The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick...The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick wall were calculated.In order to study the impact of light-weight external thermal insulation materials,a contrasting experiment was carried out between an external insulated room and an uninsulated room in August,2010,in Chongqing,China.The result shows that outside surface heat storage coefficient of the insulated wall is much less than that of the traditional wall.However,during sunny time,the surface temperature of external walls of the insulated room is obviously higher than that of the uninsulated room.In different orientations,due to different amounts of solar radiation and being irradiated in different time,the contrasting temperature difference(CTD) appears different regularity.In a word,using light-weight external thermal insulation materials has a negative impact on building surrounding thermal environment and people's health.Finally,some suggestions on how to eliminate the impact,such as improving the surface condition of the building envelop,and plating vertical greening,are put forward.展开更多
Two roof solar collectors (RSCs), conventional single pass RSC and new double pass RSC, were compared. The new roof solar collector, which is formed by integrating a double pass solar air collector with the roof of th...Two roof solar collectors (RSCs), conventional single pass RSC and new double pass RSC, were compared. The new roof solar collector, which is formed by integrating a double pass solar air collector with the roof of the building, can be operated more efficiently for space heating in winter, and for natural ventilation in other seasons. To evaluate the performances of the two RSCs for both space heating and natural ventilation, a single traditional Chinese style house, on which the two RSCs will be mounted, was developed. The efficiency of solar energy conversion for the new RSC is higher than that of the single pass one by 10% on average, and the ventilation rate contributed by natural ventilation for the new RSC can be improved to a great extent for most cases, indicating that the new RSC is superior to the single pass one from the viewpoint of both space heating and natural ventilation. The new RSC is more potential for improving indoor thermal environment and energy saving of buildings.展开更多
When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insu...When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insulation systems.Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges.Yet they may be successfully used and,in many instances,are recommended as a complement to the exterior insulation.This paper presents one of these cases.It is focused on the most successful applications of capillary active,dynamic interior thermal insulation.This happens when such insulation is integrated with heating,cooling and ventilation,air conditioning(HVAC)system.Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations,we propose a next generation,namely,a bio-fiber thermal insulation.When completing the review,this paper proposes a concept of a joint research project to be undertaken by partners from the US(where improvement of indoor climate in exposed coastal areas is needed),China(indoor climate in non-air conditioned concrete buildings is an issue),and Germany(where the bio-fiber technology has been developed).展开更多
基金Project(2011BAJ03B13) supported by the National Key Technologies R&D Program of China
文摘The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick wall were calculated.In order to study the impact of light-weight external thermal insulation materials,a contrasting experiment was carried out between an external insulated room and an uninsulated room in August,2010,in Chongqing,China.The result shows that outside surface heat storage coefficient of the insulated wall is much less than that of the traditional wall.However,during sunny time,the surface temperature of external walls of the insulated room is obviously higher than that of the uninsulated room.In different orientations,due to different amounts of solar radiation and being irradiated in different time,the contrasting temperature difference(CTD) appears different regularity.In a word,using light-weight external thermal insulation materials has a negative impact on building surrounding thermal environment and people's health.Finally,some suggestions on how to eliminate the impact,such as improving the surface condition of the building envelop,and plating vertical greening,are put forward.
基金Shanghai Com mission of Science andTechnology( No.0 3 DZ12 0 12 )
文摘Two roof solar collectors (RSCs), conventional single pass RSC and new double pass RSC, were compared. The new roof solar collector, which is formed by integrating a double pass solar air collector with the roof of the building, can be operated more efficiently for space heating in winter, and for natural ventilation in other seasons. To evaluate the performances of the two RSCs for both space heating and natural ventilation, a single traditional Chinese style house, on which the two RSCs will be mounted, was developed. The efficiency of solar energy conversion for the new RSC is higher than that of the single pass one by 10% on average, and the ventilation rate contributed by natural ventilation for the new RSC can be improved to a great extent for most cases, indicating that the new RSC is superior to the single pass one from the viewpoint of both space heating and natural ventilation. The new RSC is more potential for improving indoor thermal environment and energy saving of buildings.
文摘When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insulation systems.Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges.Yet they may be successfully used and,in many instances,are recommended as a complement to the exterior insulation.This paper presents one of these cases.It is focused on the most successful applications of capillary active,dynamic interior thermal insulation.This happens when such insulation is integrated with heating,cooling and ventilation,air conditioning(HVAC)system.Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations,we propose a next generation,namely,a bio-fiber thermal insulation.When completing the review,this paper proposes a concept of a joint research project to be undertaken by partners from the US(where improvement of indoor climate in exposed coastal areas is needed),China(indoor climate in non-air conditioned concrete buildings is an issue),and Germany(where the bio-fiber technology has been developed).