In this paper, after taking th e effect of axis force on bending into consideration, the general potential ener gy for the circular double articulated arch is established undergoing vertical d istributive load g 0/...In this paper, after taking th e effect of axis force on bending into consideration, the general potential ener gy for the circular double articulated arch is established undergoing vertical d istributive load g 0/ cos 2θ . With sufficient engineering precision, the fourth approximations to the destabilizing critical load of the arch under t his load are obtained by Ritz method. The approximations to the critical load ta ble are listed for various center angles of arch, and are contrasted with the cr itical load circular arch undergoing radial uniform load. Some reference results have been obtained.展开更多
Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults...Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults.Because of the weak fault current and imperfect monitoring equipment configurations,methods used to determine the faulty line secti ons with SPG faults in NIGSs are in effective.The developme nt and application of distributi on-level phasor measurement units(PMUs)provide further comprehensive fault information for fault diagnosis in a distribution network.When an SPG fault occurs,the transient energy of the faulted line section tends to be higher than the sum of the transient energies of other line sections.In this regard,transient energy-based fault location algorithms appear to be a promising resolution.In this study,a field test plan was designed and implemented for a 10 kV distribution network.The test results dem on strate the effective ness of the transient en ergy-based SPG locati on method in practical distributi on networks.展开更多
文摘In this paper, after taking th e effect of axis force on bending into consideration, the general potential ener gy for the circular double articulated arch is established undergoing vertical d istributive load g 0/ cos 2θ . With sufficient engineering precision, the fourth approximations to the destabilizing critical load of the arch under t his load are obtained by Ritz method. The approximations to the critical load ta ble are listed for various center angles of arch, and are contrasted with the cr itical load circular arch undergoing radial uniform load. Some reference results have been obtained.
基金National Key R&D Program of China(2017YFB0902800)Science and Technology Project of State Grid Corporation of China(52094017003D)supported this work.
文摘Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults.Because of the weak fault current and imperfect monitoring equipment configurations,methods used to determine the faulty line secti ons with SPG faults in NIGSs are in effective.The developme nt and application of distributi on-level phasor measurement units(PMUs)provide further comprehensive fault information for fault diagnosis in a distribution network.When an SPG fault occurs,the transient energy of the faulted line section tends to be higher than the sum of the transient energies of other line sections.In this regard,transient energy-based fault location algorithms appear to be a promising resolution.In this study,a field test plan was designed and implemented for a 10 kV distribution network.The test results dem on strate the effective ness of the transient en ergy-based SPG locati on method in practical distributi on networks.