The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectr...The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.展开更多
The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of...The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of the Synchrotron Light Center for Experimental Science and Applications in the Middle East(SESAME),Jordan.The experimentally measured results of the relative intensities were compared with the calculated results using the subshell fluorescence yield and the Coster-Kronig transition probabilities recommended by Campbell and the values based on the Dirac-Hartree-Slater model by Puri.The experimental and theoretical results are in agreement.In this work,L XRF relative intensities for the elements Sm,Gd,Tb,Er,Ta,W,Re,Hg,Pb and Bi at energies of 18 keV and 23 keV were measured.展开更多
Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this in...Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this instrumental setup to analyze a Si single crystal and a 50 nm HfO_(2) single-layer film deposited on a Si substrate.展开更多
The accurate analysis of the elemental composition plays a crucial role in the research of functional materials.The emitting characteristic x-ray fluorescence(XRF)photons can be used for precisely discriminating the s...The accurate analysis of the elemental composition plays a crucial role in the research of functional materials.The emitting characteristic x-ray fluorescence(XRF)photons can be used for precisely discriminating the specified element.The detection accuracy of conventional XRF methodology using semiconductor detector is limited by the energy resolution,thus posing a challenge in accurately scaling the actual energy of each XRF photon.We adopt a novel high-resolution x-ray spectrometer based on the superconducting transition-edge sensor(TES)for the XRF spectroscopy measurement of different elements.Properties including high energy resolution,high detection efficiency and precise linearity of the new spectrometer will bring significant benefits in analyzing elemental composition via XRF.In this paper,we study the Ledge emission line profiles of three adjacent rare earth elements with the evenly mixed sample of their oxide components:terbium,dysprosium and holmium.Two orders of magnitude better energy resolution are obtained compared to a commercial silicon drift detector.With this TES-based spectrometer,the spectral lines overlapped or interfered by background can be clearly distinguished,thus making the chemical component analysis more accurate and quantitative.A database of coefficient values for the line strength of the spectrum can then be constructed thereafter.Equipped with the novel XRF spectrometer and an established coefficient database,a direct analysis of the composition proportion of a certain element in an unknown sample can be achieved with high accuracy.展开更多
The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectro...The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectrometry, sometimes it exceeds the quality control limit.Influences, such as current, voltage, equipment(internal circulating water, 10%CH4+90%Ar, and vacuum) checking, instrument monitoring, sample cleaning, and oper-ators, were investigated by means of 6-sigma and lean operations to improve accuracy.展开更多
Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in therm...Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in thermal power plants,the measurement repeatability of LIBS needs to be further improved due to the difficulty in controlling the stability of the generated plasmas at present.In this paper,we propose a novel x-ray fluorescence(XRF) assisted LIBS method for high repeatability analysis of coal quality,which not only inherits the ability of LIBS to directly analyze organic elements such as C and H in coal,but also uses XRF to make up for the lack of stability of LIBS in determining other inorganic ash-forming elements.With the combination of elemental lines in LIBS and XRF spectra,the principal component analysis and the partial least squares are used to establish the prediction model and perform multi-elemental and proximate analysis of coal.Quantitative analysis results show that the relative standard deviation(RSD) of C is 0.15%,the RSDs of other elements are less than 4%,and the standard deviations of calorific value,ash content,sulfur content and volatile matter are 0.11 MJ kg,0.17%,0.79% and 0.41%respectively,indicating that the method has good repeatability in determination of coal quality.This work is helpful to accelerate the development of LIBS in the field of rapid measurement of coal entering the power plant and on-line monitoring of coal entering the furnace.展开更多
X-ray fluorescence (XRF) analysis utilizes particle size which is resulted from milling of a material. The milling ensures uniform and fine grained powder. The finer and more uniform the particle size is, the better t...X-ray fluorescence (XRF) analysis utilizes particle size which is resulted from milling of a material. The milling ensures uniform and fine grained powder. The finer and more uniform the particle size is, the better the result and easier it is for material quality control. To ensure uniformity in particle size and finer powder, a comparative analysis was conducted with different grinding aids and pressed pellet method was used in obtaining analysis results. Pressed pellets of cement raw meal sample milled with different grinding aids (graphite, aspirin and lithium borate) were subjected to XRF. Graphite produced better particle size uniformity with a corresponding standard deviation that made quality control of raw meal easier and better than aspirin and lithium borate.展开更多
Analysis of six heavy metals (Cr, Mn, Ni, Cu, Zn and Mo) in human scalp hair was carried out among various occupational distributions to ascertain their heavy metal burden, using energy dispersive x-ray fluorescence t...Analysis of six heavy metals (Cr, Mn, Ni, Cu, Zn and Mo) in human scalp hair was carried out among various occupational distributions to ascertain their heavy metal burden, using energy dispersive x-ray fluorescence technique (ED-XRF). The result of the analysis shows that mean concentrations (mg/kg) of heavy metals obtained were as follows: Cr = 17.1 ± 12.7;Mn = 3.11 ± 0.50;Ni = 11.3 ± 9.3;Zn = 451 ± 128;Cu = 83.3 ± 35.8 and Mo is 9.16 ± 9.1.While the mean concentrations of Cr, Cu, and Mo were higher in the females, that of Mn, Ni and Zn were more in the males. Statistical analysis of the results for both genders at 0.05 probably shows significant difference for Ni, Zn and Mo while Cr, Mn and Cu showed no significant difference. The relationships between age, body mass, height, and heavy metal concentrations were also investigated. Statistical analysis of the results indicates that there was no correlation between the body mass (R2 ≤ 0.048), height (R2 ≤ 0.002) and heavy metal concentration in hair. Zn showed the highest deviation among other elements in the individual samples for both genders which reflect the individual variation in the concentration of Zn.展开更多
Eight water bottles from Ebrie lagoon with pollution potency were studied using nuclear chemistry technique and Energy dispersive X-ray fluorescence. This pollution is characterized by pH and conductivity parameters, ...Eight water bottles from Ebrie lagoon with pollution potency were studied using nuclear chemistry technique and Energy dispersive X-ray fluorescence. This pollution is characterized by pH and conductivity parameters, concentrations average in mg/L of metals such Fe (0.731), Mn (0.345), Cr (0.070), Cu (0.014) and concentrations of nutrients known to be pollutants and toxic for living or-ganisms. These heavy metals are dangerous to the lives, the local inhabitants and also a threat to aquatic life since this water is essential for the economical town, Abidjan. According to the Manganese concentration average (0.345 mg) values that higher than WHO (0.05 mg) value, the main likely source of pollu-tants is anthropogenic, industrial and agricultural. This study also shows the use of materials and lubricants near the lagoon that pollute this water.展开更多
High-throughput powder X-ray diffraction(XRD)with white X-ray beam and an energy-dispersive detector array is demonstrated in this work on a CeO;powder sample on a bending magnet synchrotron beamline at the Shanghai S...High-throughput powder X-ray diffraction(XRD)with white X-ray beam and an energy-dispersive detector array is demonstrated in this work on a CeO;powder sample on a bending magnet synchrotron beamline at the Shanghai Synchrotron Radiation Facility(SSRF),using a simulated energy-dispersive array detector consisting of a spatially scanning silicon-drift detector(SDD).Careful analysis and corrections are applied to account for various experimental hardware-related and diffraction angle-related factors.The resulting diffraction patterns show that the relative strength between different diffraction peaks from energy-dispersive XRD(EDXRD)spectra is consistent with that from angle-resolved XRD(ARXRD),which is necessary for analyzing crystal structures for unknown samples.The X-ray fluorescence(XRF)signal is collected simultaneously.XRF counts from all pixels are integrated directly by energy,while the diffraction spectra are integrated by d-spacing,resulting in a much improved peak strength and signal-to-noise(S/N)ratio for the array detector.In comparison with ARXRD,the diffraction signal generated by a white X-ray beam over monochromic light under the experimental conditions is about 104 times higher.The full width at half maximum(FWHM)of the peaks in q-space is found to be dependent on the energy resolution of the detector,the angle span of the detector,and the diffraction angle.It is possible for EDXRD to achieve the same or even smaller FWHM as ARXRD under the energy resolution of the current detector if the experimental parameters are properly chosen.展开更多
Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reco...Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reconstruction.The main objectives were:(1)calculating the quantum efficiency curves of specific cameras,(2)studying the relationships between the spatial resolution and the pinhole diameter,magnification,and camera binning value,and(3)comparing image-processing methods for pinhole camera systems.Several results were obtained using a point and plane source as the X-ray fluorescence emitter and an array of 100×100 silicon pixel detectors as the X-ray camera.The quantum efficiency of a back-illuminated deep depletion(BI-DD)structure was above 30%for the XRF energies in the 0.8–9 keV range,with the maximum of 93.7%at 4 keV.The best spatial resolution of the pinhole camera was 24.7μm and 31.3 lp/mm when measured using the profile function of the point source,with the diameter of 20μm,magnification of 3.16,and camera bin of 1.A blind deconvolution algorithm with Gaussian filtering performed better than the Wiener filter and Richardson iterative methods on FF-XRF images,with the signal-to-noise ratio of 7.81 dB and improved signalto-noise ratio of 7.24 dB at the diameter of 120μm,magnification of 1.0,and camera bin of 1.展开更多
X-ray fluorescence spectrometry was used to detect the content of eight elements in metal coating smeared on waste plastics,and effects of sample cups,elements in plastic substrate,and interaction of elements in metal...X-ray fluorescence spectrometry was used to detect the content of eight elements in metal coating smeared on waste plastics,and effects of sample cups,elements in plastic substrate,and interaction of elements in metal coating on detection results were analyzed. The results show that the RSD of the method used to detect element content in the metal coating smeared on the waste plastics ranged from 0.008% to 0.044%; the determination range of the eight elements was 0.002%-52.0%,and their detection limit ranged from 0.0002% to 0.0008%. The determination results of X-ray fluorescence spectrometry were consistent with that of ICP-AES. The method can provide technical support for the determination of damage and pollution caused by metal coating smeared on waste plastics.展开更多
The structure around Ti<sup>4+</sup> in BaO-SiO<sub>2</sub>-B<sub>2</sub>O<sub>3</sub>-TiO<sub>2</sub> had been studied by X-ray fluorescence spectra. The re...The structure around Ti<sup>4+</sup> in BaO-SiO<sub>2</sub>-B<sub>2</sub>O<sub>3</sub>-TiO<sub>2</sub> had been studied by X-ray fluorescence spectra. The results show that the Ti<sup>4+</sup> mainly exists in the [TiO<sub>4</sub>] and enters the network of [SiO<sub>4</sub>]. [TiO<sub>4</sub>] has the tendency to change to [TiO<sub>6</sub>] with the increase of TiO<sub>2</sub> content. When the TiO<sub>2</sub> content increases to about 20mol% the tendency reaches its maximum.展开更多
We present the analysis of gold in plating solutions in the presence of several additive ions by portable X-ray fluorescence (XRF) revealing an optimum potassium gold cyanide concentration of 2 - 3 g/L for maximum cat...We present the analysis of gold in plating solutions in the presence of several additive ions by portable X-ray fluorescence (XRF) revealing an optimum potassium gold cyanide concentration of 2 - 3 g/L for maximum cathode efficiency. Additionally, we present the utility of XRF to determine the thickness of gold plated on copper substrates up to 6 microns.展开更多
A quantitative analysis method of molybdenum in FeMo alloys by X-ray spectrometry using borate fusion technique was compared with that with pressed pellet. The complete pre-oxidation of FeMo alloys for the preparation...A quantitative analysis method of molybdenum in FeMo alloys by X-ray spectrometry using borate fusion technique was compared with that with pressed pellet. The complete pre-oxidation of FeMo alloys for the preparation of homogeneous fused discs was achieved by employing an automated fusion machine equipped with specially designed O2-blowing nozzles, which used lithium tetra-borate as flux with the addition of lithium nitrate (LiNO3) as oxidizer. The calibration curves of Mo and Fe were used in the quantitative analysis of standard materials and unknown plant samples with satisfactory accuracy and precision, utilizing the corrections of the matrix effects and line overlap. It was confirmed that the newly proposed method of preparing fused glass discs of FeMo alloys can replace the conventional wet chemical analyses requiring the labor intensive and time consuming procedure.展开更多
Lα, Lβ, and Lγ X-ray fluorescence cross sections for Ho and Yb have been measured at various incident photon energies in the energy range 16.04 ≤ E ≤ 24.68 keV. The measurements have been done using an X-ray tube...Lα, Lβ, and Lγ X-ray fluorescence cross sections for Ho and Yb have been measured at various incident photon energies in the energy range 16.04 ≤ E ≤ 24.68 keV. The measurements have been done using an X-ray tube with a secondary-excitor system of Zr, Nb, Mo, Cd, and In. The experimental values of the cross-sections were determined by measuring the absolute yield of L subshell X-rays emitted from a standard target of a given energy. Theoretical tabulated values of subshell photoionization cross-sections, fluorescence yields, Coster-Kronig transition probabilities and radioactive decay rates have been used to calculate the theoretical values of the cross-sections. The experimental results of the cross-sections at various excitation energies have been compared with theoretically calculated values. Fairly good agreement is obtained between the present experimental results and the calculated values.展开更多
Coupling equations used to calculate the chemical composition of substances by X-ray fluorescence analysis can be classified as empirical, theoretical or semi-empirical based on the method for determining the coeffici...Coupling equations used to calculate the chemical composition of substances by X-ray fluorescence analysis can be classified as empirical, theoretical or semi-empirical based on the method for determining the coefficients of the calibration function. The advantages and disadvantages of each class of equations are discussed. Recommendations for the selecting the optimum conditions for determining empirical correction coefficients and their control during analysis are provided.展开更多
Igneous and sedimentary rocks contain an amount of natural radioactivity (NORM). U-238, Th-232 and their decay products, and K-40 are important sources of gamma-radiation. Knowledge of the radionuclide content of rock...Igneous and sedimentary rocks contain an amount of natural radioactivity (NORM). U-238, Th-232 and their decay products, and K-40 are important sources of gamma-radiation. Knowledge of the radionuclide content of rocks is necessary to estimate the exposure of the population to the radiation. Many types of rocks are used in building and industries, thus the radiation detection is important, it provides a baseline map of levels of the radioactivity in the study region. The purpose of this study is to evaluate the activity concentrations of the natural radionuclides (U-238 (Ra-226), Th-232 and K-40) and the fallout nuclide (Cs-137) (if found) in thirty samples of igneous and sedimentary rocks of Al-Atawilah (Al-Baha). The samples were collected and prepared during 2018/2019, and analyzed with a good experimental instrument (High energy resolution γ-ray spectroscopy with HPGe detector), also these rock samples were analyzed with X-ray fluorescence to subdivided these rocks based on the major oxides proportions contained of each sample. The mean activity concentrations of naturally radionuclides were found in the igneous rock samples varied depending on the type of the igneous rock. For sedimentary rock samples, the activity concentrations were found high for quartz sandstone sample, which may be due to its high proportion of SiO<sub>2</sub> and K<sub>2</sub>O. The estimated mean values of absorbed dose rate are within the permissible limit value. The findings indicate high dose level values in granite (rhyolite) and most of diorite (andesite) igneous rock samples while gabbro (basalt) igneous rock samples (except for one sample) record low levels of dose rate. All sedimentary rock samples have low dose rate (except for the quartz sand-stone sample).展开更多
This work focuses on the analysis of the chemical composition of soils dedicated to agriculture in order to assess the impacts of manganese mining activity in the city of Moanda in South-East Gabon. The result of the ...This work focuses on the analysis of the chemical composition of soils dedicated to agriculture in order to assess the impacts of manganese mining activity in the city of Moanda in South-East Gabon. The result of the analysis obtained using wavelength dispersive X-ray fluorescence revealed the presence of twenty-seven elements in the seventeen soil samples collected namely: Na, K, Rb, Mg, Ca, Sr, Ba, Ti, Fe, Co, Ni, Cu, Zn, Y, Zr, Nb, Cr, Mn, Al, O, C, P, S, Si, I, Ac and Th. Iron (Fe), aluminum (Al) and manganese (Mn) were respectively higher. The practice of agriculture near mining sites is not without risks for the quality of agricultural products and the health of the population.展开更多
Ischemic stroke is one of the leading causes of death worldwide,and effective treatment strategies in the chronic phase of this disease remain insufficient.Homeostasis of metals in the brain plays an important role in...Ischemic stroke is one of the leading causes of death worldwide,and effective treatment strategies in the chronic phase of this disease remain insufficient.Homeostasis of metals in the brain plays an important role in maintaining normal brain function.However,the dynamic spatial distributions of iron,zinc,calcium,potassium,and copper in a rat brain following ischemic stroke and the association between structural distribution and function remain to be elucidated.In this study,we used a synchrotron radiation-based micro-X-ray fluorescence technique to image element mapping changes in special rat brain regions after ischemic stroke,showing the distribution characteristics of iron,zinc,calcium,potassium,and copper.We demonstrated,for the first time,the consistent dynamic spatial distributions of metal elements at a series of time points(3 h,4.5 h,6 h,12 h,1 d,3 d,5 d,7 d,10 d,14 d,28 d)after brain ischemia,which revealed that the homeostasis of iron,zinc,calcium,potassium,and copper in the brain was disturbed with distinctive change trends,providing clear insights in understanding the underlying pathogenesis of stroke from a novel perspective,thus laying the foundation of further developing new drug targets for stroke treatment.展开更多
基金supported by the National Key R&D Project of China(No.2017YFC0602100)the National Natural Science Foundation of China(No.41774147)Sichuan Science and Technology Support Program(No.2015GZ0272)
文摘The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.
基金supported by the Jordan University of Science and Technology(Grant No.20180167)the SESAME Synchrotron Center Jordan(Grant No.20185004)。
文摘The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of the Synchrotron Light Center for Experimental Science and Applications in the Middle East(SESAME),Jordan.The experimentally measured results of the relative intensities were compared with the calculated results using the subshell fluorescence yield and the Coster-Kronig transition probabilities recommended by Campbell and the values based on the Dirac-Hartree-Slater model by Puri.The experimental and theoretical results are in agreement.In this work,L XRF relative intensities for the elements Sm,Gd,Tb,Er,Ta,W,Re,Hg,Pb and Bi at energies of 18 keV and 23 keV were measured.
基金Project supported by the National Key Research and Development Program of China(Grant No.2021YFF0701202)the National Natural Science Foundation of China(Grant No.11875087)。
文摘Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this instrumental setup to analyze a Si single crystal and a 50 nm HfO_(2) single-layer film deposited on a Si substrate.
基金the National Major Scientific Research Instrument Development Project(Grant No.11927805)the National Key Research and Development Program of China(Grant No.2022YFF0608303)+2 种基金the NSFC Young Scientists Fund(Grant No.12005134)the Shanghai-XFEL Beamline Project(SBP)(Grant No.31011505505885920161A2101001)the Shanghai Municipal Science and Technology Major Project(Grant No.2017SHZDZX02)。
文摘The accurate analysis of the elemental composition plays a crucial role in the research of functional materials.The emitting characteristic x-ray fluorescence(XRF)photons can be used for precisely discriminating the specified element.The detection accuracy of conventional XRF methodology using semiconductor detector is limited by the energy resolution,thus posing a challenge in accurately scaling the actual energy of each XRF photon.We adopt a novel high-resolution x-ray spectrometer based on the superconducting transition-edge sensor(TES)for the XRF spectroscopy measurement of different elements.Properties including high energy resolution,high detection efficiency and precise linearity of the new spectrometer will bring significant benefits in analyzing elemental composition via XRF.In this paper,we study the Ledge emission line profiles of three adjacent rare earth elements with the evenly mixed sample of their oxide components:terbium,dysprosium and holmium.Two orders of magnitude better energy resolution are obtained compared to a commercial silicon drift detector.With this TES-based spectrometer,the spectral lines overlapped or interfered by background can be clearly distinguished,thus making the chemical component analysis more accurate and quantitative.A database of coefficient values for the line strength of the spectrum can then be constructed thereafter.Equipped with the novel XRF spectrometer and an established coefficient database,a direct analysis of the composition proportion of a certain element in an unknown sample can be achieved with high accuracy.
文摘The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectrometry, sometimes it exceeds the quality control limit.Influences, such as current, voltage, equipment(internal circulating water, 10%CH4+90%Ar, and vacuum) checking, instrument monitoring, sample cleaning, and oper-ators, were investigated by means of 6-sigma and lean operations to improve accuracy.
基金supported by National Energy R&D Center of Petroleum Refining Technology of China(RIPP,SINOPEC)National Key Research and Development Program of China(No.2017YFA0304203)+5 种基金Changjiang Scholars and Innovative Research Team in University of Ministry of Education of China(No.IRT_17R70)National Natural Science Foundation of China(Nos.61975103,61875108,61775125 and 11434007)Industrial Application Innovation Project(No.627010407)Scientific and Technological Innovation Project of Shanxi Gemeng US-China Clean Energy R&D Center Co.,Ltd111 Project(D18001)Fund for Shanxi‘1331KSC’。
文摘Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in thermal power plants,the measurement repeatability of LIBS needs to be further improved due to the difficulty in controlling the stability of the generated plasmas at present.In this paper,we propose a novel x-ray fluorescence(XRF) assisted LIBS method for high repeatability analysis of coal quality,which not only inherits the ability of LIBS to directly analyze organic elements such as C and H in coal,but also uses XRF to make up for the lack of stability of LIBS in determining other inorganic ash-forming elements.With the combination of elemental lines in LIBS and XRF spectra,the principal component analysis and the partial least squares are used to establish the prediction model and perform multi-elemental and proximate analysis of coal.Quantitative analysis results show that the relative standard deviation(RSD) of C is 0.15%,the RSDs of other elements are less than 4%,and the standard deviations of calorific value,ash content,sulfur content and volatile matter are 0.11 MJ kg,0.17%,0.79% and 0.41%respectively,indicating that the method has good repeatability in determination of coal quality.This work is helpful to accelerate the development of LIBS in the field of rapid measurement of coal entering the power plant and on-line monitoring of coal entering the furnace.
文摘X-ray fluorescence (XRF) analysis utilizes particle size which is resulted from milling of a material. The milling ensures uniform and fine grained powder. The finer and more uniform the particle size is, the better the result and easier it is for material quality control. To ensure uniformity in particle size and finer powder, a comparative analysis was conducted with different grinding aids and pressed pellet method was used in obtaining analysis results. Pressed pellets of cement raw meal sample milled with different grinding aids (graphite, aspirin and lithium borate) were subjected to XRF. Graphite produced better particle size uniformity with a corresponding standard deviation that made quality control of raw meal easier and better than aspirin and lithium borate.
文摘Analysis of six heavy metals (Cr, Mn, Ni, Cu, Zn and Mo) in human scalp hair was carried out among various occupational distributions to ascertain their heavy metal burden, using energy dispersive x-ray fluorescence technique (ED-XRF). The result of the analysis shows that mean concentrations (mg/kg) of heavy metals obtained were as follows: Cr = 17.1 ± 12.7;Mn = 3.11 ± 0.50;Ni = 11.3 ± 9.3;Zn = 451 ± 128;Cu = 83.3 ± 35.8 and Mo is 9.16 ± 9.1.While the mean concentrations of Cr, Cu, and Mo were higher in the females, that of Mn, Ni and Zn were more in the males. Statistical analysis of the results for both genders at 0.05 probably shows significant difference for Ni, Zn and Mo while Cr, Mn and Cu showed no significant difference. The relationships between age, body mass, height, and heavy metal concentrations were also investigated. Statistical analysis of the results indicates that there was no correlation between the body mass (R2 ≤ 0.048), height (R2 ≤ 0.002) and heavy metal concentration in hair. Zn showed the highest deviation among other elements in the individual samples for both genders which reflect the individual variation in the concentration of Zn.
文摘Eight water bottles from Ebrie lagoon with pollution potency were studied using nuclear chemistry technique and Energy dispersive X-ray fluorescence. This pollution is characterized by pH and conductivity parameters, concentrations average in mg/L of metals such Fe (0.731), Mn (0.345), Cr (0.070), Cu (0.014) and concentrations of nutrients known to be pollutants and toxic for living or-ganisms. These heavy metals are dangerous to the lives, the local inhabitants and also a threat to aquatic life since this water is essential for the economical town, Abidjan. According to the Manganese concentration average (0.345 mg) values that higher than WHO (0.05 mg) value, the main likely source of pollu-tants is anthropogenic, industrial and agricultural. This study also shows the use of materials and lubricants near the lagoon that pollute this water.
基金supported by the National Key Research and Development Program of China,China(2017YFB0701900)High-Level Special Funds(G02256401 and G02256301)+1 种基金supported by the fund of the Guangdong Provincial Key Laboratory(2018B030322001)the Guangdong-Hong Kong-Macao Joint Laboratory(2019B121205001)。
文摘High-throughput powder X-ray diffraction(XRD)with white X-ray beam and an energy-dispersive detector array is demonstrated in this work on a CeO;powder sample on a bending magnet synchrotron beamline at the Shanghai Synchrotron Radiation Facility(SSRF),using a simulated energy-dispersive array detector consisting of a spatially scanning silicon-drift detector(SDD).Careful analysis and corrections are applied to account for various experimental hardware-related and diffraction angle-related factors.The resulting diffraction patterns show that the relative strength between different diffraction peaks from energy-dispersive XRD(EDXRD)spectra is consistent with that from angle-resolved XRD(ARXRD),which is necessary for analyzing crystal structures for unknown samples.The X-ray fluorescence(XRF)signal is collected simultaneously.XRF counts from all pixels are integrated directly by energy,while the diffraction spectra are integrated by d-spacing,resulting in a much improved peak strength and signal-to-noise(S/N)ratio for the array detector.In comparison with ARXRD,the diffraction signal generated by a white X-ray beam over monochromic light under the experimental conditions is about 104 times higher.The full width at half maximum(FWHM)of the peaks in q-space is found to be dependent on the energy resolution of the detector,the angle span of the detector,and the diffraction angle.It is possible for EDXRD to achieve the same or even smaller FWHM as ARXRD under the energy resolution of the current detector if the experimental parameters are properly chosen.
基金supported by the Sichuan Science and Technology Program,China(No.2020ZDZX0004)。
文摘Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reconstruction.The main objectives were:(1)calculating the quantum efficiency curves of specific cameras,(2)studying the relationships between the spatial resolution and the pinhole diameter,magnification,and camera binning value,and(3)comparing image-processing methods for pinhole camera systems.Several results were obtained using a point and plane source as the X-ray fluorescence emitter and an array of 100×100 silicon pixel detectors as the X-ray camera.The quantum efficiency of a back-illuminated deep depletion(BI-DD)structure was above 30%for the XRF energies in the 0.8–9 keV range,with the maximum of 93.7%at 4 keV.The best spatial resolution of the pinhole camera was 24.7μm and 31.3 lp/mm when measured using the profile function of the point source,with the diameter of 20μm,magnification of 3.16,and camera bin of 1.A blind deconvolution algorithm with Gaussian filtering performed better than the Wiener filter and Richardson iterative methods on FF-XRF images,with the signal-to-noise ratio of 7.81 dB and improved signalto-noise ratio of 7.24 dB at the diameter of 120μm,magnification of 1.0,and camera bin of 1.
基金Supported by Project of Ningbo Entry-Exit Inspection and Quarantine Bureau(K21-2013)
文摘X-ray fluorescence spectrometry was used to detect the content of eight elements in metal coating smeared on waste plastics,and effects of sample cups,elements in plastic substrate,and interaction of elements in metal coating on detection results were analyzed. The results show that the RSD of the method used to detect element content in the metal coating smeared on the waste plastics ranged from 0.008% to 0.044%; the determination range of the eight elements was 0.002%-52.0%,and their detection limit ranged from 0.0002% to 0.0008%. The determination results of X-ray fluorescence spectrometry were consistent with that of ICP-AES. The method can provide technical support for the determination of damage and pollution caused by metal coating smeared on waste plastics.
文摘The structure around Ti<sup>4+</sup> in BaO-SiO<sub>2</sub>-B<sub>2</sub>O<sub>3</sub>-TiO<sub>2</sub> had been studied by X-ray fluorescence spectra. The results show that the Ti<sup>4+</sup> mainly exists in the [TiO<sub>4</sub>] and enters the network of [SiO<sub>4</sub>]. [TiO<sub>4</sub>] has the tendency to change to [TiO<sub>6</sub>] with the increase of TiO<sub>2</sub> content. When the TiO<sub>2</sub> content increases to about 20mol% the tendency reaches its maximum.
文摘We present the analysis of gold in plating solutions in the presence of several additive ions by portable X-ray fluorescence (XRF) revealing an optimum potassium gold cyanide concentration of 2 - 3 g/L for maximum cathode efficiency. Additionally, we present the utility of XRF to determine the thickness of gold plated on copper substrates up to 6 microns.
文摘A quantitative analysis method of molybdenum in FeMo alloys by X-ray spectrometry using borate fusion technique was compared with that with pressed pellet. The complete pre-oxidation of FeMo alloys for the preparation of homogeneous fused discs was achieved by employing an automated fusion machine equipped with specially designed O2-blowing nozzles, which used lithium tetra-borate as flux with the addition of lithium nitrate (LiNO3) as oxidizer. The calibration curves of Mo and Fe were used in the quantitative analysis of standard materials and unknown plant samples with satisfactory accuracy and precision, utilizing the corrections of the matrix effects and line overlap. It was confirmed that the newly proposed method of preparing fused glass discs of FeMo alloys can replace the conventional wet chemical analyses requiring the labor intensive and time consuming procedure.
文摘Lα, Lβ, and Lγ X-ray fluorescence cross sections for Ho and Yb have been measured at various incident photon energies in the energy range 16.04 ≤ E ≤ 24.68 keV. The measurements have been done using an X-ray tube with a secondary-excitor system of Zr, Nb, Mo, Cd, and In. The experimental values of the cross-sections were determined by measuring the absolute yield of L subshell X-rays emitted from a standard target of a given energy. Theoretical tabulated values of subshell photoionization cross-sections, fluorescence yields, Coster-Kronig transition probabilities and radioactive decay rates have been used to calculate the theoretical values of the cross-sections. The experimental results of the cross-sections at various excitation energies have been compared with theoretically calculated values. Fairly good agreement is obtained between the present experimental results and the calculated values.
文摘Coupling equations used to calculate the chemical composition of substances by X-ray fluorescence analysis can be classified as empirical, theoretical or semi-empirical based on the method for determining the coefficients of the calibration function. The advantages and disadvantages of each class of equations are discussed. Recommendations for the selecting the optimum conditions for determining empirical correction coefficients and their control during analysis are provided.
文摘Igneous and sedimentary rocks contain an amount of natural radioactivity (NORM). U-238, Th-232 and their decay products, and K-40 are important sources of gamma-radiation. Knowledge of the radionuclide content of rocks is necessary to estimate the exposure of the population to the radiation. Many types of rocks are used in building and industries, thus the radiation detection is important, it provides a baseline map of levels of the radioactivity in the study region. The purpose of this study is to evaluate the activity concentrations of the natural radionuclides (U-238 (Ra-226), Th-232 and K-40) and the fallout nuclide (Cs-137) (if found) in thirty samples of igneous and sedimentary rocks of Al-Atawilah (Al-Baha). The samples were collected and prepared during 2018/2019, and analyzed with a good experimental instrument (High energy resolution γ-ray spectroscopy with HPGe detector), also these rock samples were analyzed with X-ray fluorescence to subdivided these rocks based on the major oxides proportions contained of each sample. The mean activity concentrations of naturally radionuclides were found in the igneous rock samples varied depending on the type of the igneous rock. For sedimentary rock samples, the activity concentrations were found high for quartz sandstone sample, which may be due to its high proportion of SiO<sub>2</sub> and K<sub>2</sub>O. The estimated mean values of absorbed dose rate are within the permissible limit value. The findings indicate high dose level values in granite (rhyolite) and most of diorite (andesite) igneous rock samples while gabbro (basalt) igneous rock samples (except for one sample) record low levels of dose rate. All sedimentary rock samples have low dose rate (except for the quartz sand-stone sample).
文摘This work focuses on the analysis of the chemical composition of soils dedicated to agriculture in order to assess the impacts of manganese mining activity in the city of Moanda in South-East Gabon. The result of the analysis obtained using wavelength dispersive X-ray fluorescence revealed the presence of twenty-seven elements in the seventeen soil samples collected namely: Na, K, Rb, Mg, Ca, Sr, Ba, Ti, Fe, Co, Ni, Cu, Zn, Y, Zr, Nb, Cr, Mn, Al, O, C, P, S, Si, I, Ac and Th. Iron (Fe), aluminum (Al) and manganese (Mn) were respectively higher. The practice of agriculture near mining sites is not without risks for the quality of agricultural products and the health of the population.
基金This work was supported by the National Natural Science Foundation of China(No.81501025)the Natural Science Foundation of Hunan Province(Nos.2020JJ4134 and 2016JJ3174).
文摘Ischemic stroke is one of the leading causes of death worldwide,and effective treatment strategies in the chronic phase of this disease remain insufficient.Homeostasis of metals in the brain plays an important role in maintaining normal brain function.However,the dynamic spatial distributions of iron,zinc,calcium,potassium,and copper in a rat brain following ischemic stroke and the association between structural distribution and function remain to be elucidated.In this study,we used a synchrotron radiation-based micro-X-ray fluorescence technique to image element mapping changes in special rat brain regions after ischemic stroke,showing the distribution characteristics of iron,zinc,calcium,potassium,and copper.We demonstrated,for the first time,the consistent dynamic spatial distributions of metal elements at a series of time points(3 h,4.5 h,6 h,12 h,1 d,3 d,5 d,7 d,10 d,14 d,28 d)after brain ischemia,which revealed that the homeostasis of iron,zinc,calcium,potassium,and copper in the brain was disturbed with distinctive change trends,providing clear insights in understanding the underlying pathogenesis of stroke from a novel perspective,thus laying the foundation of further developing new drug targets for stroke treatment.