A 499.8 MHz SOLEIL-type superconducting cavity was simulated and designed for the first time in this paper.The higher-order mode(HOM)properties of the cavity were investigated.Two kinds of coaxial HOM couplers were de...A 499.8 MHz SOLEIL-type superconducting cavity was simulated and designed for the first time in this paper.The higher-order mode(HOM)properties of the cavity were investigated.Two kinds of coaxial HOM couplers were designed.Using 4 L-type and 4 T-type HOM couplers,the longitudinal impedance and the transverse impedances were suppressed to below 3 kΩand 30 kΩ/m,respectivly.The HOM damping requirements of Hefei Advanced Light Facility(HALF)were satisfied.This paper conducted an in-depth study on the radio frequency(RF)design,multipacting optimization,and thermal analysis of these coaxial couplers.Simulation results indicated that under operating acceleration voltage,the optimized couplers does not exhibit multiplicating or thermal breakdown phenomena.The cavity has the potential to reach a higher acceleration gradient.展开更多
The China Spallation Neutron Source(CSNS) upgrade project(CSNS-Ⅱ) aims to enhance the beam power from 100 to 500 kW. A dual-harmonic accelerating method has been adopted to alleviate the stronger space-charge effect ...The China Spallation Neutron Source(CSNS) upgrade project(CSNS-Ⅱ) aims to enhance the beam power from 100 to 500 kW. A dual-harmonic accelerating method has been adopted to alleviate the stronger space-charge effect in rapid-cycling synchrotrons owing to the increased beam intensity. To satisfy the requirements of dual-harmonic acceleration, a new radiofrequency(RF) system based on a magnetic alloy-loaded cavity is proposed. This paper presents design considerations and experimental results regarding the performance evaluation of the proposed RF system through high-power tests and beam commissioning. The test results demonstrate that the RF system satisfies the desired specifications and affords significant benefits for CSNS-Ⅱ.展开更多
A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and p...A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and provided a deflecting voltage of 4.2 MV with an input power of 2.5 MW.Bunch length diagnoses of electron beams with energies up to 39 MeV have been performed.In this article,the RF design of the cavity using HFSS,fabrication,and RF test processes are reviewed.High-power operation with accelerated beams and calibration of the deflecting voltage are also presented.展开更多
The 500 MHz 5-cell superconducting RF(SRF) cavity was designed aiming to be a candidate cavity for high current accelerators. A copper prototype cavity and a niobium cavity were fabricated at SINAP in 2012. In order t...The 500 MHz 5-cell superconducting RF(SRF) cavity was designed aiming to be a candidate cavity for high current accelerators. A copper prototype cavity and a niobium cavity were fabricated at SINAP in 2012. In order to ensure these cavities get the desired frequency and a good field flatness higher than 98%, frequency control was implemented in the manufacturing process and pre-tuning has been done using a simple pre-tuning frame based on the bead-pull pre-tuning method. Then, TM010-π mode frequency within 5 kHz from the target frequency was achieved and the field flatness reached 98.9% on the copper prototype cavity. Finally, the same procedure was applied to the niobium cavity to obtain a field flatness better than 98% which benefited the cavity performance in the vertical testing.展开更多
SSC-LINAC is as a linear injector for the cyclotron accelerator SSC. DTL2 RF cavity is designed to install in SSC-LINAC intermediate energy beam line, whose working frequency is 53.667 MHz and working mode is cw.DTL2 ...SSC-LINAC is as a linear injector for the cyclotron accelerator SSC. DTL2 RF cavity is designed to install in SSC-LINAC intermediate energy beam line, whose working frequency is 53.667 MHz and working mode is cw.DTL2 cavity adopts drift tube structure with IH-mode, which having high shunt impedance, high quality, etc.展开更多
This study established a novel method for the simultaneous detection of two-component gases.Radio frequency(RF)white noise disturbance laser current and wavelength modulation were simultaneously used to improve the of...This study established a novel method for the simultaneous detection of two-component gases.Radio frequency(RF)white noise disturbance laser current and wavelength modulation were simultaneously used to improve the off-axis integrated cavity output spectroscopy technique,and a high-precision dual modulation OA-ICOS(RF-WM-OA-ICOS)system was established.The two laser beams were coupled into one laser beam that was applied incident to the cavity of RF-WM-OA-ICOS system.The second harmonic signals of CH_(4)and CO_(2)gas simultaneously appeared in the rising or falling edge of a triangular wave.This method was used to measure CH_(4)and CO_(2)with different concentrations.The results indicated that the proposed system has high stability and can accurately and simultaneously measure the concentrations of CH_(4)and CO_(2),with an optimal integration time of 220 s.The minimum detection limit was 10 ppb for CH_(4)and 1.5 ppm for CO_(2).The corresponding noise equivalent absorption sensitivity values were calculated as 2.67×10^(-13)cm^(-1)·Hz^(-1/2)and 5.18×10^(-11)cm^(-1)·Hz^(-1/2),respectively.The proposed dual-component gas simultaneous detection method can also be used for high-precision simultaneous detection of other gases.Therefore,this study may serve as a reference for developing portable multicomponent gas analyzers.展开更多
In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of r...In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of radio frequency(RF) front end and high speed data acquisition board.The beam position resolution in the CBPM signal processing system is superior to 1μm.Two signal processing algorithms,fast Fourier transform(FFT) and digital down converter(DDC),are evaluated offline using MATLAB platform,and both can be used to achieve,the CW input signal,position resolutions of 0.31μm and 0.10μm at -16 dBm.The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement,reaching the position resolution of 0.49μm due to truncation error.The whole system works well and the performance meets design target.展开更多
In a cyclotron,the RF cavity is the key device to accelerate ions.The RF cavity design for the 100MeV H^- cyclotron is very complex since the space is narrow and the Dee voltage is 60kV at the center and 120kV at the ...In a cyclotron,the RF cavity is the key device to accelerate ions.The RF cavity design for the 100MeV H^- cyclotron is very complex since the space is narrow and the Dee voltage is 60kV at the center and 120kV at the extraction region.CST MICROWAVE STUDIO is used in the design,and a real model has been made.The test result on the model is in good agreement with the simulation result.展开更多
The tolerances of the manufacture and installation errors and Dees deformation caused by gravity in RF cavity of CYCIAE-100 are investigated.Both the analytic treatment and numerical simulation are carried out to give...The tolerances of the manufacture and installation errors and Dees deformation caused by gravity in RF cavity of CYCIAE-100 are investigated.Both the analytic treatment and numerical simulation are carried out to give the tolerance of the manufacture and installation errors which disturb the radial and vertical motion of the beam.The Dees deformation caused by gravity leads to axial misalignment of the Dees and then induces the build-up of coherent axial oscillations.However,the calculated results show that the deformation of our Dees is acceptable.展开更多
基金supported by the Fundamental Research Funds for the Central Universities(WK2310000098).
文摘A 499.8 MHz SOLEIL-type superconducting cavity was simulated and designed for the first time in this paper.The higher-order mode(HOM)properties of the cavity were investigated.Two kinds of coaxial HOM couplers were designed.Using 4 L-type and 4 T-type HOM couplers,the longitudinal impedance and the transverse impedances were suppressed to below 3 kΩand 30 kΩ/m,respectivly.The HOM damping requirements of Hefei Advanced Light Facility(HALF)were satisfied.This paper conducted an in-depth study on the radio frequency(RF)design,multipacting optimization,and thermal analysis of these coaxial couplers.Simulation results indicated that under operating acceleration voltage,the optimized couplers does not exhibit multiplicating or thermal breakdown phenomena.The cavity has the potential to reach a higher acceleration gradient.
基金This work was supported by funds from the National Natural Science Foundation of China(Nos.11875270,U1832210,12205317)Youth Innovation Promotion Association CAS(No.2018015)Guangdong Basic and Applied Basic Research Foundation(No.2019B1515120046).
文摘The China Spallation Neutron Source(CSNS) upgrade project(CSNS-Ⅱ) aims to enhance the beam power from 100 to 500 kW. A dual-harmonic accelerating method has been adopted to alleviate the stronger space-charge effect in rapid-cycling synchrotrons owing to the increased beam intensity. To satisfy the requirements of dual-harmonic acceleration, a new radiofrequency(RF) system based on a magnetic alloy-loaded cavity is proposed. This paper presents design considerations and experimental results regarding the performance evaluation of the proposed RF system through high-power tests and beam commissioning. The test results demonstrate that the RF system satisfies the desired specifications and affords significant benefits for CSNS-Ⅱ.
基金This work was supported by the National Natural Science Foundation of China(No.11922504).
文摘A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and provided a deflecting voltage of 4.2 MV with an input power of 2.5 MW.Bunch length diagnoses of electron beams with energies up to 39 MeV have been performed.In this article,the RF design of the cavity using HFSS,fabrication,and RF test processes are reviewed.High-power operation with accelerated beams and calibration of the deflecting voltage are also presented.
文摘The 500 MHz 5-cell superconducting RF(SRF) cavity was designed aiming to be a candidate cavity for high current accelerators. A copper prototype cavity and a niobium cavity were fabricated at SINAP in 2012. In order to ensure these cavities get the desired frequency and a good field flatness higher than 98%, frequency control was implemented in the manufacturing process and pre-tuning has been done using a simple pre-tuning frame based on the bead-pull pre-tuning method. Then, TM010-π mode frequency within 5 kHz from the target frequency was achieved and the field flatness reached 98.9% on the copper prototype cavity. Finally, the same procedure was applied to the niobium cavity to obtain a field flatness better than 98% which benefited the cavity performance in the vertical testing.
文摘SSC-LINAC is as a linear injector for the cyclotron accelerator SSC. DTL2 RF cavity is designed to install in SSC-LINAC intermediate energy beam line, whose working frequency is 53.667 MHz and working mode is cw.DTL2 cavity adopts drift tube structure with IH-mode, which having high shunt impedance, high quality, etc.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.62005108 and 62205134)the National Key Research and Development Program of China(Grant No.2022YFC2807701)the Natural Science Foundation of the Higher Education Institutions of Jiangsu Province,China(Grant Nos.20KJB140009 and 21KJB140008)。
文摘This study established a novel method for the simultaneous detection of two-component gases.Radio frequency(RF)white noise disturbance laser current and wavelength modulation were simultaneously used to improve the off-axis integrated cavity output spectroscopy technique,and a high-precision dual modulation OA-ICOS(RF-WM-OA-ICOS)system was established.The two laser beams were coupled into one laser beam that was applied incident to the cavity of RF-WM-OA-ICOS system.The second harmonic signals of CH_(4)and CO_(2)gas simultaneously appeared in the rising or falling edge of a triangular wave.This method was used to measure CH_(4)and CO_(2)with different concentrations.The results indicated that the proposed system has high stability and can accurately and simultaneously measure the concentrations of CH_(4)and CO_(2),with an optimal integration time of 220 s.The minimum detection limit was 10 ppb for CH_(4)and 1.5 ppm for CO_(2).The corresponding noise equivalent absorption sensitivity values were calculated as 2.67×10^(-13)cm^(-1)·Hz^(-1/2)and 5.18×10^(-11)cm^(-1)·Hz^(-1/2),respectively.The proposed dual-component gas simultaneous detection method can also be used for high-precision simultaneous detection of other gases.Therefore,this study may serve as a reference for developing portable multicomponent gas analyzers.
基金Supported by National Natural Science Foundaion of China(No.11075198)
文摘In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of radio frequency(RF) front end and high speed data acquisition board.The beam position resolution in the CBPM signal processing system is superior to 1μm.Two signal processing algorithms,fast Fourier transform(FFT) and digital down converter(DDC),are evaluated offline using MATLAB platform,and both can be used to achieve,the CW input signal,position resolutions of 0.31μm and 0.10μm at -16 dBm.The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement,reaching the position resolution of 0.49μm due to truncation error.The whole system works well and the performance meets design target.
文摘In a cyclotron,the RF cavity is the key device to accelerate ions.The RF cavity design for the 100MeV H^- cyclotron is very complex since the space is narrow and the Dee voltage is 60kV at the center and 120kV at the extraction region.CST MICROWAVE STUDIO is used in the design,and a real model has been made.The test result on the model is in good agreement with the simulation result.
文摘The tolerances of the manufacture and installation errors and Dees deformation caused by gravity in RF cavity of CYCIAE-100 are investigated.Both the analytic treatment and numerical simulation are carried out to give the tolerance of the manufacture and installation errors which disturb the radial and vertical motion of the beam.The Dees deformation caused by gravity leads to axial misalignment of the Dees and then induces the build-up of coherent axial oscillations.However,the calculated results show that the deformation of our Dees is acceptable.