When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads t...When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved.展开更多
This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission chara...This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission characteristics of multi type current transformers and their influence factors, we study the dynamic model testing method of multi type current transformers for the bus, and design 3 kinds of testing schemes by making the equivalent model based on the field of P-level current transformer, TPY-level current transformer and electronic current transformer, and build the hybrid operation testing platform of multi type current transformers. Finally, we compare and analyze the transmission characteristics difference of multi type current transformers on the same branch and the characteristics difference of hybrid operation in two successive external faults, analyze the cause behind the differences, and put forward the corresponding improvement measures.展开更多
The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structu...The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper.展开更多
The emergence of distributed generators has changed the operational mode and fault characteristics of the distribu-tion network,in a way which can severely influence protection.This paper proposes a d-axis-based curre...The emergence of distributed generators has changed the operational mode and fault characteristics of the distribu-tion network,in a way which can severely influence protection.This paper proposes a d-axis-based current differential protection scheme.The d-axis current characteristics of inverter-interfaced distributed generators and synchronous generators are analyzed.The differential protection criterion using sampling values of the d-axis current component is then constructed.Compared to conventional phase-based current differential protection,the proposed protection reduces the number of required communication channels,and is suitable for distribution networks with inverter-interfaced distributed generators with complex fault characteristics.Finally,a 10 kV active distribution network model is built in the PSCAD platform and protection prototypes are developed in RTDS.Superior sensitivity and fast speed are verified by simulation and RTDS-based tests.展开更多
基金supported by the Natural Science Foundation of Sichuan Province(No.2022NSFSC0405).
文摘When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved.
文摘This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission characteristics of multi type current transformers and their influence factors, we study the dynamic model testing method of multi type current transformers for the bus, and design 3 kinds of testing schemes by making the equivalent model based on the field of P-level current transformer, TPY-level current transformer and electronic current transformer, and build the hybrid operation testing platform of multi type current transformers. Finally, we compare and analyze the transmission characteristics difference of multi type current transformers on the same branch and the characteristics difference of hybrid operation in two successive external faults, analyze the cause behind the differences, and put forward the corresponding improvement measures.
文摘The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper.
基金supported by China Southern Power Grid Technology Project.
文摘The emergence of distributed generators has changed the operational mode and fault characteristics of the distribu-tion network,in a way which can severely influence protection.This paper proposes a d-axis-based current differential protection scheme.The d-axis current characteristics of inverter-interfaced distributed generators and synchronous generators are analyzed.The differential protection criterion using sampling values of the d-axis current component is then constructed.Compared to conventional phase-based current differential protection,the proposed protection reduces the number of required communication channels,and is suitable for distribution networks with inverter-interfaced distributed generators with complex fault characteristics.Finally,a 10 kV active distribution network model is built in the PSCAD platform and protection prototypes are developed in RTDS.Superior sensitivity and fast speed are verified by simulation and RTDS-based tests.
文摘配电网经消弧线圈接地,发生单相接地故障时,存在着故障特征弱、不明显的特点,很难准确找到故障线路,近年来随着通信等相关技术的发展,差动保护成本不断降低,使得配网差动保护的实现成为可能。提出变分模态分解(variational mode decomposition,VMD)和Duffing振子系统相结合的选线方法,VMD获取暂态零序电流的高频分量,将线路两侧高频零序电流相位差加入Duffing系统中,通过分析线路两侧高频分量相位差和Duffing系统状态的联系,构造了基于动态时间弯曲(dynamic time warping,DTW)描述系统状态变化的区内区外故障判据,实现故障准确定位,最后通过数值仿真证明该选线方法在不同过渡电阻、有分布式电源等情况下能够快速、准确定位线路上发生单相接地故障的区段,验证了该方法的有效性。所提故障区段定位算法可以有效提取故障特征,提高了保护的可靠性和选线的准确率。