期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Application of Wavelet Transform in Dual-differential Optical Fiber F-P Interferometric Micro-displacement Measurement System
1
作者 ZHANG Shu-qing YANG Feng-lu WANG Xue-qiang BAI Qin-yuan ZHANG Li-guo 《Semiconductor Photonics and Technology》 CAS 2005年第4期263-265,共3页
Based on dual-differential comparing principle, an experimental system of optical fiber F-P interferometric micro-displacement measurement is introduced. It is capable of achieving the absolute displacement measuremen... Based on dual-differential comparing principle, an experimental system of optical fiber F-P interferometric micro-displacement measurement is introduced. It is capable of achieving the absolute displacement measurement, and wavelet transforms is adopted as theory fundament to extract the optical F-P interferometric characteristic signal and remove the noise, so its resolution can reach 0. 01 μm in the dynamic range of 0~ 1 mm. 展开更多
关键词 Optical fiber Fabry-Perot interferometer MICRO-DISPLACEMENT dual differential Wavelet transform
下载PDF
A Dual Wavelength Differential First Derivative Spectrophotometric Method for Identification and Determination of Carbon Monoxide Generated During the Microsomal Metabolism of Xenobiotics in vitro
2
作者 徐宏祥 刘志强 《Journal of Chinese Pharmaceutical Sciences》 CAS 1997年第2期51-56,共6页
A dual wavelength differential first derivative spectrophotometric method has been developed to standardize the concentration of a saturated aqueous solution of carbon monoxide (CO) as the standard and to identify and... A dual wavelength differential first derivative spectrophotometric method has been developed to standardize the concentration of a saturated aqueous solution of carbon monoxide (CO) as the standard and to identify and to determine CO formed during the microsomal metabolism of xenobiotics in vitro. The method can significantly eliminate the background interference in the assay media and increase the quantitative accuracy and the sensitivity. There is a good linear relationship between CO concentration in the range of 2~10 μmol·L 1 CO and the distance D between the first derivative peak at 415 nm amd valley at 426 nm with r=0.9999(n=5),the regression equation being C (mmol·L 1 )=17.6D 0.4, the detection limit lower than 0.1 μmol·L 1 CO. The average recoveries of CO from the assay system and the sample were 102.1%, RSD=2.9% (n=7) and 79.7%, RSD=6.8% (n=12),respectively. The RSD of within day was 4.4%(n=18),and the RSD of day to day was 6.1%(n=16). By this method, four trihaloanilines and one trihalobenzene were tested, the results showed that only 2,4,5 trifluoroaniline could be converted to CO by the incubation with rat hepatic microsomes, NADPH and oxygen, the ability of phenobarbital or dexamethasone to induce rat hepatic microsomes to catalyze CO formation was 3 or 8 times higher than that of the control. 展开更多
关键词 dual wavelength differential first derivative spectrophotometry Carbon monoxide Trifluoroaniline Drug metabolism Hepatic microsomes Cytochrome P 450
全文增补中
上一页 1 下一页 到第
使用帮助 返回顶部