期刊文献+
共找到30篇文章
< 1 2 >
每页显示 20 50 100
Mass Transfer Enhancement of Gas Absorption by Adding the Dispersed Organic Phases 被引量:9
1
作者 张志刚 许天行 +2 位作者 李文秀 纪智玲 许光荣 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第6期1066-1068,共3页
Mass transfer enhancement of gas absorption by adding a dispersed organic phase has been studied in this work. Various dispersed organic phases (heptanol, octanol, isoamyl alcohol, heptane, octane, and isooctane) we... Mass transfer enhancement of gas absorption by adding a dispersed organic phase has been studied in this work. Various dispersed organic phases (heptanol, octanol, isoamyl alcohol, heptane, octane, and isooctane) were tested respectively in the experiment. According to the theoretical model and experimental data, the overall volumetric mass transfer coefficient and enhancement factor were obtained under different dispersed organic phase volume fraction and stirring speed. The experimental results indicate that gas-liquid mass transfer is enhanced at different level by adding a dispersed organic phase. The best performance of enhancement were achieved with the dispersed organic phase volumetric fraction of 5% and under an intermediate stirring speed of 670 r·min^-1. Among the organic phases tested in the experiment, alcohols show better performance, which gave 20% higher enhance-ment of overall volumetric mass transfer coefficient than adding alkanes. 展开更多
关键词 gas absorption dispersed organic phase enhancement factor the interfacial area
下载PDF
Prediction of dispersed phase holdup in pulsed disc and doughnut solvent extraction columns under different mass transfer conditions 被引量:3
2
作者 Yong Wang Kathryn H.Smith +3 位作者 Kathryn Mumford Teobaldo F.Grabin Zheng Li Geoffrey W.Stevens 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第2期226-231,共6页
Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is present... Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is presented. Pulsed disc and doughnut solvent extraction columns (PDDC) have been used for a range of important applications such as ura- nium extraction and nuclear fuel recycling. Although the dispersed phase holdup in a PDDC has been presented by some researchers, there is still the need to develop a robust correlation that can predict the experimental dispersed phase holdup over a range of operating conditions including the effects of mass transfer direction. In this study, dis- persed phase holdup data from different literature sources for a PDDC were used to refit constants for the correlation presented by Kumar and Hartland lind. Eng. Chem. Res.,27 (1988),131-138] which did not consider the effect of col- umn geometry. In order to incorporate the characteristic length of the PDDC (i.e. the plate spacing), the unified cor- relation for holdup proposed by Kumar and Hartland based on data from eight different types of columns [Ind. Eng. Chem. Res.,34 (1995) 3925-3940] was refitted to the PDDC data. New constants have been presented for each hold- up correlation for a PDDC based on regression analysis using published holdup data from PDDCs that cover a range of onerating conditions and nhwical nronerties and consider the direction of mass transfer. 展开更多
关键词 Solvent extraction Liquid extraction Pulsed disc and doughnut columns Solvent extraction column design Holdup dispersed phase holdup Hydrodynamics of extraction columns
下载PDF
New Dispersed Phase of Electrorheological Fluids:TiO_2 Coating Graphite Particles 被引量:2
3
作者 Sujuan XU+ and Biao WANG (Harbin Institute of Technology, Harbin 150001, China) Shouqiang MEN and Kunquan LU (Institute of Physics, Chinese Academy of Sciences, Beijing 100080, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第5期529-530,共2页
We have prepared novel coated particles, with a conductor graphite core and a dielectric TiO2 coating, as the dispersed phase of electrorheological fluids. One order of magnitude enhancement in the shear stress is obt... We have prepared novel coated particles, with a conductor graphite core and a dielectric TiO2 coating, as the dispersed phase of electrorheological fluids. One order of magnitude enhancement in the shear stress is obtained by using such composite particles, when it is compared with that of TiO2 particles. The experimental results show a way to get excellent ER system. 展开更多
关键词 New dispersed phase of Electrorheological Fluids GRAPHITE TIO
下载PDF
EFFECT OF DISPERSED PHASE PARTICLES ON ELECTRICAL CONDUCTION OF PEO-NaSCN
4
《Chemical Research in Chinese Universities》 SCIE CAS 1986年第1期97-101,共5页
Fast ionic conductors are one kind of solid state material with ionic conductivity as high as that of melten salts or liquid electrolytes.Ionic conductivity is one of the important parameters for characterizing a fast... Fast ionic conductors are one kind of solid state material with ionic conductivity as high as that of melten salts or liquid electrolytes.Ionic conductivity is one of the important parameters for characterizing a fast ionic conductor.For a long time materialists and chemists have made great efforts in search of new fast ionic conductors with high ionic conductivity.In view of structure,they have synthesised silver and copper fast ionic conductors with so called open structures.But it is not so successful for searching more applicable alkaline fast ionic conductors.Since polymer has flexibility for making thin film,it concentrates attention on the polymer-alkaline salt complex.Fenton et al.have first reported poly(ethylene oxide) (PEO)-alkaline salt complex.Later on Armard et al.have investigated the electrical property of PEO-NaSCN. 展开更多
关键词 OC PEO EFFECT OF disperseD phase PARTICLES ON ELECTRICAL CONDUCTION OF PEO-NaSCN
下载PDF
A WEAKLY NONLINEAR WATER WAVE MODEL TAKING INTO ACCOUNT DISPERSION OF WAVE PHASE VELOCITY 被引量:1
5
作者 李瑞杰 李东永 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2002年第2期107-112,共6页
This paper presents a weakly nonlinear water wave model using a mild slope equation and a new explicit formulation which takes into account dispersion of wave phase velocity, approximates Hedges’ (1987) nonlinear dis... This paper presents a weakly nonlinear water wave model using a mild slope equation and a new explicit formulation which takes into account dispersion of wave phase velocity, approximates Hedges’ (1987) nonlinear dispersion relationship, and accords well with the original empirical formula. Comparison of the calculating results with those obtained from the experimental data and those obtained from linear wave theory showed that the present water wave model considering the dispersion of phase velocity is rational and in good agreement with experiment data. 展开更多
关键词 dispersion of phase velocity explicit non-linear dispersion relation water wave mild slope equation
原文传递
Detection of Tetracycline Antibiotics in Water by Dispersive Micro-solid Phase Extraction using Fe_(3)O_(4)@[Cu_(3)(btc)_(2)]Magnetic Composite Combined with Liquid Chromatography-Tandem Mass Spectrometry 被引量:2
6
作者 Yan-ni Li Yan-yun Hu +2 位作者 Lei Ding Dian-bing Zhou Wen-jun Chen 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2021年第2期238-248,I0002,共12页
Residues of tetracycline antibiotics(TCs) in environments may be harmful to human.Due to their high polarities,it is extremely challenging to efficiently enrich TCs with low concentrations in natural waters for analys... Residues of tetracycline antibiotics(TCs) in environments may be harmful to human.Due to their high polarities,it is extremely challenging to efficiently enrich TCs with low concentrations in natural waters for analysis.In this work,a magnetic metal-organic framework Fe_(3)O_(4)@[Cu_(3)(btc)_(2)]was synthesized and applied as a dispersive micro-solid phase extraction adsorbent for TCs enrichment.Effects of dispersive micro-solid phase extraction conditions including extraction time,solution p H,and elution solvent on the extraction efficiencies of TCs were investigated.Results show that TCs could be enriched efficiently by Fe_(3)O_(4)@[Cu_(3)(btc)_(2)],and electrostatic interaction between TCs and Fe_(3)O_(4)@[Cu_(3)(btc)_(2)]dominated this process.Combined with liquid chromatography-tandem mass spectrometry,four TCs residues (oxytetracycline,tetracycline,chlortetracycline,and doxycycline) in natural waters were determined.The detection limits (LOD,S/N=3) of the four antibiotics were 0.01-0.02μg/L,and the limits of quantitation (LOQ,S/N=10)were 0.04-0.07μg/L.The recoveries obtained from river water and aquaculture water spiked with three TCs concentration levels ranged from 70.3%to 96.5%with relative standard deviations of 3.8%-12.8%.Results indicate that the magnetic metal-organic framework based dispersive micro-solid phase extraction is simple,rapid and high-loading for antibiotics enrichment from water,which further expand the practical application of metal-organic frameworks in sample pretreatment for environmental pollutant analysis. 展开更多
关键词 Fe_(3)O_(4)@[Cu_(3)(btc)_(2)] Metal-organic frameworks Dispersive micro-solid phase extraction Tetracycline
下载PDF
Property and Activity of Molybdates Dispersed on Silica Obtained from Various Synthetic Procedures 被引量:1
7
作者 Antonella Gervasini Laura Wahba +1 位作者 Manuel Dario Finol Jean-Francois Lamonier 《Materials Sciences and Applications》 2012年第4期195-212,共18页
The synthesis and characterization of several dispersed molybdena catalysts on silica support (MoO3-SiO2) prepared from a variety of precursors (Mo(VI)-acetylacetonate, oxo-peroxo Mo-species, hydrated ammonium heptamo... The synthesis and characterization of several dispersed molybdena catalysts on silica support (MoO3-SiO2) prepared from a variety of precursors (Mo(VI)-acetylacetonate, oxo-peroxo Mo-species, hydrated ammonium heptamolybdate) and preparation methods (deposition of the Mo-phase on finite SiO2 support by aqueous and methanol impregnations, by adsorption, by oxo-peroxo route-like, and by one-step synthesis of MoO3-SiO2 system with molecular precursors) are presented. The molybdena concentration on silica was comprised in a large interval (1.5 - 14 wt%) depending on the preparation method which governed the Mo-loading on silica. Convenient comparisons among samples at similar Mo-concentration have been made discussing the morphologic-structural (XRD, XPS, UV-vis-DRS, and N2-adsorption) and physicochemical (TG-DTG, TPR, and n-butylamine-TPD) sample properties. Polymeric octahedral polymolybdate aggregates predominated in the samples prepared by aqueous and methanol impregnations, which were at high Mo-concentration. On the contrary, isolated Mo(VI) species in distorted Td symmetry predominated in the sample prepared by adsorption which was at very low Mo-concentration. The sample acidity was composed of a weak acidy site population, associated with the silica support, and a strong acid site population associated with the Mo-dispersed phase. Oxidation tests of formaldehyde, an oxygen-containing VOC (Volatile Organic Compound), were performed to determine the prevalent redox or acidic function of the Mo-species at the surface of the catalysts. 展开更多
关键词 Molybdena-Silica Mixed Oxides Molybdenum dispersed phase Catalyst Preparation Catalyst Characterization Catalytic Oxidation FORMALDEHYDE
下载PDF
Phase dispersion of Raman and Rayleigh-enhanced four-wave mixings in femtosecond polarization beats
8
作者 赵燕 聂志强 +5 位作者 李昌彪 张彦鹏 甘琛利 郑淮斌 李院院 卢克清 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第6期2340-2351,共12页
Based on color-locking noisy field correlation in three Markovian stochastic models, phase dispersions of the Raman- and Rayleigh-enhanced four-wave mixing (FWM) have been investigated. The phase dispersions are mod... Based on color-locking noisy field correlation in three Markovian stochastic models, phase dispersions of the Raman- and Rayleigh-enhanced four-wave mixing (FWM) have been investigated. The phase dispersions are modified by both linewidth and time delay for negative time delay, but only by linewidth for positive time delay. Moreover, the results under narrowband condition are close to the nonmodified nonlinear dispersion and absorption of the material. Homodyne and heterodyne detections of the Raman, the Rayleigh and the mixing femtosecond difference-frequency polarization beats have also been investigated, separately. 展开更多
关键词 phase dispersion RAMAN RAYLEIGH four-wave mixing
原文传递
Determination of Tebuconazole Residue in Apples and Vegetables by Matrix Solid Phase Dispersion-Gas Chromatography
9
作者 Peng Cao Yunjie Ma +2 位作者 Yue Cao Jianyun Wang Yangzi Wang 《Meteorological and Environmental Research》 CAS 2013年第7期26-27,31,共3页
[ Objective] The study aimed to determine tebuconazole residue in apples and vegetables using matrix solid phase dispersion-gas chro- matography (MSPD-GC). [ Method] The effects of extraction and determination condi... [ Objective] The study aimed to determine tebuconazole residue in apples and vegetables using matrix solid phase dispersion-gas chro- matography (MSPD-GC). [ Method] The effects of extraction and determination conditions on the detection of tebuconazole left in apples and veg- etables were analyzed, and the optimum extraction conditions were determined. [ Result] The recovery rate of tebucenazole was the highest when the ratio of a sample to florisil dispersant was 1 : 4, and the mixture of hexane and acetone ( 1 : 1 ) with total volume of 8 ml was as the eluant. Under the optimum conditions, the relative standard deviation (RSD) of the method was 4.9% -7.6%, and the detection limit was 0.1 tJg/g, while the re- covery rate of tebuconazole changed from 86.7% to 95. 2% . [ Conclusion] The method was simple, accurate, sensitive and applicable to the de- termination of tebuconazole in aaricultural Droducts. 展开更多
关键词 Matrix solid phase dispersion Gas chromatography TEBUCONAZOLE Apples VEGETABLES China
下载PDF
Determination of seven active components in Salvia miltiorrhiza herb by matrix solid phase dispersion combined with ion liquid extraction followed by high performance liquid chromatography
10
作者 Bo Hong Yanping Wang +1 位作者 Yinglong Han Wenjing Li 《Asian Journal of Traditional Medicines》 CAS 2021年第2期83-97,共15页
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de... A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples. 展开更多
关键词 high performance liquid chromatography(HPLC) silica gel supported ionic liquid(SGSIL) matrix solid phase dispersion(MSPD) Salvia miltiorrhiza(SM) DETERMINATION
下载PDF
Joint Angle Correction in Rheumatoid Arthritis and Its Reliability Analysis Based on Phase Dispersion Quantification
11
作者 Yafei Ou Prasoon Ambalathankandy +2 位作者 Ryunosuke Furuya Tamotsu Kamishima Masayuki Ikebe 《Open Journal of Medical Imaging》 2022年第4期171-179,共9页
Background: Rheumatoid arthritis is a form of autoimmune disease characterized by synovitis that can ultimately cause joint deformities and impaired functioning. The cartilage destruction is one of the most important ... Background: Rheumatoid arthritis is a form of autoimmune disease characterized by synovitis that can ultimately cause joint deformities and impaired functioning. The cartilage destruction is one of the most important indicators for diagnosis and treatment of rheumatoid arthritis, and it is radiographically manifested as joint space narrowing. Issue: In the literature, the joint space narrowing progression between a baseline and its follow-up finger joint images can be quantified by using image registration algorithm. We found that the inconsistencies of joint angles may lead to characteristic mismatches and thus severely affect the accuracy of joint space narrowing quantifications. Methods: In this work, we introduce a rotation invariant phase only correlation in joint space narrowing quantification for the joint angle correction. Further, we propose a confidence index to quantify the quantification reliability of phase only correlation based on phase dispersion in phase difference spectrum. Conclusion: In our clinical experiments, the proposed quantification method can effectively overcome and manage the mismatch due to the inconsistency of joint angles. Additionally, the confidence index shows a high consistency with the joint space narrowing progression examinations manually done by a trained radiologist and one radiological technologist. 展开更多
关键词 Rheumatoid Arthritis Joint Space Narrowing Frequency Domain Analysis RADIOLOGY Computer-Aided Diagnosis phase Dispersion
下载PDF
Determination of organochlorine pesticides from juice samples using magnetic biochar-based dispersive micro-solid phase extraction in combination with dispersive liquid-liquid microextraction
12
作者 Kero Assefa Ago Shimeles Addisu Kitte Abera Gure 《Emerging Contaminants》 CSCD 2024年第1期126-138,共13页
Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was deve... Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was developed for the determination of organochlorine pesticides(OCPs)in bottled juice drinks using GC-MS.Sample pretreatment was performed using dispersive solid-phase microextraction(D-μ-SPE)for matrix desorption and dispersive liquid-liquid microextraction(DLLME)for analyte enrichment.In this study,an affordable and effective sorbent for the adsorption of OCPs from juice samples was synthesized from avocado seeds mixed with magnetic precursors for D-μSPE.The ground avocado seeds combined with a magnetic precursor nanocomposite were characterized using various instruments including scanning electron microscopy(SEM),X-ray diffraction(XRD),Fourier transform infrared spectroscopy(FTIR),and Brunauer-Emmett-Teller(BET)analysis.The solution obtained from D-μ-SPE desorption was used as a dispersant for the subsequent DLLME,which made the combination of D-μ-SPE with DLLME much easier.The effectiveness of the method was enhanced by optimizing the influential parameters in both D-μ-SPE and DLLME.Then after,the optimal values were determined for the real sample analysis.Accordingly,there was good linear dynamic range with a coefficient of determination(r2)≥0.9989.The limit of detection and quantification were 0.02–0.69 and 0.06–2.10 ng/L respectively.The method showed high enrichment factors ranging from 96 to 313 with recoveries of 87–100%.Intraday and interday precisions were≤4%.Compared with other reported methods,this method is a one-step,simple,cheap,fast,and environmentally friendly alternative and straightforward method for adsorbing organochlorine pesticides from sample solutions.These results demonstrates the high potential of the proposed method for the extraction and cleanup of contaminants in selected juices and other related samples. 展开更多
关键词 Dispersive micro solid phase extraction Dispersive liquid-liquid microextraction Juice samples Magnetic biochar Organochlorine pesticides Gas chromatography-mass spectrometry
原文传递
Symplectic analysis for elastic wave propagation in two-dimensional cellular structures 被引量:5
13
作者 Xiu-Hui Hou Zi-Chen Deng +1 位作者 Jia-Xi Zhou Tie-Quan Liu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2010年第5期711-720,共10页
On the basis of the finite element analysis, the elastic wave propagation in cellular structures is investigated using the symplectic algorithm. The variation principle is first applied to obtain the dual variables an... On the basis of the finite element analysis, the elastic wave propagation in cellular structures is investigated using the symplectic algorithm. The variation principle is first applied to obtain the dual variables and the wave propagation problem is then transformed into two-dimensional (2D) symplectic eigenvalue problems, where the extended Wittrick-Williams algorithm is used to ensure that no phase propagation eigenvalues are missed during computation. Three typical cellular structures, square, triangle and hexagon, are introduced to illustrate the unique feature of the symplectic algorithm in higher-frequency calculation, which is due to the conserved properties of the structure-preserving symplectic algorithm. On the basis of the dispersion relations and phase constant surface analysis, the band structure is shown to be insensitive to the material type at lower frequencies, however, much more related at higher frequencies. This paper also demonstrates how the boundary conditions adopted in the finite element modeling process and the structures' configurations affect the band structures. The hexagonal cells are demonstrated to be more efficient for sound insulation at higher frequencies, while the triangular cells are preferred at lower frequencies. No complete band gaps are observed for the square cells with fixed-end boundary conditions. The analysis of phase constant surfaces guides the design of 2D cellular structures where waves at certain frequencies do not propagate in specified directions. The findings from the present study will provide invaluable guidelines for the future application of cellular structures in sound insulation. 展开更多
关键词 Cellular structures Symplectic analysis Dispersion relation - phase constant surface Sound insulation
下载PDF
Prediction of mass transfer coefficients in an asymmetric rotating disk contactor using effective diffusivity 被引量:2
14
作者 Meisam Torab-Mostaedi Mehdi Asadollahzadeh Jaber Safdari 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第3期288-293,共6页
Mass transfer characteristics have been investigated in a 113 mm diameter asymmetric rotating disk contactor of the pilot plant scale for two different liquid–liquid systems. The effects of operating parameters inclu... Mass transfer characteristics have been investigated in a 113 mm diameter asymmetric rotating disk contactor of the pilot plant scale for two different liquid–liquid systems. The effects of operating parameters including rotor speed and continuous and dispersed phase velocities on the volumetric overall mass transfer coefficients are investigated. The results show that the mass transfer performance is strongly dependent on agitation rate and interfacial tension, but only slightly dependent on phase flow rates. In this study, effective diffusivity is used instead of molecular diffusivity in the Grober equation for estimation of dispersed phase overall mass transfer coefficient.The enhancement factor is determined experimentally and there from an empirical expression is derived for prediction of the enhancement factor as a function of Reynolds number. The predicted results compared to the experimental data show that the proposed correlation can efficiently predict the overall mass transfer coefficients in asymmetric rotating disk contactors. 展开更多
关键词 Asymmetric rotating disk contactor Mass transfer coefficient Enhancement factor Interfacial area dispersed phase holdup
下载PDF
Tb(III) Transport in Dispersion Supported Liquid Membrane System with D2EHPA as Carrier in Kerosene 被引量:2
15
作者 PEI Liang YAO Bing-hua +1 位作者 WANG Li-ming MA Zhan-ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第1期132-139,共8页
The transport of Tb(III) in dispersion supported liquid membrane(DSLM) with polyvinylidene fluoride membrane(PVDF) as the support and dispersion solution including HCl solution as the stripping solution and di(... The transport of Tb(III) in dispersion supported liquid membrane(DSLM) with polyvinylidene fluoride membrane(PVDF) as the support and dispersion solution including HCl solution as the stripping solution and di(2-ethylhexyl) phosphoric acid(D2EHPA) dissolved in kerosene as the membrane solution, has been studied. The effects of pH value, initial concentration of Tb(III) and different ionic strength in the feed phase, volume ratio of membrane solution to stripping solution, concentration of HCl solution, concentration of carrier, different stripping agents in the dispersion phase on the transport of Tb(III) have also been investigated, respectively. As a result, the optimum transport conditions of Tb(III) were obtained, i.e., the concentration of HCl solution was 4.0 mol/L, the concentration of D2EHPA was 0.16 mol/L, the volume ratio of membrane solution to stripping solution was 30:30 in the dispersion phase and pH value was 4.5 in the feed phase. Ionic strength had no obvious effect on the transport of Tb(III). Under the optimum conditions, the transport percentage of Tb(III) was up to 96.1% in a transport time of 35 min when the initial concentration of Tb(IIl) was 1.0× 10 -4 mol/L. The diffusion coefficient of Tb(III) in the membrane and the thickness of diffusion layer between feed phase and membrane phase were obtained and the values were 1.82×10 -8 m2/s and 5.61 um, respectively. The calculated results were in good agreement with the literature data. 展开更多
关键词 Dispersion supported liquid membrane Di(2-ethylhexyl) phosphoric acid Terbium(III) Dispersion phase Transport flux Transport percentage
下载PDF
Dynamic Mechanical Behavior and Prediction for PP/POE Blends 被引量:1
16
作者 YING Ji-ru XIE Xiao-lin +2 位作者 ZHOU Xing-ping ZHOU Hua-min LI De-qun 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2009年第4期573-578,共6页
Polypropylene(PP)/ethylene-octene copolymer(POE) blends were prepared with a twin-screw extruder.Their dynamic mechanical behavior were systematically investigated.The results show that PP/POE blends are heterogen... Polypropylene(PP)/ethylene-octene copolymer(POE) blends were prepared with a twin-screw extruder.Their dynamic mechanical behavior were systematically investigated.The results show that PP/POE blends are heterogeneities with a partial compatible two-phase structure,the glass transition temperature of PP phases in the blends tends to shift towards high temperature with increasing the POE content,and the glass transition temperature of POE phases shifts towards the low temperature with increasing the PP content.The Kerner's dispersed phase model and co-continuous phase model can reasonably predict the visco-elasticity of PP/POE blends with different compositions.Additionally,the morphological structure of the blends can be estimated via comparing the predicted DMA behavior with the experimental data. 展开更多
关键词 PP/POE blend Dynamic mechanical behavior dispersed phase model Co-continuous phase model
下载PDF
Use of axial dispersion model for determination of Sherwood number and mass transfer coefficients in a perforated rotating disc contactor 被引量:1
17
作者 Mehdi Asadollahzadeh Alireza Hemmati +3 位作者 Meisam Torab-Mostaedi Mansour Shirvani Ahad Ghaemi Zahra Sadat Mohsenzadeh 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第1期53-61,共9页
The mass transfer process in a perforated rotating disk contactor(PRDC) using a toluene-acetone-water system was investigated.The volumetric overall mass transfer coefficients are calculated in a PRDC column.Both mass... The mass transfer process in a perforated rotating disk contactor(PRDC) using a toluene-acetone-water system was investigated.The volumetric overall mass transfer coefficients are calculated in a PRDC column.Both mass transfer directions are considered in experiments.The influences of operating variables containing agitation rate,dispersed and continuous phase flow rates and mass transfer in the extraction column are studied.According to obtained results,mass transfer is significantly dependent on agitation rate,while the dispersed and continuous phase flow rates have a minor effect on mass transfer in the extraction column.Furthermore,a novel empirical correlation is developed for prediction of overall continuous phase Sherwood number based on dispersed phase holdup,Reynolds number and mass transfer direction.There has been great agreement between experimental data and predicted values using a proposed correlation for all operating conditions. 展开更多
关键词 Perforated rotating disk contactor Mass transfer coefficient dispersed phase holdup Interfacial area
下载PDF
Accurate and sensitive determination of hydroxychloroquine sulfate used on COVID-19 patients in human urine,serum and saliva samples by GC-MS
18
作者 Süleyman Bodur Sezin Erarpat +1 位作者 Omer Tahir Günkara Sezgin Bakırdere 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第3期278-283,共6页
A rapid,accurate,and sensitive analytical method,ultrasonication-assisted spraying based fine droplet formationeliquid phase microextractionegas chromatographyemass spectrometry(UA-SFDF-LPME-GCMS),was proposed for the... A rapid,accurate,and sensitive analytical method,ultrasonication-assisted spraying based fine droplet formationeliquid phase microextractionegas chromatographyemass spectrometry(UA-SFDF-LPME-GCMS),was proposed for the determination of trace amounts of hydroxychloroquine sulfate in human serum,urine,and saliva samples.To determine the best extraction strategy,several liquid and solid phase extraction methods were investigated for their efficiencies in isolation and preconcentration of hydroxychloroquine sulfate from biological matrices.The UA-SFDF-LPME method was determined to be the best extraction method as it was operationally simple and provided accurate results.Variables such as the extraction solvent,spraying number,sodium hydroxide concentration and volume,sample volume,mixing method,and mixing period were optimized for the proposed method using the onevariable-at-a-time approach.In addition,Tukey’s method based on a post hoc comparison test was employed to evaluate the significant difference between the parameters inspected.After the optimization studies,the limit of detection(LOD)and limit of quantification(LOQ)were determined to be 0.7 and 2.4 mg/kg,respectively.The sensitivity of the GC-MS system based on the LOD was enhanced approximately 440-fold when the UA-SFDF-LPME method was employed.Spiking experiments were also conducted for the human serum,urine,and saliva samples to determine the applicability and accuracy of the proposed method.Recoveries for the human serum,urine,and saliva samples were found to be in the ranges of 93.9%-101.7%,95.2%-105.0%,and 93.1%-102.3%,respectively.These results were satisfactory and indicated that the hydroxychloroquine sulfate level in the above biological samples could be analyzed using the proposed method. 展开更多
关键词 Hydroxychloroquine sulfate GC-MS Biological samples Dispersive solid phase extraction Liquid phase microextraction
下载PDF
Synthesis of a Novel Imidazole Ionic Liquid Modified Mesoporous Silica SBA15 for Selective Separation and Determination of Inorganic Arsenic in Rice
19
作者 CHEN Tuan-Wei ZHEN Wen-Bo +3 位作者 YAN Zhi-Ming LIN He-Tong CHEN Guo-Ying CHEN Shao-Jun 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2018年第12期2024-2035,1848,共13页
A novel 1-methylimidazole ionic liquid modified SBA15 mesoporous silica(1-MIIL@SBA15) was synthesized and applied to selective separation of inorganic arsenic(iAs) in rice by dispersive solid phase extraction(DSPE), f... A novel 1-methylimidazole ionic liquid modified SBA15 mesoporous silica(1-MIIL@SBA15) was synthesized and applied to selective separation of inorganic arsenic(iAs) in rice by dispersive solid phase extraction(DSPE), followed by hydride generation-atomic fluorescence spectrometric(HG-AFS) quantification. The prepared sorbent was characterized by FTIR, FESEM, BET and Zeta potential. Key parameters of adsorption and desorption in DSPE were optimized using standard reference material 1568 b rice flour. Under optimal conditions, the limit of detection was 8.776 ng/kg, relative standard deviation was ≤2.0%, and recoveries of iAs were in the 92.3~94.4% range. This method was successfully applied to the determination of iAs in rice. Under acidic condition, the electrostatic interaction between the positively charged 1-MIIL@SBA15 and anionic iAs played an important role in selective iAs separation, rendering this method suitable for iAs analysis. 展开更多
关键词 SBA15 ionic liquid inorganic arsenic dispersive solid phase extraction hydride generation-atomic fluorescence spectrometric(HG-AFS)
下载PDF
Trace determination of hexabromocyclododecane diastereomers in water samples with temperature controlled ionic liquid dispersive liquid phase microextraction 被引量:3
20
作者 Ru Song Zhao Xia Wang Jin Peng Yuan Shan Shan Wang Chuan Ge Cheng 《Chinese Chemical Letters》 SCIE CAS CSCD 2011年第1期97-100,共4页
A novel temperature controlled ionic liquid dispersive liquid phase microextracfion (TCIL-DLPME) coupled with rapid resolution liquid chromatography-electrospray tandem mass spectrometry (RRLC-ESI-MS-MS) has been ... A novel temperature controlled ionic liquid dispersive liquid phase microextracfion (TCIL-DLPME) coupled with rapid resolution liquid chromatography-electrospray tandem mass spectrometry (RRLC-ESI-MS-MS) has been developed for the enrichment and determination of three hexabromocyclododecane diastereomers (HBCDs) in water samples. Green solvent ionic liquid (IL) was used as extraction solvent instead of toxic organic solvents. This technique also avoided the usage of dispersive solvent. Some important parameters that might affect the extraction efficiency were optimized. Under the optimum conditions, good linear relationship, sensitivity and reproducibility were obtained. All the limits of detection for the three diastereomers were 0.1 ng/ mL. The linear range was obtained in the range of 1-100 ng/mL for the total amount of three HBCD diastereomers. It was satisfactory to analyze real environmental water samples with the recoveries ranging from 77.2% to 99.3%. The main advantage of the method is toxic organic solvent-free. 展开更多
关键词 HEXABROMOCYCLODODECANE Temperature controlled ionic liquid dispersive liquid phase microextraction Rapid resolution liquidchromatography-electrospray tandem mass spectrometry
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部