A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distr...A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry.展开更多
Elastic heat transfer tube bundles are widely used in the field of flow-induced vibration heat transfer enhancement. Two types of mainly used tube bundles, the planar elastic tube bundle and the conical spiral tube bu...Elastic heat transfer tube bundles are widely used in the field of flow-induced vibration heat transfer enhancement. Two types of mainly used tube bundles, the planar elastic tube bundle and the conical spiral tube bundle were comprehensively compared in the condition of the same shell side diameter. The natural mode characteristics, the effect of fluid-structure interaction, the stress distribution, the comprehensive heat transfer performance and the secondary fluid flow of the two elastic tube bundles were all concluded and compared. The results show that the natural frequency and the critical velocity of vibration buckling of the planar elastic tube bundle are larger than those of the conical spiral tube bundle, while the stress distribution and the comprehensive heat transfer performance of the conical spiral tube bundle are relatively better.展开更多
Conical spiral tube bundle are universally used in heat transfer enhancement in heat exchangers.The heat transfer and resistance of the tube bundle are affected greatly by the conical structure,so the analysis of it i...Conical spiral tube bundle are universally used in heat transfer enhancement in heat exchangers.The heat transfer and resistance of the tube bundle are affected greatly by the conical structure,so the analysis of it is necessary.In order to a further evaluation,the heat transfer and resistance characteristics of conical spiral tube bundle are investigated with regression analysis based on numerical simulation data.The correlations of heat transfer and pressure drop of conical spiral tube bundle are proposed both in laminar and turbulent fluid flow.On the based of the field synergy principle,the synergy of four vectors,the velocity,the velocity gradient,the temperature gradient and the pressure gradient,are calculated and discussed via the user defined function(UDF) program.The synergy angles β and θ,which respectively denote the performance of heat transfer enhancement and pressure drop of the conical spiral tube bundle,are analyzed.Finally,the comprehensive performance of the conical spiral tube is evaluated by the synergy angle γ and all of the three synergy angles of conical spiral tube bundle are compared to both bare tube and thin cylinder-interpolated tube.The analysis of the synergy angles shows that the heat transfer enhancement and pressure drop of conical spiral tube bundle are smaller than that of the thin cylinder-interpolated tube,while the comprehensive performance of conical spiral tube bundle is greater.The analysis of the heat transfer and pressure drop of conical spiral tube is valuable and instructional on the design and optimum of conical spiral tube bundle heat exchangers.展开更多
Corrosion leakage occurred in the 14th tube bundle in the first row of a residual oil hydrotreating air cooler after operating for two years.The failure location was 0.5 m from the outlet header box.In this paper,the ...Corrosion leakage occurred in the 14th tube bundle in the first row of a residual oil hydrotreating air cooler after operating for two years.The failure location was 0.5 m from the outlet header box.In this paper,the erosion corrosion of the air cooler tube bundle was investigated by experimental and numerical methods.Visual inspection,scanning electron microscopy(SEM),and X-ray diffraction(XRD)experiments were performed,and the failure morphology and material composition confirmed that the damage was caused by erosion corrosion.The shear stress transport k–ωturbulence model(SST-k–ω)was then used to investigate the flow and erosion corrosion characteristics,combined with mass transfer,corrosion rate,and ionization equilibrium models.The numerical simulation results revealed that the water phase volume fraction increased with flow and heat transfer in the fluid,which increased the mass flow rate and concentration of hydrogen sulfide.The mass transfer coefficient and corrosion rate were proposed as important parameters to characterize erosion corrosion.Moreover,the local concentration of wall shear stress was found to increase the risk of erosion corrosion.The predicted high-risk area was consistent with the actual failure area,which verified that this failure incident was attributable to erosion corrosion by the water phase.展开更多
Vibration in heat exchangers is one of the main problems that the industry has faced over last few decades. Vibration phenomenon in heat exchangers is of major concern for designers and process engineers since it can ...Vibration in heat exchangers is one of the main problems that the industry has faced over last few decades. Vibration phenomenon in heat exchangers is of major concern for designers and process engineers since it can lead to the tube damage, tube leakage, baffle damage, tube collision damage, fatigue, creep etc. In the present study, vibration response is analyzed on single tube located in the centre of the tube bundle having parallel triangular arrangement(60°) with P/D ratio of 1.44. The experiment is performed for two different flow conditions. This kind of experiment has not been reported in the literature. Under the first condition, the tube vibration response is analyzed when there is no internal flow in the tube and under the second condition, the response is analyzed when the internal tube flow is maintained at a constant value of 0.1 m/s. The free stream shell side velocity ranges from 0.8 m/s to 1.3 m/s, the reduced gap velocity varies from 1.80 to 2.66 and the Reynolds number varies from 44500 to 66000. It is observed that the internal tube flow results in larger vibration amplitudes for the tube than that without internal tube flow. It is also established that over the current range of shell side flow velocity, the turbulence is the dominant excitation mechanism for producing vibration in the tube since the amplitude varies directly with the increase in the shell side velocity. Damping has no significant effect on the vibration behavior of the tube for the current velocity range.展开更多
An experimental study on heat transfer and resistance coefficients of linearly arranged smooth and spirally corrugated tube bundles in cross-flow was performed. The heat transfer and resistance coefficients are presen...An experimental study on heat transfer and resistance coefficients of linearly arranged smooth and spirally corrugated tube bundles in cross-flow was performed. The heat transfer and resistance coefficients are presented in this paper with transverse and longitudinal tube-pitch and tube geometries taken into account. The experiment's results can provide technical guidelines for application to horizontal air preheater with arranged in-line spirally corrugated tube bundles, especially to the air preheater for CFBCBs (Circulating Fluidized Bed Combustion Boilers).展开更多
Flow?induced vibration plays a positive role on heat transfer enhancement. Meanwhile, it is also a negative factor for fatigue strength. Satisfying the fatigue strength is the primary prerequisite for heat transfer en...Flow?induced vibration plays a positive role on heat transfer enhancement. Meanwhile, it is also a negative factor for fatigue strength. Satisfying the fatigue strength is the primary prerequisite for heat transfer enhancement. This paper numerically studied the flow?induced vibration of planar elastic tube bundle based on a two?way fluid–structure interaction(FSI) calculation. The numerical calculation involved the unsteady, three?dimensional incompressible governing equations solved with finite volume approach and the dynamic balance equation of planar elastic tube bundle solved with finite element method combined with dynamic mesh scheme. The numerical approach was verified by comparing with the published experimental results. Then the vibration trajectory, deformation and stress contour of planar elastic tube bundle were all studied. Results show that the combined movement of planar elastic tube bundle represents the agitation from inside to outside. The vibration of out?of?plane is the main vibration form with the typically sinusoidal behavior because the magnitude of displacement along the out?of?plane direction is the 100 times than the value of in?plane direction. The dangerous point locates in the innermost tube where the equivalent stress can be utilized to study the multiaxial fatigue of planar elastic tube bundle due to the alternating stress concentration. In the velocity range of 0.2-3 m/s, it is inferred that the vibration amplitude plays a role on the stress response and the stress amplitude is susceptible to the fluid velocity. This research paves a way for studying the fatigue strength of planar elastic tube bundle by flow?induced vibration.展开更多
In order to optimize the design of the submerged combustion vaporizer(SCV), an experimental apparatus was set up to investigate the heat transfer character outside the tube bundle in SCV. Several experiments were cond...In order to optimize the design of the submerged combustion vaporizer(SCV), an experimental apparatus was set up to investigate the heat transfer character outside the tube bundle in SCV. Several experiments were conducted using water and CO_2 as the heat transfer media in the tubes, respectively. The results indicated that hot air flux, the initial liquid level height and the tube pitch ratio had great influence on the heat transfer coefficient outside the tube bundle(ho). Finally, the air flux associated factor β and height associated factor γ were introduced to propose a new hocorrelation. After verified by experiments using cold water, high pressure CO_2 and liquid N_2 as heat transfer media, respectively, it was found that the biggest deviation between the predicted and the experimental values was less than 25%.展开更多
The present work considered the capillary micro-flow through a fiber bundle.The resin heights in the fiber bundle as a function of time were used to determine the experimental values of capillary pressure and the perm...The present work considered the capillary micro-flow through a fiber bundle.The resin heights in the fiber bundle as a function of time were used to determine the experimental values of capillary pressure and the permeability by the nonlinear regression fitting method.The fitting curves showed a good agreement with experiments.However,these values of capillary pressure from short-time experiments were much lower than the theoretical results from the Yang-Laplace Equation.More accurate capillary pressure was predicted from the presented long-run experiment.展开更多
A numerical model was proposed to simulate the capillary micro-flow through a fiber bundle. The capillary pressure was predicted by the Young-Laplace equation and the corresponding optimal values of permeability were ...A numerical model was proposed to simulate the capillary micro-flow through a fiber bundle. The capillary pressure was predicted by the Young-Laplace equation and the corresponding optimal values of permeability were found by a trial-and-error method. The empirical Kozeny constants which are dependent on fiber volume fraction were recommended for the prediction of permeability.展开更多
In this paper, a bank of tubes containing a flowing fluid which is immersed in a cross flow second medium of fluid with different temperature has been studied numerically using computational fluid dynamics. Laminar st...In this paper, a bank of tubes containing a flowing fluid which is immersed in a cross flow second medium of fluid with different temperature has been studied numerically using computational fluid dynamics. Laminar steady flow with a low Reynolds number has been studied in this work. Inlet mass flow rate and the bulk temperature are known and numerical method has been implemented to study the convective heat transfer to investigate the temperature and flow fields. Effects of different inlet bulk temperatures and mass flow rates have been investigated on temperature and pressure variations.展开更多
Characteristics of R22 and its new alternative refrigerant R290 flowing through adiabatic capillary tubes are investigated based on the homogeneous model.Extensive flow variables along tube length such as pressure, te...Characteristics of R22 and its new alternative refrigerant R290 flowing through adiabatic capillary tubes are investigated based on the homogeneous model.Extensive flow variables along tube length such as pressure, temperature, viscosity, velocity, Reynolds number, friction factor and vapor quality etc are compared between the two fluids under the same operating condition. Two cases are considered, namely, either the same tube length or the same mass flow rate as inlet condition. The results show that the mass flow rate in the capillary tube of R290 is 4000 lower than that of R22 due to the differences of physical properties between the two fluids. Further, a parametric analysis is performed and it appears that effects of geometric and thermodynamic parameters on mass flow rate of R290 are weaker than that of R22. When the condensing temperature is increased from 40 ℃ to 50 ℃, the mass flow rate for R22 is increased by 1600, while the increasing rate for R290 is 1300.展开更多
Capillary chromatography using an untreated open tubular capillary tube and a ternary solvent mixture consisting of water-hydrophilic/hydrophobic organic solvent as a carrier solution has been developed. The system is...Capillary chromatography using an untreated open tubular capillary tube and a ternary solvent mixture consisting of water-hydrophilic/hydrophobic organic solvent as a carrier solution has been developed. The system is called tube radical distribution chromatography (TRDC). Separation performance of the TRDC system using a fused-silica capillary tube was examined through the phase diagram for the ternary water-acetonitrile-ethyl acetate solvent mixture. The TRDC system required homogeneous carrier solutions with solvent component ratios around the boundary curve between homogeneous and heterogeneous solution in the phase diagram. The data obtained using the fused-silica capillary tube were compared with those obtained using a polytetrafluoroethylene capillary tube in our previous study.展开更多
The machine tool coolers are the best managers of coolant temperature in avoiding the deviation of spindle centerline for machine tools. However, the machine coolers are facing the compressed schedule to phase out the...The machine tool coolers are the best managers of coolant temperature in avoiding the deviation of spindle centerline for machine tools. However, the machine coolers are facing the compressed schedule to phase out the HCFC (hydro-chloro-floro-carbon) refrigerant and little attention has been paid to comparative study on sizing capillary tube for retrofitted HFC (hydro-floro-carbon) refrigerant. In this paper, the adiabatic flow in capillary tube is analyzed and modeled for retrofitting of HFC-407C refrigerant in a machine tool cooler system. A computer code including determining the length of sub-cooled flow region and the two phase region of capillary tube is developed. Comparative study of HCFC-22 and HFC-407C in a capillary tube is derived and conducted to simplify the traditional trial-and-error method of predicting the length of capillary tubes. Besides, experimental investigation is carried out by field tests to verify the simulation model and cooling performance of the machine tool cooler system. The results from the experiments reveal that the numerical model provides an effective approach to determine the performance data of capillary tube specific for retrofitting a HFC-407C machine tool cooler. The developed machine tool cooler system is not only directly compatible with new HFC-407C refrigerant, but can also perform a cost-effective temperature control specific for industrial machines.展开更多
A homogeneous theoretical model is developed to predict the performance of R22 and R290 in adiabatic capillary tubes. The model is based on conservation equations of mass, momentum and energy. Metastable both liquid a...A homogeneous theoretical model is developed to predict the performance of R22 and R290 in adiabatic capillary tubes. The model is based on conservation equations of mass, momentum and energy. Metastable both liquid and two-phase flow regions are considered in the model. In metastable two-phase region, superheated liquid is introduced into the metastable mixture viscosity and two methods are presented to evaluate it. The model is validated by comparing the predicted pressure and temperature profile and mass flow rate with several investigators′ experimental data of R22 and one of its alternatives R290 reported in literature. All of the predicted mass flow rates are within ±800 of measured values. Comparisons are also made between the present model and other investigators′ models or sizing correlation. The model can be used for design or simulation calculation of adiabatic capillary tubes.展开更多
基金supported by the open foundation of State Key Laboratory of Chemical Engineering (SKL-ChE-18B03)the Municipal Science and Technology Commission of Tianjin (No. 2009ZCKFGX01900)
文摘A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry.
基金Projects(xjj2013104,08143063)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(2011CB706606)supported by the National Basic Research Program of China
文摘Elastic heat transfer tube bundles are widely used in the field of flow-induced vibration heat transfer enhancement. Two types of mainly used tube bundles, the planar elastic tube bundle and the conical spiral tube bundle were comprehensively compared in the condition of the same shell side diameter. The natural mode characteristics, the effect of fluid-structure interaction, the stress distribution, the comprehensive heat transfer performance and the secondary fluid flow of the two elastic tube bundles were all concluded and compared. The results show that the natural frequency and the critical velocity of vibration buckling of the planar elastic tube bundle are larger than those of the conical spiral tube bundle, while the stress distribution and the comprehensive heat transfer performance of the conical spiral tube bundle are relatively better.
基金supported by National Basic Research Program of China(973 Program,Grant No. 2007CB206900)Scholarship Award for Doctoral by Ministry of Education of China(Grant No. 10000071183646)
文摘Conical spiral tube bundle are universally used in heat transfer enhancement in heat exchangers.The heat transfer and resistance of the tube bundle are affected greatly by the conical structure,so the analysis of it is necessary.In order to a further evaluation,the heat transfer and resistance characteristics of conical spiral tube bundle are investigated with regression analysis based on numerical simulation data.The correlations of heat transfer and pressure drop of conical spiral tube bundle are proposed both in laminar and turbulent fluid flow.On the based of the field synergy principle,the synergy of four vectors,the velocity,the velocity gradient,the temperature gradient and the pressure gradient,are calculated and discussed via the user defined function(UDF) program.The synergy angles β and θ,which respectively denote the performance of heat transfer enhancement and pressure drop of the conical spiral tube bundle,are analyzed.Finally,the comprehensive performance of the conical spiral tube is evaluated by the synergy angle γ and all of the three synergy angles of conical spiral tube bundle are compared to both bare tube and thin cylinder-interpolated tube.The analysis of the synergy angles shows that the heat transfer enhancement and pressure drop of conical spiral tube bundle are smaller than that of the thin cylinder-interpolated tube,while the comprehensive performance of conical spiral tube bundle is greater.The analysis of the heat transfer and pressure drop of conical spiral tube is valuable and instructional on the design and optimum of conical spiral tube bundle heat exchangers.
基金supported by the National Natural Science Foundation of China(Grant Nos.51876194,U1909216,and 52176048)the Fundamental Research Funds of Zhejiang Sci-Tech University(Grant No.2021Q020).
文摘Corrosion leakage occurred in the 14th tube bundle in the first row of a residual oil hydrotreating air cooler after operating for two years.The failure location was 0.5 m from the outlet header box.In this paper,the erosion corrosion of the air cooler tube bundle was investigated by experimental and numerical methods.Visual inspection,scanning electron microscopy(SEM),and X-ray diffraction(XRD)experiments were performed,and the failure morphology and material composition confirmed that the damage was caused by erosion corrosion.The shear stress transport k–ωturbulence model(SST-k–ω)was then used to investigate the flow and erosion corrosion characteristics,combined with mass transfer,corrosion rate,and ionization equilibrium models.The numerical simulation results revealed that the water phase volume fraction increased with flow and heat transfer in the fluid,which increased the mass flow rate and concentration of hydrogen sulfide.The mass transfer coefficient and corrosion rate were proposed as important parameters to characterize erosion corrosion.Moreover,the local concentration of wall shear stress was found to increase the risk of erosion corrosion.The predicted high-risk area was consistent with the actual failure area,which verified that this failure incident was attributable to erosion corrosion by the water phase.
基金the financial and technical support of University of Engineering and Technology, Taxila for carrying out the research
文摘Vibration in heat exchangers is one of the main problems that the industry has faced over last few decades. Vibration phenomenon in heat exchangers is of major concern for designers and process engineers since it can lead to the tube damage, tube leakage, baffle damage, tube collision damage, fatigue, creep etc. In the present study, vibration response is analyzed on single tube located in the centre of the tube bundle having parallel triangular arrangement(60°) with P/D ratio of 1.44. The experiment is performed for two different flow conditions. This kind of experiment has not been reported in the literature. Under the first condition, the tube vibration response is analyzed when there is no internal flow in the tube and under the second condition, the response is analyzed when the internal tube flow is maintained at a constant value of 0.1 m/s. The free stream shell side velocity ranges from 0.8 m/s to 1.3 m/s, the reduced gap velocity varies from 1.80 to 2.66 and the Reynolds number varies from 44500 to 66000. It is observed that the internal tube flow results in larger vibration amplitudes for the tube than that without internal tube flow. It is also established that over the current range of shell side flow velocity, the turbulence is the dominant excitation mechanism for producing vibration in the tube since the amplitude varies directly with the increase in the shell side velocity. Damping has no significant effect on the vibration behavior of the tube for the current velocity range.
文摘An experimental study on heat transfer and resistance coefficients of linearly arranged smooth and spirally corrugated tube bundles in cross-flow was performed. The heat transfer and resistance coefficients are presented in this paper with transverse and longitudinal tube-pitch and tube geometries taken into account. The experiment's results can provide technical guidelines for application to horizontal air preheater with arranged in-line spirally corrugated tube bundles, especially to the air preheater for CFBCBs (Circulating Fluidized Bed Combustion Boilers).
基金Supported by National Natural Science Foundation of China(Grant No.51475268)National Basic Research Program of China(973 Program,Grant No.2007CB206903)
文摘Flow?induced vibration plays a positive role on heat transfer enhancement. Meanwhile, it is also a negative factor for fatigue strength. Satisfying the fatigue strength is the primary prerequisite for heat transfer enhancement. This paper numerically studied the flow?induced vibration of planar elastic tube bundle based on a two?way fluid–structure interaction(FSI) calculation. The numerical calculation involved the unsteady, three?dimensional incompressible governing equations solved with finite volume approach and the dynamic balance equation of planar elastic tube bundle solved with finite element method combined with dynamic mesh scheme. The numerical approach was verified by comparing with the published experimental results. Then the vibration trajectory, deformation and stress contour of planar elastic tube bundle were all studied. Results show that the combined movement of planar elastic tube bundle represents the agitation from inside to outside. The vibration of out?of?plane is the main vibration form with the typically sinusoidal behavior because the magnitude of displacement along the out?of?plane direction is the 100 times than the value of in?plane direction. The dangerous point locates in the innermost tube where the equivalent stress can be utilized to study the multiaxial fatigue of planar elastic tube bundle due to the alternating stress concentration. In the velocity range of 0.2-3 m/s, it is inferred that the vibration amplitude plays a role on the stress response and the stress amplitude is susceptible to the fluid velocity. This research paves a way for studying the fatigue strength of planar elastic tube bundle by flow?induced vibration.
文摘In order to optimize the design of the submerged combustion vaporizer(SCV), an experimental apparatus was set up to investigate the heat transfer character outside the tube bundle in SCV. Several experiments were conducted using water and CO_2 as the heat transfer media in the tubes, respectively. The results indicated that hot air flux, the initial liquid level height and the tube pitch ratio had great influence on the heat transfer coefficient outside the tube bundle(ho). Finally, the air flux associated factor β and height associated factor γ were introduced to propose a new hocorrelation. After verified by experiments using cold water, high pressure CO_2 and liquid N_2 as heat transfer media, respectively, it was found that the biggest deviation between the predicted and the experimental values was less than 25%.
文摘The present work considered the capillary micro-flow through a fiber bundle.The resin heights in the fiber bundle as a function of time were used to determine the experimental values of capillary pressure and the permeability by the nonlinear regression fitting method.The fitting curves showed a good agreement with experiments.However,these values of capillary pressure from short-time experiments were much lower than the theoretical results from the Yang-Laplace Equation.More accurate capillary pressure was predicted from the presented long-run experiment.
文摘A numerical model was proposed to simulate the capillary micro-flow through a fiber bundle. The capillary pressure was predicted by the Young-Laplace equation and the corresponding optimal values of permeability were found by a trial-and-error method. The empirical Kozeny constants which are dependent on fiber volume fraction were recommended for the prediction of permeability.
文摘In this paper, a bank of tubes containing a flowing fluid which is immersed in a cross flow second medium of fluid with different temperature has been studied numerically using computational fluid dynamics. Laminar steady flow with a low Reynolds number has been studied in this work. Inlet mass flow rate and the bulk temperature are known and numerical method has been implemented to study the convective heat transfer to investigate the temperature and flow fields. Effects of different inlet bulk temperatures and mass flow rates have been investigated on temperature and pressure variations.
基金Supported by the Fund of"985 Project"of Tianjin University (TD2001011).
文摘Characteristics of R22 and its new alternative refrigerant R290 flowing through adiabatic capillary tubes are investigated based on the homogeneous model.Extensive flow variables along tube length such as pressure, temperature, viscosity, velocity, Reynolds number, friction factor and vapor quality etc are compared between the two fluids under the same operating condition. Two cases are considered, namely, either the same tube length or the same mass flow rate as inlet condition. The results show that the mass flow rate in the capillary tube of R290 is 4000 lower than that of R22 due to the differences of physical properties between the two fluids. Further, a parametric analysis is performed and it appears that effects of geometric and thermodynamic parameters on mass flow rate of R290 are weaker than that of R22. When the condensing temperature is increased from 40 ℃ to 50 ℃, the mass flow rate for R22 is increased by 1600, while the increasing rate for R290 is 1300.
文摘Capillary chromatography using an untreated open tubular capillary tube and a ternary solvent mixture consisting of water-hydrophilic/hydrophobic organic solvent as a carrier solution has been developed. The system is called tube radical distribution chromatography (TRDC). Separation performance of the TRDC system using a fused-silica capillary tube was examined through the phase diagram for the ternary water-acetonitrile-ethyl acetate solvent mixture. The TRDC system required homogeneous carrier solutions with solvent component ratios around the boundary curve between homogeneous and heterogeneous solution in the phase diagram. The data obtained using the fused-silica capillary tube were compared with those obtained using a polytetrafluoroethylene capillary tube in our previous study.
基金supported by Science Council of Taiwan, China (Grant No. NSC 98-2622-E-167-029-CC3)Industrial Technology Research Institute of Taiwan, China
文摘The machine tool coolers are the best managers of coolant temperature in avoiding the deviation of spindle centerline for machine tools. However, the machine coolers are facing the compressed schedule to phase out the HCFC (hydro-chloro-floro-carbon) refrigerant and little attention has been paid to comparative study on sizing capillary tube for retrofitted HFC (hydro-floro-carbon) refrigerant. In this paper, the adiabatic flow in capillary tube is analyzed and modeled for retrofitting of HFC-407C refrigerant in a machine tool cooler system. A computer code including determining the length of sub-cooled flow region and the two phase region of capillary tube is developed. Comparative study of HCFC-22 and HFC-407C in a capillary tube is derived and conducted to simplify the traditional trial-and-error method of predicting the length of capillary tubes. Besides, experimental investigation is carried out by field tests to verify the simulation model and cooling performance of the machine tool cooler system. The results from the experiments reveal that the numerical model provides an effective approach to determine the performance data of capillary tube specific for retrofitting a HFC-407C machine tool cooler. The developed machine tool cooler system is not only directly compatible with new HFC-407C refrigerant, but can also perform a cost-effective temperature control specific for industrial machines.
文摘A homogeneous theoretical model is developed to predict the performance of R22 and R290 in adiabatic capillary tubes. The model is based on conservation equations of mass, momentum and energy. Metastable both liquid and two-phase flow regions are considered in the model. In metastable two-phase region, superheated liquid is introduced into the metastable mixture viscosity and two methods are presented to evaluate it. The model is validated by comparing the predicted pressure and temperature profile and mass flow rate with several investigators′ experimental data of R22 and one of its alternatives R290 reported in literature. All of the predicted mass flow rates are within ±800 of measured values. Comparisons are also made between the present model and other investigators′ models or sizing correlation. The model can be used for design or simulation calculation of adiabatic capillary tubes.