BACKGROUND Antinuclear antibodies(ANAs)are crucial in diagnosing autoimmune diseases,mainly systemic lupus erythematosus(SLE).This study aimed to compare the performance of chemiluminescence assay(CLIA)and line immuno...BACKGROUND Antinuclear antibodies(ANAs)are crucial in diagnosing autoimmune diseases,mainly systemic lupus erythematosus(SLE).This study aimed to compare the performance of chemiluminescence assay(CLIA)and line immunoassay(LIA)in detecting ANAs in patients with autoimmune diseases,evaluate their diagnostic accuracy for SLE,and develop a novel diagnostic model using CLIA-detected antibodies for SLE.Specimens from patients with autoimmune diseases and physical examination specimens were collected to parallel detect specific antibodies.Individual antibodies'diagnostic performance and a model combining multiple antibodies were assessed.The findings provide valuable insights into improving the diagnosis of SLE through innovative approaches.AIM To compare the performance of CLIA and LIA in detecting ANAs in patients with autoimmune diseases,assess their accuracy for SLE,and develop a novel diagnostic model using CLIA-detected antibodies for SLE.METHODS Specimens have been obtained from 270 patients with clinically diagnosed autoimmune disorders,as well as 130 physical examination specimens.After that,parallel detection of anti-double-stranded DNA(dsDNA)antibody,anti-histone(Histone)antibody,anti-nucleosome(Nuc)antibody,anti-Smith(Sm)antibody,anti-ribosomal P protein(Rib-P)antibody,anti-sicca syndrome A(Ro60)antibody,anti-sicca syndrome A(Ro52)antibody,anti-sicca syndrome(SSB)antibody,anticentromere protein B(Cenp-B)antibody,anti-DNA topoisomerase 1(Scl-70)antibody,anti-histidyl tRNA synthetase(Jo-1)antibody,and anti-mitochondrial M2(AMA-M2)antibody was performed using CLIA and LIA.The detection rates,compliance rates,and diagnostic performance for SLE were compared between the two methodologies,followed by developing a novel diagnostic model for SLE.RESULTS CLIA and LIA exhibited essentially comparable detection rates for anti-dsDNA antibody,anti-Histone antibody,anti-Nuc antibody,anti-Sm antibody,anti-Rib-P antibody,anti-Ro60 antibody,anti-Ro52 antibody,anti-SSB antibody,anti-Cenp-B antibody,anti-DNAScl-70 antibody,anti-Jo-1 antibody and anti-AMA-M2 antibody(P>0.05).The two methods displayed identical results for the detection of anti-dsDNA antibody,anti-Histone antibody,anti-Nuc antibody,anti-Sm antibody,anti-Ro60 antibody,anti-Ro52 antibody,anti-SSB antibody,anti-Cenp-B antibody,anti-Scl-70 antibody,and anti-AMA-M2 antibody(Kappa>0.7,P<0.05),but showed a moderate agreement for the detection of anti-Rib-P antibody and anti-Jo-1 antibody(Kappa=0.671 and 0.665;P<0.05).In addition,the diagnostic performance of these antibodies detected by both methods was similar for SLE.The diagnostic model's area under the curve values,sensitivity,and specificity,including an anti-dsDNA antibody and an anti-Ro60 antibody detected by CLIA,were 0.997,0.962,and 0.978,respectively.These values were higher than the diagnostic performance of individual antibodies.CONCLUSION CLIA and LIA demonstrated excellent overall consistency in detecting ANA profiles.A diagnostic model based on CLIA-detected antibodies can successfully contribute to developing a novel technique for detecting SLE.展开更多
A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium pe...A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium permanganate in a hydrochloric acid medium, enhanced by formaldehyde (HCHO). Under optimum conditions, calibration curve over the range of 1.0-20.0μg/mL was obtained. The proposed method was successfully applied to the determination of meloxicam in capsules with no evi- dence of interference from common excipients. The detection limit of this method was 25.6 ng/mL. The relative standard deviation was 2.1% for 10.0 μg/mL meloxicam. The sample throughput was found to be 120 samples/h.展开更多
A new chemiluminescence flow system has been developed for sequential determina-tion of benzoic acid based on the reaction of the compound with copper carbonate entrapped in a solid-phase reactor. It was found that t...A new chemiluminescence flow system has been developed for sequential determina-tion of benzoic acid based on the reaction of the compound with copper carbonate entrapped in a solid-phase reactor. It was found that the unsaturated complex of Cu(II) and benzoic acid (1:1) has strong catalytic effect on the luminol-H2O2 chemiluminescence reaction. The calibration graph is linear over the range of 0.025 ~ 60 g/mL of benzoic acid, with a relative standard deviation of less than 3.0 %, and the detection limit is 0.01礸穖L-1. The proposed method was applied to the determination of benzoic acid content in different pharmaceutical formulations.展开更多
Investigation of ultraweak emissions in the processes of chemiluminescence, CL, and electrochemiluminesce, ECL, requires special techniques of their recording and spectral analysis. From among the hitherto proposed me...Investigation of ultraweak emissions in the processes of chemiluminescence, CL, and electrochemiluminesce, ECL, requires special techniques of their recording and spectral analysis. From among the hitherto proposed methods of detection of the emission spectra of these processes, that of the cut-off filter was most sensitive. The usefulness of this method in interpretation of the CL and ECL systems of the quantum yields in the range 1×10^-9-1×10^-11 containing ions and complexes of Eu(Ⅲ), Tb(Ⅲ) and Dy0ID was shown. Exceptional character of the emission bands of lanthanide ions, being a result of the f-f electron transitions and in particular their low FWHM, permitted the appli- cation of the cut-off filter method to their analysis. The results obtained for CL and ECL on the basis of analysis of ultraweak emission proved to be successful in analytical applications. The systems containing Eu(Ⅲ) ions hydrated or complexed with organic ligands enabled inferring changes in the coordination sphere of the ions.展开更多
A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol...A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol-KMnO4 system, light emission caused by luminol-KMnO4 system was detected by the photomultiplier tube, and its intensity caused by the appearance of KMnO4 after sample digestion was inversely proportional to CODMn. Effects for CODMn determining such as pH, concentrations and interference were investigated in detail. A detection limit of 0.3 mg/L CODMn with a linear range of 0.3-200 mg/L for its theoretical CODMn was obtained under the optimized experimental conditions. The relative standard deviation was 4.3% for 5.0 mg/L CODMn (n = 11). This CL flow system for determining CODMn was simple, rapid, and suitable for automatic analysis. The data obtained by the present method were fairly in good agreement with those obtained by the standard titrimetric method. It has been applied to determine real samples with satisfactory results.展开更多
Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very power...Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very powerful analytical technique and has been widely used in such as clinical testing, biowarfare agent detection, and pharmaceutical analysis. This review focuses on the current trends of molecular recognition-based biosensing methods for pharmaceutical analysis since 2010. It introduces a background of ECL and presents the recent ECL developments in ECL immunoassay(ECLIA), immunosensors, enzyme-based biosensors, aptamer-based biosensors, and molecularly imprinted polymers(MIP)-based sensors. At last, the future perspective for these analytical methods is briefly discussed.展开更多
A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and H...A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and HCHO in sulfuric acid medium. Analytes were pre-concentrated on solid sorbents (C18 solid-phase extraction cartridges). Under the optimum conditions, the proposed method allows the measurement of resveratrol over the range of 1.32 × 10^-8 to 1.32 × 10^-5 mol/L with a detection limit of 3.30 ×10^-9 mol/L, and the relative standard deviation for 1.32 ×10^-5 mol/L resveratrol (n = 11) is 3.8%. This method has been successfully applied for the determination of the resveratrol in red wine. Furthermore, the possible reaction mechanism was also discussed.展开更多
A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELI...A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA).A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents,less total assay time,and better linearity,recovery,precision,sensitivity and validity.AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA,and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit.The correlation coefficient between MPs-CLEIA and ELISA was obtained with R 2 0.6703;however,the correlation between MPs-CLEIA and ECLIA (R 2 0.9582) was obviously better than that between colorimetric ELISA and ECLIA (R 2 0.6866).展开更多
The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination o...The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination of trace amount of molybdenum has been established. The emission intensity was linear with molybdenum concentration in the range of 0.1-1000 ng/mL; the detection limit was 0.02 ng/mL molybdenum; the relative standard deviation was less than 2% for the determination of 0.1 ng/mL molybdenum (n=11). The method has been applied successfully to the analysis of trace molybdenum in water and steel samples.展开更多
The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI) -chemiluminescence(CL) method is described. The method is based on the enhancing e...The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI) -chemiluminescence(CL) method is described. The method is based on the enhancing effect of methamidaphos on the CL reaction of luminol with hydrogen peroxide in an alkaline solution. Under the optimal conditions, the CL intensity is linear to the methamidaphos mass concentration in a range of 0. 2-13μg/mL ( r= 0. 9992). The detection limit(3σ) is 0. 047μg/mL. The relative standard deviations for the analysis of three samples are 1.8%, 2.5% and 3.7% ( n = 5 ), respectively. The recovery is in a range of 90%-109% by the method. In this work, this method was successfully applied to the determination of the methamidaphos residue on some vegetable samples.展开更多
The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CP...The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CPL)and hydrochlorothiazide(HCT).The stopped-flow technique in a continuous-flow system was employed in this work in order to emphasize the kinetic differences between the two analytes in cerium(IV)-rhodamine 6G CL system.After the flow was stopped,an initial rise of CL signal was observed for HCT standards,while a direct decay of CL signal was obtained for CPL standards.The mixed CL signal was monitored and recorded on the whole process of continuous-flow/stopped-flow,and the obtained data were processed by the chemometric approach of artificial neural network.The relative prediction error(RPE)of CPL and HCT was 5.9% and 8.7%,respectively.The recoveries of CPL and HCT in tablets were found to fall in the range between 95% and 106%.The proposed method was successfully applied to the simultaneous determination of CPL and HCT in a compound pharmaceutical formulation.展开更多
Objective: To identify serodiagnosis and quantification of Toxoplasma gondii(T. gondii) infection among pregnant women in Salmas, northwest of Iran. Methods: In this crosssectional study, 276 blood samples were collec...Objective: To identify serodiagnosis and quantification of Toxoplasma gondii(T. gondii) infection among pregnant women in Salmas, northwest of Iran. Methods: In this crosssectional study, 276 blood samples were collected from pregnant women referred to the health care centers in Salmas city. The demographic variables were also recorded. Titers of antiToxoplasma IgM and IgG antibodies(Ab) were determined using the chemiluminescence immunoassay. Quantitative real-time PCR targeting the T. gondii repeated element gene was also performed on the blood sample. Results: Out of all, 19.92%(55/276) and 2.17%(6/276) patients were seropositive for anti-Toxoplasma IgG and IgM Ab, respectively. Moreover, the presence of T. gondii DNA was observed in 12.31%(34/276) blood samples. A significant relationship was observed between the IgG Ab seropositivity and contact with the cat as a risk factor(P=0.022). Conclusions: The seroprevalence rate of T. gondii infection in pregnant women is relatively low. Consequently, the seronegative pregnant women are at risk, and a considerable rate of positive blood samples for the presence of parasite's DNA should not be ignored. Besides, quantitative real-time PCR could be considered as an accurate method for diagnosis of acute toxoplasmosis especially when the precise results are of the most importance in pregnancy. Limiting contact with cats is also suggested for pregnant women.展开更多
A new method for the determination of baicalin with HPLC-CL was developed. The method was based on the chemiluminescence reaction between KMnO4 and baicalin sensitized from HCHO. The linear range was 3.7?0-6~9.8?0-5...A new method for the determination of baicalin with HPLC-CL was developed. The method was based on the chemiluminescence reaction between KMnO4 and baicalin sensitized from HCHO. The linear range was 3.7?0-6~9.8?0-5 mol/L with detection limit of 1.7?0-6 mol/L and the relative standard deviation was 2.5 % (Cs=6.6?0-5 mol/L, n=5). The method has been applied to the determination of baicalin in oral administration, injection, Scutellariae radix and granules with good results.展开更多
Based on the fact that some metal ions can catalyze the chemiluminescence(CL)reaction of luminol with K_3Fe(CN)_6,a novel capillary electrophoresis CL method was developed for the determination of Co(Ⅱ)and Cu(Ⅱ).The...Based on the fact that some metal ions can catalyze the chemiluminescence(CL)reaction of luminol with K_3Fe(CN)_6,a novel capillary electrophoresis CL method was developed for the determination of Co(Ⅱ)and Cu(Ⅱ).The separation was carried out with a 10 mmol/L sodium acetate solution containing 0.8 mmol/L luminol and 2.0 mmol/Lα-HIBA(adjusted to pH 4.8 by HAc solution).The post-capillary reagent was 2.0 mmol/L K_3Fe(CN)_6 which was adjusted to pH 13.0 by NaOH solution.Under the optimum conditions,the detection limits(S/N=3)for Co(Ⅱ)and Cu(Ⅱ)were 7.5×10^(-11)mol/L and 7.5×10^(-9)mol/L,with the linear range of 7.5×10^(-9)mol/L to 1.0×10^(-6)mol/L and 7.5×10^(-8)mol/L to 5.0×10^(-5)mol/L, respectively.展开更多
The generation and transformation of radicals on the cathode of indirect electrochemical oxidation were studied by chemilumines- cence(CL)and UV-Visible spectra in the reactor with a salt bridge that connected the sep...The generation and transformation of radicals on the cathode of indirect electrochemical oxidation were studied by chemilumines- cence(CL)and UV-Visible spectra in the reactor with a salt bridge that connected the separated chambers.The CL intensity of 4×10^(-9)mol/L luminol on the cathode with bubbling oxygen was about seven times that of the intensity without it,which was because of the generation of reactive oxygen species(ROS).The existence of ROS,especially the generation of the superoxide radical,coul...展开更多
A robust, selective and highly sensitive chemiluminescent (CL) platform for protein assay was presented in this paper. This novel CL approach utilized rolling circle amplification (RCA) as a signal enhancement tec...A robust, selective and highly sensitive chemiluminescent (CL) platform for protein assay was presented in this paper. This novel CL approach utilized rolling circle amplification (RCA) as a signal enhancement technique and the 96-well plate as the immobilization and separation carrier. Typically, the antibody immobilized on the surface of 96-well plate was sandwiched with the protein target and the aptamer-primer sequence. This aptamer-primer sequence was then employed as the primer of RCA. Based on this design, a number of the biotinylated probes and streptavidin-horseradish peroxidase (SA-HRP) were captured on the plate, and the CL signal was amplified. In summary, our results demonstrated a robust biosensor with a detection limit of 10 fM that is easy to be established and utilized, and devoid of light source. Therefore, this new technique .will broaden the perspective for future development of DNA-based biosensors for the detection of other protein biomarkers related to clinical diseases, by taking advantages of high sensitivity and selectivity.展开更多
This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitiz...This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitized by gossypol. Under the optimum conditions, the CL intensity is proportional to the concentration of gossypol over the range of 1.11×10^-17-2.78×10^-16 mol/L in acid solution and 8.00×10^-11-7.39×10^-8mol/L in neutral solution with correlation coefficients 0.9983 and 0.9905, respectively. The detection limits is 1.60×10^-18 mol/L (S/N=3). The proposed method has been applied for the determination of the gossypol in cottonseeds and pharmaceutical formulations with satisfactory results.展开更多
It was found that 20 amino acids could inhibit the intensity of the luminol-H_2O_2-CuSO_4 chemiluminescence system.Using this character,a rapid and sensitive method for the determination of 20 amino acids was develope...It was found that 20 amino acids could inhibit the intensity of the luminol-H_2O_2-CuSO_4 chemiluminescence system.Using this character,a rapid and sensitive method for the determination of 20 amino acids was developed with flow injection coupled with chemiluminescence detection.Under the optimal conditions,the detection limits of 20 amino acids were in the range of 4.5×10^(-7)- 4.3×10^(-10) mol/L,and the relative standard deviations were less than 3.2%.The proposed method was successfully applied to drug analysis.The possible mechanism was also discussed.展开更多
To develop a quantitative method for methylation analysis of the p16 gene based on mismatch hybridization and chemiluminescence. Methods Genomic DNA was modified by sodium bisulfite to convert all unmethylated but no...To develop a quantitative method for methylation analysis of the p16 gene based on mismatch hybridization and chemiluminescence. Methods Genomic DNA was modified by sodium bisulfite to convert all unmethylated but not methylated cytosines to uracil, and subsequently a pair of primer having no CpG sites was designed for amplification target DNA containing methylated or unmethylated CpG sites. The PCR product spanning CpG sites were hybridized with two oligonucleotide probes which perfectly matched the methylated and unmethylated CpG sequences respectively, and the hybrids were detected by chemiluminescent method. The percentage of methylated target sequences could be estimated by calculating the ratio of signals obtained with two probes. Results The percentage of methylation of artificial mixtures DNA showed a linear relation. There was a negative correlation between the methyaltion index with p16 transcriptional mRNA of p16 gene in tumor cell lines. Conclusion Compared with existing methods, this assay is nonisotopic, rapid, simple, and can be widely applied to the study of DNA methylation.展开更多
文摘BACKGROUND Antinuclear antibodies(ANAs)are crucial in diagnosing autoimmune diseases,mainly systemic lupus erythematosus(SLE).This study aimed to compare the performance of chemiluminescence assay(CLIA)and line immunoassay(LIA)in detecting ANAs in patients with autoimmune diseases,evaluate their diagnostic accuracy for SLE,and develop a novel diagnostic model using CLIA-detected antibodies for SLE.Specimens from patients with autoimmune diseases and physical examination specimens were collected to parallel detect specific antibodies.Individual antibodies'diagnostic performance and a model combining multiple antibodies were assessed.The findings provide valuable insights into improving the diagnosis of SLE through innovative approaches.AIM To compare the performance of CLIA and LIA in detecting ANAs in patients with autoimmune diseases,assess their accuracy for SLE,and develop a novel diagnostic model using CLIA-detected antibodies for SLE.METHODS Specimens have been obtained from 270 patients with clinically diagnosed autoimmune disorders,as well as 130 physical examination specimens.After that,parallel detection of anti-double-stranded DNA(dsDNA)antibody,anti-histone(Histone)antibody,anti-nucleosome(Nuc)antibody,anti-Smith(Sm)antibody,anti-ribosomal P protein(Rib-P)antibody,anti-sicca syndrome A(Ro60)antibody,anti-sicca syndrome A(Ro52)antibody,anti-sicca syndrome(SSB)antibody,anticentromere protein B(Cenp-B)antibody,anti-DNA topoisomerase 1(Scl-70)antibody,anti-histidyl tRNA synthetase(Jo-1)antibody,and anti-mitochondrial M2(AMA-M2)antibody was performed using CLIA and LIA.The detection rates,compliance rates,and diagnostic performance for SLE were compared between the two methodologies,followed by developing a novel diagnostic model for SLE.RESULTS CLIA and LIA exhibited essentially comparable detection rates for anti-dsDNA antibody,anti-Histone antibody,anti-Nuc antibody,anti-Sm antibody,anti-Rib-P antibody,anti-Ro60 antibody,anti-Ro52 antibody,anti-SSB antibody,anti-Cenp-B antibody,anti-DNAScl-70 antibody,anti-Jo-1 antibody and anti-AMA-M2 antibody(P>0.05).The two methods displayed identical results for the detection of anti-dsDNA antibody,anti-Histone antibody,anti-Nuc antibody,anti-Sm antibody,anti-Ro60 antibody,anti-Ro52 antibody,anti-SSB antibody,anti-Cenp-B antibody,anti-Scl-70 antibody,and anti-AMA-M2 antibody(Kappa>0.7,P<0.05),but showed a moderate agreement for the detection of anti-Rib-P antibody and anti-Jo-1 antibody(Kappa=0.671 and 0.665;P<0.05).In addition,the diagnostic performance of these antibodies detected by both methods was similar for SLE.The diagnostic model's area under the curve values,sensitivity,and specificity,including an anti-dsDNA antibody and an anti-Ro60 antibody detected by CLIA,were 0.997,0.962,and 0.978,respectively.These values were higher than the diagnostic performance of individual antibodies.CONCLUSION CLIA and LIA demonstrated excellent overall consistency in detecting ANA profiles.A diagnostic model based on CLIA-detected antibodies can successfully contribute to developing a novel technique for detecting SLE.
文摘A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium permanganate in a hydrochloric acid medium, enhanced by formaldehyde (HCHO). Under optimum conditions, calibration curve over the range of 1.0-20.0μg/mL was obtained. The proposed method was successfully applied to the determination of meloxicam in capsules with no evi- dence of interference from common excipients. The detection limit of this method was 25.6 ng/mL. The relative standard deviation was 2.1% for 10.0 μg/mL meloxicam. The sample throughput was found to be 120 samples/h.
文摘A new chemiluminescence flow system has been developed for sequential determina-tion of benzoic acid based on the reaction of the compound with copper carbonate entrapped in a solid-phase reactor. It was found that the unsaturated complex of Cu(II) and benzoic acid (1:1) has strong catalytic effect on the luminol-H2O2 chemiluminescence reaction. The calibration graph is linear over the range of 0.025 ~ 60 g/mL of benzoic acid, with a relative standard deviation of less than 3.0 %, and the detection limit is 0.01礸穖L-1. The proposed method was applied to the determination of benzoic acid content in different pharmaceutical formulations.
基金support from the Polish Ministry of Science and Higher EducationGrant N N204 028236
文摘Investigation of ultraweak emissions in the processes of chemiluminescence, CL, and electrochemiluminesce, ECL, requires special techniques of their recording and spectral analysis. From among the hitherto proposed methods of detection of the emission spectra of these processes, that of the cut-off filter was most sensitive. The usefulness of this method in interpretation of the CL and ECL systems of the quantum yields in the range 1×10^-9-1×10^-11 containing ions and complexes of Eu(Ⅲ), Tb(Ⅲ) and Dy0ID was shown. Exceptional character of the emission bands of lanthanide ions, being a result of the f-f electron transitions and in particular their low FWHM, permitted the appli- cation of the cut-off filter method to their analysis. The results obtained for CL and ECL on the basis of analysis of ultraweak emission proved to be successful in analytical applications. The systems containing Eu(Ⅲ) ions hydrated or complexed with organic ligands enabled inferring changes in the coordination sphere of the ions.
基金This work was supported by the National Natural Science Foundation of China (No. 20005005) the Chenguang Project of Wuhan City (No. 20005004026).
文摘A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol-KMnO4 system, light emission caused by luminol-KMnO4 system was detected by the photomultiplier tube, and its intensity caused by the appearance of KMnO4 after sample digestion was inversely proportional to CODMn. Effects for CODMn determining such as pH, concentrations and interference were investigated in detail. A detection limit of 0.3 mg/L CODMn with a linear range of 0.3-200 mg/L for its theoretical CODMn was obtained under the optimized experimental conditions. The relative standard deviation was 4.3% for 5.0 mg/L CODMn (n = 11). This CL flow system for determining CODMn was simple, rapid, and suitable for automatic analysis. The data obtained by the present method were fairly in good agreement with those obtained by the standard titrimetric method. It has been applied to determine real samples with satisfactory results.
文摘Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very powerful analytical technique and has been widely used in such as clinical testing, biowarfare agent detection, and pharmaceutical analysis. This review focuses on the current trends of molecular recognition-based biosensing methods for pharmaceutical analysis since 2010. It introduces a background of ECL and presents the recent ECL developments in ECL immunoassay(ECLIA), immunosensors, enzyme-based biosensors, aptamer-based biosensors, and molecularly imprinted polymers(MIP)-based sensors. At last, the future perspective for these analytical methods is briefly discussed.
文摘A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and HCHO in sulfuric acid medium. Analytes were pre-concentrated on solid sorbents (C18 solid-phase extraction cartridges). Under the optimum conditions, the proposed method allows the measurement of resveratrol over the range of 1.32 × 10^-8 to 1.32 × 10^-5 mol/L with a detection limit of 3.30 ×10^-9 mol/L, and the relative standard deviation for 1.32 ×10^-5 mol/L resveratrol (n = 11) is 3.8%. This method has been successfully applied for the determination of the resveratrol in red wine. Furthermore, the possible reaction mechanism was also discussed.
基金supported by the National Basic Research Program of China (973 Program,no. 2007CB714507)National Nature Science Foundation of China (no. 90813015)
文摘A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA).A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents,less total assay time,and better linearity,recovery,precision,sensitivity and validity.AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA,and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit.The correlation coefficient between MPs-CLEIA and ELISA was obtained with R 2 0.6703;however,the correlation between MPs-CLEIA and ECLIA (R 2 0.9582) was obviously better than that between colorimetric ELISA and ECLIA (R 2 0.6866).
文摘The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination of trace amount of molybdenum has been established. The emission intensity was linear with molybdenum concentration in the range of 0.1-1000 ng/mL; the detection limit was 0.02 ng/mL molybdenum; the relative standard deviation was less than 2% for the determination of 0.1 ng/mL molybdenum (n=11). The method has been applied successfully to the analysis of trace molybdenum in water and steel samples.
文摘The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI) -chemiluminescence(CL) method is described. The method is based on the enhancing effect of methamidaphos on the CL reaction of luminol with hydrogen peroxide in an alkaline solution. Under the optimal conditions, the CL intensity is linear to the methamidaphos mass concentration in a range of 0. 2-13μg/mL ( r= 0. 9992). The detection limit(3σ) is 0. 047μg/mL. The relative standard deviations for the analysis of three samples are 1.8%, 2.5% and 3.7% ( n = 5 ), respectively. The recovery is in a range of 90%-109% by the method. In this work, this method was successfully applied to the determination of the methamidaphos residue on some vegetable samples.
基金supported by the National Natural Science Foundation of China(No.20675063)
文摘The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CPL)and hydrochlorothiazide(HCT).The stopped-flow technique in a continuous-flow system was employed in this work in order to emphasize the kinetic differences between the two analytes in cerium(IV)-rhodamine 6G CL system.After the flow was stopped,an initial rise of CL signal was observed for HCT standards,while a direct decay of CL signal was obtained for CPL standards.The mixed CL signal was monitored and recorded on the whole process of continuous-flow/stopped-flow,and the obtained data were processed by the chemometric approach of artificial neural network.The relative prediction error(RPE)of CPL and HCT was 5.9% and 8.7%,respectively.The recoveries of CPL and HCT in tablets were found to fall in the range between 95% and 106%.The proposed method was successfully applied to the simultaneous determination of CPL and HCT in a compound pharmaceutical formulation.
基金supported by Infectious and Tropical Disease Research Center,Tabriz University of Medical Sciences,Tabriz,Iran(Grant No.94/2-5/17)
文摘Objective: To identify serodiagnosis and quantification of Toxoplasma gondii(T. gondii) infection among pregnant women in Salmas, northwest of Iran. Methods: In this crosssectional study, 276 blood samples were collected from pregnant women referred to the health care centers in Salmas city. The demographic variables were also recorded. Titers of antiToxoplasma IgM and IgG antibodies(Ab) were determined using the chemiluminescence immunoassay. Quantitative real-time PCR targeting the T. gondii repeated element gene was also performed on the blood sample. Results: Out of all, 19.92%(55/276) and 2.17%(6/276) patients were seropositive for anti-Toxoplasma IgG and IgM Ab, respectively. Moreover, the presence of T. gondii DNA was observed in 12.31%(34/276) blood samples. A significant relationship was observed between the IgG Ab seropositivity and contact with the cat as a risk factor(P=0.022). Conclusions: The seroprevalence rate of T. gondii infection in pregnant women is relatively low. Consequently, the seronegative pregnant women are at risk, and a considerable rate of positive blood samples for the presence of parasite's DNA should not be ignored. Besides, quantitative real-time PCR could be considered as an accurate method for diagnosis of acute toxoplasmosis especially when the precise results are of the most importance in pregnancy. Limiting contact with cats is also suggested for pregnant women.
文摘A new method for the determination of baicalin with HPLC-CL was developed. The method was based on the chemiluminescence reaction between KMnO4 and baicalin sensitized from HCHO. The linear range was 3.7?0-6~9.8?0-5 mol/L with detection limit of 1.7?0-6 mol/L and the relative standard deviation was 2.5 % (Cs=6.6?0-5 mol/L, n=5). The method has been applied to the determination of baicalin in oral administration, injection, Scutellariae radix and granules with good results.
文摘Based on the fact that some metal ions can catalyze the chemiluminescence(CL)reaction of luminol with K_3Fe(CN)_6,a novel capillary electrophoresis CL method was developed for the determination of Co(Ⅱ)and Cu(Ⅱ).The separation was carried out with a 10 mmol/L sodium acetate solution containing 0.8 mmol/L luminol and 2.0 mmol/Lα-HIBA(adjusted to pH 4.8 by HAc solution).The post-capillary reagent was 2.0 mmol/L K_3Fe(CN)_6 which was adjusted to pH 13.0 by NaOH solution.Under the optimum conditions,the detection limits(S/N=3)for Co(Ⅱ)and Cu(Ⅱ)were 7.5×10^(-11)mol/L and 7.5×10^(-9)mol/L,with the linear range of 7.5×10^(-9)mol/L to 1.0×10^(-6)mol/L and 7.5×10^(-8)mol/L to 5.0×10^(-5)mol/L, respectively.
文摘The generation and transformation of radicals on the cathode of indirect electrochemical oxidation were studied by chemilumines- cence(CL)and UV-Visible spectra in the reactor with a salt bridge that connected the separated chambers.The CL intensity of 4×10^(-9)mol/L luminol on the cathode with bubbling oxygen was about seven times that of the intensity without it,which was because of the generation of reactive oxygen species(ROS).The existence of ROS,especially the generation of the superoxide radical,coul...
基金financial support from the National Drug Innovative Program (2009ZX09301-011)the Research Fund for the Doctoral Program of Higher Education (200802461096,20090071110056)
文摘A robust, selective and highly sensitive chemiluminescent (CL) platform for protein assay was presented in this paper. This novel CL approach utilized rolling circle amplification (RCA) as a signal enhancement technique and the 96-well plate as the immobilization and separation carrier. Typically, the antibody immobilized on the surface of 96-well plate was sandwiched with the protein target and the aptamer-primer sequence. This aptamer-primer sequence was then employed as the primer of RCA. Based on this design, a number of the biotinylated probes and streptavidin-horseradish peroxidase (SA-HRP) were captured on the plate, and the CL signal was amplified. In summary, our results demonstrated a robust biosensor with a detection limit of 10 fM that is easy to be established and utilized, and devoid of light source. Therefore, this new technique .will broaden the perspective for future development of DNA-based biosensors for the detection of other protein biomarkers related to clinical diseases, by taking advantages of high sensitivity and selectivity.
基金financial support from the National Natural Science Foundation of China(Grant No.20075017)and from Tianjin Normal University.
文摘This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitized by gossypol. Under the optimum conditions, the CL intensity is proportional to the concentration of gossypol over the range of 1.11×10^-17-2.78×10^-16 mol/L in acid solution and 8.00×10^-11-7.39×10^-8mol/L in neutral solution with correlation coefficients 0.9983 and 0.9905, respectively. The detection limits is 1.60×10^-18 mol/L (S/N=3). The proposed method has been applied for the determination of the gossypol in cottonseeds and pharmaceutical formulations with satisfactory results.
基金supported by the National Natural Science Foundation of China(No.20575056)Henan Innovation Project for University Research Talents(No.2005126)Natural Science Foundation of Henan Province of China (No.092300410122).
文摘It was found that 20 amino acids could inhibit the intensity of the luminol-H_2O_2-CuSO_4 chemiluminescence system.Using this character,a rapid and sensitive method for the determination of 20 amino acids was developed with flow injection coupled with chemiluminescence detection.Under the optimal conditions,the detection limits of 20 amino acids were in the range of 4.5×10^(-7)- 4.3×10^(-10) mol/L,and the relative standard deviations were less than 3.2%.The proposed method was successfully applied to drug analysis.The possible mechanism was also discussed.
基金This work was supported by the National Natural Science Foundation of China (Grant No. 39990570).
文摘To develop a quantitative method for methylation analysis of the p16 gene based on mismatch hybridization and chemiluminescence. Methods Genomic DNA was modified by sodium bisulfite to convert all unmethylated but not methylated cytosines to uracil, and subsequently a pair of primer having no CpG sites was designed for amplification target DNA containing methylated or unmethylated CpG sites. The PCR product spanning CpG sites were hybridized with two oligonucleotide probes which perfectly matched the methylated and unmethylated CpG sequences respectively, and the hybrids were detected by chemiluminescent method. The percentage of methylated target sequences could be estimated by calculating the ratio of signals obtained with two probes. Results The percentage of methylation of artificial mixtures DNA showed a linear relation. There was a negative correlation between the methyaltion index with p16 transcriptional mRNA of p16 gene in tumor cell lines. Conclusion Compared with existing methods, this assay is nonisotopic, rapid, simple, and can be widely applied to the study of DNA methylation.