A gridded thermionic cathode electron gun was developed for the linear accelerator of the High Energy Photon Source(HEPS).An electron gun should provide a large maximum bunch charge with a wide adjustable range.To sat...A gridded thermionic cathode electron gun was developed for the linear accelerator of the High Energy Photon Source(HEPS).An electron gun should provide a large maximum bunch charge with a wide adjustable range.To satisfy these requirements,the shape of the electrode was optimized using a multi-objective genetic algorithm.A large bunch charge with an adjustable range was achieved using the grid-limited gun,the flow of which was analyzed using 3-D simulations.The electron gun has been manufactured and tested,and the measured data of the grid-limited current and simulation results are compared and discussed in this study.展开更多
As one of the most important key technologies for future advanced light source based on the energy recovery linac, a photocathode dc electron gun is supported by Institute of High Energy Physics (IHEP) to address th...As one of the most important key technologies for future advanced light source based on the energy recovery linac, a photocathode dc electron gun is supported by Institute of High Energy Physics (IHEP) to address the technical challenges of producing very low ernittance beams at high average current. Construction of the dc gun is completed and a preliminary high voltage conditioning is carried out up to 440 k V. The design, construction and preliminary HV conditioning results for the dc gun are described.展开更多
In order to develop miniaturized and integrated electron vacuum devices, the electron beam modulation in a field- emission (FE) electron gun based on carbon nanotubes is researched. By feeding a high-frequency field...In order to develop miniaturized and integrated electron vacuum devices, the electron beam modulation in a field- emission (FE) electron gun based on carbon nanotubes is researched. By feeding a high-frequency field between the cathode and the anode, the steady FE electron beam can be modulated in the electron gun. The optimal structure of the electron gun is discovered using 3D electromagnetism simulation software, and the FE electron gun is simulated by PIC simulation software. The results show that a broadband (74-114 GHz) modulation can be achieved by the electron gun with a rhombus channel, and the modulation amplitude of the beam current increases with the increases in the input power and the electrostatic field.展开更多
A new and simple type of electron gun is presented.Unlike conventional electron guns,which require a heated filament or extractor,accelerator and focusing electrodes,this gun uses the collimated electron microchannels...A new and simple type of electron gun is presented.Unlike conventional electron guns,which require a heated filament or extractor,accelerator and focusing electrodes,this gun uses the collimated electron microchannels of an inertial electrostatic confinement(IEC) discharge to achieve the same outcome.A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge.Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode.This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid.The internal operating pressure range of the gun is 35-190 m Torr.A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential.The chamber was operated at pressures of 4-12 m Torr.The measured current produced by the gun was 0.1-3 m A(0.2-14 m A corrected measurement) for discharge currents of 1-45 m A and discharge voltages of 0.5-12 k V.The collimated electron beam emerges from the aperture into the vacuum chamber.The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun.This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required.展开更多
Recent research progresses in Multi-Beam Klystron (MBK) in IECAS are briefly introduced in the letter. The S-band MBKs of IECAS have peak power of 120-250 kW, average power of 4-9 kW, efficiency of 35-45%, gain of 41-...Recent research progresses in Multi-Beam Klystron (MBK) in IECAS are briefly introduced in the letter. The S-band MBKs of IECAS have peak power of 120-250 kW, average power of 4-9 kW, efficiency of 35-45%, gain of 41-46 dB, beam voltage of 15-19 kV, and weight of 40-45 kg. Some key technical problems of MBK are also described and discussed. Among them,improving the design of MBK to obtain the required bandwidth, raising beam transmission to increase average power, eliminating oscillation and spray spectrum, overcoming window breakdown caused by magic mode, reducing breakdown times of electrongun, are most important things for the practical MBK. Besides, further research work in MBK in IECAS is commented.展开更多
This paper reports the simulation of an electron gun. The effects on the beam quality of some parameters on the beam quality were studied and optimal choices were identified. It gives numerical beam qualities for a co...This paper reports the simulation of an electron gun. The effects on the beam quality of some parameters on the beam quality were studied and optimal choices were identified. It gives numerical beam qualities for a common electrostatic triode gun, and the dependencies on design parameters such as electrode geometries and bias voltages to these electrodes are shown. An electron beam of diameter 5 mm with energy of 5 keV was assumed for the simulation process. Some design parameters were identified as variable parameters in the presence of space charge. These parameters are the inclination angle of emission electrode, the applied voltage to the focusing electrode, the gap width between the emission electrode and the focusing electrode and the diameter of the focusing electrode. The triode extraction system is designed and optimized by using CST software (for Particle Beam Simulations). The physical design of the extraction system is given in this paper. From the simulation results, it is concluded that the inclination angle of the emission electrode is optimized at 22.5°, the applied voltage to the focusing electrode was optimized and found to be Vfoc =-600 V, the optimal separation distance (gap between emission electrode and focusing electrode) is 4 mm, and the optimal diameter of the emission electrode is 14 mm. Initial results for these efforts aimed at emittance improvement are also given.展开更多
In the NSC KIPT linac, a neutron source based on a subcritical assembly driven by a 100 MeV/100 kW electron linear accelerator is under design and development. The linear accelerator needs a new high current electron ...In the NSC KIPT linac, a neutron source based on a subcritical assembly driven by a 100 MeV/100 kW electron linear accelerator is under design and development. The linear accelerator needs a new high current electron gun. In this paper, the physical design, mechanical fabrication and beam test of this new electron gun are described. The emission current is designed to be higher than 2 A for the pulse width of 3 ~s with repetition rate of 50 Hz. The gun will operate with a DC high voltage power supply that can provide a high voltage up to 150 kV. Computer simulations and optimizations have been carried out in the design stage, including the gun geometry and beam transport line. The test results of high voltage conditioning and beam test are presented. The operation status of the electron gun system is also included. The basic test results show that the design, manufacture, and operation of the new electron system are basically successful.展开更多
Purpose The research focuses on the simulation of influence of cathode positions on beam current characteristics in the thermionic electron gun.Methods The electricfield distribution,bias voltage range and electron beam...Purpose The research focuses on the simulation of influence of cathode positions on beam current characteristics in the thermionic electron gun.Methods The electricfield distribution,bias voltage range and electron beam quality under different cathode positions were simulated by CST software.Results Changes in the cathode position can cause changes in the electricfield distributions under the cathode emission surface change,thereby changing the size of the effective emitting area and affecting the relationship between the bias voltage and beam current.Conclusions Only when the cathode is installed in the proper positions,the beam current and the bias voltage have an approximately linear proportional relationship.When the cathode is installed improperly,the electron beam emission is disordered,resulting in decreased electron beam quality.展开更多
Modeling multipacting to steady state saturation is of interest in determining the performance of the micro-pulse electron gun. In this paper, a novel method is proposed to calculate the multipacting resonance param- ...Modeling multipacting to steady state saturation is of interest in determining the performance of the micro-pulse electron gun. In this paper, a novel method is proposed to calculate the multipacting resonance param- eters for the gun. This method works well, and the 2-D simulation results suggest that steady state saturation can be achieved in the gun. After saturation the transition from two-surface multipacting to single-surface multipacting occurred, and an extensive range of electron emission time is a suggested way to avoid this kind of transition.展开更多
A novel parallel plate model is proposed that divides the electron cloud into three parts at saturation, and it is studied in detail using both an analytical approach and particle-in-cell (PIC) code simulations. As ...A novel parallel plate model is proposed that divides the electron cloud into three parts at saturation, and it is studied in detail using both an analytical approach and particle-in-cell (PIC) code simulations. As one part of the electron cloud, ribbons modes are suggested by tracking the trajectory of individual particles, and the aim of this mode form is to simplify the progress of the multipacting effect in the parallel plate so as to be eliminated by optimizing RF parameters. The micro-pulse electron gun (MPG) has demonstrated the potential to address the need for high peak and average current electron beams, hence studying the multipacting in MPG is essential. On the basis of studying multipacting in the parallel plate, it is clear that increasing the cavity voltage is of interest in yielding high quality beams in the gun.展开更多
Peking University is designing a new SRF gun that is composed of a quarter wave resonator (QWR) and an elliptical cavity. Compared to the elliptical cavity, the QWR is sufficiently compact at the same frequency and...Peking University is designing a new SRF gun that is composed of a quarter wave resonator (QWR) and an elliptical cavity. Compared to the elliptical cavity, the QWR is sufficiently compact at the same frequency and its electric field is quasi-DC. The RF parameters are determined by optimization of QWR cavity structure and the possible multipacting locations are analyzed by 2D MP simulation. The simulation results show that multipacting is not a critical issue for our optimized cavity structure.展开更多
RF deflecting cavity can be used for bunch length measurement and is designed to diagnose the beam produced by the photocathode electron gun which was built at Tsinghua University for the Thomson scattering experiment...RF deflecting cavity can be used for bunch length measurement and is designed to diagnose the beam produced by the photocathode electron gun which was built at Tsinghua University for the Thomson scattering experiment. Detailed discussion and calculation for measuring the 3.5 MeV bunch and another with further acceleration to 50 MeV, which is under development, are presented. A standing-wave deflecting cavity working at 2856 MHz is designed and the power feeding system has been planned.展开更多
Compared with the traditional image intensifier with phosphor screen readout,the photon-counting imaging detector with charge induction readout is more beneficial in several aspects(e.g.,good imaging properties and t...Compared with the traditional image intensifier with phosphor screen readout,the photon-counting imaging detector with charge induction readout is more beneficial in several aspects(e.g.,good imaging properties and time resolution) to astronomy,reconnaissance,bioluminescence,and materials research.However, the annealing temperature during the tube-making process can affect the properties of the Ge film,and consequently impair the performance of the detector.Therefore,the influence of annealing temperature on Ge film and on the detector is studied in order to determine the crucial parameters.The Ge films are prepared on ceramic and quartz glass by the use of an electron gun.They are analyzed by scanning electron microscope(SEM),high-resistance meter,and X-ray diffraction(XRD).The results show that the optimum substrate and annealing temperature are ceramic plate and 250℃,respectively.展开更多
An RF deffecting cavity used for bunch length measurement has been designed and fabricated at Tsinghua University for the Thomson Scattering X-Ray Source. The cavity is a 2856 MHz, π-mode, 3-cell standing-wave cavity...An RF deffecting cavity used for bunch length measurement has been designed and fabricated at Tsinghua University for the Thomson Scattering X-Ray Source. The cavity is a 2856 MHz, π-mode, 3-cell standing-wave cavity, to diagnose the 3.5 MeV beam produced by photocathode electron gun. With a larger power source, the same cavity will again be used to measure the accelerated beam with energy of 50 MeV before colliding with the laser pulse. The RF design using MAFIA for both the cavity shape and the power coupler is reviewed, followed by presenting the fabrication procedure and bench measurement results of two cavities.展开更多
文摘A gridded thermionic cathode electron gun was developed for the linear accelerator of the High Energy Photon Source(HEPS).An electron gun should provide a large maximum bunch charge with a wide adjustable range.To satisfy these requirements,the shape of the electrode was optimized using a multi-objective genetic algorithm.A large bunch charge with an adjustable range was achieved using the grid-limited gun,the flow of which was analyzed using 3-D simulations.The electron gun has been manufactured and tested,and the measured data of the grid-limited current and simulation results are compared and discussed in this study.
基金Supported by the Innovation and Technology Fund of Institute of High Energy Physics
文摘As one of the most important key technologies for future advanced light source based on the energy recovery linac, a photocathode dc electron gun is supported by Institute of High Energy Physics (IHEP) to address the technical challenges of producing very low ernittance beams at high average current. Construction of the dc gun is completed and a preliminary high voltage conditioning is carried out up to 440 k V. The design, construction and preliminary HV conditioning results for the dc gun are described.
基金Project supported by the National Basic Research Program of China(Grant No.2013CB933603)the National Natural Science Foundation of China(Grant Nos.U1134006 and 61101041)
文摘In order to develop miniaturized and integrated electron vacuum devices, the electron beam modulation in a field- emission (FE) electron gun based on carbon nanotubes is researched. By feeding a high-frequency field between the cathode and the anode, the steady FE electron beam can be modulated in the electron gun. The optimal structure of the electron gun is discovered using 3D electromagnetism simulation software, and the FE electron gun is simulated by PIC simulation software. The results show that a broadband (74-114 GHz) modulation can be achieved by the electron gun with a rhombus channel, and the modulation amplitude of the beam current increases with the increases in the input power and the electrostatic field.
文摘A new and simple type of electron gun is presented.Unlike conventional electron guns,which require a heated filament or extractor,accelerator and focusing electrodes,this gun uses the collimated electron microchannels of an inertial electrostatic confinement(IEC) discharge to achieve the same outcome.A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge.Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode.This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid.The internal operating pressure range of the gun is 35-190 m Torr.A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential.The chamber was operated at pressures of 4-12 m Torr.The measured current produced by the gun was 0.1-3 m A(0.2-14 m A corrected measurement) for discharge currents of 1-45 m A and discharge voltages of 0.5-12 k V.The collimated electron beam emerges from the aperture into the vacuum chamber.The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun.This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required.
文摘Recent research progresses in Multi-Beam Klystron (MBK) in IECAS are briefly introduced in the letter. The S-band MBKs of IECAS have peak power of 120-250 kW, average power of 4-9 kW, efficiency of 35-45%, gain of 41-46 dB, beam voltage of 15-19 kV, and weight of 40-45 kg. Some key technical problems of MBK are also described and discussed. Among them,improving the design of MBK to obtain the required bandwidth, raising beam transmission to increase average power, eliminating oscillation and spray spectrum, overcoming window breakdown caused by magic mode, reducing breakdown times of electrongun, are most important things for the practical MBK. Besides, further research work in MBK in IECAS is commented.
文摘This paper reports the simulation of an electron gun. The effects on the beam quality of some parameters on the beam quality were studied and optimal choices were identified. It gives numerical beam qualities for a common electrostatic triode gun, and the dependencies on design parameters such as electrode geometries and bias voltages to these electrodes are shown. An electron beam of diameter 5 mm with energy of 5 keV was assumed for the simulation process. Some design parameters were identified as variable parameters in the presence of space charge. These parameters are the inclination angle of emission electrode, the applied voltage to the focusing electrode, the gap width between the emission electrode and the focusing electrode and the diameter of the focusing electrode. The triode extraction system is designed and optimized by using CST software (for Particle Beam Simulations). The physical design of the extraction system is given in this paper. From the simulation results, it is concluded that the inclination angle of the emission electrode is optimized at 22.5°, the applied voltage to the focusing electrode was optimized and found to be Vfoc =-600 V, the optimal separation distance (gap between emission electrode and focusing electrode) is 4 mm, and the optimal diameter of the emission electrode is 14 mm. Initial results for these efforts aimed at emittance improvement are also given.
基金Supported by National Natural Science Foundation of China(11075172,11075173)
文摘In the NSC KIPT linac, a neutron source based on a subcritical assembly driven by a 100 MeV/100 kW electron linear accelerator is under design and development. The linear accelerator needs a new high current electron gun. In this paper, the physical design, mechanical fabrication and beam test of this new electron gun are described. The emission current is designed to be higher than 2 A for the pulse width of 3 ~s with repetition rate of 50 Hz. The gun will operate with a DC high voltage power supply that can provide a high voltage up to 150 kV. Computer simulations and optimizations have been carried out in the design stage, including the gun geometry and beam transport line. The test results of high voltage conditioning and beam test are presented. The operation status of the electron gun system is also included. The basic test results show that the design, manufacture, and operation of the new electron system are basically successful.
基金funded by National Natural Science Foundation of China(Nos.51805265,51775527)Natural Science Foundation of Jiangsu Province(No.BK20180472).
文摘Purpose The research focuses on the simulation of influence of cathode positions on beam current characteristics in the thermionic electron gun.Methods The electricfield distribution,bias voltage range and electron beam quality under different cathode positions were simulated by CST software.Results Changes in the cathode position can cause changes in the electricfield distributions under the cathode emission surface change,thereby changing the size of the effective emitting area and affecting the relationship between the bias voltage and beam current.Conclusions Only when the cathode is installed in the proper positions,the beam current and the bias voltage have an approximately linear proportional relationship.When the cathode is installed improperly,the electron beam emission is disordered,resulting in decreased electron beam quality.
基金Supported by National Basic Research Program of China(973 Program)(2011CB808300)National Natural Science Foundation of China(10935011)
文摘Modeling multipacting to steady state saturation is of interest in determining the performance of the micro-pulse electron gun. In this paper, a novel method is proposed to calculate the multipacting resonance param- eters for the gun. This method works well, and the 2-D simulation results suggest that steady state saturation can be achieved in the gun. After saturation the transition from two-surface multipacting to single-surface multipacting occurred, and an extensive range of electron emission time is a suggested way to avoid this kind of transition.
基金Supported by National Basic Research Program of China(973 Program)(2011CB808300)National Natural Science Foundation of China(10935011)
文摘A novel parallel plate model is proposed that divides the electron cloud into three parts at saturation, and it is studied in detail using both an analytical approach and particle-in-cell (PIC) code simulations. As one part of the electron cloud, ribbons modes are suggested by tracking the trajectory of individual particles, and the aim of this mode form is to simplify the progress of the multipacting effect in the parallel plate so as to be eliminated by optimizing RF parameters. The micro-pulse electron gun (MPG) has demonstrated the potential to address the need for high peak and average current electron beams, hence studying the multipacting in MPG is essential. On the basis of studying multipacting in the parallel plate, it is clear that increasing the cavity voltage is of interest in yielding high quality beams in the gun.
基金Supported by National Basic Research Project(2011CB808302)National Natural Science Funds(11075007)
文摘Peking University is designing a new SRF gun that is composed of a quarter wave resonator (QWR) and an elliptical cavity. Compared to the elliptical cavity, the QWR is sufficiently compact at the same frequency and its electric field is quasi-DC. The RF parameters are determined by optimization of QWR cavity structure and the possible multipacting locations are analyzed by 2D MP simulation. The simulation results show that multipacting is not a critical issue for our optimized cavity structure.
基金National Natural Science Foundation of China (10775080)
文摘RF deflecting cavity can be used for bunch length measurement and is designed to diagnose the beam produced by the photocathode electron gun which was built at Tsinghua University for the Thomson scattering experiment. Detailed discussion and calculation for measuring the 3.5 MeV bunch and another with further acceleration to 50 MeV, which is under development, are presented. A standing-wave deflecting cavity working at 2856 MHz is designed and the power feeding system has been planned.
基金supported by the National Natural Science Foundation of China under Grant No.10878005
文摘Compared with the traditional image intensifier with phosphor screen readout,the photon-counting imaging detector with charge induction readout is more beneficial in several aspects(e.g.,good imaging properties and time resolution) to astronomy,reconnaissance,bioluminescence,and materials research.However, the annealing temperature during the tube-making process can affect the properties of the Ge film,and consequently impair the performance of the detector.Therefore,the influence of annealing temperature on Ge film and on the detector is studied in order to determine the crucial parameters.The Ge films are prepared on ceramic and quartz glass by the use of an electron gun.They are analyzed by scanning electron microscope(SEM),high-resistance meter,and X-ray diffraction(XRD).The results show that the optimum substrate and annealing temperature are ceramic plate and 250℃,respectively.
基金Supported by National Natural Science Foundation of China (10775080)
文摘An RF deffecting cavity used for bunch length measurement has been designed and fabricated at Tsinghua University for the Thomson Scattering X-Ray Source. The cavity is a 2856 MHz, π-mode, 3-cell standing-wave cavity, to diagnose the 3.5 MeV beam produced by photocathode electron gun. With a larger power source, the same cavity will again be used to measure the accelerated beam with energy of 50 MeV before colliding with the laser pulse. The RF design using MAFIA for both the cavity shape and the power coupler is reviewed, followed by presenting the fabrication procedure and bench measurement results of two cavities.