期刊文献+
共找到5,186篇文章
< 1 2 250 >
每页显示 20 50 100
Furnace Temperature Curve Optimization Model Based on Differential Evolution Algorithm
1
作者 Yiming Cheng 《Journal of Electronic Research and Application》 2024年第4期64-80,共17页
When soldering electronic components onto circuit boards,the temperature curves of the reflow ovens across different zones and the conveyor belt speed significantly influence the product quality.This study focuses on ... When soldering electronic components onto circuit boards,the temperature curves of the reflow ovens across different zones and the conveyor belt speed significantly influence the product quality.This study focuses on optimizing the furnace temperature curve under varying settings of reflow oven zone temperatures and conveyor belt speeds.To address this,the research sequentially develops a heat transfer model for reflow soldering,an optimization model for reflow furnace conditions using the differential evolution algorithm,and an evaluation and decision model combining the differential evolution algorithm with the Technique for Order Preference by Similarity to Ideal Solution(TOPSIS)method.This approach aims to determine the optimal furnace temperature curve,zone temperatures of the reflow oven,and the conveyor belt speed. 展开更多
关键词 Furnace temperature curve difference equations differential evolution algorithms TOPSIS methods
下载PDF
In Tube Condensation:Changing the Pressure Drop into a Temperature Difference for a Wire-on-Tube Heat Exchanger
2
作者 Louay Abd Al-Azez Mahdi Mohammed A.Fayad Miqdam T.Chaichan 《Fluid Dynamics & Materials Processing》 EI 2023年第9期2201-2214,共14页
A theoretical study based on the Penalty factor(PF)method by Cavallini et al.is conducted to show that the pressure drop occurring in a wire-on-tube heat exchanger can be converted into a temperature difference for tw... A theoretical study based on the Penalty factor(PF)method by Cavallini et al.is conducted to show that the pressure drop occurring in a wire-on-tube heat exchanger can be converted into a temperature difference for two types of refrigerants R-134a and R-600a typically used for charging refrigerators and freezers.The following conditions are considered:stratified or stratified-wavyflow condensation occurring inside the smooth tube of a wire-on-tube condenser with diameter 3.25,4.83,and 6.299 mm,condensation temperatures 35℃,45℃,and 54.4℃ and cover refrigerant massflow rate spanning the interval from 1 to 7 kg/hr.The results show that the PF variation is not linear with vapor quality and attains a maximum when the vapor quality is 0.2 and 0.18 for the R-134a and R-600a refrigerants,respectively.The PF increases with the refrigerant massflow rate if the inner diameter and saturation temperature constant,and it decreases on increasing the inner diameter to 6.299 mm for constant refrigerant massflow rate and saturation temperature.The PF for R-600a is higher than that for R-134a due to the lower saturation pressure in thefirst case.Furthermore,a stratifiedflow produces higher PF in comparison to the annularflow due to the effect of the surface tension. 展开更多
关键词 CONDENSATION penalty factor pressure drop temperature difference TWO-PHASE wire condenser
下载PDF
Magnetohydrodynamic Conjugate Free Convective Heat Transfer Analysis of an Isothermal Horizontal Circular Cylinder with Temperature Dependent Viscosity
3
作者 NHM. A. Azim 《Journal of Applied Mathematics and Physics》 2024年第10期3384-3401,共18页
Heat transfers due to MHD-conjugate free convection from the isothermal horizontal circular cylinder while viscosity is a function of temperature is investigated. The governing equations of the flow and connected boun... Heat transfers due to MHD-conjugate free convection from the isothermal horizontal circular cylinder while viscosity is a function of temperature is investigated. The governing equations of the flow and connected boundary conditions are made dimensionless using a set of non-dimensional parameters. The governing equations are solved numerically using the finite difference method. Numerical results are obtained for various values of viscosity variation parameter, Prandtl number, magnetic parameter, and conjugate conduction parameter for the velocity and the temperature within the boundary layer as well as the skin friction coefficients and heat transfer rate along the surface. 展开更多
关键词 Conjugate Free Convection Horizontal Circular Cylinder Implicit Finite difference Method MHD temperature Dependent Viscosity
下载PDF
A rapid assessment of MWRI-RM/FY3G brightness temperature
4
作者 Wenying He Xinran Xia +5 位作者 Shengli Wu Peng Zhang Hongbin Chen Xiang'ao Xia Yuquan Zhou Miao Cai 《Atmospheric and Oceanic Science Letters》 CSCD 2024年第3期42-46,共5页
2023年4月发射的FY-3G上搭载17个频率的测雨微波成像仪(MWRI-RM),其业务定标的微波亮温(Tb)数据于2023年10月23日公开发布.本文比对了发布10天的MWRI-RM与全球降水测量(GPM)卫星上的微波成像仪(GMI)相匹配的Tb数据,并借助辐射传输模式... 2023年4月发射的FY-3G上搭载17个频率的测雨微波成像仪(MWRI-RM),其业务定标的微波亮温(Tb)数据于2023年10月23日公开发布.本文比对了发布10天的MWRI-RM与全球降水测量(GPM)卫星上的微波成像仪(GMI)相匹配的Tb数据,并借助辐射传输模式进行双差分(DD)交叉定标分析,旨在快速评估新一代MWRI-RM观测数据质量.观测比较表明,MWR1-RM与GMI测量的Tb一致性很好,大多通道的平均偏差(MBE)和均方根误差(RMSE)均小于1K.两种传感器由于观测角度略有不同在水面产生约0.5 K差异.DD分析也展示出MWRI-RM的大多数通道性能与GMI相当接近,尤其是首次启用的高频166 GHz和183 GHz. 展开更多
关键词 FY3G MWRI-RM GMI 亮度温度 双差分方法
下载PDF
On the relationship between convection intensity of South China Sea summer monsoon and air-sea temperature difference in the tropical oceans 被引量:12
5
作者 LINAilan LIANGJianyin +1 位作者 GUDejun WANGDongxiao 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2004年第2期267-278,共12页
The annual, interannual and inter-decadal variability of convection intensity of South China Sea (SCS) summer monsoon and air-sea temperature difference in the tropical ocean is analyzed, and their relationship is dis... The annual, interannual and inter-decadal variability of convection intensity of South China Sea (SCS) summer monsoon and air-sea temperature difference in the tropical ocean is analyzed, and their relationship is discussed using two data sets of 48-a SODA (simple ocean data assimilation) and NCEP/NCAR. Analyses show that in wintertime Indian Ocean (WIO), springtime central tropical Pacific (SCTP) and summertime South China Sea-West Pacific (SSCSWP), air-sea temperature difference is significantly associated with the convection intensity of South China Sea summer monsoon. Correlation of the inter-decadal time scale (above 10 a) is higher and more stable. There is inter-decadal variability of correlation in scales less than 10 a and it is related with the air-sea temperature difference itself for corresponding waters. The inter-decadal variability of the convection intensity during the South China Sea summer monsoon is closely related to the inter-decadal variability of the general circulation of the atmosphere. Since the late period of the 1970s, in the lower troposphere, the cross-equatorial flow from the Southern Hemisphere has intensified. At the upper troposphere layer, the South Asian high and cross-equatorial flow from the Northern Hemisphere has intensified at the same time. Then the monsoon cell has also strengthened and resulted in the reinforcing of the convection of South China Sea summer monsoon. 展开更多
关键词 tropical oceans air-sea temperature difference South China Sea summer monsoon convection Convec-tion intensity
下载PDF
Changes and spatial patterns of the differences between ground and air temperature over the Qinghai-Xizang Plateau 被引量:5
6
作者 ZHANG Wengang LI Shuxun +1 位作者 WU Tonghua PANG Qiangqiang 《Journal of Geographical Sciences》 SCIE CSCD 2007年第1期20-32,共13页
The difference between ground soil and air temperature (Ts-Ta) was studied by using the data of ground and air temperature of 99 stations over the Qinghai-Xizang (Tibet) Plateau from 1960 to 2000,and its spatial d... The difference between ground soil and air temperature (Ts-Ta) was studied by using the data of ground and air temperature of 99 stations over the Qinghai-Xizang (Tibet) Plateau from 1960 to 2000,and its spatial distribution and time changing tendency have been diagnosed by principal component analysis and power spectral analysis methods. The results show that the values of (Ts-Ta) are the maximum in June and the minimum in December. The first three loading eigenvectors, which reflect the main spatially anomalous structure of (Ts-Ta) over the Qinghai-Xizang Plateau, contain the contrary changing pattern between the northwestern and the southeastern regions, the pattern response of the sea level elevation and the geography, and the pattern response of the distribution of the permafrost. There are four patterns of time evolution including the patterns of monotonous increasing or decreasing trends, the basic stability pattern and the parabola pattern with the minimum value. (Ts-Ta) has a periodic variation about 2 years. According to the spatial distribution of the third loading eigenvectors of (Ts-Ta) over the Qinghai-Xizang Plateau in cold season, the permafrost response region and the seasonal frozen ground response region are identified. 展开更多
关键词 Qinghai-Xizang Plateau difference between ground and air temperature (Ts-Ta) principal component temperature subarea
下载PDF
Estimating extreme temperature differences in steel box girder using long-term measurement data 被引量:5
7
作者 丁幼亮 王高新 《Journal of Central South University》 SCIE EI CAS 2013年第9期2537-2545,共9页
The extreme temperature differences in fiat steel box girder of a cable-stayed bridge were studied.Firstly,by using the long-term measurement data collected by the structural health monitoring system installed on the ... The extreme temperature differences in fiat steel box girder of a cable-stayed bridge were studied.Firstly,by using the long-term measurement data collected by the structural health monitoring system installed on the Runyang Cable-stayed Bridge,the daily variations as well as seasonal ones of measured temperature differences in the box girder cross-section area were summarized.The probability distribution models of temperature differences were further established and the extreme temperature differences were estimated with a return period of 100 years.Finally,the temperature difference models in cross-section area were proposed for bridge thermal design.The results show that horizontal temperature differences in top plate and vertical temperature differences between top plate and bottom plate are considerable.All the positive and negative temperature differences can be described by the weighted sum of two Weibull distributions.The maximum positive and negative horizontal temperature differences in top plate are 10.30 ℃ and -13.80 ℃,respectively.And the maximum positive and negative vertical temperature differences between top plate and bottom plate are 17.30 ℃ and-3.70 ℃,respectively.For bridge thermal design,there are two vertical temperature difference models between top plate and bottom plate,and six horizontal temperature difference models in top plate. 展开更多
关键词 structural health monitoring cable-stayed bridge steel box girder temperature difference extreme value analysis
下载PDF
Uniformity principle of temperature difference field in heat transfer optimization 被引量:1
8
作者 Xue-Tao Cheng Xin-Gang Liang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第6期245-253,共9页
The uniformity principle of temperature difference field is very useful in heat exchanger analyses and optimizations.In this paper, we analyze some other heat transfer optimization problems in the thermal management s... The uniformity principle of temperature difference field is very useful in heat exchanger analyses and optimizations.In this paper, we analyze some other heat transfer optimization problems in the thermal management system of spacecrafts,including the cooling of thermal components, the one-stream series-wound heat exchanger network, the volume-to-point heat conduction problem, and the radiative heat transfer optimization problem, and have found that the uniformity principle of temperature difference field also holds. When the design objectives under the given constraints are achieved, the distributions of the temperature difference fields are uniform. The principle reflects the characteristic of the distribution of potential in the heat transfer optimization problems. It is also shown that the principle is consistent with the entransy theory. Therefore, although the principle is intuitive and phenomenological, the entransy theory can be the physical basis of the principle. 展开更多
关键词 heat TRANSFER optimization UNIFORMITY PRINCIPLE of temperature difference field EQUIPARTITION of potential entransy theory
原文传递
Solution precision of concrete temperature fields with finite difference method 被引量:1
9
作者 张宇鑫 黄达海 刘海成 《Journal of Shanghai University(English Edition)》 CAS 2008年第4期302-305,共4页
With the finite difference method to calculate the temperature distribution in mass concrete structures, the solution precision will increase with a smaller step size, at the cost of computational time. In view of the... With the finite difference method to calculate the temperature distribution in mass concrete structures, the solution precision will increase with a smaller step size, at the cost of computational time. In view of the basic characteristics of the finite difference method, a simple yet powerful improvement is introduced. By multiplying the adiabatic temperature function with a correction factor, the precision of the solution can be assured without an increase in the computation time. In addition, the correction rules for three types of commonly used concrete hydration formulas are investigated. 展开更多
关键词 concrete structure temperature field finite difference method HYDRATION
下载PDF
Enhanced temperature difference control of distillation columns based on the averaged absolute variation magnitude 被引量:1
10
作者 Yang Yuan Kejin Huang +3 位作者 Xing Qian Haisheng Chen Lijing Zang Liang Zhang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第1期266-278,共13页
Temperature difference control(TDC)schemes can clearly suppress the adverse influence of pressure variations on product quality control of various distillation columns(DCs)by employing temperature differences(TDs)betw... Temperature difference control(TDC)schemes can clearly suppress the adverse influence of pressure variations on product quality control of various distillation columns(DCs)by employing temperature differences(TDs)between the sensitive stage temperature(T_(S))and reference stage temperature(T_(R)),i.e.,T_(S)-T_(R),to infer the controlled product qualities.However,because the TDC scheme has failed to specially take the corresponding relationship between the TD employed in each control loop and the controlled product quality into account,it may suffer from relatively large steady-state errors in the controlled product qualities.To address this problem,an enhanced TDC(ETDC)scheme is proposed in the current article,in which an enhanced TD(ETD),i.e.,T_(S)-α×T_(R),is employed to replace the conventional TD for each control loop.While the locations of the sensitive and reference stages of the ETD are respectively determined according to sensitivity analysis and SVD analysis,the adjusted coefficientαis set to be the ratio between the averaged absolute variation magnitudes(AAVMs)of the T_(S)and T_(R)so that the relationship between the T_(S)and T_(R)can be appropriately coordinated.With reference to the operations of three different distillation systems,i.e.,one conventional DC distilling an ethanol(E)/butanol(B)binary mixture,one conventional DC distilling an E/propanol(P)/B ternary mixture,and one dividing-wall distillation column distilling an E/P/B ternary mixture,the performance of the ETDC scheme is assessed by compared with the conventional TDC scheme and the double TD control(DTDC)scheme.The dynamic simulation results show that the ETDC scheme is better than the conventional TDC scheme with reduced steady-state errors in the controlled product qualities and improved dynamic responses,and is comparable with the DTDC scheme despite the less temperature measurements are employed. 展开更多
关键词 Distillation column temperature difference AAVM temperature inferential control Process control
下载PDF
IMPROVEMENT OF REGIONAL PREDICTION OF SEA FOG ON GUANGDONG COASTLAND USING THE FACTOR OF TEMPERATURE DIFFERENCE IN THE NEAR-SURFACE LAYER 被引量:1
11
作者 黄辉军 黄健 +2 位作者 刘春霞 毛伟康 毕雪岩 《Journal of Tropical Meteorology》 SCIE 2016年第1期66-73,共8页
The relationship between the factor of temperature difference of the near-surface layer(T_(1000 hPa)-T_(2m))and sea fog is analyzed using the NCEP reanalysis with a horizontal resolution of l°xl°(2000 to 201... The relationship between the factor of temperature difference of the near-surface layer(T_(1000 hPa)-T_(2m))and sea fog is analyzed using the NCEP reanalysis with a horizontal resolution of l°xl°(2000 to 2011) and the station observations(2010 to 2011).The element is treated as the prediction variable factor in the GRAPES model and used to improve the regional prediction of sea fog on Guangdong coastland.(1) The relationship between this factor and the occurrence of sea fog is explicit:When the sea fog happens,the value of this factor is always large in some specific periods,and the negative value of this factor decreases significantly or turns positive,suggesting the enhancement of warm and moist advection of air flow near the surface,which favors the development of sea fog.(2) The transportation of warm and moist advection over Guangdong coastland is featured by some stages and the jumping among these states.It also gets stronger over time.Meanwhile,the northward propagation of warm and moist advection is quite consistent with the northward advancing of sea fog from south to north along the coastland of China.(3) The GRAPES model can well simulate and realize the factor of near-surface temperature difference.Besides,the accuracy of regional prediction of marine fog,the relevant threat score and Heidke skill score are all improved when the factor is involved. 展开更多
关键词 weather prediction regional prediction of marine fog Guangdong coastland GRAPES model factor of near-surface temperature difference
下载PDF
Effect of diurnal temperature difference on lipid accumulation and development in Calanus sinicus(Copepoda:Calanoida) 被引量:1
12
作者 周孔霖 孙松 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2017年第4期745-753,共9页
Calanus sinicus,the dominant copepod in the Yellow Sea,develops a large oil sac in late spring to prepare for over-summering in the Yellow Sea Cold Water Mass(YSCWM).The lipid accumulation mechanism for the initiation... Calanus sinicus,the dominant copepod in the Yellow Sea,develops a large oil sac in late spring to prepare for over-summering in the Yellow Sea Cold Water Mass(YSCWM).The lipid accumulation mechanism for the initiation of over-summering is unknown.Here,we cultured C3 copepodites at four constant temperatures(10,13,16,and 19℃) and at three temperature regimes that mimicked the temperature variations experienced during diurnal vertical migration(10-13℃,10-16℃,and 10-19℃) for 18 days to explore the effects of temperature differences on copepod development and lipid accumulation.C.sinicus stored more lipid at low than at high temperatures.A diurnal temperature difference(10-16℃ and 10-19℃)promoted greater lipid accumulation(1.9-2.1 times) than a constant temperature of either 16℃ or 19℃,by reducing the energy cost at colder temperatures and lengthening copepodite development.Thereafter,the lipid reserve supported gonad development after final molting.Only one male developed in these experiments.This highly female-skewed sex ratio may have been the result of the monotonous microalgae diet fed to the copepodites.This study provides the first evidence that diurnal temperature differences may promote lipid accumulation in C.sinicus,and provides a foundation for future investigations into the mechanisms involved in over-summering in the YSCWM. 展开更多
关键词 Calanus sinicus diurnal temperature difference lipid accumulation OVER-SUMMERING
原文传递
Single Neuron PID Control Based on Expert Experiences for Temperature Difference Control System of a Digester 被引量:3
13
作者 YaNan Huang AiJuan Zhang MuYi Hu 《Paper And Biomaterials》 2017年第1期52-58,共7页
Considering the temperature difference of displacement cooking characterized by severe non-linearity, large time delay, and real-time control, a cascade PID adaptive control strategy composed of a single neuron is pro... Considering the temperature difference of displacement cooking characterized by severe non-linearity, large time delay, and real-time control, a cascade PID adaptive control strategy composed of a single neuron is proposed to ensure cooking temperature uniformity. The control strategy introduces expert experiences to adjust the single neuron gain K, while a single neuron PID self-learning and adaptive ability, as well as cascade advantage can be combined to realize the real-time and fast temperature difference control. In the Simulink, the s-function of this control strategy is used to carry out a dynamic simulation experiment with temperature difference characteristics and verify the robustness and response to model mismatch. Compared to conventional temperature difference-flow PID cascade control and single neuron PID cascade control, this control strategy has better robustness and stronger adaptability. The results of real-time control on the THJSK-1 experiment platform indicate this control strategy is feasible. 展开更多
关键词 displacement cooking temperature difference expert experiences single neuron cascade PID
下载PDF
Effects of temperature and pressure differences on water seepage in breccia 被引量:2
14
作者 XU Longjun WANG Xingmin XIAN Xuefu 《Chinese Journal Of Geochemistry》 EI CAS 2012年第3期260-263,共4页
Effects of temperature and pressure differences on water seepage in breccia were investigated by using the physicochemical seepage instrument.The results show that the relationship of flow and pressure differences can... Effects of temperature and pressure differences on water seepage in breccia were investigated by using the physicochemical seepage instrument.The results show that the relationship of flow and pressure differences can be expressed by a linear equation,and the seepage coefficient is linearly correlated with temperature.The relation-ship between seepage flow and temperature could be described with the linear equation.The constant and tempera-ture seepage coefficient showed a linear relation with pressure.Binary quantitative equation for the seepage flow,temperature and pressure was obtained,and explained with experimental data and theoretical analysis. 展开更多
关键词 压力差异 角砾岩 温度 渗水 线性相关 渗透系数 方程表示 线性方程
下载PDF
Surface crack imaging based on delayed temperature difference at symmetric points by laser spot thermography 被引量:5
15
作者 WANG Xiaona WANG Xiaoning +1 位作者 HOU Dexin YE Shuliang 《Instrumentation》 2014年第2期30-37,共8页
Laser spot thermography is a novel technique for the detection of surface cracks with a laser to heat sample locally and with an IR camera to record the surface temperature distribution. Common methods to characterize... Laser spot thermography is a novel technique for the detection of surface cracks with a laser to heat sample locally and with an IR camera to record the surface temperature distribution. Common methods to characterize cracks are only suitable for the situation that the laser scanning path is vertical to the crack. But due to the randomness of cracks,when the scanning path is parallel to the crack,surface cracks cannot be detected by these methods. To tackle this problem,a method is presented which is suitable for the situation that the scanning path is parallel to crack. The main idea is to evaluate the crack-caused asymmetries of the surface temperature distribution. The effect of temperature gradient and the maximum scanning interval are analyzed by a 2D simulation. A new crack imaging technique is presented that is based on delayed temperature difference at symmetric points to characterize the crack in the thermal image. Compared well with those obtained by the spatial first derivative method,experimental results are shown to efficiently prove this method. 展开更多
关键词 Laser spot thermography Scanning path parallel to crack Delayed temperature difference at symmetric points Surface crack
原文传递
Strength Design Method for Tubing Hanger of Subsea Christmas Tree Against Big Temperature Difference
16
作者 罗晓兰 谷玉洪 +3 位作者 刘昌领 秦蕊 赵宏林 段梦兰 《China Ocean Engineering》 SCIE EI CSCD 2014年第5期659-670,共12页
The tubing hanger is an important component of the subsea Christmas tree, experiencing big temperature difference which will lead to very high thermal stresses. On the basis of API 17D/ISO 13628-4 and ASME VIII-1, and... The tubing hanger is an important component of the subsea Christmas tree, experiencing big temperature difference which will lead to very high thermal stresses. On the basis of API 17D/ISO 13628-4 and ASME VIII-1, and by comprehensively considering the erosion of oil and the gravity load of the tubing, a calculation model is established by regarding design pressure and thermal stress, and the method for designing the tubing hanger of the horizontal Christmas tree under big temperature difference condition is developed from the fourth strength theory. The proposed theory for strength design of the tubing hanger in big temperature difference is verified by numerical results from ABAQUS. 展开更多
关键词 horizontal Christmas tree tubing hanger big temperature difference comprehensive stress strength design
下载PDF
COMPARATIVE ANALYSIS OF VARIOUS DATA OF AIR-SEA TEMPERATURE DIFFERENCE AND ITS VARIATION ACROSS SOUTH CHINA SEA IN THE PAST 35 YEARS
17
作者 XU Feng XIA Tian-zhu +1 位作者 WANG Hui LIU Ke-xiu 《Journal of Tropical Meteorology》 SCIE 2017年第3期292-301,共10页
Using the International Comprehensive Ocean-Atmosphere Data Set(ICOADS) and ERA-Interim data, spatial distributions of air-sea temperature difference(ASTD) in the South China Sea(SCS) for the past 35 years are compare... Using the International Comprehensive Ocean-Atmosphere Data Set(ICOADS) and ERA-Interim data, spatial distributions of air-sea temperature difference(ASTD) in the South China Sea(SCS) for the past 35 years are compared,and variations of spatial and temporal distributions of ASTD in this region are addressed using empirical orthogonal function decomposition and wavelet analysis methods. The results indicate that both ICOADS and ERA-Interim data can reflect actual distribution characteristics of ASTD in the SCS, but values of ASTD from the ERA-Interim data are smaller than those of the ICOADS data in the same region. In addition, the ASTD characteristics from the ERA-Interim data are not obvious inshore. A seesaw-type, north-south distribution of ASTD is dominant in the SCS; i.e., a positive peak in the south is associated with a negative peak in the north in November, and a negative peak in the south is accompanied by a positive peak in the north during April and May. Interannual ASTD variations in summer or autumn are decreasing. There is a seesaw-type distribution of ASTD between Beibu Bay and most of the SCS in summer, and the center of large values is in the Nansha Islands area in autumn. The ASTD in the SCS has a strong quasi-3a oscillation period in all seasons, and a quasi-11 a period in winter and spring. The ASTD is positively correlated with the Nio3.4 index in summer and autumn but negatively correlated in spring and winter. 展开更多
关键词 marine meteorology air-sea temperature difference comparison of data empirical orthogonal function decomposition wavelet analysis ERA-INTERIM
下载PDF
Intracellular temperature measurement by a dual-thermocouple difference method
18
作者 Han Yuexia He Weinan +2 位作者 Yang Sheng Mao Wei Gu Ning 《Journal of Southeast University(English Edition)》 EI CAS 2021年第1期1-7,共7页
A dual thermocouple difference technique is developed to determine the accuracy and anti-interference ability in the process of intracellular temperature measurement.First,two micro-nano thermocouples(TC)and a high-pr... A dual thermocouple difference technique is developed to determine the accuracy and anti-interference ability in the process of intracellular temperature measurement.First,two micro-nano thermocouples(TC)and a high-precision signal acquisition module are used to measure the temperature difference between the cell and the culture medium(separated about 10μm from the cell).The cold junctions of two TCs are connected to eliminate the setting of the reference temperature and enhance the anti-interference ability.Then,a low-noise voltage amplifier and digital acquisition card are used to sample signals.In order to verify the feasibility of the dual thermocouple difference method,the temperature changes of U251 cells are detected.The calibration results of two TCs show that the Seebeck coefficient is about 5μV/℃,and the signal acquisition accuracy is 0.5μV in a low voltage range(0-15μV).With the dual thermocouple difference method,errors due to the cold junctions can be removed and the interference caused by environmental temperature fluctuation can be reduced.The phenomenon of cellular temperature increase proves that the dual thermocouple difference method can detect the tiny temperature change of a single cell.The method potentially is a highly powerful technique for studying local thermogenesis of cells and helps to explore the relationship between cellular thermogenesis and cellular processes. 展开更多
关键词 dual-thermocouple difference thermometry intracellular temperature NANOTECHNOLOGY
下载PDF
Concentration of Bio-Ethanol through Cellulose Ester Membranes during Temperature-Difference Controlled Evapomeation 被引量:1
19
作者 Tadashi Uragami 《Materials Sciences and Applications》 2011年第10期1499-1506,共8页
To evaluate the high-performance of membrane materials in the concentration of an aqueous solution of dilute bioethanol under temperature-difference controlled evapomeation (TDEV), asymmetric porous cellulose nitrate ... To evaluate the high-performance of membrane materials in the concentration of an aqueous solution of dilute bioethanol under temperature-difference controlled evapomeation (TDEV), asymmetric porous cellulose nitrate (CN) and cellulose acetate (CA) membranes were prepared by a phase inversion method. In the concentration of dilute ethanol under TDEV, these membranes showed a high permeation rate and high ethanol/water selectivity. In membranes with almost the similar pore size, the ethanol/water selectivity was considerably higher for the CN membrane than the corresponding CA membrane. This result suggested that the affinity between the membrane material and the permeant is an important factor in the separation selectivity. 展开更多
关键词 BIO-ETHANOL CONCENTRATION Membrane Cellulose ESTER temperature-difference CONTROLLED Evapomeation
下载PDF
Early application of percutaneous neuromuscular electric stimulation in interfering motor function of limbs and difference in temperature of axilla of patients with ischemic stroke
20
作者 Zhenhui Jiang Siyi Yin Na Bi Xiang He Fang Qu 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第2期188-189,共2页
BACKGROUND: Temperature of axilla could be affected due to motor dysfunction of limbs and neural changes of vessel after ischemic stroke. OBJECTIVE: To observe the effect of percutaneous neuromuscular electric stimu... BACKGROUND: Temperature of axilla could be affected due to motor dysfunction of limbs and neural changes of vessel after ischemic stroke. OBJECTIVE: To observe the effect of percutaneous neuromuscular electric stimulation (PNES) on difference in temperature of axilla and analyze the relationship between function of limbs and difference in temperature of axilla. DESIGN: Randomized grouping and controlled observation SETTING: Department of Neurology, General Hospital of Shenyang Military Area Command of Chinese PLA PARTICIPANTS: Sixty patients with ischemic stroke were selected from Neurological Department of General Hospital of Shenyang Military Area Command of Chinese PLA from January to June 2003. All cases were diagnosed with clinical diagnosis criteria of ischemic stroke established by the Fourth Chinese Classification of Cerebrovasular Disease and CT examination and received neuromuscular electric stimulation (NES). Patients were randomly divided into control group and treatment group with 30 in each group. METHODS: Control group: Patients received routinely neurological therapy. Treatment group: Except routine therapy, patients suffered from NES at 48 hours after hospitalization. NMT-91 NES equipment was used to stimulated injured limbs with low frequency once 30 minutes a day in total of 10 times a course, especially extensor muscle of upper limb and flexor muscle of lower limb. Prescription of hemiplegia was internally decided by equipment with the output frequency of 200 Hz. Intensity of electric output could cause muscle contraction. The therapy needed two or three courses. Temperature of bilateral axilla was measured every day to calculate the difference with the formula of (temperature of axilla on the injured side - temperature of axilla on the healthy side). Motor function of limbs was measured with FugI-Meyer Motor Assessment (FMA) during hospitalization and at 2 and 4 hours after hospitalization. Among 90 points, upper and lower limb function was 54, equilibrium function 10, sensory function 10, and motion of joint 16. The higher the scores were, the better the function was. Correlation of data was dealt with linear correlation analysis. MAIN OUTCOME MEASURES : Assessment and correlation between difference in temperature of axilla and motor function of injured limbs during hospitalization and at 2 and 4 weeks after hospitalization. RESULTS: All 60 patients with ischemic stroke were involved in the final analysis. ① Difference in temperature: Difference of 2 and 4 weeks after hospitalization was lower than that in control group and at just hospitalization [treatment group: (0.056±0.000), (0.024±0.003) ℃; control group: (0.250±0.001), (0.131 ±0.001)℃; hospitalization; (0.513±0.001) ℃, P 〈 0.05-0,01]. ② FMA scores: Scores of 2 and 4 weeks after hospitalization were higher than those in control group and at just hospitalization [treatment group; (43.50±15.09), (67.97 ±18.21) points; control group: (33.33 ±13.54), (40.87±19.34) points; hospitalization: (26.43 ±11.87) points, P 〈 0.05-0.01]. ③ Correlation: Difference in temperature of axilla was negative correlation with FMA scores (c=- -0.255 1, P 〈 0.05). CONCLUSION: ① PNES can accelerate recovery of limb function and decrease temperature of axilla of patients with ischemic stroke. ② The lower the difference in temperature is, the better the functional recovery is. 展开更多
关键词 lim Early application of percutaneous neuromuscular electric stimulation in interfering motor function of limbs and difference in temperature of axilla of patients with ischemic stroke
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部