The winds will greatly weaken the cooling performance of indirect dry cooling system with twin towers.The exterior windbreakers are recommended to restrain the wind adverse effects in this paper.The macro heat exchang...The winds will greatly weaken the cooling performance of indirect dry cooling system with twin towers.The exterior windbreakers are recommended to restrain the wind adverse effects in this paper.The macro heat exchanger model was adopted to simulate the heat exchange between circulating water and ambient air.The performances of natural draft dry cooling system(NDDCS)with and without exterior windbreakers were numerically studied.The pressure,velocity and temperature distribution of cooling air in wind angles of 0°,45°and 90°was obtained and presented.The results show that in all wind directions,the performances for lateral sector of towers with windbreakers are significantly improved,but the low-pressure zone appears unexpectedly for the rear sectors,which reduces the air flow rate.The cooling performances of the twin towers with or without windbreakers decrease at first but then recover with the wind velocity increasing.Besides,the optimal flow and heat transfer performances appear in the wind angle of 0°.The cooling performances can be significantly improved in all three wind directions due to windbreaker configuration.展开更多
Vortex street flowmeter has been used in steady flow measurement for about three decades The benefits of this type of flowmeter include high accuracy,good linearty,wide measuring range,and excellent reliability Howeve...Vortex street flowmeter has been used in steady flow measurement for about three decades The benefits of this type of flowmeter include high accuracy,good linearty,wide measuring range,and excellent reliability However,in unsteady flow measurement,the pressure disturbance as well as the noise from the system or surrounding can reduce the signal to noise ratio of the flowmeter seriously Aimed to use vortex street flowmeters in unsteady flow measurement,the characteristics of the vortex shedding induced hydrodynamic vibration around the prism bluff body in a vortex street flowmeter are investigated numerically and by expriments The results show that the hydrodynamic vibrations with 180° phase shift occur at the axisymmetric points of the channel around the bluff body The most intense vibration occurs at the points on the lateral faces close to the base of the prism The results provide therefore a useful reference for developing an anti interference vortex flowmeter using the different ial sensing technique.展开更多
基金The financial supports for this research,from the National Basic Research Program of China(Grant No.2015CB251503)Central University Fundation of China(Grant No.JB2018130)。
文摘The winds will greatly weaken the cooling performance of indirect dry cooling system with twin towers.The exterior windbreakers are recommended to restrain the wind adverse effects in this paper.The macro heat exchanger model was adopted to simulate the heat exchange between circulating water and ambient air.The performances of natural draft dry cooling system(NDDCS)with and without exterior windbreakers were numerically studied.The pressure,velocity and temperature distribution of cooling air in wind angles of 0°,45°and 90°was obtained and presented.The results show that in all wind directions,the performances for lateral sector of towers with windbreakers are significantly improved,but the low-pressure zone appears unexpectedly for the rear sectors,which reduces the air flow rate.The cooling performances of the twin towers with or without windbreakers decrease at first but then recover with the wind velocity increasing.Besides,the optimal flow and heat transfer performances appear in the wind angle of 0°.The cooling performances can be significantly improved in all three wind directions due to windbreaker configuration.
基金This project is supported by National Natural Science Foundation of China(No.59835160).
文摘Vortex street flowmeter has been used in steady flow measurement for about three decades The benefits of this type of flowmeter include high accuracy,good linearty,wide measuring range,and excellent reliability However,in unsteady flow measurement,the pressure disturbance as well as the noise from the system or surrounding can reduce the signal to noise ratio of the flowmeter seriously Aimed to use vortex street flowmeters in unsteady flow measurement,the characteristics of the vortex shedding induced hydrodynamic vibration around the prism bluff body in a vortex street flowmeter are investigated numerically and by expriments The results show that the hydrodynamic vibrations with 180° phase shift occur at the axisymmetric points of the channel around the bluff body The most intense vibration occurs at the points on the lateral faces close to the base of the prism The results provide therefore a useful reference for developing an anti interference vortex flowmeter using the different ial sensing technique.