期刊文献+
共找到30,867篇文章
< 1 2 250 >
每页显示 20 50 100
Burden of routine orthopedic implant removal a single center retrospective study
1
作者 Ammar K AlOmran Nader Alosaimi +6 位作者 Ahmed A Alshaikhi Omar M Bakhurji Khalid J Alzahrani Basil Ziyad Salloot Tamim Omar Alabduladhem Ahmed I AlMulhim Arwa Alumran 《World Journal of Orthopedics》 2024年第2期139-146,共8页
BACKGROUND Open reduction and internal fixation represent prevalent orthopedic procedures,sparking ongoing discourse over whether to retain or remove asymptomatic implants.Achieving consensus on this matter is paramou... BACKGROUND Open reduction and internal fixation represent prevalent orthopedic procedures,sparking ongoing discourse over whether to retain or remove asymptomatic implants.Achieving consensus on this matter is paramount for orthopedic surgeons.This study aims to quantify the impact of routine implant removal on patients and healthcare facilities.A retrospective analysis of implant removal cases from 2016 to 2022 at King Fahad Hospital of the University(KFHU)was conducted and subjected to statistical scrutiny.Among these cases,44%necessitated hospitalization exceeding one day,while 56%required only a single day.Adults exhibited a 55%need for extended hospital stays,contrasting with 22.8%among the pediatric cohort.The complication rate was 6%,with all patients experiencing at least one complication.Notably,34.1%required sick leave and 4.8%exceeded 14 d.General anesthesia was predominant(88%).Routine implant removal introduces unwarranted complications,particularly in adults,potentially prolonging hospitalization.This procedure strains hospital resources,tying up the operating room that could otherwise accommodate critical surgeries.Clearly defined institutional guidelines are imperative to regulate this practice.AIM To measure the burden of routine implant removal on the patients and hospital.METHODS This is a retrospective analysis study of 167 routine implant removal cases treated at KFHU,a tertiary hospital in Saudi Arabia.Data were collected in the orthopedic department at KFHU from February 2016 to August 2022,which includes routine asymptomatic implant removal cases across all age categories.Nonroutine indications such as infection,pain,implant failure,malunion,nonunion,restricted range of motion,and prominent hardware were excluded.Patients who had external fixators removed or joints replaced were also excluded.RESULTS Between February 2016 and August 2022,360 implants were retrieved;however,only 167 of those who met the inclusion criteria were included in this study.The remaining implants were rejected due to exclusion criteria.Among the cases,44%required more than one day in the hospital,whereas 56%required only one day.55%of adults required more than one day of hospitalization,while 22.8%of pediatric patients required more than one day of inpatient care.The complication rate was 6%,with each patient experiencing at least one complication.Sick leave was required in 34.1%of cases,with 4.8%requiring more than 14 d.The most common type of anesthesia used in the surgeries was general anesthesia(88%),and the mean(SD)surgery duration was 77.1(54.7)min.CONCLUSION Routine implant removal causes unnecessary complications,prolongs hospital stays,depletes resources and monopolizing operating rooms that could serve more critical procedures. 展开更多
关键词 implant removal Healed fracture Orthopedic implant COMPLICATIONS Healthcare system
下载PDF
Graphene-calcium carbonate coating to improve the degradation resistance and mechanical integrity of a biodegradable implant
2
作者 Lokesh Choudhary Parama Chakraborty Banerjee +5 位作者 R.K.Singh Raman Derrek E.Lobo Christopher D.Easton Mainak Majumder Frank Witte Jörg F.Löffler 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期394-404,共11页
Biodegradable implants are critical for regenerative orthopaedic procedures,but they may suffer from too fast corrosion in human-body environment.This necessitates the synthesis of a suitable coating that may improve ... Biodegradable implants are critical for regenerative orthopaedic procedures,but they may suffer from too fast corrosion in human-body environment.This necessitates the synthesis of a suitable coating that may improve the corrosion resistance of these implants without compromising their mechanical integrity.In this study,an AZ91 magnesium alloy,as a representative for a biodegradable Mg implant material,was modified with a thin reduced graphene oxide(RGO)-calcium carbonate(CaCO_(3))composite coating.Detailed analytical and in-vitro electrochemical characterization reveals that this coating significantly improves the corrosion resistance and mechanical integrity,and thus has the potential to greatly extend the related application field. 展开更多
关键词 Graphene coating Biodegradable implant HYDROXYAPATITE Corrosion Magnesium alloy
下载PDF
Peri-implant gas accumulation in response to magnesium-based musculoskeletal biomaterials:Reframing current evidence for preclinical research and clinical evaluation
3
作者 Yu Sun Heike Helmholz Regine Willumeit-Römer 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期59-71,共13页
Historically,the rapid degradation and massive gas release from magnesium(Mg)implants resulted in severe emphysema and mechanical failure.With the advent of new alloys and surface treatment methods,optimized Mg implan... Historically,the rapid degradation and massive gas release from magnesium(Mg)implants resulted in severe emphysema and mechanical failure.With the advent of new alloys and surface treatment methods,optimized Mg implants have re-entered clinics since last decade with reliable performance.However,the optimization aims at slowing down the degradation process,rather than exemption of the gas release.This study involved a systematic evaluation of current preclinical and clinical evidence,regarding the physical signs,symptoms,radiological features,pathological findings and complications potentially associated with peri±implant gas accumulation(PIGA)after musculoskeletal Mg implantation.The literature search identified 196 potentially relevant publications,and 51 papers were enrolled for further analysis,including 22 preclinical tests and 29 clinical studies published from 2005 to 2023.Various Mg-based materials have been evaluated in animal research,and the application of pure Mg and Mg alloys have been reported in clinical follow-ups involving multiple anatomical sites and musculoskeletal disorders.Soft tissue and intraosseous PIGA are common in both animal tests and clinical follow-ups,and potentially associated with certain adverse events.Radiological examinations especially micro-CT and clinical CT scans provide valuable information for quantitative and longitudinal analysis.While according to simulation tests involving Mg implantation and chemical processing,tissue fixation could lead to an increase in the volume of gas cavity,thus the results obtained from ex vivo imaging or histopathological evaluations should be interpreted with caution.There still lacks standardized procedures or consensus for both preclinical and clinical evaluation of PIGA.However,by providing focused insights into the topic,this evidence-based study will facilitate future animal tests and clinical evaluations,and support developing biocompatible Mg implants for the treatment of musculoskeletal disorders. 展开更多
关键词 Magnesium implant Degradation Hydrogen Gas release Postoperative follow-up
下载PDF
HVOF-sprayed HAp/S53P4 BG composite coatings on an AZ31 alloy for potential applications in temporary implants
4
作者 Carlos A.Poblano-Salas John Henao +6 位作者 Astrid L.Giraldo-Betancur Paola Forero-Sossa Diego German Espinosa-Arbelaez Jorge A.González-Sánchez Luis R.Dzib-Pérez Susana T.Estrada-Moo Idelfonso E.Pech-Pech 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期345-360,共16页
Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HA... Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HAp and BG to dissolve and promote osseointegration,considering that both phases have different reaction and dissolution rates under in-vitro conditions.In the present work,75%wt.HAp-25%wt.S53P4 bioactive glass powders were HVOF-sprayed to obtain HAp/S53P4 BG composite coatings on a bioresorbable AZ31 alloy.The study is focused on exploring the effect of the stand-off distance and fuel/oxygen ratio variation as HVOF parameters to obtain stable structural coatings and to establish their effect on the phases and microstructure produced in those coatings.Different characterization techniques,such as scanning electron microscopy,X-ray diffraction,and Fourier transform infrared spectroscopy,were employed to characterize relevant structural and microstructural properties of the composite coatings.The results showed that thermal gradients during coating deposition must be managed to avoid delamination due to the high temperature achieved(max 550℃)and the differences in coefficients of thermal expansion.It was also found that both spraying distance and oxygen/fuel ratio allowed to keep the hydroxyapatite as the main phase in the coatings.In addition,in-vitro electrochemical studies were performed on the obtained HAp/S53P4 BG composite coatings and compared against the uncoated AZ31 alloy.The results showed a significant decrease in hydrogen evolution(at least 98%)when the bioactive coating was applied on the Mg alloy during evaluation in simulated body fluid(SBF). 展开更多
关键词 Coatings Composites Thermal spray Temporary implants Hydrogen evolution
下载PDF
Advances in Wireless,Batteryless,Implantable Electronics for Real‑Time,Continuous Physiological Monitoring
5
作者 Hyeonseok Kim Bruno Rigo +2 位作者 Gabriella Wong Yoon Jae Lee Woon‑Hong Yeo 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期254-302,共49页
This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design co... This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design considerations,such as biological constraints,energy sourcing,and wireless communication,are discussed in achieving the desired performance of the devices and enhanced interface with human tissues.In addition,we review the recent achievements in materials used for developing implantable systems,emphasizing their importance in achieving multi-functionalities,biocompatibility,and hemocompatibility.The wireless,batteryless devices offer minimally invasive device insertion to the body,enabling portable health monitoring and advanced disease diagnosis.Lastly,we summarize the most recent practical applications of advanced implantable devices for human health care,highlighting their potential for immediate commercialization and clinical uses. 展开更多
关键词 implantable electronics Biomedical systems Batteryless devices Wireless electronics Physiological signal monitoring
下载PDF
Implantable Electrochemical Microsensors for In Vivo Monitoring of Animal Physiological Information
6
作者 Jin Zhou Shenghan Zhou +4 位作者 Peidi Fan Xunjia Li Yibin Ying Jianfeng Ping Yuxiang Pan 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期183-211,共29页
In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases.Currently,... In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases.Currently,implantable electrochemical microsensors have emerged as a prominent area of research.These microsensors not only fulfill the technical requirements for monitoring animal physiological information but also offer an ideal platform for integration.They have been extensively studied for their ability to monitor animal physiological information in a minimally invasive manner,characterized by their bloodless,painless features,and exceptional performance.The development of implantable electrochemical microsensors for in vivo monitoring of animal physiological information has witnessed significant scientific and technological advancements through dedicated efforts.This review commenced with a comprehensive discussion of the construction of microsensors,including the materials utilized and the methods employed for fabrication.Following this,we proceeded to explore the various implantation technologies employed for electrochemical microsensors.In addition,a comprehensive overview was provided of the various applications of implantable electrochemical microsensors,specifically in the monitoring of diseases and the investigation of disease mechanisms.Lastly,a concise conclusion was conducted on the recent advancements and significant obstacles pertaining to the practical implementation of implantable electrochemical microsensors. 展开更多
关键词 Electrochemical microsensors implantable sensors In vivo monitoring Animal physiological information
下载PDF
Glaucoma drainage device implantation and cyclophotocoagulation in the management of refractory glaucoma after Descemet-stripping automated endothelial keratoplasty
7
作者 Min-Shu Wang Xue-Chuan Dong +4 位作者 Mi-Yun Zheng Xiang Fan Ge-Ge Xiao Jing Hong Ling-Ling Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期257-264,共8页
AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated en... AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated endothelial keratoplasty(DSAEK).METHODS:This retrospective study on observational case series enrolled 29 patients who underwent DSAEK and posterior anti-glaucoma surgery(15 with GDI and 14 with CPC).The main outcome measures were intraocular pressure(IOP),glaucoma surgery success rate(defined as IOP of 6–21 mm Hg without additional anti-glaucoma operation),number of glaucoma medications,endothelial graft status,and best-corrected visual acuity(BCVA).RESULTS:The mean follow-up time was 34.1 and 21.0mo for DSAEK or glaucoma surgeries,both for the GDI and CPC groups.Both groups showed significant IOP reduction after glaucoma surgery.The GDI group presented a significantly higher success rate in IOP control than the CPC group(60%vs 21.4%,P=0.03).Both procedures significantly decreased the number of glaucoma medications(P=0.03).Forty percent and 57%of cases in the GDI and the CPC group,respectively,experienced endothelial graft failure during follow-up(P=0.36).Significantly worse BCVA after surgery was observed in the CPC group but not in the GDI group.CONCLUSION:Both GDI and CPC significantly decrease IOP in eyes with glaucoma after DSAEK.GDI is preferable to CPC in refractory glaucoma cases after DSAEK,as it manifests a significantly higher success rate for IOP control,similar endothelial graft failure rate,and relatively preserves BCVA than CPC. 展开更多
关键词 glaucoma drainage device implantation CYCLOPHOTOCOAGULATION refractory glaucoma Descemetstripping automated endothelial keratoplasty
原文传递
Embryo Transfer Strategies for Women with Recurrent Implantation Failure During the Frozen-thawed Embryo Transfer Cycles:Sequential Embryo Transfer or Double-blastocyst Transfer?
8
作者 Qiao-hang ZHAO Yu-wei SONG +8 位作者 Jian CHEN Xiang ZHOU Ji-lai XIE Qiu-ping YAO Qi-yin DONG Chun FENG Li-ming ZHOU Wei-ping FU Min JIN 《Current Medical Science》 SCIE CAS 2024年第1期212-222,共11页
Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of Se... Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of SeET and DBT on pregnancy outcomes.Methods Totally,261 frozen-thawed embryo transfer cycles of 243 RIF women were included in this multicenter retrospective analysis.According to different embryo quality and transfer strategies,they were divided into four groups:group A,good-quality SeET(GQ-SeET,n=38 cycles);group B,poor-quality or mixed-quality SeET(PQ/MQ-SeET,n=31 cycles);group C,good-quality DBT(GQ-DBT,n=121 cycles);and group D,poor-quality or mixed-quality DBT(PQ/MQ-DBT,n=71 cycles).The main outcome,clinical pregnancy rate,was compared,and the generalized estimating equation(GEE)model was used to correct potential confounders that might impact pregnancy outcomes.Results GQ-DBT achieved a significantly higher clinical pregnancy rate(aOR 2.588,95%CI 1.267–5.284,P=0.009)and live birth rate(aOR 3.082,95%CI 1.482–6.412,P=0.003)than PQ/MQ-DBT.Similarly,the clinical pregnancy rate was significantly higher in GQ-SeET than in PQ/MQ-SeET(aOR 4.047,95%CI 1.218–13.450,P=0.023).The pregnancy outcomes of GQ-SeET were not significantly different from those of GQ-DBT,and the same results were found between PQ/MQ-SeET and PQ/MQ-DBT.Conclusion SeET relative to DBT did not seem to improve pregnancy outcomes for RIF patients if the embryo quality was comparable between the two groups.Better clinical pregnancy outcomes could be obtained by transferring good-quality embryos,no matter whether in SeET or DBT.Embryo quality plays a more important role in pregnancy outcomes for RIF patients. 展开更多
关键词 recurrent implantation failure sequential embryo transfer frozen-thawed embryo transfer embryo transfer strategies
下载PDF
Baerveldt glaucoma implant with Supramid© ripcord stent in neovascular glaucoma: a case series
9
作者 Yuen Keat Gan Shiivaa Manjare Birapadian +1 位作者 Muhammad Irfan Abdul Jalal Norshamsiah Md Din 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期265-271,共7页
AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripco... AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripcord stent in patients with NVG.No tube ligation or venting slits were performed.Supramid was removed after 3mo if the target intraocular pressure(IOP)was not achieved.Surgical success was defined as IOP≤21 mm Hg with(qualified success)or without IOP-lowering medications(complete success).RESULTS:Twenty-six eyes from 24 patients were included in the study.The median duration of follow-up was 4[interquartile range(IQR)=1-5]y,ranging from 0.5 to 5y.IOP decreased by a mean of 24.2 mm Hg(59.7%);from a mean of 40.5±12.6 mm Hg at baseline to 16.3±11.9 mm Hg,P≤0.001.The number of glaucoma medications reduced from a median of 5(IQR=5-6)to 1(IQR=0-2,P≤0.001)at the final follow-up.Overall success rates were 88.0%at 1y,34.8%at 3y,66.7%at 4y,and 50%at 5y.Hypertensive phase(HP)in the first 3mo occurred in 15/26 eyes(57.7%)with a mean IOP of 31.1 mm Hg.CONCLUSION:BGI with Supramid©ripcord stent gives close to 90%of the overall survival rate at the final follow-up without significant early hypotony.However,early HP is still a challenge. 展开更多
关键词 neovascular glaucoma Supramid ripcord stent Baerveldt glaucoma implant
原文传递
Rhegmatogenous retinal detachment in highly myopic eyes with implantable collamer lens
10
作者 Jun Li Chong-Lin Chen +2 位作者 Jia-Qing Li Xiao-Ling Liang Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期392-396,共5页
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv... AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes. 展开更多
关键词 high myopia implantable collamer lens rhegmatogenous retinal detachment
原文传递
Current knowledge for the risk factors of early permanent pacemaker implantation following transcatheter aortic valve replacement and what is next for the primary prevention?
11
作者 Gen-Min Lin Wei-Chun Huang Chih-Lu Han 《World Journal of Cardiology》 2024年第2期54-57,共4页
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from... In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR. 展开更多
关键词 Permanent pacemaker implantation Transcatheter aortic valve replacement Interventricular conduction delay DIABETES Supraventricular arrhythmia
下载PDF
Analysis of acupoint massage combined with touch on relieving anxiety and pain in patients with oral implant surgery
12
作者 Jin-Hong Qu Cheng-Cheng Shou +2 位作者 Xin He Qin Wang Yue-Xia Fang 《World Journal of Psychiatry》 SCIE 2024年第4期533-540,共8页
BACKGROUND Oral implant surgery is an effective procedure for artificial implants in missing tooth areas under local anesthesia.Because patients under local anesthesia are conscious during this procedure,compared with... BACKGROUND Oral implant surgery is an effective procedure for artificial implants in missing tooth areas under local anesthesia.Because patients under local anesthesia are conscious during this procedure,compared with general anesthesia-related operations,they are more likely to experience negative emotions,such as anxiety and tension.These emotional reactions result in shivering and chills in the limbs,leading to poor doctor-patient cooperation and even avoidance of treatment.In traditional Chinese medicine,it is believed that acupoint massage regulates blood and Qi,dredge menstruation,and relieve pain,which is beneficial for patients’emotional adjustment;however,there are few related clinical studies.AIM To observe the changes in anxiety and pain in patients with oral implant after acupoint massage combined with touch therapy.METHODS One hundred patients undergoing oral implantation in our hospital between May 2020 and May 2023 were randomly divided into control and study groups,according to a random number table,with 50 patients in each group.The control group received routine intervention,and the study group received acupoint massage combined with touch on the basis of the control group.Anxiety[assessed using the Modified Dental Anxiety Scale(MDAS)],pain severity,blood pressure,heart rate,and satisfaction were compared between the two groups.RESULTS Before intervention,the difference in MDAS score between the two groups was not significant(P>0.05),while after the intervention,the MDAS scores decreased in both groups compared with those before the intervention(P<0.05);the MDAS score of the study group was lower than that of the control group,with a statistically significant difference(P<0.05).The degree of pain in the intervention group was significantly lower than that in the control group(P<0.05).Before the intervention,there were no significant differences in systolic and diastolic blood pressures or heart rate between the two groups(P>0.05).The systolic and diastolic blood pressures and heart rate in the intervention group,during and after the intervention,were significantly lower than those in the control group(P<0.05).The total degree of satisfaction in the study group was significantly higher than that in the control group(P<0.05).CONCLUSION Acupoint massage combined with touch better relieves anxiety and pain in patients undergoing dental implant surgery,improving the perioperative comfort of these patients and ensuring safety and a smooth operation. 展开更多
关键词 Oral implant Acupoint massage TOUCH ANXIETY Degree of pain
下载PDF
Nursing Care and Causative Analysis of Grade IV Capsular Contracture Following Breast Cancer Expander Implantation
13
作者 Rong Chen Nan Zhang Huiting Zhang 《Advances in Breast Cancer Research》 CAS 2024年第1期1-9,共9页
Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reason... Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reasons for the formation of capsular contracture after Stage I expander implantation and prevent its recurrence following Stage II reconstruction. Methods: In May 2020, the patient noticed an increase in the size of a breast mass. In August, she underwent AC-THP neoadjuvant chemotherapy, followed by a “right breast-conserving nipple-areolar subglandular excision + right axillary lymph node dissection + expander implantation” surgery in November 2020. Radiation therapy began in January 2021. During radiation therapy, the patient experienced severe breast hardening, distortion, tenderness, and was diagnosed with Grade IV capsular contracture. To relieve the capsular contracture, the patient underwent a “contracted capsule incision and release procedure + removal of the right breast expander + right breast implantation” surgery in July 2021. Postoperatively, measures were taken to prevent incision infection, emphasizing aseptic techniques, ensuring smooth negative pressure drainage, reducing skin flap tension, monitoring skin flap blood supply, actively preventing subcutaneous effusion and hematoma, and applying appropriate compression dressings. Results: The patient was discharged after the removal of the drainage tube. During the postoperative follow-up at 3 and 6 months, there was no recurrence of capsular contracture, and the breast appeared full, upright, and relatively soft. There were no complications such as hematoma, infection, breast implant rupture, breast sagging, or displacement. The patient had a good outcome without additional financial or surgical burdens. Conclusion: The occurrence of Grade IV capsular contracture in the patient is generally related to infection after Stage I expander implantation, improper compression dressing, excessive saline injection causing content infiltration, and radiation therapy. Therefore, it is recommended to enhance the intraoperative and postoperative prophylactic use of antibiotics after Stage I expander implantation. Intermittent saline injection after surgery, with the amount of saline gradually increasing rather than filling all at once, is advisable. This helps the breast tissue gradually adapt to expansion, reducing the risk of capsular contracture. Postoperatively, patients should be instructed to wear pressure garments and breast elastic bandages while intensifying breast monitoring during radiation therapy and increasing postoperative follow-up. 展开更多
关键词 Breast Cancer Capsular Contracture Expander implantation
下载PDF
Effects of Continuous Precision Nursing Model on Knowledge, Attitudes, and Practices (KAP) Behavior and Cardiac Function in Patients after Percutaneous Coronary Angiography and Stent Implantation
14
作者 Cuiying Han 《Journal of Clinical and Nursing Research》 2024年第3期1-6,共6页
Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary a... Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary angiography and stent implantation.Methods:Ninety patients who underwent percutaneous coronary angiography and stent implantation in our hospital from April 2022 to April 2023 were selected and randomly divided into the control group(45 cases),in which routine nursing support was carried out during the treatment process,and the observation group(45 cases),in which continuous precision nursing model was carried out during the treatment process.Comparisons were made between the two groups of patients on their KAP,cardiac function,and quality of life during recovery.Results:There was no difference in the left ventricular ejection fraction(LVEF),cardiac output(CO),and cardiac index(CI)levels before intervention.After the intervention,the levels of cardiac function in the observation group were higher than those of the control group(P<0.05).There was no difference in the Exercise of Self-Care Agency(ESCA)self-care ability scale scores before the intervention.After the intervention,the observation group had higher ESCA scores than the control group(P<0.05).Conclusion:Implementation of a continuous precision nursing model in the care of patients undergoing percutaneous coronary angiography and stent implantation improved the patient’s cardiac function,and KAP,and promoted recovery. 展开更多
关键词 Continuous precision nursing model Percutaneous coronary angiography Stent implantation Knowledge attitudes and practices(KAP) Cardiac function
下载PDF
Impact of central venous port implantation method and access choice on outcomes
15
作者 Ayhan Erdemir Huseyin Kemal Rasa 《World Journal of Clinical Cases》 SCIE 2023年第1期116-126,共11页
BACKGROUND Although the number of patients who need central venous ports for permanent vascular access is increasing,there is still no“gold standard”for the implantation technique.AIM To identify the implantation te... BACKGROUND Although the number of patients who need central venous ports for permanent vascular access is increasing,there is still no“gold standard”for the implantation technique.AIM To identify the implantation technique that should be favored.METHODS Two hundred central venous port-implanted patients in a tertiary hospital were retrospectively evaluated.Patients were assigned into two groups according to the access method.The first group comprised patients whose jugular veins were used,and the second group comprised patients whose subclavian veins were used.Groups were evaluated regarding age,sex,application side,primary diagnosis,active follow-up period in the hospital,chemotherapy agents administered,number of complications,and the Clavien-Dindo severity score.The distribution of the variables was tested with the Kolmogorov-Smirnov test and the Mann-Whitney U test.Theχ^(2) test was used to analyze the variables.RESULTS There was no statistically significant difference between the groups regarding age,sex,side,number of chemotherapy drugs,and duration of port usage(P>0.05).Only 2 patients in group 1 had complications,whereas in group 2 we observed 19 patients with complications(P<0.05).No port occlusion was found in group 1,but the catheters of 4 patients were occluded in group 2.One port was infected in group 1 compared to three infected ports in group 2.Two port ruptures,two pneumothorax,one revision due to a mechanical problem,one tachyarrhythmia during implantation,and four suture line problems were also recorded in group 2 patients.We also showed that it would be sufficient to evaluate and wash ports once every 2 mo.CONCLUSION Our results robustly confirm that the jugular vein route is safer than the subclavian vein approach for central venous port implantation. 展开更多
关键词 Permanent vascular access Central venous ports Central venous port implantation methods Jugular vein route Subclavian vein approach Impact of implantation method on outcomes
下载PDF
Stages of Emotional Experience of Parents of Children with Cochlear Implantation (CI)
16
作者 Iuliia Khomiakova 《Open Journal of Medical Psychology》 2023年第4期231-238,共8页
Rehabilitation is a set of measures aimed at compensating or fully restoring the functions of the patient impaired by the disease. In the rehabilitation of children with a cochlear implant, a comprehensive, systematic... Rehabilitation is a set of measures aimed at compensating or fully restoring the functions of the patient impaired by the disease. In the rehabilitation of children with a cochlear implant, a comprehensive, systematic approach is essential in the work of doctors, teachers, sign language teachers, psychologists, and families. Rehabilitation and social adaptation of children with a cochlear implant depend not only on specialists but also on the ability of parents to help the child organize educational activities in an optimistic mood and the ability to provide emotional support. This means that the role of parents in the way to successful rehabilitation is high, and therefore this topic is especially relevant today. . 展开更多
关键词 Emotions during the Rehabilitation Children with a Cochlear implantation Rehabilitation Process Parents of Children with Cochlear implantation (CI)
下载PDF
Comparative Cytological and Histopathological Study of Peri-Implantitis and Periodontitis
17
作者 Masaaki Suemitsu Yoshikazu Nakayama +3 位作者 Mao Yamamoto Mitsuko Nakayama Tadahiko Utsunomiya Kayo Kuyama 《Open Journal of Stomatology》 2023年第11期385-395,共11页
Peri-implant diseases, such as peri-implant mucositis and peri-implantitis, pose significant challenges to the long-term prognosis of dental implants. This study aimed to comprehensively compare peri-implantitis with ... Peri-implant diseases, such as peri-implant mucositis and peri-implantitis, pose significant challenges to the long-term prognosis of dental implants. This study aimed to comprehensively compare peri-implantitis with periodontitis from cytological and histopathological perspectives, shedding light on the morphological characteristics associated with peri-implantitis. Thirteen patients, including six with peri-implantitis and seven with periodontitis, were included in the study. Cytological examination of affected gingival mucosa revealed distinct differences between the two conditions. Peri-implantitis exhibited an inflammatory background predominantly composed of neutrophils with lobulated nuclei, accompanied by stratified squamous epithelial cells showing signs of keratinization. In contrast, periodontitis showed a similar neutrophilic inflammatory background but with non-keratinized epithelial cells. Histopathological examination further confirmed these differences, with peri-implantitis showing keratinized epithelium in the inner epithelial layer. This histological finding aligns with the notion that peri-implantitis has a distinct mucosal profile compared to periodontitis. Additionally, cytological analysis revealed that peri-implantitis had a lower occurrence rate of Light green-positive cells, indicating a tendency toward keratinization. This finding suggests that the presence of keratinized mucosa might be associated with peri-implant health, although further research is needed to clarify this relationship. Overall, this study demonstrates the potential of cytological examination and Papanicolaou staining for assessing mucosal inflammatory conditions and distinguishing between keratinized and non-keratinized cells. These findings underscore the utility of oral mucosal smears as a valuable tool for diagnosing peri-implantitis and enhancing our understanding of its pathogenesis. 展开更多
关键词 Peri-implant Disease PERI-implantITIS Oral Cytology
下载PDF
Investigation of Bacteria Species Most Involved in Peri-Implantitis
18
作者 Hiroshi Murakami Osamu Tsuzukibashi +12 位作者 Akira Fukatsu Yuji Takahashi Keisuke Idei Keisuke Usuda Mana Fuchigami Chiaki Komine Satoshi Uchibori Koji Umezawa Sachiyo Hayashi Takashi Asano Masanobu Wakami Taira Kobayashi Masahiko Fukumoto 《Open Journal of Stomatology》 2023年第10期353-366,共14页
Purpose: Currently, bacteriological examinations of implant treatments target periodontopathic bacteria such as red complex bacteria, including Porphyromonas gingivalis, and detect them qualitatively or quantitatively... Purpose: Currently, bacteriological examinations of implant treatments target periodontopathic bacteria such as red complex bacteria, including Porphyromonas gingivalis, and detect them qualitatively or quantitatively. However, it seems that those examinations do not reflect the peri-implant tissue conditions precisely, because periodontopathic bacteria are also frequently detected from healthy peri-implant sites. The purpose of the present study was to investigate bacteria species most involved in peri-implantitis using a PCR method. Methods: Polymerase chain reaction (PCR) primers in this study were designed based on partial sequences of 16S rDNA of bacteria species involved in peri-implantitis that were described in numerous previous studies. Peri-implant sulcus fluid (PISF) samples were collected from thirty periodontally healthy patients with implants (HI) and thirty patients with peri-implantitis (PI). Each detection frequency of bacteria species in PISFs of both groups was investigated using a PCR method, and was compared using Fisher’s exact test. Results: In PI group, detection frequencies of Corynebacterium durum, Fretibacterium fastidiosum and Slackia exigua were significantly higher than those of HI group (p P. gingivalis and Tannerella forsythia belonging to red complex were frequently detected in the PISF samples of HI group (p > 0.05). Conclusion: It was suggested that monitoring C. durum and F. fastidiosum levels in PISF samples was useful as a clinical indicator for the evaluation of peri-implant tissue conditions. 展开更多
关键词 PERI-implantITIS PCR Method Bacteria Flora in Peri-implant Sulcus Red Complex
下载PDF
Barriers to Early Pediatric Cochlear Implantation in Kenya
19
作者 Irene Wairimu Ndegwa 《International Journal of Otolaryngology and Head & Neck Surgery》 2023年第4期214-231,共18页
Background: Cochlear implantation is the best management option for children with profound hearing loss and has received no benefit from hearing aids. Early implantation for these children is associated with good spee... Background: Cochlear implantation is the best management option for children with profound hearing loss and has received no benefit from hearing aids. Early implantation for these children is associated with good speech and language outcomes. Objectives: To determine the barriers to early pediatric cochlear implantation. Methodology: A qualitative cross-sectional study was conducted at Hearing Implants Centre in Nairobi Kenya from August 2022 to February 2023. The target population was 40 children who had undergone cochlear implantation under the auspices of Cochlear Implant Group of Kenya but data was only collected from 30 of them. The remaining were ruled out because 3 were unreachable over the phone, 5 refused to participate and 2 did not meet the inclusion criteria. Results: Patient file reviews and parental telephone interviews were conducted to collect information and analyzed using Microsoft excel and presented using graphs, tables and pie charts. The analysis of the gender showed 46.67% were male and 53.33% were female. Analysis on newborn screening showed that none had it done. The mode age of hearing loss suspicion was between the ages of 2 - 3 years. The hearing loss suspicion done was done by the mothers at 20 children the reminder being 3 by the father, 1 by a family friend, 4 by the school-teacher and 2 by the child’s grandmother. A total of 17 participants noted a delayed in speech and language, 9 noted that the child did not respond to loud sounds, 4 noted that the children did not turn when called. Once hearing loss was identified, 73% saw the ENT, 17% saw a pediatrician, 7% went to see an Audiologist, and 3% saw a speech therapist. The mode age at diagnosis was 1.5 years. The mode age at implantation was 5 years. The mode time from diagnosis was 2 years. Conclusions: This study sought to investigate the barriers to pediatric cochlear implantation in Kenya. From the results it was determined that factors such as lack of newborn screening, high cost of cochlear implantation, lack of awareness have led to late cochlear implantation. 展开更多
关键词 Cochlear implants PEDIATRIC Barriers Newborn Hearing Screening Early implantation
下载PDF
Postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens implantation versus small incision lenticule extraction in myopic eyes:a Meta-analysis 被引量:2
20
作者 Hong-Yu Li Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期442-452,共11页
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W... AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group. 展开更多
关键词 implantable collamer lens small incision lenticule extraction MYOPIA refractive surgery META-ANALYSIS
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部