期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Dynamic physical characteristics of DC arc on arcing horn for HVDC grounding electrode line
1
作者 刘益岑 杨晨光 +4 位作者 郭裕钧 张血琴 肖嵩 高国强 吴广宁 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期80-87,共8页
The dynamic physical characteristics of a DC arc on an arcing horn for a high voltage direct current(HVDC)grounding electrode line are significantly different from those of the switching device arc,secondary arc,AC fa... The dynamic physical characteristics of a DC arc on an arcing horn for a high voltage direct current(HVDC)grounding electrode line are significantly different from those of the switching device arc,secondary arc,AC fault arc and pantograph-catenary arc.In this work,an experimental platform for the DC arc on the arcing horn was built,and mechanisms of the arc column short circuit and arc root movement were studied.This work further analyzes the characteristics and mechanisms of the arc motion when wind speed and direction,magnetic field and the expansion angle of the electrode are varied.Arc root movement is more likely to occur at the upper electrode.There is a competitive relationship between arc expansion and the transferring effect.The effect of wind on the arc column is greater than the effect on the arc root.The magnetic field has a significant driving effect on both the arc column and the arc root.The research results provide a comprehensive experimental basis for forther probing the method of DC arc suppression,and the improvement of the arcing horn. 展开更多
关键词 grounding electrode line arcing horn DC arc dynamic physical characteristics
下载PDF
Measured Impedance and Threshold Value of Electrode Line Impedance Supervision Based Protection in HVDC Transmission System 被引量:1
2
作者 Qiang Sun Bin Li +1 位作者 Jiawei He Ye Li 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第4期1294-1304,共11页
At present,electrode line impedance supervision(ELIS)based protection is widely used to detect faults on grounding electrode lines,which are indispensable elements of high-voltage direct current(HVDC)systems.The exist... At present,electrode line impedance supervision(ELIS)based protection is widely used to detect faults on grounding electrode lines,which are indispensable elements of high-voltage direct current(HVDC)systems.The existing theoretical analysis of measured impedance is based on lumped line model and the threshold value is generally set according to engineering experience,which have caused the dead zone problem and even accidents.Therefore,a study on measured impedance of ELIS-based protection and its threshold value selection method is carried out to solve this problem.In this study,the expressions of measured impedance under normal operation and fault conditions are deduced based on rigorous and accurate line model.Based on the expressions,the characteristics of the measured impedance are calculated and analyzed.With the characteristics of the measured impedance,the applicability of the protection with the traditional threshold value is further discussed and the distribution of the dead zone can be located.Then,the method to calculate the threshold value of ELIS-based protection is proposed.With a proper threshold value selected by the proposed method,the dead zone of ELIS-based protection is effectively eliminated,and the protection can identify all types of faults even with large transition resistances.Case studies on PSCAD/EMTDC have been conducted to verify the conclusion. 展开更多
关键词 Grounding electrode line electrode line impedance supervision(ELIS)based protection measured impedance characteristic threshold value selection
原文传递
Research on Common Grounding Electrode Technique in HVDC
3
作者 Chenglian MA 《International Journal of Technology Management》 2015年第1期4-6,共3页
This paper discusses the characteristics of DC transmission common system ground electrode type and shared ground electrode, established the mathematical model of two circuit DC systems share ground electrode, analyze... This paper discusses the characteristics of DC transmission common system ground electrode type and shared ground electrode, established the mathematical model of two circuit DC systems share ground electrode, analyze effects of the shared loop ground DC transmission system electrode on the operation of HVDC system size under different operation modes, and compare with the independent ground electrode, ground electrode impact on environment under different operation mode, and the paper finally puts forward some solving measures for the influence of the shared ground electrode on the environment and public ground electrode effects on DC system operation problems. 展开更多
关键词 HVDC ground electrode line protection DC transmission system TRANSIENT
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部