期刊文献+
共找到58篇文章
< 1 2 3 >
每页显示 20 50 100
Capacitive energy storage from single pore to porous electrode identified by frequency response analysis
1
作者 Weiheng Li Qiu-An Huang +7 位作者 Yu Li Yuxuan Bai Nan Wang Jia Wang Yongming Hu Yufeng Zhao Xifei Li Jiujun Zhang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第2期384-405,I0010,共23页
Rate capability,peak power,and energy density are of vital importance for the capacitive energy storage(CES)of electrochemical energy devices.The frequency response analysis(FRA)is regarded as an efficient tool in stu... Rate capability,peak power,and energy density are of vital importance for the capacitive energy storage(CES)of electrochemical energy devices.The frequency response analysis(FRA)is regarded as an efficient tool in studying the CES.In the present work,a bi-scale impedance transmission line model(TLM)is firstly developed for a single pore to a porous electrode.Not only the TLM of the single pore is reparameterized but also the particle packing compactness is defined in the bi-scale.Subsequently,the CES properties are identified by FRA,focused on rate capability vs.characteristic frequency,peak power vs.equivalent series resistance,and energy density vs.low frequency limiting capacitance for a single pore to a porous electrode.Based on these relationships,the CES properties are numerically simulated and theoretically predicted for a single pore to a porous electrode in terms of intra-particle pore length,intra-particle pore diameter,inter-particle pore diameter,electrolyte conductivity,interfacial capacitance&exponent factor,electrode thickness,electrode apparent surface area,and particle packing compactness.Finally,the experimental diagnosis of four supercapacitors(SCs)with different electrode thicknesses is conducted for validating the bi-scale TLM and gaining an insight into the CES properties for a porous electrode to a single pore.The calculating results suggest,to some extent,the inter-particle pore plays a more critical role than the intra-particle pore in the CES properties such as the rate capability and the peak power density for a single pore to a porous electrode.Hence,in order to design a better porous electrode,more attention should be given to the inter-particle pore. 展开更多
关键词 Porous electrode Intra-particle pore Inter-particle pore Capacitive energy storage Electrochemical impedance spectroscopy frequency response analysis
下载PDF
Tool Condition Monitoring Based on Nonlinear Output Frequency Response Functions and Multivariate Control Chart
2
作者 Yufei Gui Ziqiang Lang +1 位作者 Zepeng Liu Hatim Laalej 《Journal of Dynamics, Monitoring and Diagnostics》 2023年第4期243-251,共9页
Tool condition monitoring(TCM)is a key technology for intelligent manufacturing.The objective is to monitor the tool operation status and detect tool breakage so that the tool can be changed in time to avoid significa... Tool condition monitoring(TCM)is a key technology for intelligent manufacturing.The objective is to monitor the tool operation status and detect tool breakage so that the tool can be changed in time to avoid significant damage to workpieces and reduce manufacturing costs.Recently,an innovative TCM approach based on sensor data modelling and model frequency analysis has been proposed.Different from traditional signal feature-based monitoring,the data from sensors are utilized to build a dynamic process model.Then,the nonlinear output frequency response functions,a concept which extends the linear system frequency response function to the nonlinear case,over the frequency range of the tooth passing frequency of the machining process are extracted to reveal tool health conditions.In order to extend the novel sensor data modelling and model frequency analysis to unsupervised condition monitoring of cutting tools,in the present study,a multivariate control chart is proposed for TCM based on the frequency domain properties of machining processes derived from the innovative sensor data modelling and model frequency analysis.The feature dimension is reduced by principal component analysis first.Then the moving average strategy is exploited to generate monitoring variables and overcome the effects of noises.The milling experiments of titanium alloys are conducted to verify the effectiveness of the proposed approach in detecting excessive flank wear of solid carbide end mills.The results demonstrate the advantages of the new approach over conventional TCM techniques and its potential in industrial applications. 展开更多
关键词 intelligent manufacturing multivariate control chart Nonlinear Autoregressive with eXogenous Input modelling Nonlinear Output frequency response Functions tool condition monitoring
下载PDF
UWB Channel Modeling and Simulation with Continuous Frequency Response 被引量:4
3
作者 Kai Mao Qiuming Zhu +4 位作者 Xijuan Ye Ruirui Feng Fuqiao Duan Yang Miao Maozhong Song 《China Communications》 SCIE CSCD 2022年第11期88-98,共11页
Ultra-wideband(UWB)technology is a prospective technology for high-rate transmission and accurate localization in the future communication systems.State-of-art channel modeling approaches usually divide the UWB channe... Ultra-wideband(UWB)technology is a prospective technology for high-rate transmission and accurate localization in the future communication systems.State-of-art channel modeling approaches usually divide the UWB channel into several sub-band channels and model them independently.By considering frequency-dependent channel parameters,a novel analytical UWB channel model with continuous frequency response is proposed.The composite effect of all frequency components within the UWB channel on the channel impulse response(CIR)of delay domain is derived based on the continuous channel transfer function(CTF)of frequency domain.On this basis,a closed-form simulation model for UWB channels and geometry-based parameter calculation method are developed,which can guarantee the continuity of channel characteristics on the frequency domain and greatly reduce the simulation complexity.Finally,the proposed method is applied to generate UWB channel with 2 GHz bandwidth at sub-6GHz and millimeter wave(mmWave)bands,respectively.The channel measurements are also carried out to validate the proposed method.The simulated CIR and power gain are shown to be in good agreement with the measurement data.Moreover,the comparison results of power gain and Doppler power spectral density(DPSD)show that the proposed UWB channel model Received:Apr.23,2022 Revised:Jun.09,2022 Editor:Wei Fan achieves a good balance between the simulation accuracy and efficiency. 展开更多
关键词 ultra-wideband(UWB)channel continuous frequency response frequency-dependent channel parameters simulation model channel measurement
下载PDF
Generation-expansion planning with linearized primary frequency response constraints 被引量:4
4
作者 Zihan Wang Jianxiao Wang +1 位作者 Gengyin Li Ming Zhou 《Global Energy Interconnection》 2020年第4期346-354,共9页
As renewable energy resources increasingly penetrate the electric grid,the inertia capability of power systems has become a developmental bottleneck.Nevertheless,the importance of primary frequency response(PFR)when m... As renewable energy resources increasingly penetrate the electric grid,the inertia capability of power systems has become a developmental bottleneck.Nevertheless,the importance of primary frequency response(PFR)when making generation-expansion plans has been largely ignored.In this paper,we propose an optimal generation-expansion planning framework for wind and thermal power plants that takes PFR into account.The model is based on the frequency equivalent model.It includes investment,startup/shutdown,and typical operating costs for both thermal and renewable generators.The linearization constraints of PFR are derived theoretically.Case studies based on the modified IEEE 39-bus system demonstrate the efficiency and effectiveness of the proposed method.Compared with methods that ignore PFR,the method proposed in this paper can effectively reduce the cost of the entire planning and operation cycle,improving the accommodation rate of renewable energy. 展开更多
关键词 frequency equivalent model Generation expansion planning INERTIA Primary frequency response
下载PDF
Fast frequency response of inverter-based resources and its impact on system frequency characteristics 被引量:1
5
作者 Lining Su Xiaohui Qin +3 位作者 Shang Zhang Yantao Zhang Yilang Jiang Yi Han 《Global Energy Interconnection》 2020年第5期475-485,共11页
The inertia response and primary frequency regulation capability of synchronous grids are declining owing to the increasing penetration of inverter-based resources. The fast frequency response(FFR) of inverter-based r... The inertia response and primary frequency regulation capability of synchronous grids are declining owing to the increasing penetration of inverter-based resources. The fast frequency response(FFR) of inverter-based resources is an important mitigation option for maintaining grid security under the conditions of low inertia and insufficient primary frequency response capability. However, the understanding and technical characteristics of the FFR of inverter-based resources are still unclear. Aiming at solving the aforementioned problems, this paper proposes a definition for FFR based on the impact mechanism of FFR on system frequency. The performance requirements of FFR are clarified. Then, the effects of FFR on system frequency characteristics are further analyzed based on steady-state frequency deviation, the initial rate of change of frequency, and the maximum transient frequency deviation. Finally, the system requirements for FFR and its application effects are verified by simulating an actual bulk power grid, providing technical support for subsequent engineering application. 展开更多
关键词 Fast frequency response Rate of change of frequency frequency deviation ROCOF-based FFR Deviation-based FFR
下载PDF
Frequency response range of terahertz pulse coherent detection based on THz-induced time-resolved luminescence quenching
6
作者 张曼 杨振刚 +3 位作者 刘劲松 王可嘉 龚姣丽 汪盛烈 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期127-131,共5页
It has been proposed previously that the coherent detection of a terahertz(THz) pulse can be achieved based on the time-resolved luminescence quenching. In this paper, we investigate the frequency response range of th... It has been proposed previously that the coherent detection of a terahertz(THz) pulse can be achieved based on the time-resolved luminescence quenching. In this paper, we investigate the frequency response range of this novel detection technology by simulating the motion of carriers in gallium arsenide(GaAs) by the ensemble Monte Carlo method. At room temperature, for a direct-current(DC) voltage of 20 kV/cm applied to the semiconductor(GaAs) and sampling time o140 fs, the luminescence quenching phenomena induced by terahertz pulses with different center frequencies are studied The results show that the quenching efficiency is independent of the THz frequency when the frequency is in a range o0.1 THz–4 THz. However, when the frequency exceeds 4 THz, the efficiency decreases with the increase of frequency Therefore, the frequency response range is 0.1 THz–4 THz. Moreover, when the sampling time is changed to 100 fs the frequency response range is extended to be approximately 0.1 THz–5.6 THz. This study of the frequency-dependen characteristics of the luminescence response to the THz pulse can provide a theoretical basis for the exploration of THz detection technology. 展开更多
关键词 frequency response range terahertz-pulse coherent detection time-resolved luminescence quenching ensemble Monte Carlo method
原文传递
Pilot study on the Non-Invasive Detectability of Femoral Neck Fractures with Frequency Response Functions
7
作者 Wolfgang Witteveen Carina Wagner +2 位作者 Patrick Jachs Stefan Froschauer Harald Schoffl 《World Journal of Mechanics》 2014年第7期210-216,共7页
A suspicion of a femoral neck fracture is a frequently recurring situation, especially in nursing homes. For the clarification of such a suspicion normally imaging techniques are used. Such equipment is expensive and ... A suspicion of a femoral neck fracture is a frequently recurring situation, especially in nursing homes. For the clarification of such a suspicion normally imaging techniques are used. Such equipment is expensive and therefore is located in hospitals. In addition to the costs, a transport causes stress for the patient. This pilot study is devoted to the question whether the detection of a femoral neck fracture with vibration measurements is possible in principal. In such a case, the clarification could be done on-site by an ordinary person using much cheaper equipment. This would reduce the stress for the patient and save money. For this purpose vibration measurements on a dead body with intact, with partially fractured and with complete cut femoral neck have been performed. Two different methods for the vibration initiation have been investigated, the so called impact testing and the shaker testing. The frequency response function has been determined for all combinations on both sides of the body. It turned out that there is a clear difference in the frequency response functions of the fractured bone with respect to the intact bone when shaker testing is used. This indicates that the method could have the potential to be a cost-saving alternative to imaging techniques. However, in a next step a statistically reliable clinical survey on living persons needs to be done. 展开更多
关键词 BIOMECHANICS Vibrations frequency response Function FRF Femoral Neck Fracture
下载PDF
Dynamic frequency response characteristics of a compound regulative quasi-zero stiffness air spring system
8
作者 SHI Yan XU ShaoFeng +3 位作者 LI ZhiLong WANG YiXuan NIE YuLong SUN ZhiBo 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2023年第7期2013-2024,共12页
Quasi-zero stiffness(QZS) device is widely studied for their better performance in low-frequency and micro-vibration isolation due to the high-static and low-dynamic(HSLD) stiffness characteristics.The previous QZS is... Quasi-zero stiffness(QZS) device is widely studied for their better performance in low-frequency and micro-vibration isolation due to the high-static and low-dynamic(HSLD) stiffness characteristics.The previous QZS isolator with determined parameters is not suitable for variable isolated mass.In this study,a novel compound regulative quasi-zero stiffness air spring(CRQSAS)has been proposed and designed by introducing a bidirectional regulator for the horizontal air springs.The CRQSAS could change the quasi-zero region depending on the payload.To identify the parameters of the convoluted air spring(CAS) and novel rubber air spring(NRAS),the air spring testing system is established.The stiffness functions of air springs are obtained by the multi-parameter fitting method.According to the structure of the CRQSAS,the dynamic model of the system is analyzed and simplified by Taylor Expansion.The harmonic balance method(HBM) is applied to calculate the frequency response and absolute displacement transmissibility.An experimental prototype has been set up to verify the theoretical model and simulation.Compared with the single NRAS,CRQSAS performs better in low-frequency and micro-amplitude vibration.The research proves that CRQSAS is a passive device widely applied for improving isolation precision under low-frequency vibration. 展开更多
关键词 quasi-zero stiffness air springs frequency response low-frequency vibration
原文传递
Wind-farm and hydrogen-storage co-location system optimization for dynamic frequency response in the UK
9
作者 Fulin Fan Shanay Skellern +1 位作者 David Campos-Gaona John Nwobu 《Clean Energy》 EI CSCD 2023年第1期157-173,共17页
The continuous development of hydrogen-electrolyser and fuel-cell technologies not only reduces their investment and operating costs but also improves their technical performance to meet fast-acting requirements of el... The continuous development of hydrogen-electrolyser and fuel-cell technologies not only reduces their investment and operating costs but also improves their technical performance to meet fast-acting requirements of electrical grid balancing services such as frequency-response services.In order to project the feasibility of co-locating a hydrogen-storage system with a wind farm for the dynamic regulation frequency-response provision in Great Britain,this paper develops a modelling framework to coordinate the wind export and frequency responses to the main grid and manage the interaction of the electrolyser,compressor,storage tank and fuel cell within the hydrogen-storage system by respecting the market mechanisms and the balance and conversion of power and hydrogen flows.Then the revenue of frequency-response service provision and a variety of costs induced by the hydrogen-storage system are translated into the net profit of the co-location system,which is maximized by optimizing the capacities of hydrogen-storage-system components,hydrogen-storage levels that guide the hydrogen restoration via operational baselines and the power interchange between a wind-farm and hydrogen-storage system,as well as the capacities tendered for low-and high-frequency dynamic regulation services.The developed modelling framework is tested based on a particular 432-MW offshore wind farm in Great Britain combined with the techno-economics of electrolysers and fuel cells projected for 2030 and 2050 scenarios.The optimized system configuration and operation are compared between different operating scenarios and discussed alongside the prospect of applying hydrogen-storage systems for frequency-response provision. 展开更多
关键词 dynamic regulation frequency response hydrogen-storage system techno-economic optimization UK perspective wind farm
原文传递
Contingency Reserve Evaluation for Fast Frequency Response of Multiple Battery Energy Storage Systems in a Large-scale Power Grid
10
作者 Indira Alcaide-Godinez Feifei Bai +1 位作者 Tapan Kumar Saha Rizah Memisevic 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第3期873-883,共11页
Recently,the fast frequency response(FFR)service by large-scale battery energy storage systems(BESSs)has been successfully proved to arrest the frequency excursion during an unexpected power outage.However,adequate fr... Recently,the fast frequency response(FFR)service by large-scale battery energy storage systems(BESSs)has been successfully proved to arrest the frequency excursion during an unexpected power outage.However,adequate frequency response relies on proper evaluation of the contingency reserve of BESSs.The BESS FFR reserve is commonly managed under fixed contracts,ignoring various response characteristics of different BESSs and their coexisting interactions.This paper proposes a new methodology based on dynamic grid response and various BESS response characteristics to optimise the FFR reserves and prevent the frequency from breaching the under-frequency load shedding(UFLS)thresholds.The superiority of the proposed method is demonstrated to manage three large-scale BESSs operating simultaneously in an Australian power grid under high renewable penetration scenarios.Further,the proposed method can identify remaining battery power and energy reserve to be safely utilised for other grid services(e.g.,energy arbitrage).The results can provide valuable insights for integrating FFR into conventional ancillary services and techno-effective management of multiple BESSs. 展开更多
关键词 Fast frequency response(FFR) fast frequency contingency reserve multiple large-scale battery energy storage system(BESS) synthetic inertia requirement under-frequency load shedding(UFLS)
原文传递
A Selective‑Response Hypersensitive Bio‑Inspired Strain Sensor Enabled by Hysteresis Effect and Parallel Through‑Slits Structures
11
作者 Qun Wang Zhongwen Yao +8 位作者 Changchao Zhang Honglie Song Hanliang Ding Bo Li Shichao Niu Xinguan Huang Chuanhai Chen Zhiwu Han Luquan Ren 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第2期139-153,共15页
Flexible strain sensors are promising in sensing minuscule mechanical signals,and thereby widely used in various advanced fields.However,the effective integration of hypersensitivity and highly selective response into... Flexible strain sensors are promising in sensing minuscule mechanical signals,and thereby widely used in various advanced fields.However,the effective integration of hypersensitivity and highly selective response into one flexible strain sensor remains a huge challenge.Herein,inspired by the hysteresis strategy of the scorpion slit receptor,a bio-inspired flexible strain sensor(BFSS)with parallel through-slit arrays is designed and fabricated.Specifically,BFSS consists of conductive monolayer graphene and viscoelastic styrene–isoprene–styrene block copolymer.Under the synergistic effect of the bio-inspired slit structures and flexible viscoelastic materials,BFSS can achieve both hypersensitivity and highly selective frequency response.Remarkably,the BFSS exhibits a high gage factor of 657.36,and a precise identification of vibration frequencies at a resolution of 0.2 Hz through undergoing different morphological changes to high-frequency vibration and low-frequency vibration.Moreover,the BFSS possesses a wide frequency detection range(103 Hz)and stable durability(1000 cycles).It can sense and recognize vibration signals with different characteristics,including the frequency,amplitude,and waveform.This work,which turns the hysteresis effect into a"treasure,"can provide new design ideas for sensors for potential applications including human–computer interaction and health monitoring of mechanical equipment. 展开更多
关键词 Bio-inspired strain sensors Hysteresis effect HYPERSENSITIVITY Selective frequency response Health monitoring applications
下载PDF
Optimal generation mix for frequency response adequacy in future power system
12
作者 Vivek Prakash Kailash Chand Sharma Rohit Bhakar 《Energy and Built Environment》 2021年第3期243-250,共8页
Strict enforcement of government policies to integrate high generation share from renewable energy sources(RES)like wind and PV would create inevitable operational challenges for the utilities to deliver Frequency Res... Strict enforcement of government policies to integrate high generation share from renewable energy sources(RES)like wind and PV would create inevitable operational challenges for the utilities to deliver Frequency Response(FR)services.Uncertain RES generation characteristics would worsen the situation for SO,to detain initial frequency deviation following the largest generation outage.This necessitates investigation of optimal generator combination for securing PFR adequacy with simultaneous characterization of uncertainty.In this regard,this paper proposes a novel Modified Interval(MI)based optimal generation mix formulation for operation cost minimization and FR adequacy.RES uncertainty is characterised by forecasted upper and lower bound,while hourly ramp needs are based on the net load scenarios.Proposed model is assessed on one area IEEE reliability test system.Rate of change of frequency(ROCOF)and frequency deviation are considered as network security limits to obtain optimal generation mix.Results obtained provide,overall cost performance,PFR and optimal generation mix,without violating system security criteria.This model would certainly assist SO,to enhance system’s inertia and PFR adequacy at short-term system operations and could be extended for long-term planning framework. 展开更多
关键词 frequency response Generation mix Inertial response Net load Primary frequency response System security Unit commitment
下载PDF
A Comprehensive Power Flow Approach for Multi-terminal VSC-HVDC System Considering Cross-regional Primary Frequency Responses 被引量:10
13
作者 Yida Ye Ying Qiao +1 位作者 Le Xie Zongxiang Lu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第2期238-248,共11页
For the planning,operation and control of multiterminal voltage source converter(VSC)based high-voltage direct current(HVDC)(VSC-MTDC)systems,an accurate power flow formulation is a key starting point.Conventional pow... For the planning,operation and control of multiterminal voltage source converter(VSC)based high-voltage direct current(HVDC)(VSC-MTDC)systems,an accurate power flow formulation is a key starting point.Conventional power flow formulations assume the constant frequencies for all asynchronous AC systems.Therefore,a new feature about the complex coupling relations between AC frequencies,DC voltages and the exchanged power via VSC stations cannot be characterized if VSC-MTDC systems are required to provide cross-regional frequency responses.To address this issue,this paper proposes a comprehensive frequency-dependent power flow formulation.The proposed approach takes the frequencies of asynchronous AC systems as explicit variables,and investigates the novel bus models of the interlinking buses of VSC stations.The proposed approach accommodates different operation modes and frequency droop strategies of VSC stations,and considers the power losses of VSC stations.The effectiveness and generality of the developed approach are validated by a 6-terminal VSC-HVDC test system.The test system presents the characteristics of the coexistence of numerous VSC operation modes,the absence of slack buses in both AC and DC subsystems,and diversified grid configurations such as point-to-point integration of renewable energy sources and one AC system integrated with multiple VSC stations. 展开更多
关键词 Voltage source converter based high-voltage direct current(VSC-HVDC) multi-terminal VSC based HVDC(VSC-MTDC) cross-regional frequency response power flow formulation VSC operation mode
原文传递
Dynamic frequency response from electric vehicles in the Great Britain power system 被引量:8
14
作者 Jian MENG Yunfei MU +3 位作者 Jianzhong WU Hongjie JIA Qian DAI Xiaodan YU 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2015年第2期203-211,共9页
With the large penetration of renewable energy,fulfilling the balance between electricity demand and supply is a challenge to the modern power system.According to the UK government,the wind power penetration will reac... With the large penetration of renewable energy,fulfilling the balance between electricity demand and supply is a challenge to the modern power system.According to the UK government,the wind power penetration will reach 30%by the year 2020.The role of electric vehicles(EVs)contributing to frequency response was investigated.A dynamic frequency control strategy which considers the comfort level of vehicle owners was developed for EVs to regulate their power consumption according to the deviation of system frequency.A simulation model of a population of EVs equipped with such controlwas implemented inMatlab/Simulink platform.In this paper,a simplified Great Britain power system model is used to study the contribution of EVs to dynamic frequency control.The case study showed that using EVs as a demand response resource can greatly reduce the frequency deviations.And the rapid response from EVs can help reduce the operation cost of conventional generators. 展开更多
关键词 Electric vehicles(EVs) Dynamic frequency response Vehicle to grid(V2G) State of charge(SOC)
原文传递
Machine learning-based fast frequency response control for a VSC-HVDC system 被引量:3
15
作者 Kaiqi Sun Huangqing Xiao +1 位作者 Shengyuan Liu Yilu Liu 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第4期688-697,共10页
HVDC system can realize a very fast frequency response to the disturbed system under a contingency because its active power control is decoupled from the frequency deviation.However,most of existing HVDC frequency con... HVDC system can realize a very fast frequency response to the disturbed system under a contingency because its active power control is decoupled from the frequency deviation.However,most of existing HVDC frequency control strategies are coupled with system primary frequency control and secondary frequency control.Since the traditional system frequency control is dominated by the thermal generators,the advantage of the fast response of the HVDC system is not made fully used.The development of a frequency response estimation based on a machine learning algorithm provides another approach to improve the frequency response capability of the HVDC system.Different from other frequency deviation tracking strategies,a machine learning based HVDC frequency response control can directly increase the power flow of a HVDC system by estimation of the system generator or load lost.In this paper,a fast frequency response control using a HVDC system for a large power system disturbance based on the multivariate random forest regression(MRFR)algorithm is proposed.The simulation is carried out with an integrated power system model based on the North American interconnections.The simulation results indicate that the proposed MRFR based frequency response control can significantly improve the frequency low point during an event,while stabilizing the frequency in advance. 展开更多
关键词 frequency response control multivariate random forest regression VSC-HVDC system
原文传递
Dynamics Analysis of Active Variable Stiffness Vibration Isolator for Whole-Spacecraft Systems Based on Nonlinear Output Frequency Response Functions 被引量:1
16
作者 Kefan Xu Yewei Zhang +2 位作者 Yunpeng Zhu Jian Zang Liqun Chen 《Acta Mechanica Solida Sinica》 SCIE EI CSCD 2020年第6期731-743,共13页
In order to improve the harsh dynamic environment experienced by heavy rockets during different external excitations,this study presents a novel active variable stiffness vibration isolator(AVS-VI)used as the vibratio... In order to improve the harsh dynamic environment experienced by heavy rockets during different external excitations,this study presents a novel active variable stiffness vibration isolator(AVS-VI)used as the vibration isolation device to reduce excessive vibration of the whole-spacecraft isolation system.The AVS-VI is composed of horizontal stiffness spring,positive stiffness spring,parallelogram linkage mechanism,piezoelectric actuator,acceleration sensor,viscoelastic damping,and PID active controller.Based on the AVS-VI,the generalized vibration transmissibility determined by the nonlinear output frequency response functions and the energy absorption rate is applied to analyze the isolation performance of the whole-spacecraft system with AVS-VI.The AVS-VI can conduct adaptive vibration suppression with variable stiffness to the whole-spacecraft system,and the analysis results indicate that the AVS-VI is efTective in reducing the extravagant vibration of the whole-spacecraft system,where the vibration isolation is decreased up to above 65%under different acceleration excitations.Finally,different parameters of AVS-VI are considered to optimize the whole-spacecraft system based on the generalized vibration transmissibility and the energy absorption rate. 展开更多
关键词 Vibration isolation Active variable stiffness vibration isolator Nonlinear output frequency response functions(NOFRFs) TRANSMISSIBILITY
原文传递
Development approach of a programmable and open software package for power system frequency response calculation 被引量:1
17
作者 Yuzheng Xie Hengxu Zhang +1 位作者 Changgang Li Huadong Sun 《Protection and Control of Modern Power Systems》 2017年第1期189-198,共10页
Dynamic behaviour of frequency is crucial for power system operation and control.Several frequency response models have been proposed to reveal frequency dynamics from different aspects.A comprehensive software packag... Dynamic behaviour of frequency is crucial for power system operation and control.Several frequency response models have been proposed to reveal frequency dynamics from different aspects.A comprehensive software package incorporating major frequency response models is needed for analysis and control of power system frequency dynamics.In this paper,an approach for developing a programmable and open software package for frequency response studies is proposed.The framework of the package is extendable with reduced frequency response models.Essential models for frequency response study are included,e.g.,generator,load,and under-frequency load shedding(UFLS).The provided application program interfaces(APIs)enable simulation with high-level languages by calling dynamic link library and makes the package programmable.An advanced application module is developed for quantitative assessment of transient frequency deviation.APIs can also be used for model extension and secondary development.To demonstrate the usage of the package,several examples are illustrated to explain how to perform simulations with the package,and to perform advanced applications using scripting with the provided APIs. 展开更多
关键词 frequency response frequency control Software engineering Under-frequency load shedding Transient frequency deviation security Power systems
下载PDF
High-frequency supercapacitors with phosphorus-doped Ketjen black
18
作者 Qing Jin Mahima Khandelwal Woong Kim 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第7期464-474,I0010,共12页
Compact supercapacitors(SCs)have attracted attention for their great potential to replace bulky aluminum electrolytic capacitors(AECs)in alternating current(AC)line filtering applications.Herein,the fabrication of a h... Compact supercapacitors(SCs)have attracted attention for their great potential to replace bulky aluminum electrolytic capacitors(AECs)in alternating current(AC)line filtering applications.Herein,the fabrication of a high-frequency SC is reported using Ketjen black(KB)nanoparticles doped with phosphorus(P)to achieve a high areal capacitance of up to 2.26 mF cm^(-2)along with a high-rate capability,with a phase angle of-80.2°at 120 Hz.The high performance of the phosphorus-doped KB(designated PKB)SC with a 6 M KOH aqueous electrolyte is associated with its increased surface wettability and additional capacitive sites provided by the P-doping.Density functional theory(DFT)calculations further indicate that the P-doping enhances the interactions between the electrolyte ions and the carbon surface,thus leading to an improved electrochemical performance.These results suggest that the P-doped carbonbased SC could be highly favored in replacing conventional AECs in various high-frequency electronic devices. 展开更多
关键词 Phosphorus doping frequency response WETTABILITY SUPERCAPACITOR AC line filtering DFT calculation
下载PDF
Frequency response of loudspeakers by measuring theinduced e.m.f
19
作者 Hsu T S Poornima K A(Department of Physics. National Unwersity of Singapore Singapore 119260) 《Chinese Journal of Acoustics》 1998年第4期296-298,共3页
The technique of coupling two loudspeakers to obtain a signal proportional to the velocity of the cone is known. The sound at a distant point from a loudspeaker is related to the diaphragm displacement. Since the indu... The technique of coupling two loudspeakers to obtain a signal proportional to the velocity of the cone is known. The sound at a distant point from a loudspeaker is related to the diaphragm displacement. Since the induced e.m.f is proportional to the voice coil velocity,measurement of induced e.m.f enables us to obtain the displacement of the cone and hence we can plot the SPL curve for a loudspeaker. This method has some limitations in that it is particularly applicable only when one is interested in using the output of the second speaker used as a sensor in some further applications. 展开更多
关键词 frequency response of loudspeakers by measuring theinduced e.m.f
原文传递
Finite Element Analysis of the Frequency Response of a Microbubble Under Ultrasonic Field
20
作者 QIU Xiao-hui ZHOU Yan-hong +2 位作者 PENG You-lin ZHOU Li-li WANG Xiao-jian 《Chinese Journal of Biomedical Engineering(English Edition)》 2019年第1期41-46,共6页
The finite element numerical models of the microbubble with and without shell are built in our study.The calculation results indicate that the frequency response of the shell-microbubble is different from that of micr... The finite element numerical models of the microbubble with and without shell are built in our study.The calculation results indicate that the frequency response of the shell-microbubble is different from that of microbubble without shell.Furthermore,the frequency response of microbubble is closely related to the relevant parameters of the shell.The thickness and the Young's modulus willinfluence the frequency response.The increase of the thickness or the Young's modulus of the shell leads to the increase of the resonance frequency and the decrease of the oscillation amplitude of the microbubble. 展开更多
关键词 mircobubble frequency response finite element analysis
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部