Quantification of trace amounts of impurities in high purity cobalt by high resolution inductively coupled plasma mass spectrometry 被引量:10
1
作者 XIE Hualin HUANG Kelong +1 位作者 NIE Xidu TANG Yougen 《Rare Metals》 SCIE EI CAS CSCD 2007年第3期286-291,共6页
A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, ... A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect standard addition method
下载PDF
Determination of trace elements in high purity nickel by high resolution inductively coupled plasma mass spectrometry 被引量:11
2
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2012年第9期2416-2420,共5页
The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss... The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity nickel trace element matrix effect internal standard
下载PDF
Quantification of Trace Amounts of Impurities in High Purity Cobalt by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:3
3
作者 Hua Lin XIE Xi Du NIE You Gen TANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1077-1080,共4页
An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ... An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect spectral interference internal standards.
下载PDF
Direct Determination of Trace Impurities in High Purity Zinc Oxide by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:2
4
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2006年第2期28-32,共5页
The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuter... The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented. 展开更多
关键词 high purity zinc oxide trace impurities high resolution inductively coupled plasma mass spectrometry spectral interferences microwave digestion
下载PDF
Determination of Trace Elements in High Purity Gold by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:1
5
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2009年第4期608-612,共5页
Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/... Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/ interference, measurements were acquired in both medium and high resolution modes. The matrix effects due to the presence of excessive HCl and Au were evaluated. The optimum conditions for the determination was tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits range from 0.01ug/g to 0.28ug/g depending on the elements. The method is accurate, quick and convenient. It has been applied to the determination of trace elements in high purity gold with satisfactory results. 展开更多
关键词 high purity gold trace elements high resolution inductively coupled plasma mass spectrometry spectral interferences
原文传递
High Resolution Mass Spectrometry for the Recognition and Structural Characterization of a New Antimicrobial Compound 被引量:1
6
作者 cia Carrano +1 位作者 Annamaria Naggi Elena Urso 《Pharmacology & Pharmacy》 2018年第5期135-148,共14页
Identification of novel specialized metabolites or bioactive compounds represents the main objective in the research field of natural product leads and drug discovery. Mass spectrometry (MS) provides a central tool to... Identification of novel specialized metabolites or bioactive compounds represents the main objective in the research field of natural product leads and drug discovery. Mass spectrometry (MS) provides a central tool to expedite and make more efficient the discovery and isolation phases, while minimizing the waste of resources on rediscovery of known compounds. MS contributes acutely to elucidation and identification of numerous species because it allows molecular mass and structural features determination. In particular, identification of the elemental composition of a precursor ion of interest by accurate mass measurement and investigation of dissociative processes undergone by the molecule, represent a worthy methodology to access the structure assignment. The aim of this study was to discover and identify novel antibacterial drugs from microbial source in a jungle of already known compounds. The focus of this paper is on the analytical strategy that permitted the disclosure of a new compound, otherwise confused with other substances. Emphasis is placed on the interpretation of the ESI-MS/MS fragmentation pattern that combined with high resolution mass determination, allowed step by step to properly deduce the exact molecular formula of an unknown component with a molecular weight higher than 1500 Daltons. 展开更多
关键词 Antibiotic Development Antibiotic Discovery high resolution mass spectrometry Molecular FORMULA MS/MS FRAGMENTATION FT ICR MS
下载PDF
Simultaneous Determination of Ultraviolet Absorbers and Antibacterial Agents in Textiles by Ultra-High Performance Liquid Chromatography/Orbitrap High Resolution Mass Spectrometry 被引量:1
7
作者 Chengyun Wang Tangtang Xie +2 位作者 Rong Xu Junfeng Lin Lixia Li 《World Journal of Engineering and Technology》 2017年第1期1-18,共18页
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl... This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles. 展开更多
关键词 Ultra-high Performance Liquid Chromatography/Orbitrap high resolution mass spectrometry Benzotriazoleultraviolet ABSORBERS Isothiazolinone Tric-losan 4-Chloro-3 5-Dimethyl Phenol
下载PDF
Data Analysis for High Throughput Detection of 18 Phthalates in Textiles Based on High Resolution Mass Spectrometry
8
作者 QU Lianyi LUO Xin +5 位作者 NIU Zengyuan YE Xiwen ZHANG Li TANG Zhixu ZHANG Lin ZHU Ping 《Journal of Donghua University(English Edition)》 EI CAS 2019年第2期158-162,共5页
Liquid chromatography coupled to high resolution mass spectrometry(LC-HRMS)was used to establish a high throughput and sensitive method for 18 phthalic acid esters(PAEs)in textiles.The method was applied to screen PAE... Liquid chromatography coupled to high resolution mass spectrometry(LC-HRMS)was used to establish a high throughput and sensitive method for 18 phthalic acid esters(PAEs)in textiles.The method was applied to screen PAEs in 413 textile samples and 7 434 pieces of test data were analyzed.Further discussion was conducted about specific compounds,textile materials,detected value distribution and positive rate of samples.Twenty-nine percent of samples were detected with PAEs,and no samples were detected beyond regulations.Diisobutyl phthalate(DiBP),Dibutyl phthalate(DBP)and Di-2-ethylhexyl phthalate(DEHP)were detected with high frequency,and most samples were fabrics with coating and printing.This study can be used to reflect distribution of phthalate residues in textiles on the market and provide data support for risk assessment of PAEs for textile producers and consumers. 展开更多
关键词 high resolution mass spectrometry TEXTILE phthalic acid ESTERS PAES data analysis
下载PDF
Discovery of pulmonary fibrosis inhibitor targeting TGF-b RI in Polygonum cuspidatum by high resolution mass spectrometry with in silico strategy
9
作者 Huarong Xu Jiameng Qu +4 位作者 Jian Wang Kefei Han Qing Li Wenchuan Bi Ran Liu 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第6期860-868,共9页
Pulmonary fibrosis(PF)is an irreversible lung disease that is characterized by excessive scar tissue with a poor median survival rate of 2-3 years.The inhibition of transforming growth factor-β receptor type-I(TGF-β... Pulmonary fibrosis(PF)is an irreversible lung disease that is characterized by excessive scar tissue with a poor median survival rate of 2-3 years.The inhibition of transforming growth factor-β receptor type-I(TGF-β RI)by an appropriate drug may provide a promising strategy for the treatment of this disease.Polygonum cuspidatum(PC)is a well-known traditional Chinese herbal medicine which has an anti-PF effect.Accordingly,a combination of high resolution mass spectrometry with an in silico strategy was developed as a new method to search for potential chemical ingredients of PC that target the TGF-β RI.Based on this strategy,a total of 24 ingredients were identified.Then,absorption,distribution,metabolism,and excretion(ADME)-related properties were subsequently predicted to exclude compounds with potentially undesirable pharmacokinetics behaviour.Molecular docking studies on TGF-β RI were adopted to discover new PF inhibitors.Eventually,a compound that exists in PC known as resveratrol was proven to have excellent biological activity on TGF-β RI,with an IC_(50) of 2.211 μM in vitro.Furthermore,the complex formed through molecular docking was tested via molecular dynamics simulations,which revealed that resveratrol had strong interactions with residues of TGF-β RI.This study revealed that resveratrol has significant potential as a treatment for PF due to its ability to target TGF-β RI.In addition,this research demonstrated the exploration of natural products with excellent biological activities toward specific targets via high resolution mass spectrometry in combination with in silico technology is a promising strategy for the discovery of novel drugs. 展开更多
关键词 Polygonum cuspidatum Pulmonary fibrosis TGF-βreceptor type-I RESVERATROL high resolution mass spectrometry Molecular docking
下载PDF
Software-aided detection and structural characterization of cyclic peptide metabolites in biological matrix by high-resolution mass spectrometry
10
作者 Ming Yao Tingting Cai +3 位作者 Eva Duchoslav Li Ma Xu Guo Mingshe Zhu 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2020年第3期240-246,共7页
Compared to their linear counterparts,cyclic peptides show better biological activities,such as antibacterial,immunosuppressive,and anti-tumor activities,and pharmaceutical properties due to their conformational rigid... Compared to their linear counterparts,cyclic peptides show better biological activities,such as antibacterial,immunosuppressive,and anti-tumor activities,and pharmaceutical properties due to their conformational rigidity.However,cyclic peptides could form numerous putative metabolites from potential hydrolytic cleavages and their fragments are very difficult to interpret.These characteristics pose a great challenge when analyzing metabolites of cyclic peptides by mass spectrometry.This study was to assess and apply a software-aided analytical workflow for the detection and structural characterization of cyclic peptide metabolites.Insulin and atrial natriuretic peptide(ANP)as model cyclic peptides were incubated with trypsin/chymotrypsin and/or rat liver S9,followed by data acquisition using TripleTOF?5600.Resultant full-scan MS and MS/MS datasets were automatically processed through a combination of targeted and untargeted peak finding strategies.MS/MS spectra of predicted metabolites were interrogated against putative metabolite sequences,in light of a,b,y and internal fragment series.The resulting fragment assignments led to the confirmation and ranking of the metabolite sequences and identification of metabolic modification.As a result,29 metabolites with linear or cyclic structures were detected in the insulin incubation with the hydrolytic enzymes.Sequences of twenty insulin metabolites were further determined,which were consistent with the hydrolytic sites of these enzymes.In the same manner,multiple metabolites of insulin and ANP formed in rat liver S9 incubation were detected and structurally characterized,some of which have not been previously reported.The results demonstrated the utility of software-aided data processing tool in detection and identification of cyclic peptide metabolites. 展开更多
关键词 Atrial natriuretic peptide Metabolism of cyclic peptide high resolution mass spectrometry INSULIN Software-aided data processing
下载PDF
Application of Liquid Chromatography-High Resolution Time-of-flight Mass Spectrometry in the Detection of Raw Milk and Dairy Products
11
作者 Yi LI Luman HUO +5 位作者 Lixue DONG Xuesong WANG Litian ZHANG Ruihuan DU Aijun LI Lei WANG 《Agricultural Biotechnology》 CAS 2021年第1期111-113,共3页
Milk and dairy products are more and more popular with consumers due to their various nutrients, and their quality and safety issues have always been concerned. Therefore, the development of rapid, accurate and simple... Milk and dairy products are more and more popular with consumers due to their various nutrients, and their quality and safety issues have always been concerned. Therefore, the development of rapid, accurate and simple screening techniques is of great significance. Liquid chromatography-high resolution time-of-flight mass spectrometry has high-resolution and high-throughput detection functions, and has gradually begun to be applied in the detection of milk and dairy products. This paper summarized the application of milk and dairy products in liquid chromatography-high resolution time-of-flight mass spectrometry, laying a foundation for the development of new methods. 展开更多
关键词 Milk and dairy products high resolution time-of-flight mass spectrometry Pesticide and veterinary drug residues
下载PDF
Determination of Sym-triazine Residues in Animal-derived Food by Liquid Chromatography-High Resolution Mass Spectrometry
12
作者 Gong Xiaoming Yang Lijun +4 位作者 Wang Hongtao Ma Ronggui Ding Kuiying Guo Liqiang Sun Jun 《Animal Husbandry and Feed Science》 CAS 2016年第3期146-150,共5页
[Objective]The research aimed to establish a liquid chromatography-high-resolution mass spectrometry for detecting residues of diclazuril,toltrazuril and its metabolites in animal-derived food.[Method]The samples were... [Objective]The research aimed to establish a liquid chromatography-high-resolution mass spectrometry for detecting residues of diclazuril,toltrazuril and its metabolites in animal-derived food.[Method]The samples were pre-treated by QuEChERS technology and detected by Exactive liquid chromatography-high resolution mass spectrometry.The liquid chromatography-high-resolution mass spectrometry for detecting the residues of diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide in animal-derived food was established.[Result]Diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide showed a good linear correlation in the range of 2.0-50.0μg/L(r^2〉0.99).The average recoveries of these four compounds in bovine power at the spiked levels of 2,10 and 20μg/kg were 74.5%-90.1%,and the relative standard deviations(RSD)were 15.4%-17.5%.[Conclusion]This method was stable and reliable,and could be used to detect diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide in animal-derived food. 展开更多
关键词 Animal-derived food Sym-triazine drugs QuEChERS Liquid chromatography-high-resolution mass spectrometry
下载PDF
The determination of 52 elements in marine geological samples by an inductively coupled plasma optical emission spectrometry and an inductively coupled plasma mass spectrometry with a high-pressure closed digestion method 被引量:16
13
作者 GAO Jingjing LIU Jihua +3 位作者 LI Xianguo YAN Quanshu WANG Xiaojing WANG Hongmin 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第1期109-117,共9页
An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud... An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples. 展开更多
关键词 marine geological sample high-pressure closed digestion method inductively coupled plasma optical emission spectrometry inductively coupled plasma mass spectrometry major element minor element trace element
下载PDF
Development of an automatic measurement system using atmospheric pressure photoionization ultrahigh-resolution mass spectrometry and application for on-line analysis of particulate matter
14
作者 Yayuan Dong Ranran Liu +4 位作者 Ling Xie Xiaole Pan Yele Sun Lin Wu ZifaWang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2024年第4期516-530,共15页
On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real tim... On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real time.Here we describe the development and application of an automatic measurement system that incorporates PM_(2.5)sampling,thermal desorption,atmospheric pressure photoionization,and UHRMS analysis.Molecular formulas of detected organic compounds were deducted from the accurate(±10 ppm)molecular weights obtained at a mass resolution of 100,000,allowing the identification of small organic compounds in PM_(2.5).Detection efficiencies of 28 standard compounds were determined and we found a high sensitivity and selectivity towards organic amines with limits of detection below 10 pg.As a proof of principle,PM_(2.5)samples collected off-line in winter in the urban area of Beijing were analyzed using the Ionization Module and HRMS of the system.The automatic system was then applied to conduct on-line measurements during the summer time at a time resolution of 2 hr.The detected organic compounds comprised mainly CHON and CHN compounds below 350 m/z.Pronounced seasonal variations in elemental composition were observed with shorter carbon backbones and higher O/C ratios in summer than that in winter.This result is consistent with stronger photochemical reactions and thus a higher oxidation state of organics in summer.Diurnal variation in signal intensity of each formula provides crucial information to reveal its source and formation pathway.In summary,the automatic measurement system serves as an important tool for the on-line characterization and identification of organic species in PM_(2.5). 展开更多
关键词 PM_(2.5) Chemical composition On-line measurement technique high resolution mass spectrometry
原文传递
Expansion Strategy-Driven Micron-Level Resolution Mass Spectrometry Imaging of Lipids in Mouse Brain Tissue
15
作者 Yik Ling Winnie Hung Chengyi Xie +6 位作者 Jianing Wang Xin Diao Ruxin Li Xiaoxiao Wang Shulan Qiu Jiacheng Fang Zongwei Cai 《CCS Chemistry》 CSCD 2024年第11期2662-2670,共9页
A novel method for enhanced resolution,termed expansion mass spectrometry imaging,has been developed for lipid mass spectrometry imaging,utilizing existing commercially available mass spectrometers without necessitati... A novel method for enhanced resolution,termed expansion mass spectrometry imaging,has been developed for lipid mass spectrometry imaging,utilizing existing commercially available mass spectrometers without necessitating modifications.This approach involves embedding tissue sections in a swellable polyelectrolyte gel,with the target biomolecules indirectly anchored to the gel network.By employing matrix-assisted laser desorption ionization mass spectrometry imaging,the method has realized an enhanced spatial resolution that surpasses the conventional resolution limits of commercial instruments by approximately 4.5 fold.This enhancement permits the detailed visualization of intricate structures within the mouse brain at a subcellular level,with a lateral resolution nearing 1μm.As a physical technique for achieving resolution beyond standard capabilities,this readily adaptable approach presents a powerful tool for high-definition imaging in biological research. 展开更多
关键词 mass spectrometry imaging MALDI imaging spatial lipidomics subcellular imaging EXPANSION molecular imaging high resolution
下载PDF
响应面分析法在HR-ICP-MS仪器参数优化中的应用 被引量:3
16
作者 顾雪 徐进力 +3 位作者 王琦 白金峰 张勤 刘亚轩 《物探化探计算技术》 CAS CSCD 2017年第6期841-847,共7页
通过响应面分析法,对辅助气流量、雾化气流量和采样深度三个影响高分辨感耦等离子体质谱仪测定灵敏度的主要仪器参数进行了系统优化。应用中心组分设计得到了覆盖整个质量数范围和低、中、高三种分辨率模式的信号强度响应值,经过多项式... 通过响应面分析法,对辅助气流量、雾化气流量和采样深度三个影响高分辨感耦等离子体质谱仪测定灵敏度的主要仪器参数进行了系统优化。应用中心组分设计得到了覆盖整个质量数范围和低、中、高三种分辨率模式的信号强度响应值,经过多项式回归运算建立信号平均值的数学模型,模型整体对响应值高度显著,R2=0.9944。通过典型分析,得到在全质量数范围内的最优仪器参数为:辅助气流量为0.56L/min;雾化气流量为0.95L/min;采样深度为-2.3mm,所得响应面及等高线图直观地显示了仪器参数之间的交互影响作用。响应面分析法通过较少的实验次数,得到了更加科学、合理的仪器最优化参数。 展开更多
关键词 高分辨感耦等离子体质谱仪 响应面分析 参数优化
下载PDF
高分辨电感耦合等离子体质谱(HR-ICP-MS)法测定土壤污染状况调查样品中的49种元素 被引量:16
17
作者 袁源 赵平 +1 位作者 陈海杰 王吉 《中国无机分析化学》 CAS 北大核心 2021年第1期12-19,共8页
全国重点行业企业用地土壤污染状况调查样品分析工作的特点是项目复杂、配套分析方法种类多,缺乏针对大多数无机元素同时测定的方法。建立了一种基于高分辨电感耦合等离子体质谱法(HR-ICP-MS)的分析方法,采用密闭酸溶消解样品,HR-ICP-M... 全国重点行业企业用地土壤污染状况调查样品分析工作的特点是项目复杂、配套分析方法种类多,缺乏针对大多数无机元素同时测定的方法。建立了一种基于高分辨电感耦合等离子体质谱法(HR-ICP-MS)的分析方法,采用密闭酸溶消解样品,HR-ICP-MS法测定样品中Li、Be、Ti、V、Cr、Mn、Co、Ni、Cu、Zn、Ga、Ge、As、Rb、Sr、Zr、Nb、Mo、Cd、In、Sn、Sb、Te、Cs、Ba、Hf、Ta、W、Tl、Pb、Bi、Th、U以及稀土元素等49种元素。系统研究了质谱干扰并择优选择了测定元素同位素,采用国家一级有证土壤标准物质对方法性能进行了考察,49种元素方法检出限为0.001~0.46 mg/kg,相对标准偏差(RSD,n=8)为0.75%~8.9%,准确度(相对误差RE,Be、As、Cd、Sb)为-5.4%~7.4%,准确度(对数误差ΔlgC,除Te外其余元素)为-0.05~0.04。方法的主要技术参数满足13个企业用地调查分析标准的要求,可为本次调查工作提供一种可借鉴的高效率分析手段。 展开更多
关键词 土壤污染状况调查 多元素分析 高分辨电感耦合等离子体质谱法
下载PDF
微波消解-高分辨电感耦合等离子体质谱(HR-ICP-MS)法测定原油中22种微量元素 被引量:3
18
作者 李银花 赵雨薇 +1 位作者 刘曙 安雅睿 《中国无机分析化学》 CAS 北大核心 2022年第6期94-102,共9页
准确测定原油中微量元素含量,对研究原油地球化学,揭示原油原产地信息,具有重要意义。通过采用微波消解原油样品,优化样品质量、消解试剂、消解程序等微波消解条件,考察原油中B、Mg、Al、P、Ti、Ca、V、Cr、Mn、Fe、Co、Ni、Cu、Zn、Ga... 准确测定原油中微量元素含量,对研究原油地球化学,揭示原油原产地信息,具有重要意义。通过采用微波消解原油样品,优化样品质量、消解试剂、消解程序等微波消解条件,考察原油中B、Mg、Al、P、Ti、Ca、V、Cr、Mn、Fe、Co、Ni、Cu、Zn、Ga、As、Sr、Mo、Cd、Sn、Ba、Pb等22种微量元素在低、中、高分辨率下的质谱干扰及校正方法,采用高分辨测定Ca,中分辨测定P、V、Cr、Mn、Fe、Ni、Cu、Cd、Co、Sr,低分辨率模式测定其余元素,建立了微波消解-高分辨电感耦合等离子体质谱(HR-ICP-MS)法测定原油中22种元素的方法。在优化的实验条件下,22种元素的线性相关系数均大于0.999,方法检出限为0.0002~0.07μg/g。选择原油多元素均质标准品(Conostan S-21)进行方法验证,B、Mg、Al、P、Ti、Ca、V、Cr、Mn、Fe、Ni、Cu、Zn、Mo、Cd、Sn、Ba、Pb元素测定结果的相对标准偏差为0.20%~2.8%,测定值与标准值基本一致;选择巴西原油、安哥拉原油、喀麦隆原油、尼日利亚原油进行Co、Ga、As、Sr元素加标回收实验,加标回收率为95.3%~104%,测定结果的相对标准偏差为0.20%~2.3%。选取巴西原油、安哥拉原油、喀麦隆原油、尼日利亚原油进行22种元素测定,分析了不同产地原油的元素含量差异。方法能够应用于原油中多种微量元素的同时测定,灵敏度高,选择性好,检出限低,结果准确可靠,可为原油地球化学研究提供技术支持。 展开更多
关键词 原油 微量元素 微波消解 高分辨电感耦合等离子体质谱
下载PDF
基于UHPLC-Q-Exactive Orbitrap HRMS技术结合化学计量学方法的不同干燥处理杜仲叶成分分析 被引量:1
19
作者 李淑芳 王会锋 +6 位作者 郝学飞 胡永建 李圆圆 马风莲 冯书惠 杨亚琴 于永杰 《分析测试学报》 CAS CSCD 北大核心 2024年第2期213-225,共13页
采用基于液质联用的非靶向代谢组学技术结合化学计量学数据自动解析软件AntDAS-LCHRMS分析了4种不同干燥处理(冻干、热泵烘干、电热烘干、晒干)杜仲叶样本中的化合物。杜仲叶样本数据由超高效液相色谱-四极杆-静电场轨道阱高分辨质谱(UH... 采用基于液质联用的非靶向代谢组学技术结合化学计量学数据自动解析软件AntDAS-LCHRMS分析了4种不同干燥处理(冻干、热泵烘干、电热烘干、晒干)杜仲叶样本中的化合物。杜仲叶样本数据由超高效液相色谱-四极杆-静电场轨道阱高分辨质谱(UHPLC-Q-Exactive Orbitrap HRMS)分别在正、负离子模式下进行采集,经AntDAS-LCHRMS软件解析,共鉴定出71种差异性化合物,经标准品验证确定40种化合物,包括环烯醚萜类、有机酸类、黄酮类、氨基酸类、核苷类、维生素类等9类物质。其中,正、负离子模式下均可识别并验证的化合物有车叶草苷、绿原酸、芦丁、异槲皮苷、车叶草苷酸、京尼平苷等25种化合物。层次聚类分析(HCA)及主成分分析(PCA)结果均显示,相同处理的杜仲叶样本各自聚成一类,不同处理的杜仲叶样本可明显区分。热图分析进一步揭示了不同干燥处理杜仲叶样本中差异性化合物的含量变化。晒干处理样本中苯丙氨酸及色氨酸等氨基酸类物质的水平较高;冻干及热泵烘干处理样本中有机酸类、环烯醚萜类、糖类等含量较高;电热烘干样本中核苷类、黄酮类物质的含量较高;黄酮类物质在冻干、热泵烘干及晒干样本中差异较小。研究结果为不同干燥处理杜仲叶的成分分析、品质评价及其开发应用提供了科学依据,也可为其他复杂药用植物体系的化学成分分析提供参考。 展开更多
关键词 杜仲叶 代谢组学 化学计量学 AntDAS-LCHRMS软件 超高效液相色谱-四极杆-静电场轨道阱高分辨质谱(UHPLC-Q-Exactive Orbitrap HRMS) 干燥处理
下载PDF
超高效液相色谱-四极杆-飞行时间高分辨质谱用于化妆品中15种前列腺素类似物的快速筛查和测定
20
作者 陈安丽 张静 +1 位作者 黄子沣 严小红 《分析测试学报》 CAS CSCD 北大核心 2024年第7期1011-1017,共7页
建立了超高效液相色谱-四极杆-飞行时间高分辨质谱(UPLC-Q-TOF MS)快速筛查和测定化妆品中15种前列腺素类似物的方法。样品以饱和氯化钠作为分散剂(蜡质类样品以四氢呋喃分散),经乙腈提取,离心取上清液过滤后,采用Poroshell 120 EC-C_(... 建立了超高效液相色谱-四极杆-飞行时间高分辨质谱(UPLC-Q-TOF MS)快速筛查和测定化妆品中15种前列腺素类似物的方法。样品以饱和氯化钠作为分散剂(蜡质类样品以四氢呋喃分散),经乙腈提取,离心取上清液过滤后,采用Poroshell 120 EC-C_(18)柱(150 mm×3.0 mm,2.7μm)分离,以5 mmol/L甲酸铵(含0.1%甲酸)-乙腈为流动相梯度洗脱。在ESI正离子模式下,采用Targeted MS/MS模式采集15种前列腺素类似物的质谱信息,构建筛查数据库进行快速筛查,确证后的目标物通过外标法定量。结果表明,15种前列腺素类似物的线性关系良好,相关系数(r^(2))均大于0.99;检出限为0.3~17.6μg/g,定量下限为1.1~58.8μg/g。在低、中、高3个加标水平下,水剂、膏霜、乳类、粉类、凝胶5类化妆品基质的回收率为70.1%~134%,相对标准偏差不大于7.5%。该方法简单高效、准确度好,可用于化妆品中前列腺素类似物的定性确证和定量分析,为化妆品风险识别提供技术支撑。 展开更多
关键词 超高效液相色谱-四极杆-飞行时间高分辨质谱 快速筛查 化妆品 前列腺素类似物
下载PDF