Continuous determination of bath carbon content on 150tBOF by off-gas analyzer 被引量:1
1
作者 ZhigangHu PingHe +1 位作者 MingxiangTan LiuLiu 《Journal of University of Science and Technology Beijing》 CSCD 2003年第6期22-25,共4页
The first imported off-gas analysis system on 150 t BOF at Benxi Plates Co.Ltd. is presented and the continuous determination of bath carbon content has been studied. Thecomparison between the whole-course carbon inte... The first imported off-gas analysis system on 150 t BOF at Benxi Plates Co.Ltd. is presented and the continuous determination of bath carbon content has been studied. Thecomparison between the whole-course carbon integral model and the end-point carbon prediction modelhas been made. The results show that the regular change of CO, CO_2 and N_2 content in the off-gasduring blowing plays an important role in judging the smelting end-point of converter; the cubiccurve fitting model has a higher hit rate over 95 percent for the heats whose end-point carboncontent is lower than 0.10 percent with a precision of +-0.02 percent and has a large error for theheats whose end-point carbon content is more than 0.15 percent. 展开更多
关键词 off-gas analysis continuous determination of bath carbon dynamic control BOF
下载PDF
Chemical Analysis Method for Carbon Bearing Refractory Products——Determination of the Total Carbon by Combustion Gravimetric Method 被引量:1
2
作者 Shen Keyin 《China's Refractories》 CAS 2007年第1期34-36,共3页
GB/T 13245-91 1 Theme and Scope This standard specifies the method abstract, reagents, apparatus, specimen, analyzing procedure, result calculation and permissible tolerance used for determination of the total carbon ... GB/T 13245-91 1 Theme and Scope This standard specifies the method abstract, reagents, apparatus, specimen, analyzing procedure, result calculation and permissible tolerance used for determination of the total carbon with combustion gravimetric method. 展开更多
关键词 determination of the Total carbon by Combustion Gravimetric Method Chemical Analysis Method for carbon Bearing Refractory Products
下载PDF
Square wave voltammetric quantification of folic acid,uric acid and ascorbic acid in biological matrix 被引量:1
3
作者 Majid Arvand Akram Pourhabib Masoud Giahi 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2017年第2期110-117,共8页
Nowadays, modified electrodes with metal nanoparticles have appeared as an alternative for the electroanalysis of various compounds. In this study, gold nanoparticles(GNPs) were chosen as interesting metal nanoparti... Nowadays, modified electrodes with metal nanoparticles have appeared as an alternative for the electroanalysis of various compounds. In this study, gold nanoparticles(GNPs) were chosen as interesting metal nanoparticles for modifying carbon paste electrode(CPE). GNPs and the gold nanoparticles-modified carbon paste electrode(GNPs/CPE) were characterized by UV–Vis spectroscopy, transmission electron microscopy(TEM) and scanning electron microscopy(SEM). GNPs/CPE as a simple and sensitive electrode was used to study three important biological molecules: folic acid(FA), uric acid(UA) and ascorbic acid(AA). Square wave voltammetry(SWV) was used as an accurate technique for quantitative measurements. A good linear relation was observed between anodic peak current(ipa) and FA(5.2 × 10(-6)– 2.5 × 10(-5)M), UA(1.2 × 10(-6)– 2.1 × 10(-5)M) and AA(1.2 × 10(-6)– 2.5 × 10(-5)M) concentrations in simultaneous determination of these molecules. 展开更多
关键词 Ascorbic acid Folic acid gold nanoparticles-modified carbon paste electrode Simultaneous determination Uric acid
下载PDF
New All-solid-state Carbonate Ion-selective Electrode with Ag2CO3-BaCO3 as Sensitive Films
4
作者 ZHAO Yue HAN Chenhua +4 位作者 HUANG Yuanfeng QIN Wenli ZHANG Xiao KAN Yating YE Ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2016年第4期655-660,共6页
A new all-solid-state carbonate ion-selective electrode was fabricated via electrochemical and ion-exchange reactions with Ag nanoparticles and Ag2CO3-BaCO3 as ion-to-electron transducer and ion-selective layer, respe... A new all-solid-state carbonate ion-selective electrode was fabricated via electrochemical and ion-exchange reactions with Ag nanoparticles and Ag2CO3-BaCO3 as ion-to-electron transducer and ion-selective layer, respectively. This paper presented the detailed procedures of the construction of the electrode, the applications of the electrode in various experiments, and the corresponding chemical reaction principles involved. The fabricated electrode was characterized by means of scanning electron microscopy(SEM), energy dispersive spectrometer(EDS), and electrochemical analyses. The electrode exhibited stable linear responses to carbonate anions(10-5--10-1 mol/L) with average Slope of the curve being -26.56 mV per decade, and showed negligible responses to NO3, SO2-, and Sal- anions. The electrode was further used to measure the concentration of carbonate anions in boiler water. The measured concentration was lower than that determined via titration. Overall, the electrode exhibited the advantages of miniaturized size, robust construction, and compatibility with other equipment and thus could be ideally integrated into various sensor platforms to collect chemical data from industrial heat exchangers. 展开更多
关键词 Ag2CO3-BaCO3 Ion-selective electrode carbonate determination Heat exchange water