There are many reports about the research on near-fault velocity pulses, which focus on the generation of velocity pulse and simplify the velocity pulse so as to be used in the seismic design of structure, However few...There are many reports about the research on near-fault velocity pulses, which focus on the generation of velocity pulse and simplify the velocity pulse so as to be used in the seismic design of structure, However few researches have put emphasis on the characteristics of near-fault ground motions containing velocity pulses, especially the characteristics relevant with the design response spectrum prescribed by the code. Through collection of a large number of near-fault records containing velocity pulses, the response spectra and the characteristic periods of records containing no pulses are compared with those of records containing pulses. Response spectra of near-fault records are compared with standard spectra given by code; furthermore, the response spectra and the characteristic periods of each earthquake are compared with that given by code. The result shows that at long periods (longer than 1.5 s), the response spectrum of pulse-containing records is bigger than the response spectrum of no-pulse-containing records; when the characteristic period of near-fault records is calculated, the method that does not fix frequency is more reasonable because the T1 and T2 have a lagging tendency; regardless of the site Ⅰ and site Ⅱ, the characteristic period of pulse-containing records is over twice bigger than the characteristic period given by the code,展开更多
建立准确的静止无功发生器(static var generators,SVG)白盒电磁暂态仿真模型是分析电网电压稳定特性的前提。然而,由于SVG的控制器结构和参数保密,其建模大都基于典型控制结构和参数,模型的暂态输出特性与实际差异较大。针对上述问题,...建立准确的静止无功发生器(static var generators,SVG)白盒电磁暂态仿真模型是分析电网电压稳定特性的前提。然而,由于SVG的控制器结构和参数保密,其建模大都基于典型控制结构和参数,模型的暂态输出特性与实际差异较大。针对上述问题,提出了基于SVG厂家封装黑盒模型故障穿越(fault ride-through,FRT)演化特性的电磁暂态模型测辨方法。首先,分析了厂家黑盒模型的拓扑特征,通过多工况故障穿越响应测试,厘清了其故障穿越演化特性。然后,通过分析不同控制环节暂态切换过程对SVG故障穿越响应特性的影响和作用途径,提出了基于SVG故障穿越响应演化形态的控制器结构辨识方法。通过分析SVG不同控制环节参数对其故障穿越响应特性的分阶段作用原理,提出了基于故障穿越响应幅值的控制器参数分步辨识方法,形成了SVG的白盒化电磁暂态模型测辨方法体系。最后,将建立的不同型号白盒仿真模型与对应厂家黑盒模型进行了故障穿越响应特性对比分析,发现其误差远小于现行标准的允许误差,证明了提出方法的有效性和通用性。展开更多
基金National Natural Science Foundation of China (50278090).
文摘There are many reports about the research on near-fault velocity pulses, which focus on the generation of velocity pulse and simplify the velocity pulse so as to be used in the seismic design of structure, However few researches have put emphasis on the characteristics of near-fault ground motions containing velocity pulses, especially the characteristics relevant with the design response spectrum prescribed by the code. Through collection of a large number of near-fault records containing velocity pulses, the response spectra and the characteristic periods of records containing no pulses are compared with those of records containing pulses. Response spectra of near-fault records are compared with standard spectra given by code; furthermore, the response spectra and the characteristic periods of each earthquake are compared with that given by code. The result shows that at long periods (longer than 1.5 s), the response spectrum of pulse-containing records is bigger than the response spectrum of no-pulse-containing records; when the characteristic period of near-fault records is calculated, the method that does not fix frequency is more reasonable because the T1 and T2 have a lagging tendency; regardless of the site Ⅰ and site Ⅱ, the characteristic period of pulse-containing records is over twice bigger than the characteristic period given by the code,
文摘建立准确的静止无功发生器(static var generators,SVG)白盒电磁暂态仿真模型是分析电网电压稳定特性的前提。然而,由于SVG的控制器结构和参数保密,其建模大都基于典型控制结构和参数,模型的暂态输出特性与实际差异较大。针对上述问题,提出了基于SVG厂家封装黑盒模型故障穿越(fault ride-through,FRT)演化特性的电磁暂态模型测辨方法。首先,分析了厂家黑盒模型的拓扑特征,通过多工况故障穿越响应测试,厘清了其故障穿越演化特性。然后,通过分析不同控制环节暂态切换过程对SVG故障穿越响应特性的影响和作用途径,提出了基于SVG故障穿越响应演化形态的控制器结构辨识方法。通过分析SVG不同控制环节参数对其故障穿越响应特性的分阶段作用原理,提出了基于故障穿越响应幅值的控制器参数分步辨识方法,形成了SVG的白盒化电磁暂态模型测辨方法体系。最后,将建立的不同型号白盒仿真模型与对应厂家黑盒模型进行了故障穿越响应特性对比分析,发现其误差远小于现行标准的允许误差,证明了提出方法的有效性和通用性。