The current situation about the natural forest resources protection project in Haikou Forest Farm of Kunming on the protection of forest resources, forest fire prevention, forest administration resource management, fo...The current situation about the natural forest resources protection project in Haikou Forest Farm of Kunming on the protection of forest resources, forest fire prevention, forest administration resource management, forest pests, and money management was briefed. Achievements made in the implementation of natural forest protection project in Haikou Forest Farm were analyzed, and problems existing in the project as well as corresponding countermeasures were expounded.展开更多
Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capa...Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaafarana, Egypt. The simulation results show the influence of the FRT capability on the protective relaying coordination in wind farms, showing that the FRT may work in situations where is were expected not to work, and then disabling the over-current protection, which should have worked in this situation.展开更多
基金Sponsored by Science and Technology Projects of Kunming(2015-1-S-00643)
文摘The current situation about the natural forest resources protection project in Haikou Forest Farm of Kunming on the protection of forest resources, forest fire prevention, forest administration resource management, forest pests, and money management was briefed. Achievements made in the implementation of natural forest protection project in Haikou Forest Farm were analyzed, and problems existing in the project as well as corresponding countermeasures were expounded.
文摘Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaafarana, Egypt. The simulation results show the influence of the FRT capability on the protective relaying coordination in wind farms, showing that the FRT may work in situations where is were expected not to work, and then disabling the over-current protection, which should have worked in this situation.