AIM To determine the prevalence and diagnostic value of autoantibodies inα-fetoprotein(AFP)-negative hepatocellular carcinoma(HCC).METHODS Fifty-six serum samples from AFP-negative HCC cases,86 from AFP-positive HCC ...AIM To determine the prevalence and diagnostic value of autoantibodies inα-fetoprotein(AFP)-negative hepatocellular carcinoma(HCC).METHODS Fifty-six serum samples from AFP-negative HCC cases,86 from AFP-positive HCC cases,168 from chronic liver disease cases,and 59 from normal human controls were included in this study.Autoantibodies to nucleophosmin(NPM)1,14-3-3zeta and mouse double minute 2 homolog(MDM2)proteins in AFP-negative HCC serum were evaluated by enzymelinked im munosorbent assay.Partially positive sera were further evaluated by western blotting.Immunohistochemistry was used to detect the expression of three tumor-associated antigens(TAAs)in AFP-negative HCC and normal control tissues.RESULTS The frequency of autoantibodies to the three TAAs in AFP-negative HCC sera was 21.4%,19.6%and 19.6%,which was significantly higher than in the chronic liver disease cases and normal human controls(P<0.01)as well as AFP-positive HCC cases.The sensitivity of the three autoantibodies for diagnosis of AFP-negative HCC ranged from 19.6%to 21.4%,and the specificity was approximately 95%.When the three autoantibodies were combined,the sensitivity reached 30.4%and the specificity reached 91.6%.CONCLUSION Autoantibodies to NPM1,14-3-3zeta and MDM2 may be useful biomarkers for immunodiagnosis of AFP-negative HCC.展开更多
Cystic echinococcosis(CE) is a zoonotic parasitic infection caused by the larval stage of Echinococcus granulosus. Diagnosis of CE mainly relies on a combination of serological testing along with imaging approaches. A...Cystic echinococcosis(CE) is a zoonotic parasitic infection caused by the larval stage of Echinococcus granulosus. Diagnosis of CE mainly relies on a combination of serological testing along with imaging approaches. A variety of serological methods, mainly based on hydatid cyst fluid, antigen B(Ag B) and antigen 5, have been developed and used for immunodiagnosis of CE, yet their performances are not satisfactory. Although utilizing of recombinant or synthetic antigens, improved the performance of serological tests, it has not applicably overcome the problem of low sensitivity and cross reactivity, seen in the diagnosis of CE. Performances of immunodiagnostic tests based on Ag B subunits are promising. The 8 k Da subunit of Ag B is the most studied antigen in native, synthetic or recombinant form for diagnosis of CE. From the 5 subunits of Ag B, antigen B8/1 and B8/2 provided the highest diagnostic sensitivity and specificity. Moreover, detecting of specific antibodies of Ig G subclasses has improved the efficacy of immunodiagnostic tests. Among the Ig G subclasses, both Ig G2 and Ig G4 are considered as good markers for diagnosis and Ig G4 as a suitable marker for follow up of the patients. In this review an overview of immunodiagnostic methods, related antigens and their performances in the diagnosis of CE are given. The paper highlights pitfall and challenges in the serological diagnosis of CE. Moreover, limitation of currently available immunodiagnostic tests and the most recent development in the designing and application of serological assays for diagnosis of CE in human are addressed.展开更多
Objective: To identify the monoclonal antibody specific to Aeromonas spp., a Gram negative bacteria causing gastroenteritis and wound infection. Methods: The monoclone, namely 88 F2-3 F4, was produced from hybridoma t...Objective: To identify the monoclonal antibody specific to Aeromonas spp., a Gram negative bacteria causing gastroenteritis and wound infection. Methods: The monoclone, namely 88 F2-3 F4, was produced from hybridoma technology. The specificity of antibody secreted from 88 F2-3 F4 was tested against other Gram negative bacteria frequently found in gastrointestinal tract. Then the antibody was used for searching Aeromonas antigens in artificial seeded rectal swab cultures by dot-blot enzyme linked immunosorbent assay. Results: 88 F2-3 F4 produced an antibody that recognized an antigen with a molecular mass of 8.5 k Da in all 123 isolates of the seven Aeromonas species tested, but recognized no epitope of any other Gram-negative bacterium typically found in the gastrointestinal tract. A dot-blot enzyme linked immunosorbent assay based on this antibody showed 86.49% sensitivity and 92.13% specificity. Conclusions: 88 F2-3 F4 monoclonal antibody could react with all Aeromonas isolates, but not other Gram negative bacteria, therefore it should be a useful tool for the detection of Aeromonas antigen in clinical and environmental samples.展开更多
Objective:To assess the diagnostic efficacy of the currently most widely used indirect hemagglutination assay(IHA) and enzyme-linked immunosorbent assay(ELISA) for detection of Schistosoma japonicum human infections.M...Objective:To assess the diagnostic efficacy of the currently most widely used indirect hemagglutination assay(IHA) and enzyme-linked immunosorbent assay(ELISA) for detection of Schistosoma japonicum human infections.Methods:A comprehensive search was undertaken from China National Knowledge Infrastructure,Wanfang Database.VIP Database,PubMed. Cochrane Library,Science Citation Index Expanded.Proquest,and the inclusion and exclusion criteria were strictly settled.The funnel plot was used to assess the publication bias.Cochran’s Q test was employed to measure the homogeneity between studies,a summary receiver operating characteristic(SROC) curve was used to compare the diagnostic accuracy between the IHA and ELISA qualitatively by means of the Weighted Least Square method,the Ordinary Least Square method and the Robust regression method,and the diagnostic odds ratio(DOR) was drawn to compare the accuracy quantitatively.Results:Out of 785 publications,19 papers were eventually selected for analysis.Literature finality assessment indicated that minor publication bias existed in studies pertaining IHA test,but no bias was found in literatures regarding ELISA test.The heterogeneity test showed a heterogeneity between studies was present(χ~2 =466.07 and 34.67. both P values【0.0001).The areas under the SROC curves of IHA were all higher than that of ELISA test using the three methods(Weighted Least Square method:0.766 vs.0.695.Ordinary Least Square method:0.826 vs.0.741.Robust regression:0.815 vs.0.715).The TPR* values for IHA and EUSA were 0.710.0.759.0.749.and 0.650.0.686 and 0.666.respectively,and OR values were 5.997.9.937.8.893.and 3.432.4.784 and 3.959.respectively.The DOR of IHA was 9.41(95% CI:4.88-18.18).and 4.78(95%CI:3.21-7.13) for ELISA.Conclusions:All above results revealed that the diagnostic performance of IHA is better than that of ELISA.However,taking into account their unsatisfactory diagnostic value in areas with low infection intensity,a search for a better diagnostic test that can be applied in field situations in China should be given high priority.展开更多
Background:Schistosomiasis remains a major public health concern in China and an epidemiological survey has revealed that schistosome-infected bovines and goats are the main transmission sources for the disease.Theref...Background:Schistosomiasis remains a major public health concern in China and an epidemiological survey has revealed that schistosome-infected bovines and goats are the main transmission sources for the disease.Therefore,development of a sensitive technique for the diagnosis of schistosomiasis in domestic animals is necessary.Method:A novel colloidal gold immunochromatography assay(GICA)strip was developed for detecting Schistosoma japonicum in domestic animals.The colloidal gold was conjugated with recombinant streptococcal protein G(rSPG).As the test and control lines,the schistosome soluble egg antigen and rSPG,respectively,were blotted on nitrocellulose membrane.Results:The lowest detectable serum dilution was 1∶640 for schistosome-infected buffaloes.The cross-reaction rate of GICA was 14.29%with Paramphistomum sp.in buffaloes,16.67%with Haemonchus sp.in goats,and 33.33%with Orientobilharzia sp.in goats.These results were slightly lower and similar to those obtained through ELISA.Moreover,the strips for detecting S.japonicum in mice,rabbits,buffaloes,and goats showed high sensitivity(100.00%,100.00%,100.00%,and 100.00%,respectively)and specificity(100.00%,100.00%,94.23%,and 88.64%,respectively).And the sensitivity or specificity of the GICA strips did not present any significant differences after storage for 12 months at room temperature.When compared with ELISA,the GICA strips exhibited similar sensitivity and specificity in the diagnosis of schistosomiasis in mice,rabbits,buffaloes,and goats.Besides,only 5μl of serum are required for the test and the detection can be completed within 5 min.Conclusion:This study is the first to develop a GICA strip using gold-rSPG conjugate for the diagnosing of schistosomiasis in domestic animals,and preliminary results showed that the developed strip may be suitable for large-scale screening of schistosomiasis in endemic areas.展开更多
基金Supported by Clinical Research Cooperation Fund of the Capital Medical University,No.15JL67Project of Science and Technology Development Plan of Beijing Municipal Education Commission,No.KM201610025021+2 种基金High-Tech Personnel Training Program of Beijing Health System,No.2015-3-104Beijing Municipal Science and Technology Commission,No.Z151100004015066Shaanxi Science and Technology Coordination and Innovation Project,No.2016KTZDSF02-02
文摘AIM To determine the prevalence and diagnostic value of autoantibodies inα-fetoprotein(AFP)-negative hepatocellular carcinoma(HCC).METHODS Fifty-six serum samples from AFP-negative HCC cases,86 from AFP-positive HCC cases,168 from chronic liver disease cases,and 59 from normal human controls were included in this study.Autoantibodies to nucleophosmin(NPM)1,14-3-3zeta and mouse double minute 2 homolog(MDM2)proteins in AFP-negative HCC serum were evaluated by enzymelinked im munosorbent assay.Partially positive sera were further evaluated by western blotting.Immunohistochemistry was used to detect the expression of three tumor-associated antigens(TAAs)in AFP-negative HCC and normal control tissues.RESULTS The frequency of autoantibodies to the three TAAs in AFP-negative HCC sera was 21.4%,19.6%and 19.6%,which was significantly higher than in the chronic liver disease cases and normal human controls(P<0.01)as well as AFP-positive HCC cases.The sensitivity of the three autoantibodies for diagnosis of AFP-negative HCC ranged from 19.6%to 21.4%,and the specificity was approximately 95%.When the three autoantibodies were combined,the sensitivity reached 30.4%and the specificity reached 91.6%.CONCLUSION Autoantibodies to NPM1,14-3-3zeta and MDM2 may be useful biomarkers for immunodiagnosis of AFP-negative HCC.
文摘Cystic echinococcosis(CE) is a zoonotic parasitic infection caused by the larval stage of Echinococcus granulosus. Diagnosis of CE mainly relies on a combination of serological testing along with imaging approaches. A variety of serological methods, mainly based on hydatid cyst fluid, antigen B(Ag B) and antigen 5, have been developed and used for immunodiagnosis of CE, yet their performances are not satisfactory. Although utilizing of recombinant or synthetic antigens, improved the performance of serological tests, it has not applicably overcome the problem of low sensitivity and cross reactivity, seen in the diagnosis of CE. Performances of immunodiagnostic tests based on Ag B subunits are promising. The 8 k Da subunit of Ag B is the most studied antigen in native, synthetic or recombinant form for diagnosis of CE. From the 5 subunits of Ag B, antigen B8/1 and B8/2 provided the highest diagnostic sensitivity and specificity. Moreover, detecting of specific antibodies of Ig G subclasses has improved the efficacy of immunodiagnostic tests. Among the Ig G subclasses, both Ig G2 and Ig G4 are considered as good markers for diagnosis and Ig G4 as a suitable marker for follow up of the patients. In this review an overview of immunodiagnostic methods, related antigens and their performances in the diagnosis of CE are given. The paper highlights pitfall and challenges in the serological diagnosis of CE. Moreover, limitation of currently available immunodiagnostic tests and the most recent development in the designing and application of serological assays for diagnosis of CE in human are addressed.
基金supported by Grant No.59/2549 from Mahidol University and Grant No.04/2554 from the Faculty of Tropical Medicine,Mahidol University,Bangkok,Thailand
文摘Objective: To identify the monoclonal antibody specific to Aeromonas spp., a Gram negative bacteria causing gastroenteritis and wound infection. Methods: The monoclone, namely 88 F2-3 F4, was produced from hybridoma technology. The specificity of antibody secreted from 88 F2-3 F4 was tested against other Gram negative bacteria frequently found in gastrointestinal tract. Then the antibody was used for searching Aeromonas antigens in artificial seeded rectal swab cultures by dot-blot enzyme linked immunosorbent assay. Results: 88 F2-3 F4 produced an antibody that recognized an antigen with a molecular mass of 8.5 k Da in all 123 isolates of the seven Aeromonas species tested, but recognized no epitope of any other Gram-negative bacterium typically found in the gastrointestinal tract. A dot-blot enzyme linked immunosorbent assay based on this antibody showed 86.49% sensitivity and 92.13% specificity. Conclusions: 88 F2-3 F4 monoclonal antibody could react with all Aeromonas isolates, but not other Gram negative bacteria, therefore it should be a useful tool for the detection of Aeromonas antigen in clinical and environmental samples.
基金Supported by the National S & T Major Projects(2008ZX10004-011)the National Science & Technology Pillar Program of China(2009BA178B06)+4 种基金the National Natural Science Foundation of China(81071379)the Natural Science Foundation of Jiangsu Province(BK2009076)the Jiangsu Provincial Scientific Foundation of Preventive Medicine(Y201031)Jiangsu Society for Editors of Scientific and Technical Periodicals(JKQJX006)the Department of Health.Jiangsu Province (X200912)
文摘Objective:To assess the diagnostic efficacy of the currently most widely used indirect hemagglutination assay(IHA) and enzyme-linked immunosorbent assay(ELISA) for detection of Schistosoma japonicum human infections.Methods:A comprehensive search was undertaken from China National Knowledge Infrastructure,Wanfang Database.VIP Database,PubMed. Cochrane Library,Science Citation Index Expanded.Proquest,and the inclusion and exclusion criteria were strictly settled.The funnel plot was used to assess the publication bias.Cochran’s Q test was employed to measure the homogeneity between studies,a summary receiver operating characteristic(SROC) curve was used to compare the diagnostic accuracy between the IHA and ELISA qualitatively by means of the Weighted Least Square method,the Ordinary Least Square method and the Robust regression method,and the diagnostic odds ratio(DOR) was drawn to compare the accuracy quantitatively.Results:Out of 785 publications,19 papers were eventually selected for analysis.Literature finality assessment indicated that minor publication bias existed in studies pertaining IHA test,but no bias was found in literatures regarding ELISA test.The heterogeneity test showed a heterogeneity between studies was present(χ~2 =466.07 and 34.67. both P values【0.0001).The areas under the SROC curves of IHA were all higher than that of ELISA test using the three methods(Weighted Least Square method:0.766 vs.0.695.Ordinary Least Square method:0.826 vs.0.741.Robust regression:0.815 vs.0.715).The TPR* values for IHA and EUSA were 0.710.0.759.0.749.and 0.650.0.686 and 0.666.respectively,and OR values were 5.997.9.937.8.893.and 3.432.4.784 and 3.959.respectively.The DOR of IHA was 9.41(95% CI:4.88-18.18).and 4.78(95%CI:3.21-7.13) for ELISA.Conclusions:All above results revealed that the diagnostic performance of IHA is better than that of ELISA.However,taking into account their unsatisfactory diagnostic value in areas with low infection intensity,a search for a better diagnostic test that can be applied in field situations in China should be given high priority.
基金This study was financially supported by the Basic Foundation for Scientific Research of State-level Public Welfare Institutes of China(Grant no.2014JB01).
文摘Background:Schistosomiasis remains a major public health concern in China and an epidemiological survey has revealed that schistosome-infected bovines and goats are the main transmission sources for the disease.Therefore,development of a sensitive technique for the diagnosis of schistosomiasis in domestic animals is necessary.Method:A novel colloidal gold immunochromatography assay(GICA)strip was developed for detecting Schistosoma japonicum in domestic animals.The colloidal gold was conjugated with recombinant streptococcal protein G(rSPG).As the test and control lines,the schistosome soluble egg antigen and rSPG,respectively,were blotted on nitrocellulose membrane.Results:The lowest detectable serum dilution was 1∶640 for schistosome-infected buffaloes.The cross-reaction rate of GICA was 14.29%with Paramphistomum sp.in buffaloes,16.67%with Haemonchus sp.in goats,and 33.33%with Orientobilharzia sp.in goats.These results were slightly lower and similar to those obtained through ELISA.Moreover,the strips for detecting S.japonicum in mice,rabbits,buffaloes,and goats showed high sensitivity(100.00%,100.00%,100.00%,and 100.00%,respectively)and specificity(100.00%,100.00%,94.23%,and 88.64%,respectively).And the sensitivity or specificity of the GICA strips did not present any significant differences after storage for 12 months at room temperature.When compared with ELISA,the GICA strips exhibited similar sensitivity and specificity in the diagnosis of schistosomiasis in mice,rabbits,buffaloes,and goats.Besides,only 5μl of serum are required for the test and the detection can be completed within 5 min.Conclusion:This study is the first to develop a GICA strip using gold-rSPG conjugate for the diagnosing of schistosomiasis in domestic animals,and preliminary results showed that the developed strip may be suitable for large-scale screening of schistosomiasis in endemic areas.