期刊文献+
共找到15,954篇文章
< 1 2 250 >
每页显示 20 50 100
Value of Acceleration Flow in the Left Anterior Descending Coronary Artery for the Detection of Coronary Artery Stenosis by Transthoracic Coronary Color Doppler Echocardiography
1
作者 陈斌 邓又斌 +4 位作者 杨好意 阮燕菲 常青 毕小军 王红英 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第5期597-600,共4页
Whether the localized flow acceleration occurs in the resting stenotic left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left anterior ... Whether the localized flow acceleration occurs in the resting stenotic left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoracic color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow. There were 23 patients with localized acceleration flow examined by echocardiography. Twenty of them were found to have luminal diameter stenosis (60 %-98 %) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by echocardiography. Eighteen of them had no or <60 % stenosis. Four patients had serious stenosis (≥95 %) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P<0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r= 0.77, P<0.01). The specificity by using the ratio≥1.5 for stenosis detection was 85.7 % (18/21), and the sensitivity was 83.3 % (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotic left anterior descending coronary artery. Transthoracic color Doppler echocardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending coronary artery. 展开更多
关键词 血流速度 冠状动脉 血管狭窄 经胸廓检查 多普勒超声波心动描记术
下载PDF
Investigation of lacrimal sac space-occupying lesions using color doppler ultrasound, computed tomography, and computed tomography dacryocystography
2
作者 Zhen-Bin Qian Bo Yu +3 位作者 Ye Yang Wei Fang Jian-Li Dong Li-Qing Wei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1224-1230,共7页
AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:T... AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022.The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system.The images were observed and analyzed.RESULTS:The detection rate of lacrimal SOLs between CDU(21/21,100%)and CT or CT-DCG(20/21,95.2%)had no statistically significant difference(P=1.0).CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion.Among them,polyps had characteristic imaging changes on CDU and CT-DCG.The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU,which could provide more information for differential diagnosis.CONCLUSION:The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU.CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass.Therefore,CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG. 展开更多
关键词 lacrimal sac computed tomography computed tomography dacryocystography color doppler ultrasound space-occupying lesions
原文传递
The Study of Ovarian Artery Hemodynamics in Patients with Infertility by Color Doppler Energy 被引量:2
3
作者 肖先桃 乐桂蓉 +1 位作者 张友耿 黎春蕾 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2001年第1期42-43,共2页
Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI)... Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI). All the patients were verified by laparoscopy, fallopian tube patency examination and ovarian function test. Twenty two healthy women served as controls. The results showed that the difference of resistance index(RI)and pulsatility index (PI) of bilateral ovarian arteries between the infertility and the normal controls had statistical significance ( P <0.01), and the PI showed negative correlation with the thickness of endometrium (left side: r =0.724, P <0.01; right side: r =0.756, P <0.01). The results also showed that CDE was more sensitive than CDFI in displaying the ovarian arteries. It could be concluded that the elevated resistance of ovarian artery during the corpus luteum phase was one of the important factors that resulted in infertility. 展开更多
关键词 ovarian artery color doppler flow imaging color doppler energy resistance index pulsatility index INFERTILITY
下载PDF
The value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications 被引量:7
4
作者 Dao-Zhong Huang Gui-Rong Le +4 位作者 Qing-Ping Zhang Kai-Yan Li Qi-Fa Ye Wei Zhu Yun-Chao Chen the Department of Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2003年第1期54-58,共5页
OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic livertransplantation and postoperative complications.METHODS: Forty-one patients after orthotopic liver transplantation w... OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic livertransplantation and postoperative complications.METHODS: Forty-one patients after orthotopic liver transplantation were examined by using colorDoppler flow imaging to observe the hepatic blood flow and change of ultrasonography of the hepaticparenchyma and bile duct. The measured indexes included maximum blood flow velocity, time-averageblood flow velocity (TAV), resistance index (RI) and diameter of the bile duct.RESULTS: Among 41 patients, 17 (41.5%) suffered from liver transplant rejection. Of the 17patients, 13 (76.4%) showed decrease of TAV of the portal vein, 15 (88.25%) low-amplitudesingle-phase serrated wave or negative biphasic wave of the hepatic vein, 9 (52.9%) increased hepaticarterial RI, and 5 (29.4%) slightly dilated bile duct. Sonography showed disappearance of the hepaticartery blood flow around the portal vein in 5 (12.2%) of the 41 patients with hepatic artery thrombosisin the postoperative period. Slight dilatation of the intrahepatic bile duct was found in 3 (7.3%) of the41 patients in the early postoperational period and it normalized within 2 weeks. Ultrasonography of20 patients (48.8%) revealed a visible dilatation of the intrahepatic bile duct, which was worseninggradually. The causes of bile duct dilatation included biliary stricture in 2 patients (10%), stone in 15patients (75%) and others in 3 patients (15%).CONCLUSIONS: Color Doppler ultrasonography is valuable for monitoring normal liver transplantationand postoperative complications. 展开更多
关键词 ULTRASONOGRAPHY doppler color liver TRANSPLANTATION COMPLICATION
下载PDF
Measurements Of Cerebral Blood Flow in Postasphyxiated Newborns by Color Doppler Imaging(CDI) 被引量:7
5
作者 常立文 汪元芳 刘婉君 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1996年第4期249-252,共4页
MeasurementsOfCerebralBloodFlowinPostasphyxiatedNewbornsbyColorDopplerImaging(CDI)CHANGLiwen(常立文);WANGYuanfa... MeasurementsOfCerebralBloodFlowinPostasphyxiatedNewbornsbyColorDopplerImaging(CDI)CHANGLiwen(常立文);WANGYuanfang(汪元芳);LIUWanjun... 展开更多
关键词 asphyxiated NEWBORNS CEREBRAL BLOOD FLOW ultrasound imaging color doppler
下载PDF
Color Doppler ultrasonographic examination on the relationship between the gallbladder bed and major branch of the middle hepatic vein 被引量:3
6
作者 Wei-Zhong Zhang, Jie Shen, Jue-Xing Xie and Hong Zhu Taizhou, China Departments of Surgery and Ultrasonography , Taizhou First People’s Hospital, Taizhou 318020, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2005年第2期299-301,共3页
BACKGROUND: There is a controversy about the risk of injury to the branch of the middle hepatic vein during lapa- roscopic cholecystectomy. This study was conducted to further investigate the relationship between the ... BACKGROUND: There is a controversy about the risk of injury to the branch of the middle hepatic vein during lapa- roscopic cholecystectomy. This study was conducted to further investigate the relationship between the gallbladder bed and the branch of the middle hepatic vein. METHODS: Color Doppler ultrasound was used to exa- mine the anatomical relationship between the gallbladder bed and the branches of the middle hepatic vein in 143 healthy volunteers. RESULTS: Not all the middle hepatic vein extended close to the gallbladder bed, the branches and gallbladder beds in 23 subjects were not in the same plane during ultrasound scanning. In 21 of the 143 subjects the branch of the middle hepatic vein was completely adherent to the gallbladder bed with a diameter ranging from 1.2 mm to 3.6 mm. In 10 subjects the branches of the middle hepatic vein traversed approximately 1.0 mm from the gallbladder bed with a dia- meter ranging from 1.6 mm to 3.0 mm. CONCLUSIONS: In most subjects the branch of the middle hepatic vein and the gallbladder bed are well separated. Only patients with large branches of the middle hepatic vein close to the gallbladder bed are at risk of hemorrhage during laparoscopic cholecystectomy. 展开更多
关键词 LAPAROSCOPIC CHOLECYSTECTOMY color doppler ultrasound HEPATIC VEIN
下载PDF
Evaluation of diagnosis and curative criterion for concussion patients by color three-dimensional trascrani doppler 被引量:1
7
作者 肖兴义 薛贯生 +2 位作者 李春玲 郭新红 宋燕 《中国组织工程研究》 CAS CSCD 2001年第7期154-155,共2页
Objective In order to offer a noninvasive and objective examination method for assessing the clinical diagnosis and eurative criterion of concussion patients,the patients color three-dimensional transcranial doppler... Objective In order to offer a noninvasive and objective examination method for assessing the clinical diagnosis and eurative criterion of concussion patients,the patients color three-dimensional transcranial doppler(3D-TCD)characteristic at deferent phases,parameter and clincal manifestation were studied.Method Parameter of Median Cerebral Artery(MCA),Base Artery(BA),the average peak forwand velocity of cerebral blood flow,train figure were tested by 3D-TCD within 24 hours,3-6 days and at the end of treatment,respectively.The results were compared with clinical diagnoses and curative criterion.Result Among 135 patients who had clinically diagnosed concussion,agreeable diagnoses 101 cases,basically agreeable diagnoses 12 cases,disagreeable diagnosis 22 cases(16.2%).At the end of treatment, according to clinical determination 96 cases(71.1%)were cured,39 cases(28.9%)were improved.Wave train character,figure and diagnoses parameter of cerebral spasm caused by concussion were suggested.Conclusion To be one of the diagnostic bases and curative criterion,3D-TCD technology is performable.Meanwhile,it is a new testing objective technique for assessing curative and determining prognosis. 展开更多
关键词 cerebral CONCUSSION color three-dimensioal TRANSCRANIAL doppler diagnostic basis CURATIVE CRITERION
下载PDF
Paper Clinical Value of Color Doppler Ultrasonography in Diagnosis of Lower Extremity Arterial Disease of Diabetes Patients 被引量:2
8
作者 Jianyu Zhang Haijiao Mao 《Journal of Biosciences and Medicines》 2020年第6期209-214,共6页
<div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. &l... <div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. <strong>Methods: </strong>48 patients with diabetic lower extremity vascular disease admitted in our hos-pital from September 2018 to September 2019 were included in the study and divided into the observation group, and another 48 patients with the same period of health examination in our hospital were included in the study and divided into the control group. Both groups used color Doppler ultrasound to detect the blood flow of lower extremity vessels. The incidence of blood flow, vascular diameter and stenosis, occlusion and arteriosclerosis of the lower extremity were observed. <strong>Results:</strong> The blood flow and vascular di-ameter of the lower extremity in the observation group were significantly lower than those in the control group (p < 0.05). The incidence of vascular stenosis, vascular occlusion, thrombus, intimal thickening and plaque in the observation group was 85.42%, 22.92%, 10.42% and 93.75% respectively, which was significantly higher than that in the control group was 10.42%, 0.00%, 0.00% and 14.58% (p < 0.05). The incidence of lower extremity vascular lesions in the observation group was significantly higher than that in the control group (p < 0.05). <strong>Conclusion:</strong> Color Doppler ultrasound is of high diagnostic value in the diagnosis of diabetic lower extremity vascular diseases, and can be used to determine the blood flow of the lower extremity and the inner diameter of popliteal artery, thigh artery, dorsalis pedis artery and so on. At the same time, it can also clearly show the specific situation of vascular occlusion, arteriosclerosis and thrombosis, which is of great signif-icance for the prevention and diagnosis of lower extremity vascular lesions, and can provide the basis for the treatment of lower extremity vascular lesions. </div> 展开更多
关键词 Super color doppler Ultrasound Diabetic Complications Lower Extremity Vascular Disease Diagnostic Value
下载PDF
The Diagnostic Value of Color Doppler Ultrasound and Grey Scale Sonography in Predicting the Malignancy of Thyroid Nodules 被引量:2
9
作者 Hamad Elniel H. Eltyib Sameh A. Aborizk +2 位作者 Hanan A. Albalawi Afaf S. Almotairi Arwa H. Aidrus 《Open Journal of Radiology》 2020年第4期215-222,共8页
Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. ... Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. Out of 120 patients, 106 (88.3%) female and 14 (11.7%) male patients. Out of 106 female patients, 64 (91.45) had benign and 42 had malignant thyroid nodules. Out of 14 (11.7) male patients, 6 had benign and 8 had malignant thyroid nodules. The youngest patient in our study was 31 years and the oldest patient was 76 years. The common range of patients age was ≥ 60 years and consisting of twenty (28.6%) benign thyroid nodules and fourteen (28%) malignant thyroid nodules. The majority of patients’ age group with malignant thyroid nodules were between 50 - 60 years and consisting of twenty (40%) malignant nodules. In our study, according to the result of gray scale and color Doppler ultrasonography, hypo-echogenicity, solid echo structure, micro-calcification and intra-nodular vascularity were the significant characteristics of malignancy in nodules with sensitivity (72%, 74%, 48% and 88% respectively), specificity (66%, 63%, 94% and 69% respectively), PPV (60%, 59%, 86% and 67% respectively) and NPV (77%, 77%, 72% and 89% respectively). 展开更多
关键词 ULTRASOUND Thyroid Nodules MALIGNANT color doppler Fine Needle Aspiration
下载PDF
Correlation Study of Color Doppler Examination of Deep Veins of Both Lower Extremities Combined with Fibrinolysis System in Hypertension during Pregnancy 被引量:2
10
作者 Chundong Qiu Haiyan Chen +3 位作者 Xiaohua Huang Xiaoling Kong Chong Liang Chunhong Qiu 《Open Journal of Obstetrics and Gynecology》 2020年第8期981-989,共9页
<strong>Objective</strong><span style="font-family:Verdana;"><strong>:</strong></span><span style="font-family:Verdana;"> To investigate the correlation be... <strong>Objective</strong><span style="font-family:Verdana;"><strong>:</strong></span><span style="font-family:Verdana;"> To investigate the correlation between deep static color Doppler ultrasound of both lower extremities combined with fibrinolytic system detection in pregnancy-induced hypertension.</span><span style="font-family:""> </span><b><span style="font-family:Verdana;">Methods</span></b><b><span style="font-family:Verdana;">:</span></b><span style="font-family:Verdana;"> A total of 70 normal pregnant women, 70 pregnant women with hypertension during pregnancy, and 50 healthy non-pregnant women in the same period were selected as the research objects. The deep veins of both lower limbs were examined by Rili Erlangshen’s color Doppler ultrasound diagnostic instrument (CDU),</span><span style="font-family:""> </span><span style="font-family:""><span style="font-family:Verdana;">and the </span><span style="font-family:Verdana;">fibrinolysis system was tested by enzyme-linked immunosorbent assay (ELISA) </span><span style="font-family:Verdana;">method and </span><a name="OLE_LINK12"></a><span style="font-family:Verdana;">automatic hemagglutination analyzer.</span><b><span style="font-family:Verdana;"> Results</span></b></span><b><span style="font-family:Verdana;">:</span></b><b><span style="font-family:""> </span></b><span style="font-family:Verdana;">Compared with the non-pregnant group, the inner diameters of the left/right femoral vein (CFV) and popliteal vein (POV) in the normal pregnancy group and the pregnancy-induced hypertension group were significantly widened, and the peak blood flow spectrum was significantly reduced. The difference was statistically significant (P < 0.01);FIB, PLG, t-PA, PAI, D-Dimer were significantly increased, the difference was statistically significant (P < 0.01);Compared with the normal pregnancy group, the inner diameter of the left/right femoral vein (CFV) in the hypertensive pregnancy group was significantly wider than that in the normal pregnancy group, and the peak value of the left/right POV blood flow spectrum was significantly lower than that in the normal pregnancy group,</span><span style="font-family:""> </span><span style="font-family:Verdana;">the difference w</span><span style="font-family:Verdana;">as</span><span style="font-family:Verdana;"> statistically significant (P < 0.01)</span><span style="font-family:Verdana;">,</span><span style="font-family:""> <span style="font-family:Verdana;">while the left/right popliteal vein (POV) inner diameter, left/right CFV blood flow peak value did not change significantly from the normal pregnancy</span><span style="font-family:Verdana;"> grou</span></span><span style="font-family:Verdana;">p, </span><span style="font-family:Verdana;">and the difference was not statistically significant (P > 0.05);FIB, PLG, PAI, D-Dimer of the hypertensive disease group during pregnancy significantly increased, the difference was statistically significant (P < 0.01), while t-PA was not statistically significant (P > 0.05).</span><span style="font-family:""> </span><b><span style="font-family:Verdana;">Conclusion</span></b><b><span style="font-family:Verdana;">:</span></b><b><span style="font-family:""> </span></b><span style="font-family:Verdana;">Normal pregnant women have a hypercoagulable state compared with healthy non-pregnant women, and pregnant women with hypertension during pregnancy are more likely to be in a pre-thrombotic state than pregnant women with normal pregnancy. Deep vein CDU examination of both lower extremities combined with blood fibrinolysis monitoring is of great value in the prevention and treatment of hypertension during pregnancy.</span> 展开更多
关键词 Hypertension during Pregnancy Prothrombotic State color doppler Ultrasound Fibrinolysis Index
下载PDF
The Role of Color Doppler Ultrasound Arterial Mapping for Decision Making in the Treatment of Patients with Lower Extremity Peripheral Arterial Disease 被引量:1
11
作者 Ali Babaei Jandaghi Zahra Mardanshahi +5 位作者 Ahmad Alizadeh Iraj Baghi Hossein Hemmati Narges Tabarzan Baboli Shabnam Alizadeh Arasi Amin Keshavarzzirak 《Surgical Science》 2013年第10期415-420,共6页
Purpose: To assess the efficacy of color Doppler imaging for decision making in the treatment of patients with lower extremity peripheral arterial disease (PAD) compared to digital subtraction angiography (DSA). Mater... Purpose: To assess the efficacy of color Doppler imaging for decision making in the treatment of patients with lower extremity peripheral arterial disease (PAD) compared to digital subtraction angiography (DSA). Materials and Methods: Color Doppler scan was done on patients suspected for lower limb PAD, a day prior to the DSA which was done by a vascular surgeon. Also, for the patients who were candidates for endovascular intervention based on the color Doppler arterial mapping results, endovascular interventions were performed at the same time if the DSA findings are correlated with the color Doppler map. The grading for evaluated segments was normal, insignificant stenosis (<50%), hemodynamically significant stenosis (≥50%) and occlusion. We yielded the diagnostic efficacy indices of Doppler for detecting arterial stenosis in each 18 different arterial segments below the renal arteries including, infrarenal aorta, common and external iliac, common femoral, superficial femoral (proximal, middle and distal segments), deep femoral, popliteal artery, tibioperoneal trunk, anterior and posterior tibial arteries (proximal, middle and distal segments) and peroneal artery (proximal and distal segments). Then, we yielded the kappa agreement between Doppler and DSA findings considering the grade of stenosis in 18 arterial segments separately. Results: Totally 115 lower extremities (2045 arterial segments) were evaluated in 90 patients [mean age: 60.8 ± 8.9 (range: 47 - 84 years old)] of which 68 (75.6%) were men. The sensitivity of color Doppler for all arterial segments was 90% or higher except for common iliac artery, distal segment of superficial femoral artery and proximal segments of anterior and posterior tibialis and peroneal arteries. However, the specificity was 89% or higher, in all arterial segments. Kappa agreement was 0.72 or higher in all segments (All P-Values 0.001). Conclusion: This study suggests that considering excellent capability of color Doppler sonography in the evaluation of lower extremity arterial disease, color Doppler arterial mapping is sufficient for decision making in the treatment of these patients and can reduce the rate of diagnostic angiography. 展开更多
关键词 Lower EXTREMITY Peripheral ARTERIAL Disease color doppler SONOGRAPHY ARTERIAL MAPPING Digital SUBTRACTION ANGIOGRAPHY
下载PDF
Color Doppler Imaging in the Diagnosis and Follow-up of Carotid Cavernous Sinus Fistulas 被引量:1
12
作者 Zhongyao Wu Huasheng Yang Zhongshan Ophthalmic Center,Sun Yat-Sen University of Medical Sciences Guangzhou 510060,China 《眼科学报》 1993年第3期153-157,共5页
This report describes color doppler imaging (CDI) in theevaluation and follow-up of nine patients with carotid cavernous sinusfistulas.The orbits and carotid arteries were examined with CDI.In allcases,the diagnosis w... This report describes color doppler imaging (CDI) in theevaluation and follow-up of nine patients with carotid cavernous sinusfistulas.The orbits and carotid arteries were examined with CDI.In allcases,the diagnosis was confirmed by angiography.CDI clearlydemonstrated the dilated superior ophthalmic veins (SOVs) with retrogradeflow and low resistance arterial doppler waveform in all nine patients (10eyes).After the study of quantitative hemodynamics,we found that directcarotid cavernous sinus fistulas s... 展开更多
关键词 color doppler imaging carotid cavernous sinus fistulas angiography orbit DIAGNOSE
下载PDF
Early warning study of color doppler ultrasound in children with thyroid nodules and thyroid cancer 被引量:1
13
作者 Li Yang Wen-Qi Ma +1 位作者 Bai-Ling Liu Qi Zhou 《Journal of Hainan Medical University》 2019年第9期66-69,共4页
Objective: To study the diagnostic value of color doppler ultrasound in children with thyroid nodules and thyroid cancer. Methods: A total of sixty children with thyroid nodules treated in our hospital from March 2017... Objective: To study the diagnostic value of color doppler ultrasound in children with thyroid nodules and thyroid cancer. Methods: A total of sixty children with thyroid nodules treated in our hospital from March 2017 to March 2018 were selected for study. All patients underwent color Doppler ultrasound diagnosis. According to the diagnostic data, benign thyroid nodules and thyroid cancer were analyzed. The nodule nature was grouped into benign nodules group and malignant nodules group. The aspect ratio and boundary of the two groups were compared in blurring, calcification, blood flow signal classification, etc. Results: A total of 95 nodules were diagnosed by color doppler ultrasonography in 60 cases of thyroid nodules. 49 cases were benign nodules. There were 80 nodules, accounting for 82.11%, 11 cases of thyroid cancer, and 15 nodules. Accounted for 15.79%. Biopsy puncture pathology confirmed 77 benign nodules and 18 malignant nodules. The pathological results were gold standard. The specificity of color Doppler ultrasound was 90%, the sensitivity was 66.67%, and the accuracy of ultrasound diagnosis was 86.32%.The two nodules were statistically significant in terms of boundary, aspect ratio, calcification, echo, and resistance index (P<0.05), but the end-diastolic blood flow velocity (EDV) and peak systolic blood flow velocity ( There was no statistical difference between the PSV levels (P>0.05).Conclusion: Color Doppler ultrasound has the advantages of simple operation, high accuracy, non-invasive and painless, and reproducible detection. The high-frequency probe can clearly display changes such as minute lesions, blood flow signals, echoes, calcifications, etc., and can diagnose thyroid cancer in time. It provides a favorable basis for clinical treatment and has important clinical warning value, especially for children with thyroid examination. 展开更多
关键词 THYROID NODULES color doppler ULTRASOUND PEDIATRIC THYROID cancer Early WARNING
下载PDF
Non-invasive Assessment of Coronary Flow Velocity Reserve: A New Method Using Transthoracic Doppler Echocardiography
14
作者 杨娅 王新房 +5 位作者 Thomas Bartel Holger Eggebrecht Loredana Latina Clemems von Birgelen Guido Caspari Raimund Erbel 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2002年第2期158-163,共6页
Summary: Transthoracic Doppler echocardiography (TTDE) allows noninvasive flow measurement in the distal left anterior descending artery (LAD). The feasibility of detecting coronary flow by contrast-enhanced TTDE with... Summary: Transthoracic Doppler echocardiography (TTDE) allows noninvasive flow measurement in the distal left anterior descending artery (LAD). The feasibility of detecting coronary flow by contrast-enhanced TTDE with second harmonic technique was assessed, the coronary flow velocity reserve (CFVR) was evaluated in comparison to intracoronary Doppler flow (ICD) analysis and the CFVR after PTCA in LAD was investigated. In 77 (96 %) of 80 patients, CFVR was successfully determined with intravenous adenosine infusion. Doppler signal quality was evaluated in the first 46 patients by use of intravenous Levovist infusion and second harmonic technique. The Doppler flow was not visible in 1 patient only. CFVR determined from TTDE (2.77±0.65) was correlated closely with those from ICD (2.88±0.78) measurements (y=0.73x+0.67, r=0.87, P<0.001). In conclusion, TTDE is a feasible method and provides reliable data on CFVR which can be used for follow-up after PTCA. 展开更多
关键词 CORONARY flow velocity RESERVE doppler echocardiography INTRACORONARY doppler
下载PDF
Application of Color Doppler Ultrasonic Examination in Deep Vein Valvular Incompetence in Lower Limbs
15
作者 吴亚群 薛新波 +2 位作者 覃修福 汪元芳 张青萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1997年第1期49-53,共5页
By use of color Doppler Flow Imaging (CDFI), the morphologic and hemodynamic parameters such as the diameters of femoral and popliteal veins,blood flow velocity and the reflux 0f valve area were examined in lower extr... By use of color Doppler Flow Imaging (CDFI), the morphologic and hemodynamic parameters such as the diameters of femoral and popliteal veins,blood flow velocity and the reflux 0f valve area were examined in lower extremity deep valvular incompetence (DVI) and normal control gr0ups. The purpose was to evaluate the value of CDFI in the diagnosis of DVI. The results demonstrated that the parameters between the two groups had a very significant difference (P<0. 001), indicating that the CDFI is non-invasive, cost-effective and safe and it might serve as a practical tool in the diagnosis of lower extremity deep va1vular incompetence. 展开更多
关键词 color doppler flow imagingl diagnosis LOWER EXTREMITY deep valvular INCOMPETENCE
下载PDF
QUANTITATIVE ANALYSIS ON CHANGES OF HEPATIC HEMODYNAMICS AFTER TRANSCUTANEOUS ELECTRIC PULSE STIMULATION OF LOCAL POINTS BY USING COLOR DOPPLER ULTRASOUND DIAGNOSTIC APPARATUS
16
作者 张均倡 王岭 +2 位作者 李红 李峻 张云 《World Journal of Acupuncture-Moxibustion》 2006年第3期3-7,共5页
Objective: To evaluate the effect of transcutaneous electric pulse stimulation (TEPS) on hepatic blood flow and parenchymal microcirculation in patients with fatty liver. Methods: A total of 31 fatty liver volunteer p... Objective: To evaluate the effect of transcutaneous electric pulse stimulation (TEPS) on hepatic blood flow and parenchymal microcirculation in patients with fatty liver. Methods: A total of 31 fatty liver volunteer patients were observed in this study. Changes of color Doppler energy (CDE) images before and after TEPS of local points nearby the liver were recorded by using color Doppler ultrasound diagnostic apparatus (ACUSON 128XP/10C). Sum of color pixel area (SCPA), average of color value (ACV) and SCPA×ACV (integral) of the hepatic flow images were analyzed by an image processing system, single blind method and paired t-test. Programmed TEPS (0.5- 150 Hz / 2 000 Hz , 10- 25 V ) was applied to the right Qimen (期门 LR 14)-Jingmen (京门 GB 25), Fuai (腹哀 SP 16)-Ganshu (肝俞 BL 18) respectively for 15 min. Results: Compared with basic values of pretreatment, SCPA, ACV and SCPA×ACV increased significantly (t=2.71, P<0.02; t=3.42, P<0.01; and t=8.15, P<0.001) after TEPS, meaning improvement of hepatic blood flow supply. Conclusion: TEPS of acupoints near the liver can improve hepatic blood flow and hepatic parenchymal microcirculation in patients with fatty liver. 展开更多
关键词 FATTY liver TRANSCUTANEOUS electric pulse STIMULATION color doppler energy HEPATIC
下载PDF
Left Coronary Artery Fistula Identified by Color Doppler Flow Imaging
17
作者 杨娅 李治安 +1 位作者 王新房 邓又兵 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1995年第3期176-177,共2页
LeftCoronaryArteryFistulaIdentifiedbyColorDopplerFlowImagingYANGYa(杨娅);LIZhi-an(李治安);WANGXin-fang(王新房);DENGY... LeftCoronaryArteryFistulaIdentifiedbyColorDopplerFlowImagingYANGYa(杨娅);LIZhi-an(李治安);WANGXin-fang(王新房);DENGYou-bin(邓又兵)(Depar... 展开更多
关键词 CORONARY ARTERY FISTULA color doppler FLOW imaging
下载PDF
TRANSVAGINAL COLOR DOPPLER STUDY OF UTEROPLACENTAL CIRCULATION IN NORMAL EARLY PREGNANCY
18
作者 Mu Junwu,Yin Yimin,Lei XiaoyingDepartment of Ultrasound, Second Affiliated Hospital, Xi′an Medical University,Xi Meiying  Department of Ultrasound, First Affiliated Hospital, Xi′an Medical University, Xi′an 710061 《Journal of Pharmaceutical Analysis》 CAS 1999年第2期170-175,共6页
A cross sectional transvaginal color Doppler study of the uteroplacental circulation was performed on 105 pregnant women with normal intrauterine pregnancy. Gestational age was ranged from 4 to 12 weeks. The blood flo... A cross sectional transvaginal color Doppler study of the uteroplacental circulation was performed on 105 pregnant women with normal intrauterine pregnancy. Gestational age was ranged from 4 to 12 weeks. The blood flow velocity waveforms were obtained from four separate parts of the uteroplacental circulation: uterine, arcuate, radial, and spiral arteries. The resistance index (RI) and peak systolic velocity (PSV) were analyzed. The RI significantly decreased and PSV increased with advancing gestation in uterine artery and its branches (P<0 05). The RI gradully decreased from uterine artery through arcuate, radial to spiral arteries (P<0 05). At the same time, the PSV decreased from uterine artery then arcuate to radial artery, but PSV in spiral arteries were higher than that in radial artery (P<0 05). The results showed that transvaginal color Dopper ultrasonography was a simple, reliable method to assess the uteroplacental circulation in the early pregnancy; the detection of PSV was useful parameter for better understanding of physiological and pathophysiological hemodynamic changes as well as RI. 展开更多
关键词 TRANSVAGINAL color doppler uteroplacental CIRCULATION early PREGNANCY BLOOD flow
下载PDF
THE CLINICAL VALUE OF COLOR DOPPLER FLOW CONVERGENCE IN THE QUANTIFICATION OF MITRAL REGURGITATION
19
作者 戴振林 沈卫峰 +2 位作者 于金德 胡厚达 张大东 《Medical Bulletin of Shanghai Jiaotong University》 CAS 1995年第2期19-24,共6页
THECLINICALVALUEOFCOLORDOPPLERFLOWCONVERGENCEINTHEQUANTIFICATIONOFMITRALREGURGITATIONDaiZhenlin(戴振林);ShenWei... THECLINICALVALUEOFCOLORDOPPLERFLOWCONVERGENCEINTHEQUANTIFICATIONOFMITRALREGURGITATIONDaiZhenlin(戴振林);ShenWeifeng(沈卫峰);YuJinde... 展开更多
关键词 MITRAL REGURGITATION echocardiography doppler
下载PDF
Graves' Disease Thyroid Color-Flow Doppler Ultrasonography Assessment: Review Article
20
作者 Thiago Adler Ralho Rodrigues dos Santos Rodrigo Otavio Gomes Pina +1 位作者 Marina Taliberti Pereira de Souza Maria Cristina Chammas 《Health》 2014年第12期1487-1496,共10页
Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenc... Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenced in its development by several factors, including environment (dietary iodine intake, stress, drugs and infections). The disease is characterized by one or more changes: hyperthyroidism, goiter, ophthalmopathy, skin changes and pretibial myxedema, around 5% less common, and other symptoms 90% to 95%. One of the most relevant clinical practice aspects in Graves’ disease patients management is to distinguish Graves’ disease in initial phase, from other types of destructive thyrotoxicosis, in addition to evaluate therapeutic methods and efficient follow up, as well as predict early recurrence or remission of disease. Scintigraphy with pertechnetate (99 mTc) and TSH levels dosage are considered the choice for this purpose. However, they present some technical difficulties, as they are not widely available and have contraindications. In this scenario, thyroid color-flow doppler ultrasonography (US Doppler) presents a viable alternative, as a widely available, low cost, non-invasive and radiation free method, providing initial diagnosis and patients with Graves’ disease follow up. In adittion, this method is used in differential diagnosis with other causes of thyrotoxicosis in the early stage. 展开更多
关键词 THYROID Graves’ Disease ULTRASONOGRAPHY color-Flow doppler
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部