期刊文献+
共找到3,790篇文章
< 1 2 190 >
每页显示 20 50 100
Developing Operational Model for Heat Pumps as Space Heating and Domestic Hot Water Provider
1
作者 Rilwan Olaolu Oliyide Jose B. Hernandez 《Open Journal of Applied Sciences》 2024年第10期2880-2900,共21页
In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is o... In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is on the increase. The operation and working principle of heat pumps must be well understood in the investigations of their impacts on the grid and the grid assets, especially distribution transformers which could be overloaded due to higher peak load demand. This work develops an operational model of heat pumps as combined space heating and domestic hot water provider implemented in MATLAB. The developed operational model of heat pumps is adaptable and repeatable for different input parameters. The developed model is used to generate daily average demand profiles of heat pumps for a typical winter weekday and a typical summer weekday. The generated demand profiles of heat pumps by the developed model compared well with the demand profiles of heat pumps generated from actual field projects which are usually expensive and time-tasking. 展开更多
关键词 heat pumps Greenhouse Gases Space heating Domestic Hot water TRANSFORMER MATLAB
下载PDF
Development and Experimental Study of Air Source Heat Pump Water Heater 被引量:2
2
作者 李海峰 蔡正云 《Meteorological and Environmental Research》 CAS 2010年第2期100-102,共3页
The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The resul... The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The results showed that air source heat pump water heater was superior to conventional system.Under the operation of cooling and heating,heat pump comprehensive utilization equipment could improve heating performance,reduce energy consumption,and recycle condensing heat to provide hot water. 展开更多
关键词 Air source heat pump water heater China
下载PDF
Experimental study on characteristics of transcritical heat pump water heater using refrigerant HFC125
3
作者 王方 连之伟 +1 位作者 范晓伟 王凤坤 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期182-186,共5页
To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is car... To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average. 展开更多
关键词 HFC125 transcritical cycle heat pump water heater coefficient of performance(COP)
下载PDF
Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens 被引量:4
4
作者 LIU Zhong-bing,ZHANG Ling,YANG Zhang,XU Ming,HAN Tian-he(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期131-135,共5页
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff... A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient. 展开更多
关键词 THERMOELECTRIC heat pump KITCHENS EXHAUST water heater COEFFICIENT of performance
下载PDF
Numerical and Experimental Study on Dynamic Performance of Heat Pump Water Heater with Electronic Expansion Valve
5
作者 Liang Zhang Xianmin Guo Weiguo Li Weihua Wang 《Journal of Energy and Power Engineering》 2012年第10期1582-1588,共7页
A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capac... A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capacity and COP (coefficient of performance) of the HPWH unit under different EXV openings were measured. The effects of the EXV opening on the performance of the HPWH unit were analyzed. Meanwhile, the dynamic performance of the HPWH with EXV was simulated and the results were compared with the experimental one. The experimental results indicate that during heating process, the COP increases firstly and then decreases for a fixed EXV opening, which is in good agreement with the numerical result. For different EXV openings, the COP and heating capacity of the system using larger EXV opening are superior to those using the smaller one in the initial heating stage. While in the late stage, the performance of system using smaller EXV opening is better. It is found that the system performance is improved significantly by changing the EXV opening in the different heating period and the average COP of the HPWH system is increased by 7.6%. 展开更多
关键词 heat pump water heater electronic expansion valve experimental investigation simulation.
下载PDF
Experimental assessment of two-phase bubble pump for solar water heating 被引量:5
6
作者 CHUNG Han-shik WOO Ju-sik +2 位作者 SHIN Yong-han KIM Jun-hyo JEONG Hyo-min 《Journal of Central South University》 SCIE EI CAS 2012年第6期1590-1599,共10页
The research goal is to develop a new solar water heater system(SWHS) that uses a solar bubble pump instead of an electric pump.The pump is powered by the steam produced from an evacuated tube collector.Therefore,heat... The research goal is to develop a new solar water heater system(SWHS) that uses a solar bubble pump instead of an electric pump.The pump is powered by the steam produced from an evacuated tube collector.Therefore,heat could be transferred downward from the collector to a hot water storage tank.The designed system consists of two sets of heat-pipe evacuated tube collectors,a solar bubble pump installed at an upper level and a water storage tank with a heat exchanger at a lower level.Discharge heads of 1 and 5 m were tested.The bubble pump could operate at the collector temperature of about 90-100 ℃ and vapor gage pressure of 80-90 kPa.It is found that water circulation within the SWHS depends on the incident solar intensity and system discharge head.Experimental investigations are conducted to obtain the system thermal efficiencies from the hourly,daily and long-term performance tests.The thermal performance of the proposed system is compared with conventional solar water heaters.The results show that the proposed system achieves system characteristic efficiency of 10% higher than that of the conventional systems using electric pump if taking the consumption of electric power into account.And the former is a zero carbon system. 展开更多
关键词 two-phase bubble pump solar water heater system (SWHS) zero carbon
下载PDF
Thermo-Economic Performance of Geothermal Driven High-Temperature Flash Tank Vapor Injection Heat Pump System:A Comparison Study
7
作者 Huashan Li Xiaoshuang Zhao +2 位作者 Sihao Huang Lingbao Wang Jiongcong Chen 《Energy Engineering》 EI 2023年第8期1817-1835,共19页
Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is... Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price. 展开更多
关键词 Geothermal water high-temperature heat pump flash tank vapor injection thermo-economic performance
下载PDF
Performance and Optimization of Air Source Heat Pump Water Heater with Cyclic Heating
8
作者 李凡 陆高锋 +3 位作者 丁云霄 郑春元 李斌 翟晓强 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第2期179-187,共9页
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of... A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard. 展开更多
关键词 air source heat pump water heater(ASHPWH) cyclic heating MICROCHANNEL CONDENSER
原文传递
Performance enhancement of water bath heater at natural gas city gate station using twisted tubes
9
作者 P.Soleimani M.Khoshvaght-Aliabadi +1 位作者 H.Rashidi H.Bahmanpour 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2020年第1期165-179,共15页
Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). B... Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). Before the pressure reduction process, the temperature of natural gas is increased usually by using a water bath heater,which burns natural gas as fuel, to protect against freezing of natural gas. These types of heat exchangers have a low efficiency and consume a lot of fuel to generate the required heat. In the current study, the twisted configuration of the heating coil is proposed and investigated to enhance the heat transfer through a water bath heater with a nominal capacity of 1000 m^3·h^-1. Firstly, the implementation procedure is validated with data collected from the CGS of Qaleh-Jiq(located in Golestan province of Iran). A very good agreement is achieved between the obtained results and the real data. Then, three different twist ratios are considered to examine the twisting effects. The proposed technique is evaluated in the terms of velocity, temperature, and pressure variations, and the results are compared with the conventional case, i.e. straight configuration. It is found that both the heat transfer rate and the pressure drop augment as the twist ratio is raised. Finally, it is concluded that the twisted tubes can reduce the length of the gas coil by about 12.5% for the model with low twist ratio, 18.75% for the model with medium twist ratio, and 25% for the model with high twist ratio as compared to the straight configuration. 展开更多
关键词 Natural gas city GATE STATION water BATH heater heat TRANSFER enhancement TWISTED tube
下载PDF
Study on corrosion behavior of heat exchanger in water source heat pump
10
作者 刘作华 龙洋 +2 位作者 李百战 丁勇 周小霞 《化工进展》 EI CAS CSCD 北大核心 2010年第S1期695-698,共4页
Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.T... Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value. 展开更多
关键词 water source heat pump water quality RIVER water corrosion
下载PDF
Situation of China's solar water heater industry,related national standards,testing and the Golden Sun certification program
11
作者 严军 H.Drück H.Müller-Steinhagen 《Journal of Chongqing University》 CAS 2008年第2期107-112,共6页
China is the largest solar water heater producer and market in the world.Despite the fast growth and an installed capacity that accounts for the majority of the global gross,China's per capita solar hot water capa... China is the largest solar water heater producer and market in the world.Despite the fast growth and an installed capacity that accounts for the majority of the global gross,China's per capita solar hot water capacity is still very low,implying a huge margin of market potential;and the recognition of the industry in the global market is handicapped by the scattered scale of production and inconsistent product quality.To ensure continued growth of China's solar water heating(SWH) industry,Chinese Government has established a series of national SWH standards,three national testing centers,and a certification program to lay the foundation for the development of the Golden Sun product labeling system.China General Certification Center(CGC) developed the Golden Sun product certification and labeling system on a pass/fail basis evaluating with established criteria.The system was designed to help manufacturers acclimate to explicit consistent requirements and to identify and fix the deficiencies in the design and execution of the program itself.Timely revision and integration of the national standards are recommended to accommodate the test procedures and requirements to new technologies and the evolving SWH market.Strict implementation of the Golden Sun certification and labeling system are suggested to avail improving the quality control and forging internationally reputable brands of Chinese solar water heating products. 展开更多
关键词 solar water heaters solar heating renewable energy resources national standards Golden Sun certification program
下载PDF
Refrigerator Coupling to a Water-Heater and Heating Floor to Save Energy and to Reduce Carbon Emissions
12
作者 Romdhane Ben Slama 《Computational Water, Energy, and Environmental Engineering》 2013年第1期21-29,共9页
With an aim of rationing use of energy, energy safety, and to reduce carbon emission, our interest was geared towards the refrigerators and all the refrigerating machines. Indeed the heat yielded by the exchanger cond... With an aim of rationing use of energy, energy safety, and to reduce carbon emission, our interest was geared towards the refrigerators and all the refrigerating machines. Indeed the heat yielded by the exchanger condenser can be developed for the water heating, floors heating etc. After an encouraging theoretical study, two prototypes were produced in order to validate the theoretical results. A first refrigerator was coupled with a water-heater and another with a heating floor. The water temperature reached, in one day, is of 60℃;which makes it possible to predict better results with a continuously used refrigerator. In the same way for the heating floor coupled with the second refrigerator, the temperature reached high values because the surface is reduced;however for the heating floors the standard fixes the temperature between 28℃ and 30℃. 展开更多
关键词 REFRIGERATOR RECUPERATOR heatING water heatING Floor heat pump
下载PDF
he Design of Efficient Heat Transfer Based on Flat Plate Solar Water Heater
13
作者 Ma Juan-juan 《International Journal of Technology Management》 2013年第4期114-116,共3页
This is an improved design based on the existing plate type solar water heaters. It aims at making full use of solar energy. To fully absorb radiation, it absorbs coating selectively by adopting the magnetron sputteri... This is an improved design based on the existing plate type solar water heaters. It aims at making full use of solar energy. To fully absorb radiation, it absorbs coating selectively by adopting the magnetron sputtering technology AL-N/AL. this design conduct heat through aluminum material which can reduce the cost meanwhile conduct heat effectively. To ensure the quality of the water at the same time improve the utilization rate of solar energy, this design use phase change for second heat exchange. Take Shanghai for example, where this design and heat transfer model are applied, the average efficiency of water heaters can achieve 68%, which has proven the feasibility of the design. In a word, this design can achieve the goal of energy conservation and emissions reduction and has broad market prospects. 展开更多
关键词 Plate type solar water heater The secondary heat transfer Phase transition RF Magnetron Sputtering
下载PDF
Development of Instantaneous Hot Water Dispenser Based on Water Source Heat Pump
14
作者 Satoshi Yoshida Ryozo Ooka +1 位作者 Toshiyuki Hino Kazuo Kodama 《Journal of Energy and Power Engineering》 2014年第10期1703-1711,共9页
Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi... Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi-use heat pump) to achieve higher efficiency than traditional systems. The MMHP system connects multiple heat sources such as solar heat, the ground, and air and multiple heat uses such as cooling, heating, and a hot water dispenser with a water loop. Each type of heat use side can utilize heat efficiently. However, there is a distinct lack of highly efficient hot water dispensers available. Therefore, we developed the IHWD WS (instantaneous hot water dispenser based on a water source) heat pump. In this study, we developed a prototype of the IHWD WS heat pump. The coefficient of performance of the IHWD WS heat pump was 5.2-8.5 throughout a year. When it is improved, COP (coefficient of performance) is expected to be 9.3-9.9. 展开更多
关键词 heat pumps hot water EFFICIENCY COP ground source.
下载PDF
Performance investigation of solar thermal collector with auxiliary heater for space heating 被引量:3
15
作者 Hassan BIGLARIAN Mohammad Mazidi SHARFABADI +1 位作者 Mansour ALIZADEH Hossein GHARAEI 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第11期3466-3476,共11页
In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar... In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar water heater with a flat plate collector combined with an auxiliary electrical heater supplies the heating demand of the house.The proposed system was modeled and analyzed using TRNSYS software.In this regard,the TRNBuild module was employed for the building load calculation.The model has been simulated for one year of operation.The effects of the solar collector’s surface area and storage volume were assessed.The results show that for a solar collector with a 15 m^(2) surface area,the solar fraction is 0.29 in January,during which the solar radiation is the lowest.Using solar collectors of10 m^(2) and 5 m^(2) surface areas,the solar fraction falls to 0.23 and 0.14,respectively in January.Besides,two cases of 150 L and 300 L storage tanks are taken into account.Eventually,it is found that using a 15 m^(2) solar collector and a 150 L storage tank can appropriately provide the building’ s heating demand taking the thermal performance and economic aspects into consideration. 展开更多
关键词 space heating solar water heater THERMOSIPHON solar collector TRNSYS software
下载PDF
Thermodynamic Simulation of CCP in Air-Cooled Heat Pump Unit with HFCs and CO<sub>2</sub>Trans-Critical 被引量:2
16
作者 Feihu Chen Shuguang Liao Guangcai Gong 《Journal of Power and Energy Engineering》 2018年第9期141-164,共24页
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ... The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2. 展开更多
关键词 Air-Cooled heat pump Unit Compound Condensation Process (CCP) Exergy Analysis Method Sanitary Hot water MATLAB/SIMULINK Software Fluorine SUBSTITUTE REFRIGERANT R407C/R410A Natural REFRIGERANT CO2
下载PDF
The Preliminary Research of Sea Water District Heating and Cooling for Tallinn Coastal Area
17
作者 Allan Hani Teet-Andrus Koiv 《Smart Grid and Renewable Energy》 2012年第3期246-252,共7页
This paper describes possibilities to utilize sea water for district heating and cooling purposes in Tallinn costal area. The sea water temperature profiles and suitability of heating and cooling generation are studie... This paper describes possibilities to utilize sea water for district heating and cooling purposes in Tallinn costal area. The sea water temperature profiles and suitability of heating and cooling generation are studied for continental climatic conditions. The district network study bases on 21 buildings located near to the Gulf of Finland. Industrial reversible heat pump technology is selected to cover heating and cooling loads for the new buildings. Combination of existing district heating and heat pump technology is considered for existing buildings. The results show possibilities, threats and need for further research of the sea water based heat pump district network implementation. 展开更多
关键词 DISTRICT heatING COOLING SEA water heat pump RENEWABLE Energy Office Building
下载PDF
光伏光热联合双源热泵系统运行模式研究(1):最佳切换模式验证 被引量:2
18
作者 曲明璐 刘锡荣 +1 位作者 王海洋 张斌 《暖通空调》 2024年第8期67-72,80,共7页
讨论了光伏光热联合双源热泵系统制热运行的最佳切换模式。利用TRNSYS软件建立了仿真模型,对双源(水源、空气源)热泵系统性能系数(COP_(s))进行了计算,提出以某时刻空气源热泵模式或水源热泵模式运行COP_(s)较大者优先运行作为COP_(s)... 讨论了光伏光热联合双源热泵系统制热运行的最佳切换模式。利用TRNSYS软件建立了仿真模型,对双源(水源、空气源)热泵系统性能系数(COP_(s))进行了计算,提出以某时刻空气源热泵模式或水源热泵模式运行COP_(s)较大者优先运行作为COP_(s)切换模式。通过前期实验结果验证了模拟结果的正确性,并与常规的集热水箱温度切换模式进行了对比实验,验证了COP_(s)切换模式的有效性。结果表明,该实验系统以COP_(s)最佳切换模式运行时发电量和发电效率较集热水箱温度切换模式分别提高了5.35%和1.73%,耗电量降低了17.03%,COP_(s)提高了4.91%。 展开更多
关键词 光伏光热 双源热泵 空气源热泵 水源热泵 运行模式 切换模式 系统性能系数(COP_(s))
下载PDF
光伏光热联合双源热泵系统运行模式研究(2):供暖季系统仿真研究 被引量:1
19
作者 曲明璐 白宇森 +1 位作者 闫楠楠 张斌 《暖通空调》 2024年第9期87-92,共6页
使用TRNSYS软件建立了光伏光热-双源热泵(PV/T-DSHP)系统的仿真模型。选取夏热冬冷地区某一近零能耗居住建筑作为研究对象,模拟研究了供暖季PV/T-DSHP系统在COP_(s)切换模式下的运行特性和能耗。结果表明:平均光电效率为15.08%,平均光... 使用TRNSYS软件建立了光伏光热-双源热泵(PV/T-DSHP)系统的仿真模型。选取夏热冬冷地区某一近零能耗居住建筑作为研究对象,模拟研究了供暖季PV/T-DSHP系统在COP_(s)切换模式下的运行特性和能耗。结果表明:平均光电效率为15.08%,平均光热效率为33.05%;水源热泵运行模式下供暖季平均COP为4.55,空气源热泵运行模式下供暖季平均COP为3.19,PV/T-DSHP系统的平均COP_(s)为2.98;供暖季系统自满足率为61%。 展开更多
关键词 光伏光热 双源热泵 水源热泵 空气源热泵 运行模式 近零能耗建筑 性能系数(COP)
下载PDF
中深层地埋管热泵供热系统运行特性实测研究 被引量:2
20
作者 邓杰文 彭晨玮 +5 位作者 朱超 李骥 孔维政 李建峰 强文博 魏庆芃 《暖通空调》 2024年第4期113-119,共7页
通过大量工程实测研究,总结了中深层地埋管热泵供热技术的运行特性。中深层地埋管具有出水温度高、取热功率大、长期运行稳定的特点,为热泵系统提供了高品位的低温热源,以提升其运行性能;同时中深层地埋管自身存在间歇蓄热特性,能很好... 通过大量工程实测研究,总结了中深层地埋管热泵供热技术的运行特性。中深层地埋管具有出水温度高、取热功率大、长期运行稳定的特点,为热泵系统提供了高品位的低温热源,以提升其运行性能;同时中深层地埋管自身存在间歇蓄热特性,能很好地满足建筑供热需求变化与柔性用能;无级变频热泵机组更适合与中深层地埋管匹配运行,节能减排效果显著;热源侧水系统具有小流量、大扬程,且阻力随着流量变化而大幅度变化的特性。研究结果可为提升该技术的供热性能提供关键指导。 展开更多
关键词 中深层地埋管 热泵系统 热源侧水系统 运行特征 阻力特性 实测研究
下载PDF
上一页 1 2 190 下一页 到第
使用帮助 返回顶部