Confronting the severe health threats and environmental impacts of Cr(Ⅵ) in aquatic environments demands innovative and effective remediation approaches. In this study, Graphene oxide(GO)-decorated poly(dimethyl amin...Confronting the severe health threats and environmental impacts of Cr(Ⅵ) in aquatic environments demands innovative and effective remediation approaches. In this study, Graphene oxide(GO)-decorated poly(dimethyl amino ethyl methacrylate)(PDMAEMA) brush nanocomposites(GOP1, GOP2, GOP3, and GOP4) were fabricated using atom transfer radical polymerization(ATRP) by the “graft from” method.The resulting nanocomposites were utilized for removing Cr(Ⅵ) with good adsorption performance due to the electrostatic interaction of protonated nitrogen groups in the brush chains with negatively charged particles in the solution. The kinetic model of pseudo-second-order best represented the contaminants' adsorption characteristics. The Weber-Morris model further indicated that surface adsorption and intraparticle diffusion mechanisms primarily controlled the adsorption procedure. Additionally, the Langmuir and Temkin isotherm models were found to most accurately represent the adsorption characteristics of the pollutants on the nanocomposites, and GOP4 can achieve the maximum adsorption capacity of 164.4 mg·g^(-1). The adsorbents' capacity maintains above 85% after five cycles of adsorption-desorption. The nanocomposites in this study demonstrate promising potential for eliminating Cr(Ⅵ) from aqueous solutions.展开更多
Herein,binary mixed brushes consisting of poly(2-methyl-2-oxazoline)(PMOXA)and poly(2-(dimethylamine)ethyl methacrylate)(PDMAEMA)with different chain lengths were fabricated by successive grafting of NH_(2)-terminated...Herein,binary mixed brushes consisting of poly(2-methyl-2-oxazoline)(PMOXA)and poly(2-(dimethylamine)ethyl methacrylate)(PDMAEMA)with different chain lengths were fabricated by successive grafting of NH_(2)-terminated PMOXA and SH-terminated PDMAEMA onto polydopamine-anchored substrates.The mixed-brush coating was characterized by variable-angle spectroscopic ellipsometry,X-ray photoelectron spectroscopy,Fourier transform infrared spectroscopy,zeta potential measurements,water contact angle,and atomic force microscopy.The mixed brushes showed tunable surface charge,wettability,and surface roughness,depending on the degree of PDMAEMA swelling under varying pH and ionic strength(Ⅰ).Then the adsorption behaviors of pepsin,bovine serum albumin(BSA),γ-globulin,and lysozyme,four very different proteins with regard to isoelectric point,on the mixed brushes coating were studied by using fluorescence microscopy and surface plasmon resonance.When the chain length of PDMAEMA was about twice as long as PMOXA,the mixed brushes not only had high adsorption capacity for pepsin,BSA,and y-globulin but also had a desorption efficiency of 86.9%,87.1%,and 93.5%,respectively.It is explained that electrostatic attraction between the protonated PDMAEMA and positively charged acidic proteins(pepsin and BSA,whose isoelectric points were below the pK_(a) of PDMAEMA)would drive the intensive adsorption(at pH 3,I=10^(-3)mol·L^(-1)for pepsin,and pH 5,I=10^(-5)mol·L^(-1)for BSA),while desorption was dominated by the hydrophilic PMOXA when PDMAEMA was shrinking(at pH 7,I=10^(-1)mol·L^(-1)for pepsin,and pH 9,I=10^(-1)mol·L^(-1)for BSA).Furthermore,the isoelectric precipitation led to the adsorption of neutral protein(γ-globulin,whose isoelectric point was near the pK_a of PDMAEMA)at pH 7,I=10^(-5)mol·L^(-1),while electrostatic repulsion and antifouling PMOXA triggered the desorption of y-globulin at pH 3,I-10^(-1)mol·L^(-1).However,alkaline protein(lysozyme,whose isoelectric point was higher than the pK_(a) of PDMAEMA)exhibited slight adsorption on PMOXA/PDMAEMA mixed brushes under test conditions,regardless of whether PMOXA or PDMAEMA occupied the outermost layer.The antibacterial property of the mixed brushes against Escherichia coli was investigated.PMOXA/PDMAEMA mixed brushes showed significant bactericidal activity at pH 3,I=10^(-3)mol·L^(-1),while the rinse of pH 9,I=10^(-1)mol·L^(-1)solution could remove most of the residual bacteria.This work not only enables controlled adsorption of proteins with different isoelectric points but also ensures that the surface of the coating is minimized from bacterial contamination.展开更多
The health of your teeth and gums affects your whole body.You should brush your teeth in the morning and before bed.Brushing them after you eat is also good.Remember to floss your teeth,too.Then your mouth will be cle...The health of your teeth and gums affects your whole body.You should brush your teeth in the morning and before bed.Brushing them after you eat is also good.Remember to floss your teeth,too.Then your mouth will be clean,and your breath will be fresh!Since you use your toothbrush so often,be sure to get a new one every three months.展开更多
OBJECTIVE: To assess the diagnostic value of endoscopic pancreatic duct brushing in detecting mutation of the K-ras gene at codon 12 in cytologic specimens from patients with pancreatic cancer. METHODS: Thirty-five pa...OBJECTIVE: To assess the diagnostic value of endoscopic pancreatic duct brushing in detecting mutation of the K-ras gene at codon 12 in cytologic specimens from patients with pancreatic cancer. METHODS: Thirty-five patients treated at Changhai Hospital, Shanghai between 1999 and 2001 were enrolled. Their cells obtained by pancreatic duct brushing during endoscopic retrograde tholangiopancreatography (ERCP) were suspended with phosphate buffer solution (PBS). DNA of the cells was extracted and mutation of the K-ras gene at codon 12 detected by means of PCR-SSCP. RESULTS: The K-ras gene mutation rate of pancreatic cancer was 70%, which was higher than that of chronic pancreatitis (14%, P<0.05). K-ras gene mutation was not found in patients with pancreatic cystorcarcinoma and duodenum carcinoma. As to the location of pancreatic cancer, no significant difference was observed between the head, the body and tail. The sensitivity, specificity, accuracy of pancreatic duct brushing in detecting pancreatic cancer was 70%, 94%, and 83%, respectively. CONCLUSION: K-ras analysis of pancreatic brushing samples is helpful in the diagnosis of patients with early pancreatic cancer.展开更多
Preoperative cytologic brushing and biopsy under direct Vision withfiberoptic colonoscopy(FC)and postoperative histopathologic examination wereperformed in 147 patients who were suspected of suffering from carcinoma o...Preoperative cytologic brushing and biopsy under direct Vision withfiberoptic colonoscopy(FC)and postoperative histopathologic examination wereperformed in 147 patients who were suspected of suffering from carcinoma of co-lon.In FC cytologic brushing,128 cases were positive for malignancy(87.1percent),18 false-negative(12.2 percent)and only one false-positive(0.7 percent).In the 146 FC biopsy specimens,124 were positive for malignancy(84 4 percent)and 22 false-negative and no false-positive.Combination of FC cytologic brushingwith FC biopsy could raise the diagnostic rate of colonic carcinoma to 95.2% anddecrease false-negative and false-positive because the two methods may replenisheach other in sampling and observation.Cytologic brushing is most valuable tothe early diagnosis of colonic carcinoma.When colonic stricture and obstructionprevent the colonoscope from reaching the lesion and FC biopsy cannot bedone,FC cytologic brushing is an effective method for diagnosis.The positiverate and false-negative rate of the cytologic brushing did not correlate to grosstyping,histopathologic typing and Dukes staging(P】0.05).The factorsinfluencing the correct diagnosis of colonic carcinoma by FC cytologic brushingare discussed in this paper.展开更多
The effects of 3 chairside polishing kits and mechanical brushing on the surface roughness of 3 different acrylic denture base resins were compared. Acrylic denture base resins (auto-polymerizing, heat-polymerizing, ...The effects of 3 chairside polishing kits and mechanical brushing on the surface roughness of 3 different acrylic denture base resins were compared. Acrylic denture base resins (auto-polymerizing, heat-polymerizing, injected heat-polymerizing resins) were examined after a tungsten carbide bur, and after chairside polishing using 3 polishing kits and pumice. The specimens were subjected to mechanical brushing using a wear tester to simulate 30 000 strokes of brushing. The surface roughness of the acrylic denture base resin specimens was measured using a contact pro-filometer. After the test, the random polished acrylic resins were evaluated by scanning electron mi-croscopy (SEM) and atomic force microscopy (AFM). Acrylic denture base resins polished using the 3 types of polishing kits had a smoother surface than those finished with the tungsten carbide bur (p〈0.05). The surface of the resin polished by a TC cutter exceeded the Ra of 0.2 μm (p〈0.05). The auto-polymerizing resin showed a significantly higher surface roughness than the heat-polymerizing resin and injected heat-polymerizing resin (p〉0.05). In the case of polishing step wise, there was almost no change in surface roughness after brushing (p〉0.05).展开更多
Introduction and Objective: The aim of this research was to find out the interaction of anthropometric measurements particularly body mass and oral health status of Turkish young adult nationals regionally, depending ...Introduction and Objective: The aim of this research was to find out the interaction of anthropometric measurements particularly body mass and oral health status of Turkish young adult nationals regionally, depending on the effects of diet (food and fluid consumption), smoking and tooth brushing habits, which were determined by using the body mass index (BMI) and dental health index (DMFT). Material and Methods: The BMI and DMFT of 202 cases, with an age average 22.5 years, were recorded through physical and clinical examinations. Statistical evaluation of the data was checked by Cronbach’s Alpha Reliability Scale and performed by analysis of variance, Somer’s d and Pearson Chi-Square statistics, Poisson Regression and Odds Ratio analysis. Results: The results showed that the mean of BMI was at the optimum level (21.52) for all cases. The DMFT was higher for underweight females and for overweight males. The mean of DMFT according to sexes seemingly had no significant difference;however, females had 8.6% more DMFT than males. When the risk factors of dental caries were evaluated, the DMFT was found as 19.3% more for cases consuming high carbohydrate foods, 4.5% more for high beverage consumption and 18% more for smokers. Conclusions: In conclusion, tooth brushing 3 or more times a day is necessary to decrease the DMFT and tooth brushing 3 times a day as opposed to 1 or 2 times shows significant difference regarding oral health.展开更多
In this article, researches on improvement of 1RX regenerator used in cleaning processes of cotton ginning enterprises were carried out. The effect of changing the parameters of the new working body—rubber-plate drum...In this article, researches on improvement of 1RX regenerator used in cleaning processes of cotton ginning enterprises were carried out. The effect of changing the parameters of the new working body—rubber-plate drum and machine inlet on the efficiency of cotton separation was studied in the research, and the maximum level of efficiency of separation was determined. In this paper work, the main factors affecting the efficient operation of the regenerator were identified, their value limits were determined, and research was conducted using the mathematical planning method. As a result, effective operation of the improved 1RX cotton regenerator was observed at the value of the given factors, that is, the separation efficiency was 99.5%, the cleaning efficiency was higher than 88.7%, and the amount of seed cotton in the waste was reduced lower than 2.5%.展开更多
BACKGROUND Diagnosis of coronavirus disease 2019(COVID-19)-related neurological events in the pediatric population is challenging.Overlapping clinical picture of children with altered neurological state and inborn err...BACKGROUND Diagnosis of coronavirus disease 2019(COVID-19)-related neurological events in the pediatric population is challenging.Overlapping clinical picture of children with altered neurological state and inborn errors of metabolism,in addition to the frequency of asymptomatic COVID-19 cases,pose the main challenges for diagnosis.Diagnostic approaches to the onset post-COVID 19 subacute encephalopathy are still troublesome as seronegative autoimmune encephalitis(AIE)is reported.CASE SUMMARY A 27-mo-old boy was admitted for stormy refractory seizure of polymorphic semiology and altered mental status followed by various neuropsychiatric features that were suggestive of AIE.Brain magnetic resonance imaging and cerebrospinal fluid analysis were normal.Neither the immunological assessment,including viral serologies,antinuclear antibodies,autoimmune antibodies(NMDA,AMPA,CASPR2,LG11,GABARB,Hu,Yo,Ri,CV2,PNMA2,SOX1,Titin,amphiphysin,Recoverin),nor the metabolic assessment for lactate and pyruvate showed significant anomaly.Both positive history of COVID-19 infection and the findings of characteristic repetitive extreme delta brush played a key role in the diagnosis of COVID-19-related AIE.A remarkable improvement in the state of the child was noted after two pulse doses of intravenous Veinoglobulin and high dose of intravenous Corticosteroid.CONCLUSION Diagnostic biomarkers for AIE might aid effective treatment.展开更多
In this article, research was conducted to improve Linter machines that remove short fibers remaining in ginned cotton seeds at cotton ginneries. The study examined the effect of changing the dimensions of the brush d...In this article, research was conducted to improve Linter machines that remove short fibers remaining in ginned cotton seeds at cotton ginneries. The study examined the effect of changing the dimensions of the brush drum, guide and mesh surface in the cleaning device proposed for the linting machine on the movement of the peg and the cleaning efficiency, and the highest level of efficiency in separating impurities from the peg was determined. During the study, the main factors influencing the effective operation of the improved linting machine were identified, the limits of their values were determined, and studies were carried out using the mathematical modeling method. As a result, at the values of the given coefficients, efficient operation of the improved linting machine was observed, that is, the lint cleaning efficiency reached 55.1%.展开更多
The sliding electrical contact behavior of AuAgCu brush on Au plating was investigated at various normal loads and sliding speeds.The contact voltage drop and electrical noise between the two brushes were measured and...The sliding electrical contact behavior of AuAgCu brush on Au plating was investigated at various normal loads and sliding speeds.The contact voltage drop and electrical noise between the two brushes were measured and the resistance waveforms were recorded.The morphologies of the worn surfaces and wear debris of the brush and plating were observed.The results show that the contact voltage drop and electrical noise decrease with the addition of load whereas increase drastically with increasing sliding speed.With the electrical current in vacuum,the wear process of AuAgCu brush on Au plating involves adhesion,transfer of gold from the plating to the brush,rolling of wear debris between contact surfaces and arc-induced melt at the contact edge,and this gold-on-gold sliding electrical contact system is reliable within experiment period.展开更多
Cholangiocarcinomas arise from the epithelial cells of the bile ducts and are associated with poor prognosis. Despite new diagnostic approaches, the definite diagnosis of this malignancy continues to be challenging. C...Cholangiocarcinomas arise from the epithelial cells of the bile ducts and are associated with poor prognosis. Despite new diagnostic approaches, the definite diagnosis of this malignancy continues to be challenging. Cholangiocarcinomas often grow longitudinally along the bile duct rather than in a radial direction. Thus, large tumor masses are frequently absent and imaging techniques, including ultrasound, CT, and MRI have only limited sensitivity. Tissue collection during endoscopic (ERCP) and/or percutaneous transhepatic (PTC) procedures are usually used to confirm a definitive diagnosis of cholangiocarcinoma. However, forceps biopsy and brush cytology provide positive results for malignancy in about only 50% of patients. Percutaneous and peroral cholangioscopy using fiber-optic techniques were therefore developed for direct visualization of the biliary tree, yielding additional information about endoscopic appearance and tumor extension, as well as a guided biopsy acquistion. Finally, endoscopic ultrasonography (EUS) complements endoscopic and percutaneous approaches and may provide a tissue diagnosis of tumors in the biliary region through fine-needle aspiration. In the future, new techniques allowing for early detection, including molecular markers, should be developed to improve the diagnostic sensitivity in this increasing tumor entity.展开更多
AIM: To evaluate the sensitivity of brush cytology and forceps biopsy in a homogeneous patient group with hilar cholangiocarcinoma.METHODS: Brush cytology and forceps biopsy were routinely performed in patients with s...AIM: To evaluate the sensitivity of brush cytology and forceps biopsy in a homogeneous patient group with hilar cholangiocarcinoma.METHODS: Brush cytology and forceps biopsy were routinely performed in patients with suspected malignant biliary strictures. Fifty-eight consecutive patients undergoing endoscopic retrograde cholangio-pancreatography (ERCP) including forceps biopsy and brush cytology in patients with hilar cholangiocarcinoma between 1995-2005.RESULTS: Positive results for malignancy were obtained in 24/58 patients (41.4%) by brush cytology and in 31/58 patients (53.4%) by forceps biopsy. The combination of both techniques brush cytology and forceps biopsy resulted only in a minor increase in diagnostic sensitivity to 60.3% (35/58 patients). In 20/58 patients (34.5%), diagnosis were obtained by both positive cytology and positive histology, in 11/58 (19%) by positive histology (negative cytology) and only 4/58 patients (6.9%) were confirmed by positive cytology (negative histology).CONCLUSION: Brush cytology and forceps biopsy have only limited sensitivity for the diagnosis of malignant hilar tumors. In our eyes, additional diagnostic techniques should be evaluated and should become routine in patients with negative cytological and histological findings.展开更多
Peroral cholangioscopy was first described in 1970s and has recently gained popularity.Peroral cholangioscopy is appealing to therapeutic endoscopists because a direct intraluminal view of the biliary duct system offe...Peroral cholangioscopy was first described in 1970s and has recently gained popularity.Peroral cholangioscopy is appealing to therapeutic endoscopists because a direct intraluminal view of the biliary duct system offers possibilities for diagnosis and interventions beyond that which other imaging or endoscopic modalities can provide.As the image quality of cholangioscopies improves,so too does their diagnostic capability,and as their durability and maneuverability increases,so too does their potential use for therapeutic applications.This editorial is intended to provide a brief review of recent developments in peroral cholangioscopy and current indications for its use.展开更多
基金the Qatar National Research Fund for funding this work through NPRP(10-0127-170270,acknowledged under the grant code KK-2018-008).
文摘Confronting the severe health threats and environmental impacts of Cr(Ⅵ) in aquatic environments demands innovative and effective remediation approaches. In this study, Graphene oxide(GO)-decorated poly(dimethyl amino ethyl methacrylate)(PDMAEMA) brush nanocomposites(GOP1, GOP2, GOP3, and GOP4) were fabricated using atom transfer radical polymerization(ATRP) by the “graft from” method.The resulting nanocomposites were utilized for removing Cr(Ⅵ) with good adsorption performance due to the electrostatic interaction of protonated nitrogen groups in the brush chains with negatively charged particles in the solution. The kinetic model of pseudo-second-order best represented the contaminants' adsorption characteristics. The Weber-Morris model further indicated that surface adsorption and intraparticle diffusion mechanisms primarily controlled the adsorption procedure. Additionally, the Langmuir and Temkin isotherm models were found to most accurately represent the adsorption characteristics of the pollutants on the nanocomposites, and GOP4 can achieve the maximum adsorption capacity of 164.4 mg·g^(-1). The adsorbents' capacity maintains above 85% after five cycles of adsorption-desorption. The nanocomposites in this study demonstrate promising potential for eliminating Cr(Ⅵ) from aqueous solutions.
基金the financial support of the National Natural Science Foundation of China(21674102)。
文摘Herein,binary mixed brushes consisting of poly(2-methyl-2-oxazoline)(PMOXA)and poly(2-(dimethylamine)ethyl methacrylate)(PDMAEMA)with different chain lengths were fabricated by successive grafting of NH_(2)-terminated PMOXA and SH-terminated PDMAEMA onto polydopamine-anchored substrates.The mixed-brush coating was characterized by variable-angle spectroscopic ellipsometry,X-ray photoelectron spectroscopy,Fourier transform infrared spectroscopy,zeta potential measurements,water contact angle,and atomic force microscopy.The mixed brushes showed tunable surface charge,wettability,and surface roughness,depending on the degree of PDMAEMA swelling under varying pH and ionic strength(Ⅰ).Then the adsorption behaviors of pepsin,bovine serum albumin(BSA),γ-globulin,and lysozyme,four very different proteins with regard to isoelectric point,on the mixed brushes coating were studied by using fluorescence microscopy and surface plasmon resonance.When the chain length of PDMAEMA was about twice as long as PMOXA,the mixed brushes not only had high adsorption capacity for pepsin,BSA,and y-globulin but also had a desorption efficiency of 86.9%,87.1%,and 93.5%,respectively.It is explained that electrostatic attraction between the protonated PDMAEMA and positively charged acidic proteins(pepsin and BSA,whose isoelectric points were below the pK_(a) of PDMAEMA)would drive the intensive adsorption(at pH 3,I=10^(-3)mol·L^(-1)for pepsin,and pH 5,I=10^(-5)mol·L^(-1)for BSA),while desorption was dominated by the hydrophilic PMOXA when PDMAEMA was shrinking(at pH 7,I=10^(-1)mol·L^(-1)for pepsin,and pH 9,I=10^(-1)mol·L^(-1)for BSA).Furthermore,the isoelectric precipitation led to the adsorption of neutral protein(γ-globulin,whose isoelectric point was near the pK_a of PDMAEMA)at pH 7,I=10^(-5)mol·L^(-1),while electrostatic repulsion and antifouling PMOXA triggered the desorption of y-globulin at pH 3,I-10^(-1)mol·L^(-1).However,alkaline protein(lysozyme,whose isoelectric point was higher than the pK_(a) of PDMAEMA)exhibited slight adsorption on PMOXA/PDMAEMA mixed brushes under test conditions,regardless of whether PMOXA or PDMAEMA occupied the outermost layer.The antibacterial property of the mixed brushes against Escherichia coli was investigated.PMOXA/PDMAEMA mixed brushes showed significant bactericidal activity at pH 3,I=10^(-3)mol·L^(-1),while the rinse of pH 9,I=10^(-1)mol·L^(-1)solution could remove most of the residual bacteria.This work not only enables controlled adsorption of proteins with different isoelectric points but also ensures that the surface of the coating is minimized from bacterial contamination.
文摘The health of your teeth and gums affects your whole body.You should brush your teeth in the morning and before bed.Brushing them after you eat is also good.Remember to floss your teeth,too.Then your mouth will be clean,and your breath will be fresh!Since you use your toothbrush so often,be sure to get a new one every three months.
文摘OBJECTIVE: To assess the diagnostic value of endoscopic pancreatic duct brushing in detecting mutation of the K-ras gene at codon 12 in cytologic specimens from patients with pancreatic cancer. METHODS: Thirty-five patients treated at Changhai Hospital, Shanghai between 1999 and 2001 were enrolled. Their cells obtained by pancreatic duct brushing during endoscopic retrograde tholangiopancreatography (ERCP) were suspended with phosphate buffer solution (PBS). DNA of the cells was extracted and mutation of the K-ras gene at codon 12 detected by means of PCR-SSCP. RESULTS: The K-ras gene mutation rate of pancreatic cancer was 70%, which was higher than that of chronic pancreatitis (14%, P<0.05). K-ras gene mutation was not found in patients with pancreatic cystorcarcinoma and duodenum carcinoma. As to the location of pancreatic cancer, no significant difference was observed between the head, the body and tail. The sensitivity, specificity, accuracy of pancreatic duct brushing in detecting pancreatic cancer was 70%, 94%, and 83%, respectively. CONCLUSION: K-ras analysis of pancreatic brushing samples is helpful in the diagnosis of patients with early pancreatic cancer.
文摘Preoperative cytologic brushing and biopsy under direct Vision withfiberoptic colonoscopy(FC)and postoperative histopathologic examination wereperformed in 147 patients who were suspected of suffering from carcinoma of co-lon.In FC cytologic brushing,128 cases were positive for malignancy(87.1percent),18 false-negative(12.2 percent)and only one false-positive(0.7 percent).In the 146 FC biopsy specimens,124 were positive for malignancy(84 4 percent)and 22 false-negative and no false-positive.Combination of FC cytologic brushingwith FC biopsy could raise the diagnostic rate of colonic carcinoma to 95.2% anddecrease false-negative and false-positive because the two methods may replenisheach other in sampling and observation.Cytologic brushing is most valuable tothe early diagnosis of colonic carcinoma.When colonic stricture and obstructionprevent the colonoscope from reaching the lesion and FC biopsy cannot bedone,FC cytologic brushing is an effective method for diagnosis.The positiverate and false-negative rate of the cytologic brushing did not correlate to grosstyping,histopathologic typing and Dukes staging(P】0.05).The factorsinfluencing the correct diagnosis of colonic carcinoma by FC cytologic brushingare discussed in this paper.
文摘The effects of 3 chairside polishing kits and mechanical brushing on the surface roughness of 3 different acrylic denture base resins were compared. Acrylic denture base resins (auto-polymerizing, heat-polymerizing, injected heat-polymerizing resins) were examined after a tungsten carbide bur, and after chairside polishing using 3 polishing kits and pumice. The specimens were subjected to mechanical brushing using a wear tester to simulate 30 000 strokes of brushing. The surface roughness of the acrylic denture base resin specimens was measured using a contact pro-filometer. After the test, the random polished acrylic resins were evaluated by scanning electron mi-croscopy (SEM) and atomic force microscopy (AFM). Acrylic denture base resins polished using the 3 types of polishing kits had a smoother surface than those finished with the tungsten carbide bur (p〈0.05). The surface of the resin polished by a TC cutter exceeded the Ra of 0.2 μm (p〈0.05). The auto-polymerizing resin showed a significantly higher surface roughness than the heat-polymerizing resin and injected heat-polymerizing resin (p〉0.05). In the case of polishing step wise, there was almost no change in surface roughness after brushing (p〉0.05).
文摘Introduction and Objective: The aim of this research was to find out the interaction of anthropometric measurements particularly body mass and oral health status of Turkish young adult nationals regionally, depending on the effects of diet (food and fluid consumption), smoking and tooth brushing habits, which were determined by using the body mass index (BMI) and dental health index (DMFT). Material and Methods: The BMI and DMFT of 202 cases, with an age average 22.5 years, were recorded through physical and clinical examinations. Statistical evaluation of the data was checked by Cronbach’s Alpha Reliability Scale and performed by analysis of variance, Somer’s d and Pearson Chi-Square statistics, Poisson Regression and Odds Ratio analysis. Results: The results showed that the mean of BMI was at the optimum level (21.52) for all cases. The DMFT was higher for underweight females and for overweight males. The mean of DMFT according to sexes seemingly had no significant difference;however, females had 8.6% more DMFT than males. When the risk factors of dental caries were evaluated, the DMFT was found as 19.3% more for cases consuming high carbohydrate foods, 4.5% more for high beverage consumption and 18% more for smokers. Conclusions: In conclusion, tooth brushing 3 or more times a day is necessary to decrease the DMFT and tooth brushing 3 times a day as opposed to 1 or 2 times shows significant difference regarding oral health.
文摘In this article, researches on improvement of 1RX regenerator used in cleaning processes of cotton ginning enterprises were carried out. The effect of changing the parameters of the new working body—rubber-plate drum and machine inlet on the efficiency of cotton separation was studied in the research, and the maximum level of efficiency of separation was determined. In this paper work, the main factors affecting the efficient operation of the regenerator were identified, their value limits were determined, and research was conducted using the mathematical planning method. As a result, effective operation of the improved 1RX cotton regenerator was observed at the value of the given factors, that is, the separation efficiency was 99.5%, the cleaning efficiency was higher than 88.7%, and the amount of seed cotton in the waste was reduced lower than 2.5%.
文摘BACKGROUND Diagnosis of coronavirus disease 2019(COVID-19)-related neurological events in the pediatric population is challenging.Overlapping clinical picture of children with altered neurological state and inborn errors of metabolism,in addition to the frequency of asymptomatic COVID-19 cases,pose the main challenges for diagnosis.Diagnostic approaches to the onset post-COVID 19 subacute encephalopathy are still troublesome as seronegative autoimmune encephalitis(AIE)is reported.CASE SUMMARY A 27-mo-old boy was admitted for stormy refractory seizure of polymorphic semiology and altered mental status followed by various neuropsychiatric features that were suggestive of AIE.Brain magnetic resonance imaging and cerebrospinal fluid analysis were normal.Neither the immunological assessment,including viral serologies,antinuclear antibodies,autoimmune antibodies(NMDA,AMPA,CASPR2,LG11,GABARB,Hu,Yo,Ri,CV2,PNMA2,SOX1,Titin,amphiphysin,Recoverin),nor the metabolic assessment for lactate and pyruvate showed significant anomaly.Both positive history of COVID-19 infection and the findings of characteristic repetitive extreme delta brush played a key role in the diagnosis of COVID-19-related AIE.A remarkable improvement in the state of the child was noted after two pulse doses of intravenous Veinoglobulin and high dose of intravenous Corticosteroid.CONCLUSION Diagnostic biomarkers for AIE might aid effective treatment.
文摘In this article, research was conducted to improve Linter machines that remove short fibers remaining in ginned cotton seeds at cotton ginneries. The study examined the effect of changing the dimensions of the brush drum, guide and mesh surface in the cleaning device proposed for the linting machine on the movement of the peg and the cleaning efficiency, and the highest level of efficiency in separating impurities from the peg was determined. During the study, the main factors influencing the effective operation of the improved linting machine were identified, the limits of their values were determined, and studies were carried out using the mathematical modeling method. As a result, at the values of the given coefficients, efficient operation of the improved linting machine was observed, that is, the lint cleaning efficiency reached 55.1%.
文摘The sliding electrical contact behavior of AuAgCu brush on Au plating was investigated at various normal loads and sliding speeds.The contact voltage drop and electrical noise between the two brushes were measured and the resistance waveforms were recorded.The morphologies of the worn surfaces and wear debris of the brush and plating were observed.The results show that the contact voltage drop and electrical noise decrease with the addition of load whereas increase drastically with increasing sliding speed.With the electrical current in vacuum,the wear process of AuAgCu brush on Au plating involves adhesion,transfer of gold from the plating to the brush,rolling of wear debris between contact surfaces and arc-induced melt at the contact edge,and this gold-on-gold sliding electrical contact system is reliable within experiment period.
文摘Cholangiocarcinomas arise from the epithelial cells of the bile ducts and are associated with poor prognosis. Despite new diagnostic approaches, the definite diagnosis of this malignancy continues to be challenging. Cholangiocarcinomas often grow longitudinally along the bile duct rather than in a radial direction. Thus, large tumor masses are frequently absent and imaging techniques, including ultrasound, CT, and MRI have only limited sensitivity. Tissue collection during endoscopic (ERCP) and/or percutaneous transhepatic (PTC) procedures are usually used to confirm a definitive diagnosis of cholangiocarcinoma. However, forceps biopsy and brush cytology provide positive results for malignancy in about only 50% of patients. Percutaneous and peroral cholangioscopy using fiber-optic techniques were therefore developed for direct visualization of the biliary tree, yielding additional information about endoscopic appearance and tumor extension, as well as a guided biopsy acquistion. Finally, endoscopic ultrasonography (EUS) complements endoscopic and percutaneous approaches and may provide a tissue diagnosis of tumors in the biliary region through fine-needle aspiration. In the future, new techniques allowing for early detection, including molecular markers, should be developed to improve the diagnostic sensitivity in this increasing tumor entity.
文摘AIM: To evaluate the sensitivity of brush cytology and forceps biopsy in a homogeneous patient group with hilar cholangiocarcinoma.METHODS: Brush cytology and forceps biopsy were routinely performed in patients with suspected malignant biliary strictures. Fifty-eight consecutive patients undergoing endoscopic retrograde cholangio-pancreatography (ERCP) including forceps biopsy and brush cytology in patients with hilar cholangiocarcinoma between 1995-2005.RESULTS: Positive results for malignancy were obtained in 24/58 patients (41.4%) by brush cytology and in 31/58 patients (53.4%) by forceps biopsy. The combination of both techniques brush cytology and forceps biopsy resulted only in a minor increase in diagnostic sensitivity to 60.3% (35/58 patients). In 20/58 patients (34.5%), diagnosis were obtained by both positive cytology and positive histology, in 11/58 (19%) by positive histology (negative cytology) and only 4/58 patients (6.9%) were confirmed by positive cytology (negative histology).CONCLUSION: Brush cytology and forceps biopsy have only limited sensitivity for the diagnosis of malignant hilar tumors. In our eyes, additional diagnostic techniques should be evaluated and should become routine in patients with negative cytological and histological findings.
文摘Peroral cholangioscopy was first described in 1970s and has recently gained popularity.Peroral cholangioscopy is appealing to therapeutic endoscopists because a direct intraluminal view of the biliary duct system offers possibilities for diagnosis and interventions beyond that which other imaging or endoscopic modalities can provide.As the image quality of cholangioscopies improves,so too does their diagnostic capability,and as their durability and maneuverability increases,so too does their potential use for therapeutic applications.This editorial is intended to provide a brief review of recent developments in peroral cholangioscopy and current indications for its use.