are conducted to evaluate the performance of the developed model,and the results are compared with those obtained by the finite element approach.The comparison confirms the validity of the proposed dynamic model for the system.According to the mentioned features,this model can be reliable for investigating the system’s vibrational behavior and implementing vibration control algorithms. 展开更多
关键词 planar moving Timoshenko beam non-rigid non-elastic axial effect as-sumed mode method(AMM) nonlinear motion analysis
下载PDF
Experimental Study on the Axial Compression Performance of Bamboo Scrimber Columns Embedded with Steel Reinforcing Bars
11
作者 Xueyan Lin Mingtao Wu +2 位作者 Guodong Li Nan Guo Lidan Mei 《Structural Durability & Health Monitoring》 EI 2024年第6期805-833,共29页
In this paper,a new type of bamboo scrimber column embedded with steel bars(rebars)was proposed,and the compression performance was improved by pre-embedding rebars during the preparation of the columns.The effects of... In this paper,a new type of bamboo scrimber column embedded with steel bars(rebars)was proposed,and the compression performance was improved by pre-embedding rebars during the preparation of the columns.The effects of the slenderness ratio and the reinforcement ratio on the axial compression performance of reinforced bamboo scrimber columns were studied by axial compression tests on 28 specimens.The results showed that the increase in the slenderness ratio had a significant negative effect on the axial compression performance of the columns.When the slenderness ratio increased from 19.63 to 51.96,the failure mode changed from strength failure to buckling failure,and the maximum bearing capacity decreased by 43.03%.The axial compression performance of the reinforced bamboo scrimber columns did not significantly improve at a slenderness ratio of 19.63,but the opposite was true at slenderness ratios of 36.95 and 51.96.When the reinforcement ratio increased from 0%to 4.52%,the bearing capacity of those with a slenderness ratio of 51.96 increased by up to 16.99%,and the stiffness and ductility were also improved.Finally,based on existing specifications,two modification parameters,the overall elastic modulus Ec and the combined strength fcc,were introduced to establish a calculation method for the bearing capacity of the reinforced bamboo scrimber columns.The calculation results were compared with the test results,and the results showed that the proposed calculation models can more accurately predict the bearing capacity. 展开更多
关键词 Bamboo scrimber column steel bar axial compression performance theoretical model
下载PDF
The Method of Thermoelectric Energy Generations Based on the Axial and Radial Flux Electromagnetic Inductions*
12
作者 Hiroshi Uechi Lisa Uechi Schun T. Uechi 《World Journal of Engineering and Technology》 2024年第3期715-730,共16页
The traditional thermoelectric energy conversion techniques are explained in detail in terms of the axial flux electromagnetic (AFE) and the radial flux electromagnetic (RFE) inductions, and applications to heat engin... The traditional thermoelectric energy conversion techniques are explained in detail in terms of the axial flux electromagnetic (AFE) and the radial flux electromagnetic (RFE) inductions, and applications to heat engines for the energy-harvesting technologies are discussed. The idea is induced by the analysis of thermomechanical dynamics (TMD) for a nonequilibrium irreversible thermodynamic system of heat engines (a drinking bird, a low temperature Stirling engine), resulting in thermoelectric energy generation different from conventional heat engines. The mechanism of thermoelectric energy conversion can be categorized as the axial flux generator (AFG) and the radial flux generator (RFG). The axial flux generator is helpful for low mechanoelectric energy conversion and activations of waste heat from macroscopic energy generators, such as wind, geothermal, thermal, nuclear power plants and heat-dissipation lines, and the device contributes to solving environmental problems to maintain clean and sustainable energy as one of the energy harvesting technologies. 展开更多
关键词 axial Flux and Radial Flux Generators Thermomechanical Dynamics (TMD) Thermoelectric Energy Conversions
下载PDF
Axial load-share ratio testing to assess the healing of open tibial fractures treated with the Taylor Spatial Frame
13
作者 Zhao Liu Jin-Wei Liu +7 位作者 Qi-Jun Zhao Hong-Zhou Li Ning-Ning Zhang Hong-Liang Zhang Yu Gou Xun Sun Tao Zhang Wei-Guo Xu 《Biomedical Engineering Communications》 2024年第3期23-30,共8页
Background:The Taylor Spatial Frame(TSF)has gained popularity among orthopedic surgeons for treating open fractures.However,a key challenge is the timely and safe removal of the frame.This study assessed the efficacy ... Background:The Taylor Spatial Frame(TSF)has gained popularity among orthopedic surgeons for treating open fractures.However,a key challenge is the timely and safe removal of the frame.This study assessed the efficacy and safety of axial load-share ratio(ALSR)testing to evaluate callus healing strength after TSF treatment of open tibial fractures.Methods:A retrospective case-control study was conducted,analyzing 180 adult patients with open tibial fractures treated at Tianjin Hospital’s Orthopedic Limb Correction Unit between August 2019 and August 2022.All patients underwent TSF external fixation surgery,and were divided into two groups based on ALSR testing.Group I(92 patients)underwent ALSR testing,with frame removal if the test value fell below 5%.Traditional methods were used for fixator removal guidance in Group II(88 patients).Clinical outcomes,including fixation duration,complications after fixator removal,and Johner-Wruhs functional scores,were compared between the two groups.Results:The groups showed no statistically significant differences(P>0.05)in sex,age,injury side,body mass index,surgery timing,or fracture type.Group I had a significantly shorter fixation duration(25.85±5.57 weeks)compared to Group II(31.82±6.98 weeks)(P<0.05).Following fixator removal,Group I demonstrated superior Johner-Wruhs scores compared to Group II,indicating better outcomes(P<0.05).Complication rates did not differ significantly between the groups at the last follow-up(P>0.05).Conclusion:Regular postoperative ALSR testing could safely and effectively guide TSF removal following open tibial fracture treatment.This method significantly reduced fixation duration compared to traditional guidance methods while maintaining efficacy and safety. 展开更多
关键词 tibial fractures external fixators fracture healing axial load
下载PDF
Extra-Axial Anaplastic Pleomorphic Xanthoastrocytoma Mimicking Meningioma: A Case Report with Literature Review
14
作者 Kaoutar Stitou Ilias Zahir +5 位作者 Oualid Mohammed Hmamouche Marouane Hammoud Faycal Lakhdar Mohammed Benzagmout Khalid Chakour Mohammed El Faiz Chaoui 《Open Journal of Modern Neurosurgery》 2024年第3期203-211,共9页
Background: A number of meningeal neoplastic lesions may radiologically and clinically simulate meningioma, include hemangiopericytomas, solitary fibrous tumors, schwannomas, hematolymphoid lesions, metastases, and ot... Background: A number of meningeal neoplastic lesions may radiologically and clinically simulate meningioma, include hemangiopericytomas, solitary fibrous tumors, schwannomas, hematolymphoid lesions, metastases, and others very rarely, also may clinically mimic meningiomas. Case Description: We present the case of A 28-year-old male patient, with no notable medical history, who presented with worsening headaches for 3 months, imbalance, and visual deficits, An initial MRI revealed extra-axial lesion involving the right Parieto-occipital, The tumor was hypointense on T1-weighted MR images, hyperintense signals on T2-weightedMR images, and heterogeneously enhanced suggestive of a meningioma, total resection was achieved, and the histopathological analysis confirmed the diagnosis of an angioblastic meningioma. However, 15 months later, the patient presented with the same initial visual complaints. A subsequent MRI showed lesion recurrence, leading to a second surgical intervention. The histopathological analysis confirmed the diagnosis of an anaplastic xanthoastrocytoma. Conclusion: This represents an unusual location for an anaplastic pleomorphic xanthoastrocytoma, which should broaden the differential diagnosis of extra-axial lesions. 展开更多
关键词 Anaplastic Features BRAF Extra-axial High Mitotic Rate High Proliferation Index MENINGEAL Pleomorphic Xanthoastrocytoma
下载PDF
基于轴-Transformer的医学图像分割模型Axial-TransUNet
15
作者 刘文科 刘琳 +1 位作者 韩子逸 张媛媛 《现代信息科技》 2024年第16期28-33,共6页
针对TransUNet中Transformer自注意力机制计算复杂度高、捕获位置信息能力不足的问题,提出一种基于轴向注意力机制的医学图像分割网络Axial-TransUNet。该网络在保留TransUNet网络编码器、解码器以及跳跃连接的基础上,使用基于轴向注意... 针对TransUNet中Transformer自注意力机制计算复杂度高、捕获位置信息能力不足的问题,提出一种基于轴向注意力机制的医学图像分割网络Axial-TransUNet。该网络在保留TransUNet网络编码器、解码器以及跳跃连接的基础上,使用基于轴向注意力机制的残差轴向注意力块代替TransUNet的Transformer层。实验结果表明,在多个医学数据集上,相较于TransUNet等其他医学图像分割网络,Axial-TransUNet的Dice系数、交并比IoU有更好的表现。与TransUNet相比,Axial-TransUNet网络的参数量与浮点运算数(FLOPs)分别降低14.9%和30.5%。可见,Axial-TransUNet有效降低了模型复杂度,并增强了模型捕获位置信息的能力。 展开更多
关键词 医学图像分割 卷积神经网络 位置信息 计算复杂度 轴向注意力机制
下载PDF
Case Series of 11 Patients Operated with Axial-LIF Technique in a Single Center in Mexico
16
作者 Alfonso Vega Sosa Sergio Ivan Reyna Heredia +10 位作者 Apolinar De la Luz Laguna Ivanka Berenice Moreno Villa Marlene de la Peña Gutiérrez Ramiro López Elizalde Cuauhtémoc Gil Ortiz Andres Jaime Aguirre Ivan Alejandro Mendez Guerrero Edwin Rolando Sanchez Vallejo Alejandra Grisel Mendoza Zuñiga Ricardo Cazares Mejía Carlos Erosa Velázquez 《Open Journal of Modern Neurosurgery》 2023年第3期129-136,共8页
Introduction: Since the earliest description of spinal fusion in 1911 and later by Dr. Fred H. Albee, it has become one of the most commonly performed procedures by orthopedist and neurosurgeons. The spinal fusion is ... Introduction: Since the earliest description of spinal fusion in 1911 and later by Dr. Fred H. Albee, it has become one of the most commonly performed procedures by orthopedist and neurosurgeons. The spinal fusion is now used to treat a variety of indications, such as traumatic injuries, deformities, primary and secondary tumors, infections and degenerative conditions of the spine. The risk of iatrogenic injury during traditional anterior, posterior, and transforaminal open fusion surgery is significant. The axial lumbar interbody fusion (Axia-LIF) is a minimal invasive technique which uses the retroperitoneumpresacral anatomical corridor to fuse the lumbar vertebral bodies L4-L5-S1 avoiding manipulation of the annular ligament, paravertebral muscles and facet joints. Methods: In this retrospective series, we report all the cases made in the Centro Medico Naval in México City in two years. A total of eleven patients with degenerative disc disease and spondylolisthesis underwent Axia-LIF one or two level systems with a 36 months clinical and radiographic follow-up. The outcomes included Oswestry Disability Index (ODI) score and leg/back pain severity. Radiographic outcome was evaluated with dynamics and orthogonal x-ray, as well as lumbosacral tomography scan to evaluate fusion status. Results: Nine patients underwent Axia-LIF one level system (L5-S1) and the rest two levels system (L4-S1). Ten patients were fixated with transpedicular percutaneous screws and one with facets joints screws. No intraoperative complications were reported. The mean back pain severity improved 57% in 12 months, and the mean leg pain severity improved 50% in the same time (P < 0.001). Mean ODI scores improved 58%, from 60% ± 16% at baseline to 25% ± 8% at twelve months (P < 0.001). At one year, a patient developed pseudoarthrosis that required posterolateral arthrodesis with transpedicular percutaneous screws. At 36 months monitoring, 100% patients presented a total interbody fusion in the tomography scans. At final follow-up, mean ODI score improved 73% (16% ± 5%;P < 0.001). Conclusion: The Axial Lumbar Interbody Fusion has demonstrated to be a safe treatment for the degenerative disc disease L5-S1 and L4-S1. The patients who underwent one or two level Axia-LIF showed an improvement in ODI and back/leg pain severity scores, with no intraoperative complications. The use of this technique and its indications are still in controversy;nevertheless, its use has increased as for pathologies such as spondylitis, scoliosis, patients with residual pain with previous surgeries. We recommended complementary pedicular fixation to avoid complications and improved interbody fusion. 展开更多
关键词 Spine Surgery axial-LIF Procedure axial-LIF CMN 20 de Noviembre Spinal Fusion Centro Médico Naval
下载PDF
Advances on Axial Coordination Design of Single‑Atom Catalysts for Energy Electrocatalysis:A Review 被引量:3
17
作者 Linjie Zhang Na Jin +4 位作者 Yibing Yang Xiao‑Yong Miao Hua Wang Jun Luo Lili Han 《Nano-Micro Letters》 SCIE EI CAS CSCD 2023年第12期188-230,共43页
Single-atom catalysts(SACs)have garnered increasingly growing attention in renewable energy scenarios,especially in electrocatalysis due to their unique high efficiency of atom utilization and flexible electronic stru... Single-atom catalysts(SACs)have garnered increasingly growing attention in renewable energy scenarios,especially in electrocatalysis due to their unique high efficiency of atom utilization and flexible electronic structure adjustability.The intensive efforts towards the rational design and synthesis of SACs with versatile local configurations have significantly accelerated the development of efficient and sustainable electrocatalysts for a wide range of electrochemical applications.As an emergent coordination avenue,intentionally breaking the planar symmetry of SACs by adding ligands in the axial direction of metal single atoms offers a novel approach for the tuning of both geometric and electronic structures,thereby enhancing electrocatalytic performance at active sites.In this review,we briefly outline the burgeoning research topic of axially coordinated SACs and provide a comprehensive summary of the recent advances in their synthetic strategies and electrocatalytic applications.Besides,the challenges and outlooks in this research field have also been emphasized.The present review provides an in-depth and comprehensive understanding of the axial coordination design of SACs,which could bring new perspectives and solutions for fine regulation of the electronic structures of SACs catering to high-performing energy electrocatalysis. 展开更多
关键词 Single-atom catalyst axial coordination Synthetic strategy Electrocatalytic application
下载PDF
Axial length,vitreoretinal pathology,and anterior chamber depth can predict postoperative refractive outcomes in phacovitrectomy/silicone oil removal 被引量:2
18
作者 Xu Chen He Zhao +6 位作者 Jia-Yun Ren Lu Wang Jun-Li Wan Bo Liu Nan Wu Xi Liu Yong Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第4期554-562,共9页
AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.M... AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.METHODS:The study is a retrospective,case-series study.Totally 301 eyes of 301 patients undergoing combined PPV/SOR with cataract surgery were enrolled.Eligible individuals were separated into four groups according to their preoperative diagnoses:silicone oil-filled eyes after PPV(group 1),epiretinal membrane(group 2),macular hole(group 3),and primary retinal detachment(RD;group 4).The variables af fecting postoperative refractive outcomes were analyzed,including age,gender,preoperative best-corrected visual acuity(BCVA),axial length(AL),keratometry average,anterior chamber depth(ACD),intraocular tamponade,and vitreoretinal pathology.The outcome measurements include the mean refractive PE and the proportions of eyes with a PE within±0.50 diopter(D)and±1.00 D.RESULTS:For all patients,the mean PE was-0.04±1.17 D,and 50.17%of patients(eyes)had a PE within±0.50 D.There was a significant difference in refractive outcomes among the four groups(P=0.028),with RD(group 4)showing the least favorable refractive outcome.In multivariate regression analysis,only AL,vitreoretinal pathology,and ACD were strongly associated with PE(all P<0.01).Univariate analysis revealed that longer eyes(AL>26 mm)and a deeper ACD were correlated with hyperopic PE,and shorter eyes(AL<26 mm)and a shallower ACD were correlated with myopic PE.CONCLUSION:RD patients have the least favorable refractive outcome.AL,vitreoretinal pathology,and ACD are strongly associated with PE in the combined surgery.These three factors affect refractive outcomes and thus can be used to predict a better postoperative refractive outcome in clinical practice. 展开更多
关键词 axial length vitreoretinal pathology anterior chamber depth intraocular lens pars plana vitrectomy silicone oil removal CATARACT combined surgery refractive error intraocular tamponade
原文传递
Simultaneous resonance of an axially moving ferromagnetic thin plate under a line load in a time-varying magnetic field 被引量:1
19
作者 Xie Mengxue Hu Yuda Xu Haoran 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第4期951-963,共13页
In this paper,the simultaneous resonance of a ferromagnetic thin plate in a time-varying magnetic field,having axial speed and being subjected to a periodic line load,is studied.Based on the large deflection theory of... In this paper,the simultaneous resonance of a ferromagnetic thin plate in a time-varying magnetic field,having axial speed and being subjected to a periodic line load,is studied.Based on the large deflection theory of thin plates and electromagnetic field theory,the nonlinear vibration differential equation of the plate is obtained by using the Hamilton′s principle and the Galerkin method.Then the boundary condition in which the longer opposite sides are clamped and hinged is considered.The dimensionless nonlinear differential equations are solved by using the method of multiple scales,and the analytical solution is given.In addition,the stability analysis is also carried out by using Lyapunov stability theory.Through numerical analysis,the variation curves of system resonance amplitude with frequency tuning parameter,magnetic field strength and external excitation amplitude are obtained.Different parameters that have significant effects on the response of the system,such as the thickness,the axial velocity,the magnetic field intensity,the position,and the frequency of external excitation,are considered and analyzed.The results show that the system has multiple solution regions and obvious nonlinear coupled characteristics. 展开更多
关键词 ferromagnetic thin plate time-varying magnetic field simultaneous resonance axially moving line load
下载PDF
Cavitation recognition of axial piston pumps in noisy environment based on Grad-CAM visualization technique 被引量:1
20
作者 Qun Chao Xiaoliang Wei +2 位作者 Jianfeng Tao Chengliang Liu Yuanhang Wang 《CAAI Transactions on Intelligence Technology》 SCIE EI 2023年第1期206-218,共13页
The cavitation in axial piston pumps threatens the reliability and safety of the overall hydraulic system.Vibration signal can reflect the cavitation conditions in axial piston pumps and it has been combined with mach... The cavitation in axial piston pumps threatens the reliability and safety of the overall hydraulic system.Vibration signal can reflect the cavitation conditions in axial piston pumps and it has been combined with machine learning to detect the pump cavitation.However,the vibration signal usually contains noise in real working conditions,which raises concerns about accurate recognition of cavitation in noisy environment.This paper presents an intelligent method to recognise the cavitation in axial piston pumps in noisy environment.First,we train a convolutional neural network(CNN)using the spectrogram images transformed from raw vibration data under different cavitation conditions.Second,we employ the technique of gradient-weighted class activation mapping(Grad-CAM)to visualise class-discriminative regions in the spectrogram image.Finally,we propose a novel image processing method based on Grad-CAM heatmap to automatically remove entrained noise and enhance class features in the spectrogram image.The experimental results show that the proposed method greatly improves the diagnostic performance of the CNN model in noisy environments.The classification accuracy of cavitation conditions increases from 0.50 to 0.89 and from 0.80 to 0.92 at signal-to-noise ratios of 4 and 6 dB,respectively. 展开更多
关键词 axial piston pump cavitation recognition CNN Grad-CAM spectrogram image
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部