期刊文献+
共找到20篇文章
< 1 >
每页显示 20 50 100
Semi-analytical solution for mechanical analysis of tunnels crossing strike-slip fault zone considering nonuniform fault displacement and uncertain fault plane position
1
作者 YANG Heng-hong WANG Ming-nian +1 位作者 YU Li ZHANG Xiao 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第6期2116-2136,共21页
The tunnel subjected to strike-slip fault dislocation exhibits severe and catastrophic damage.The existing analysis models frequently assume uniform fault displacement and fixed fault plane position.In contrast,post-e... The tunnel subjected to strike-slip fault dislocation exhibits severe and catastrophic damage.The existing analysis models frequently assume uniform fault displacement and fixed fault plane position.In contrast,post-earthquake observations indicate that the displacement near the fault zone is typically nonuniform,and the fault plane position is uncertain.In this study,we first established a series of improved governing equations to analyze the mechanical response of tunnels under strike-slip fault dislocation.The proposed methodology incorporated key factors such as nonuniform fault displacement and uncertain fault plane position into the governing equations,thereby significantly enhancing the applicability range and accuracy of the model.In contrast to previous analytical models,the maximum computational error has decreased from 57.1%to 1.1%.Subsequently,we conducted a rigorous validation of the proposed methodology by undertaking a comparative analysis with a 3D finite element numerical model,and the results from both approaches exhibited a high degree of qualitative and quantitative agreement with a maximum error of 9.9%.Finally,the proposed methodology was utilized to perform a parametric analysis to explore the effects of various parameters,such as fault displacement,fault zone width,fault zone strength,the ratio of maximum fault displacement of the hanging wall to the footwall,and fault plane position,on the response of tunnels subjected to strike-slip fault dislocation.The findings indicate a progressive increase in the peak internal forces of the tunnel with the rise in fault displacement and fault zone strength.Conversely,an augmentation in fault zone width is found to contribute to a decrease in the peak internal forces.For example,for a fault zone width of 10 m,the peak values of bending moment,shear force,and axial force are approximately 46.9%,102.4%,and 28.7% higher,respectively,compared to those observed for a fault zone width of 50 m.Furthermore,the position of the peak internal forces is influenced by variations in the ratio of maximum fault displacement of the hanging wall to footwall and the fault plane location,while the peak values of shear force and axial force always align with the fault plane.The maximum peak internal forces are observed when the footwall exclusively bears the entirety of the fault displacement,corresponding to a ratio of 0:1.The peak values of bending moment,shear force,and axial force for the ratio of 0:1 amount to approximately 123.8%,148.6%,and 111.1% of those for the ratio of 0.5:0.5,respectively. 展开更多
关键词 strike-slip fault tunnel engineering semi-analytical solution fault zone width nonuniform fault displacement uncertain fault plane position
下载PDF
Model-Based Embedded Compiled Software Fault Positioning
2
作者 LIU Jinshuo CHEN Jian +2 位作者 ZHANG Weixin XU Xiangyang YAN Jingjing 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2017年第3期263-268,共6页
Software fault positioning is one of the most effective activities in program debugging. In this paper, we propose a model-based fault positioning method to detect the faults of embedded program without source code. T... Software fault positioning is one of the most effective activities in program debugging. In this paper, we propose a model-based fault positioning method to detect the faults of embedded program without source code. The system takes the machine code of embedded software as input and translates the code into high-level language C with the software reverse engineering program. Then, the static analysis on the high-level program is taken to obtain a control flow graph(CFG), which is denoted as a node-tree and each node is a basic block. According to the faults found by the field testing, we construct a fault model by extracting the features of the faulty code obtained by ranking the Ochiai coefficient of basic blocks. The model can be effectively used to locate the faults of the embedded program. Our method is evaluated on ST chips of the smart meter with the corresponding source code. The experiment shows that the proposed method has an effectiveness about 87% on the fault detection. 展开更多
关键词 code reverse engineering model-based test fault positioning
原文传递
Study on the distribution characteristics of faults and their control over petroliferous basins in the China seas and its adjacent areas 被引量:3
3
作者 Xin’gang Luo Wanyin Wang +5 位作者 Ying Chen Zhizhao Bai Dingding Wang Tao He Yimi Zhang Ruiyun Ma 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2023年第3期227-242,共16页
As one of the main controlling factors of oil and gas accumulation,faults are closely related to the distribution of oil and gas reservoirs.Studying how faults control petroliferous basins is particularly important.In... As one of the main controlling factors of oil and gas accumulation,faults are closely related to the distribution of oil and gas reservoirs.Studying how faults control petroliferous basins is particularly important.In this work,we investigated the plane positions of major faults in the China seas and its adjacent areas using the normalized vertical derivative of the total horizontal derivative(NVDR-THDR)of the Bouguer gravity anomaly,the fusion results of gravity and magnetic anomalies,and the residual Bouguer gravity anomaly.The apparent depths of major faults in the China seas and its adjacent areas were inverted using the Tilt-Euler method based on the Bouguer gravity anomaly.The results show that the strikes of the faults in the China seas and its adjacent areas are mainly NE and NW,followed by EW,and near-SN.Among them,the lengths of most ultra-crustal faults are in the range of 1000–3000 km,and their apparent depths lie between 10 km and 40 km.The lengths of crustal faults lie between 300 km and 1000 km,and their apparent depths are between 0 km and 20 km.According to the plane positions and apparent depths of the faults,we put forward the concept of fault influence factor for the first time.Based on this factor,the key areas for oil and gas exploration were found as follows:the east of South North China Basin in the intracontinental rift basins;the southeast region of East China Sea Shelf Basin,the Taixinan and Qiongdongnan basins in the continental margin rift basins;Zhongjiannan Basin in the strike-slip pull-apart basins;the Liyue,Beikang,and the Nanweixi basins in the rifted continental basins.This work provides valuable insights into oil and gas exploration,mineral resource exploration,and deep geological structure research in the China seas and its adjacent areas. 展开更多
关键词 China seas gravity and magnetic anomalies plane positions of faults apparent depths of faults oil and gas basins
下载PDF
Transmission cable fault detector based on waveform reconstruction
4
作者 吴剑锋 于忠洲 +2 位作者 李建清 王蕾 李小敏 《Journal of Southeast University(English Edition)》 EI CAS 2013年第1期48-51,共4页
In order to improve the accuracy of cable fault position location at a low cost and make the testing results intuitive, a cable fault detector based on wave form reconstruction is designed. In this detector, the cable... In order to improve the accuracy of cable fault position location at a low cost and make the testing results intuitive, a cable fault detector based on wave form reconstruction is designed. In this detector, the cable fault position is located based on the time-domain pulse reflection (TDR) principle. A pulse waveform is injected in the tested cable, and a high-speed comparator with changeable reference voltages is used to binarize the test pulse waveform to a binary sequence on a certain voltage. Through scanning the reference voltage in a full voltage range, multi-sequences are acquired to reconstruct the pulse waveform transmission in the cable, and then the pulse attenuation feature, electrical open circuit fault, electrical short circuit fault, and the fault position of the cable are diagnosed. Experimental results show that the designed cable fault detector can determine the fault type and its position of the cable being tested, and the testing results are intuitive. 展开更多
关键词 cable fault test waveform reconstruction fault position location time-domain pulse reflection
下载PDF
具有故障诊断功能的智能电气阀门定位器设计
5
作者 高磊 《集成电路应用》 2024年第6期105-107,共3页
阐述智能电气阀门定位器中的气动调节阀控制特点,它具备故障诊断功能。为此,研制的智能电气阀门定位器,通过增加微低功耗压力传感器、自诊断电路,以及多变量的融合算法,使其不但具有故障自诊断功能,而且具有阀门故障的诊断与预警功能。
关键词 压力传感器 低功耗 气动调节阀 阀门定位器 故障诊断与预警
下载PDF
探究调节阀智能定位器故障诊断 被引量:7
6
作者 赵斌 《电气传动自动化》 2019年第4期44-47,共4页
定位器是调节阀重要零部件,在化工仪表中有着不可忽视的作用与价值,其质量与生产装置运行状态有直接关联,也正因如此,相关单位一直极为注重调节阀智能定位故障诊断与消除操作。本文将以调节阀智能定位器及其特点介绍为例,对定位器故障... 定位器是调节阀重要零部件,在化工仪表中有着不可忽视的作用与价值,其质量与生产装置运行状态有直接关联,也正因如此,相关单位一直极为注重调节阀智能定位故障诊断与消除操作。本文将以调节阀智能定位器及其特点介绍为例,对定位器故障诊断方式展开深层次探究,并会针对仪器特点,提出几点维护管理建议,旨在改善调节阀智能定位器故障诊断现状,实现理想化定位器应用模式。 展开更多
关键词 定位器特点 故障诊断 阀门定位器 智能定位器 调节阀
下载PDF
浅析智能阀门定位器的特点 被引量:1
7
作者 杜乙雪 颜映晖 +1 位作者 王垚 苏玉硕 《仪表技术》 2008年第6期56-57,60,共3页
介绍阀门定位器的作用与原理,分析了传统阀门定位器存在的不足,并对智能阀门定位器的特点与优点、选型及故障处理进行了浅析。
关键词 智能阀门定位器 原理 选型 故障处理
下载PDF
Cognitions and questions regarding crustal deformation and location forecasts of strong earthquakes 被引量:1
8
作者 Wei Wenxin Jiang Zaisen Wu Yanqiang 《Geodesy and Geodynamics》 2015年第3期210-219,共10页
Using Global Positioning System(GPS) data to analyze the earthquake preparation characteristics of the Kunlun Ms8.1 and the Wenchuan Ms8.0 earthquakes, we review the main research developments of earthquake forecastin... Using Global Positioning System(GPS) data to analyze the earthquake preparation characteristics of the Kunlun Ms8.1 and the Wenchuan Ms8.0 earthquakes, we review the main research developments of earthquake forecasting and the mechanisms of earthquake preparation using crustal deformation data from recent periods, and discuss the similarities and differences in the scientific approaches adopted by the Chinese and foreign scholars. We then analyze the deformation characteristics of earthquake preparation, with respect to slip and dip-slip faults. Our results show that, in order to understand the relationship between crustal deformation and earthquake preparation, research focus should be expanded from fault-scale to larger scale regions. Furthermore, the dynamic deformation characteristics associated with earthquake preparation must be considered as a multiscale, spatial-temporal process, in order to obtain the necessary criteria for strong earthquake forecasts. 展开更多
关键词 Global positioning System(GPS) Active fault Focal
原文传递
阿特拉斯空压机导页开度异常波动的分析及处理 被引量:1
9
作者 李子源 《江西冶金》 2019年第3期38-41,共4页
文中简述了空压机在运行过程中导页开度异常波动的现象,通过对电位器及西门子智能定位器的工作原理分析,提炼出压缩机运行过程中开度异常波动的原因.结合生产需要,提出了不停机情况下解决问题的方法及措施,重点介绍了"在线对导页... 文中简述了空压机在运行过程中导页开度异常波动的现象,通过对电位器及西门子智能定位器的工作原理分析,提炼出压缩机运行过程中开度异常波动的原因.结合生产需要,提出了不停机情况下解决问题的方法及措施,重点介绍了"在线对导页的限位"、"在线脱开执行机构与阀体之间的连接件"、"在线更换新型分体式智能定位器"、"重新连接执行机构与阀体之间的连接件"、"取消导页的限位"的方法及过程,最终实现不停机处理导页故障. 展开更多
关键词 空压机 导页 定位器 故障分析
下载PDF
典型气动调节阀故障分析 被引量:1
10
作者 杨波 《电力安全技术》 2019年第10期52-55,共4页
气动调节阀控制管道流量,发生故障会危及机组运行安全。以三起典型气动调节阀故障为例,分析了气动调节阀气源失去、定位器进水、定位器反馈异常的故障的原因和处理方法,提出应对措施,以保障气动调节阀安全工作。
关键词 气动调节阀 定位器 故障开 非接触式分体式
下载PDF
超声波技术在电力系统故障诊断中的应用 被引量:4
11
作者 王松江 《油气田地面工程》 2020年第8期66-69,共4页
针对预防性试验不能发现电力设备集中缺陷问题,如电容器内部串并联部分小电容断线、瓷质开裂、绝缘部分受潮、绝缘内气泡、电缆故障点及路径查找,提出了应用超声波定位技术解决故障探测问题。超声波能形成很窄的波束,即具有指向性,利用... 针对预防性试验不能发现电力设备集中缺陷问题,如电容器内部串并联部分小电容断线、瓷质开裂、绝缘部分受潮、绝缘内气泡、电缆故障点及路径查找,提出了应用超声波定位技术解决故障探测问题。超声波能形成很窄的波束,即具有指向性,利用高频率超声波这一特性可以有效检测设备故障点。现场应用表明,该技术在发现均压电容器断线、电缆故障查找和电力设备绝缘诊断等方面效果显著,为进一步提高超声波技术在电力系统中的应用能力,提出了超声波局部放电检测及定位技术在开关柜中的应用研究方向。 展开更多
关键词 电力设备 故障探测 超声波 定位技术 超声波定位仪
下载PDF
DEH控制系统常见故障浅析 被引量:1
12
作者 薛艳玲 《山西电力》 2008年第1期25-26,28,共3页
针对DEH系统中的一些常见故障进行了分析,指出故障的现象及产生的原因并推荐了常规的处理方法,并以古交电厂DEH系统为例对故障进行了分析,列举了故障的处理方法及改进措施,对电厂运行检修人员正确使用和维护DEH系统有指导作用。
关键词 DEH 阀定位卡 位移传感器 故障现象 处理方法
下载PDF
气动调节阀保位系统在原油管道上的应用 被引量:3
13
作者 杨齐 高岩 刘亭 《自动化仪表》 CAS 北大核心 2013年第8期89-90,94,共3页
为了确保原油管道在设定的压力下安全运行,采用MOKVELD气动调节输油站场阀来自动调节输油站场管道进出站压力和管道压力波。原油管道输送工艺的特殊性要求调节阀出现故障时应处于保位状态。分析了现有调节阀控制原理和故障保位方案。由... 为了确保原油管道在设定的压力下安全运行,采用MOKVELD气动调节输油站场阀来自动调节输油站场管道进出站压力和管道压力波。原油管道输送工艺的特殊性要求调节阀出现故障时应处于保位状态。分析了现有调节阀控制原理和故障保位方案。由于调节阀配套的FISHER DVC6010电气定位器本身不具备故障保位功能,通过对调节阀进行增加电磁阀和信号保护模块的改造,实现了调节阀的故障保位功能。改造后的调节阀已成功应用于原油管道,确保了管道安全平稳运行。 展开更多
关键词 故障保位 原油管道 压力波 调节阀 定位器 电磁阀 安全模式
下载PDF
阀门定位器的调校及故障分析 被引量:1
14
作者 张文萍 王彬 张青松 《可编程控制器与工厂自动化(PLC FA)》 2010年第3期89-90,118,共3页
本文在介绍气动薄膜调节阀阀门定位器的基础上,重点讨论阀门定位器的常规校验方法和特殊校验问题。分析了常规校验方法的不足,运用自动控制原理对阀门定位器的常规校验方法进行了补充和完善,并对生产中经常出现的多种阀门定位器的常见... 本文在介绍气动薄膜调节阀阀门定位器的基础上,重点讨论阀门定位器的常规校验方法和特殊校验问题。分析了常规校验方法的不足,运用自动控制原理对阀门定位器的常规校验方法进行了补充和完善,并对生产中经常出现的多种阀门定位器的常见故障给出解决方案。 展开更多
关键词 阀门定位器 工作原理 调校 故障分析
下载PDF
SA/CL-1-EP型阀门定位器的在线更换与思考
15
作者 王国荣 《化工设计通讯》 CAS 2014年第4期38-40,共3页
针对PV1021A阀门定位器SA/CL-1-EP更换过程中出现的问题,改变分析问题的思路,使故障得以处理,并总结了处理过程的经验教训。
关键词 阀门定位器 故障 处理 教训
下载PDF
黄骅港双臂定位车液压系统原理及故障分析
16
作者 郗洪涛 周祥 李彦彬 《机械工程师》 2014年第9期163-165,共3页
针对神华黄骅港一期改造完成后的双臂定位车液压系统原理进行了分析,并对双臂定位车液压系统的常见故障提出了相应解决办法。
关键词 定位车 液压系统 故障分析
下载PDF
新型智能阀门定位器在炼油装置中的应用
17
作者 冯东石 《安全、健康和环境》 2016年第11期17-19,共3页
阐述一种智能阀门定位器原理和特性,同时对实际应用中所遇到的故障及原因进行了总结分析,为炼油装置的安全稳定生产和设备安全运转提供参考。
关键词 智能阀门定位器 调节阀 故障诊断 故障分析
下载PDF
国产智能定位器在600 MW直流锅炉燃烧系统的应用探究
18
作者 李坚 《电力系统装备》 2021年第6期83-84,共2页
靖海发电公司发电厂三次风门定位器阀芯经常堵塞,故障率高,进口STI定位器备件价格昂贵,设备维护成本高,影响锅炉的安全稳定运行。本文结合现场实际情况,提出了处理阀门控制故障率高的方法,利用国产TORLEO智能阀门定位器,改造升级原系统... 靖海发电公司发电厂三次风门定位器阀芯经常堵塞,故障率高,进口STI定位器备件价格昂贵,设备维护成本高,影响锅炉的安全稳定运行。本文结合现场实际情况,提出了处理阀门控制故障率高的方法,利用国产TORLEO智能阀门定位器,改造升级原系统,成效显著。 展开更多
关键词 定位器 三次风门 常见故障 应用
下载PDF
ABB智能阀门定位器在珞璜电厂技术改造中的应用
19
作者 黄湘 《自动化信息》 2012年第7期62-64,43,共4页
随着自动化技术的发展,系统对控制装置的要求也越来越高。针对ABB气动智能阀门定位器的特点,本文对珞璜电厂在阀门定位器改造过程中的问题和经验进行了介绍和交流,并分析了ABB智能阀门定位器的技术特点和控制原理,同时提出了改造的... 随着自动化技术的发展,系统对控制装置的要求也越来越高。针对ABB气动智能阀门定位器的特点,本文对珞璜电厂在阀门定位器改造过程中的问题和经验进行了介绍和交流,并分析了ABB智能阀门定位器的技术特点和控制原理,同时提出了改造的解决方案。 展开更多
关键词 智能阀门定位器 发电厂 改造 控制原理 故障分析
下载PDF
Inverse-time Backup Protection Based on Unified Characteristic Equation for Distribution Networks with High Proportion of Distributed Generations
20
作者 Nana Chang Guobing Song +2 位作者 Zhongxue Chang Yuping Zheng Xingang Yang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第1期202-212,共11页
The setting work of backup protection using steady-state current is tedious,and mismatches occasionally occur due to the increased proportion of distributed generations(DGs)connected to the power grid.Thus,there is a ... The setting work of backup protection using steady-state current is tedious,and mismatches occasionally occur due to the increased proportion of distributed generations(DGs)connected to the power grid.Thus,there is a practical need to study a backup protection technology that does not require step-by-step setting and can be adaptively coordinated.This paper proposes an action sequence adaptive to fault positions that uses only positive sequence fault component(PSFC)voltage.Considering the influence of DGs,the unified time dial setting can be obtained by selecting specific points.The protection performance is improved by using the adjacent upstream and downstream protections to meet the coordination time interval in the case of metallic faults at the near-and far-ends of the line.Finally,the expression and implementation scheme for inverse-time backup protection(ITBP)based on the unified characteristic equation is given.Simulation results show that this scheme can adapt to DG penetration scenarios and can realize the adaptive coordination of multi-level relays. 展开更多
关键词 Inverse-time backup protection(ITBP) distributed generation(DG) positive sequence fault component(PSFC)voltage unified characteristic equation adaptive coordination
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部