期刊文献+
共找到91篇文章
< 1 2 5 >
每页显示 20 50 100
Assessing mixing uniformity in microreactors via in-line spectroscopy
1
作者 Shusaku Asano Shinji Kudo +3 位作者 Taisuke Maki Yosuke Muranaka Kazuhiro Mae Jun-ichiro Hayashi 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第2期119-124,共6页
Mixing behavior is critical for enhancing the selectivity of fast chemical reactions in microreactors.A high Reynolds number(Re)improves the mixing rate and selectivity of the reactions,but some exceptions of increasi... Mixing behavior is critical for enhancing the selectivity of fast chemical reactions in microreactors.A high Reynolds number(Re)improves the mixing rate and selectivity of the reactions,but some exceptions of increasing side product yield with the higher Re have been reported.This study investigated the mixing uniformity in microreactors with in-line UV-vis spectroscopy to clarify the relationship between reaction selectivity and chaotic mixing with the higher Re.A colorization experiment of thymolphthalein in an acidic solution was conducted with an excess acid amount to the base to indicate a non-uniformly mixed region.Non-uniformity significantly increased with Re.At the same time,the degree of mixing,which was measured by a usual decolorization experiment,showed that the mixing rate increased with Re.The in-line analysis of the Villermaux-Dushman reaction during the mixing clarified that side product yield significantly increased with Re at around 300 and then decreased at around 1100.These results suggest the compensation effect between the mixing uniformity and mixing rate on the selectivity of the mixing-sensitive reactions.Faster mixing,characterized by a larger Re,can disturb mixing uniformity and,in some cases,decrease reaction selectivity. 展开更多
关键词 MICROREACTOR Villermaux-Dushman reaction in-line analysis MIXING Mass transfer UNIFORMITY
下载PDF
Experimental Study on Coupled Cross-Flow and in-Line Vortex-Induced Vibration of Flexible Risers 被引量:9
2
作者 郭海燕 娄敏 《China Ocean Engineering》 SCIE EI 2008年第1期123-129,共7页
In this work, we study the coupled cross-flow and in-line vortex-induced vibration (VIV) of a fixedly mounted flexible pipe, which is free to move in cross-flow ( Y- ) and in-line ( X- ) direction in a fluid flo... In this work, we study the coupled cross-flow and in-line vortex-induced vibration (VIV) of a fixedly mounted flexible pipe, which is free to move in cross-flow ( Y- ) and in-line ( X- ) direction in a fluid flow where the mass and natural frequencies are precisely the same in both X- and Y-direction. The fluid speed varies from low to high with the corresponding vortex shedding frequency varying from below the first natural frequency to above the second natural frequency of the flexible pipe. Particular emphasis was placed on the investigation of the relationship between in-line and cross-flow vibration. The experimental results analyzed by using these measurements exhibits several valuable features. 展开更多
关键词 flexible riser vortex-induced vibration cross-flow vibration in-line vibration
下载PDF
The prediction on in-line vortex-induced vibration of slender marine structures 被引量:7
3
作者 Wan-Hai Xu Xi-Feng Gao Jie Du 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2012年第5期1303-1308,共6页
The in-line (IL) vortex-induced vibration (VIV) that occurs frequently in ocean engineering may cause severe fatigue damage in slender marine structures. To the best knowledge of the authors, in existing literatur... The in-line (IL) vortex-induced vibration (VIV) that occurs frequently in ocean engineering may cause severe fatigue damage in slender marine structures. To the best knowledge of the authors, in existing literatures, there is no efficient analytical model for predicting pure IL VIV. In this paper, a wake oscillator model capable of analyzing the IL VIV of slender marine structures has been developed. Two different kinds of van der Pol equations are used to describe the near wake dynamics related to the fluctuating nature of symmetric vortex shedding in the first excitation region and alternate vortex shedding in the second one. Some comparisons are carried out between the present model results and experimental data. It is found that many phenomena observed in experiments could be reproduced by the present wake oscillator model. 展开更多
关键词 Vortex-induced vibration Wake oscillatormodel in-line Slender marine structures
下载PDF
Ultrafiltration with in-line coagulation for the removal of natural humic acid and membrane fouling mechanism 被引量:10
4
作者 WANG Jin WANG Xiao-chang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第5期880-884,共5页
Experimental and theoretical analysis were made on the natural humic acid removal and the membrane fouling of ultrafiltration (UF) with in-line coagulation. The results showed dissolved organic carbon (DOC) and UV... Experimental and theoretical analysis were made on the natural humic acid removal and the membrane fouling of ultrafiltration (UF) with in-line coagulation. The results showed dissolved organic carbon (DOC) and UV254 removals by the UF with in-line coagulation at pH 7 were increased from 28% to 53% and 40% to 78% in comparison with direct UF treatment respectively. At the same time, the analysis of high performance liquid chromatography showed that UF with coagulation had significant improvement of removal of humic acid with molecular weights less than 6000 Da in particular. Compared to direct UF, the in-line coagulation UF also kept more constant permeate flux and very slight increase oftransmembrane pressure during a filtration circle. Two typical membrane fouling models were used by inducing two coefficients Kc and Kp corresponding to cake filtration model and pore narrowing model respectively. It was found that membrane fouling by pore-narrowing effect was effectively alleviated and that by cake-filtration was much decreased by in-line coagulation. Under the condition of coagulation prior to ultrafiltration at pH 7, the cake layer formed on the membrane surface became thicker, but the membrane filtration resistance was lower than that at pH 5 with the extension of operation time. 展开更多
关键词 natural humic acid ultrafiltration (UF) in-line coagulation high performance liquid chromatography (HPLC) membrane fouling
下载PDF
In-line response of vertical cylinders in regular and random waves 被引量:2
5
作者 LI Yok-sheung SU Wei +1 位作者 ZHAN Jiemin ZHAN Sheng 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2007年第6期124-138,共15页
The in-line response of a vertical flexibly mounted cylinder in regular and random waves is reported. Both theoretical analyses and experimental measurements have been performed. The theoretical predictions are based ... The in-line response of a vertical flexibly mounted cylinder in regular and random waves is reported. Both theoretical analyses and experimental measurements have been performed. The theoretical predictions are based on the Morison equation which is solved by the incremental harmonic balance method. Experiments are then performed in a wave flume to determine the accuracy of the Morison equation in predicting the in-line response of the cylinder in regular and random waves. The interaction between waves and vibrating cylinders are investigated. 展开更多
关键词 in-line response CYLINDER WAVES IHB method
下载PDF
Three-axis magnetic flux leakage in-line inspection simulation based on finite-element analysis 被引量:4
6
作者 冯健 张峻峰 +2 位作者 卢森骧 王宏阳 马瑞泽 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第1期531-536,共6页
With the increase of pipelines, corrosion leakage accidents happen frequently. Therefore, nondestructive testing technology is important for ensuring the safe operation of the pipelines and energy mining. In this pape... With the increase of pipelines, corrosion leakage accidents happen frequently. Therefore, nondestructive testing technology is important for ensuring the safe operation of the pipelines and energy mining. In this paper, the structure and principle of magnetic flux leakage (MFL) in-line inspection system is introduced first. Besides, a mathematic model of the system according to the ampere circuit rule, flux continuity theorem, and column coordinate transform is built, and the magnetic flux density in every point of space is calculated based on the theory of finite element analysis. Then we analyze and design the disposition of measurement section probes and sensors combining both three-axis MFL in-line inspection and multi-sensor fusion technology. Its advantage is that the three-axis changes of magnetic flux leakage field are measured by the multi-probes at the same time, so we can determine various defects accurately. Finally, the theory of finite element analysis is used to build a finite element simulation model, and the relationship between defects and MFL inspection signals is studied. Simulation and experiment results verify that the method not only enhances the detection ability to different types of defects but also improves the precision and reliability of the inspection system. 展开更多
关键词 magnetic flux leakage in-line inspection multi-sensor data fusion sensor disposition finite element analysis
原文传递
Nonlinear Coupled in-Line and Cross-Flow Vortex-Induced Vibration Analysis of Top Tensioned Riser 被引量:4
7
作者 李效民 郭海燕 孟凡顺 《China Ocean Engineering》 SCIE EI 2010年第4期749-758,共10页
The fluctuating furces of the fluid exerted on the top terrsioned riser ('FIR) in the in-line and cross-flow directions are both modeled by van del Pol wake oscillator model and the nonlinear coupled dynamics of th... The fluctuating furces of the fluid exerted on the top terrsioned riser ('FIR) in the in-line and cross-flow directions are both modeled by van del Pol wake oscillator model and the nonlinear coupled dynamics of the in-line and cross-flow vortex-induced vibrations (VIV) of the riser are analyzed in time domain in this papar. The numencal shnulation results of the riser's in-line and cross-flow displacements and curvatures are compared with experimental measurements and the comparison shows the validity of this method in modeling some main features of the riser's VIV. Finally, the effects of the riser's top tensions and internal flow velocities on the coupled vibrations of the riser are investigated. 展开更多
关键词 top tensioned riser (TFR) vortex-induced vibration (VIV) wake oscillator model in-line and cross-flowvibration
下载PDF
Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts 被引量:1
8
作者 冀东江 渠刚荣 +3 位作者 胡春红 刘宝东 简建波 郭晓坤 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第6期93-100,共8页
In-line phase-contrast computed tomography(IL-PC-CT) imaging is a new physical and biochemical imaging method.IL-PC-CT has advantages compared to absorption CT when imaging soft tissues. In practical applications, r... In-line phase-contrast computed tomography(IL-PC-CT) imaging is a new physical and biochemical imaging method.IL-PC-CT has advantages compared to absorption CT when imaging soft tissues. In practical applications, ring artifacts which will reduce the image quality are commonly encountered in IL-PC-CT, and numerous correction methods exist to either pre-process the sinogram or post-process the reconstructed image. In this study, we develop an IL-PC-CT reconstruction method based on anisotropic total variation(TV) minimization. Using this method, the ring artifacts are corrected during the reconstruction process. This method is compared with two methods: a sinogram preprocessing correction technique based on wavelet-FFT filter and a reconstruction method based on isotropic TV. The correction results show that the proposed method can reduce visible ring artifacts while preserving the liver section details for real liver section synchrotron data. 展开更多
关键词 SART anisotropic TV in-line phase-contrast
原文传递
Determination of inorganic anions in ethyl acetate by in-line hollow fiber membrane extraction with ion chromatography 被引量:1
9
作者 Zhen Zhen Hu Ying Ying Zhong Yun Chang Fan Yan Zhu 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第12期1498-1501,共4页
In this work, a novel hollow fiber membrane extractor was set up to extract inorganic anions from ethyl acetate using deionized water. Inorganic anions in slightly soluble organic solvents can be determined by the in-... In this work, a novel hollow fiber membrane extractor was set up to extract inorganic anions from ethyl acetate using deionized water. Inorganic anions in slightly soluble organic solvents can be determined by the in-line hollow fiber membrane extractor coupled with ion chromatography at first time. Different aspects of the extraction procedure such as magnetic stirring speed, extraction flow rate and extraction time were optimized to achieve high extraction efficiency and good separation results. Satisfactory linear range, limits of detection and good repeatability were obtained. The procedure was applied to analyze inorganic anions in two commercial ethyl acetate samples. 展开更多
关键词 Inorganic anions Ethyl acetate in-line hollow fiber membrane extraction Ion chromatography
下载PDF
STUDY ON AUTOMATIC IN-LINE MEASUREMENT OF FeO CONTENT IN AGGLOMERATE
10
作者 王明阳 陈前平 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 1995年第3期53-57,共5页
In this paper, the mechanism of physical method for measuring the FeO content in agglomerate replacing the chemical method is proposed after studying the electromagnetic property of the agglomerate. The microcomputer-... In this paper, the mechanism of physical method for measuring the FeO content in agglomerate replacing the chemical method is proposed after studying the electromagnetic property of the agglomerate. The microcomputer-measuring system for FeO content is provided. Attention is also paid to introducing the working principle of the H-type compensation sensor and the processing method of the measured data. This system has been successfully applied in practice to in-line measure the FeO content. 展开更多
关键词 AGGLOMERATE FeO content in-line measurement SENSOR
下载PDF
In-line phase contrast for weakly absorbing materials with a microfocus x-ray source
11
作者 章迪 李政 +2 位作者 黄志峰 禹爱民 沙薇 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第8期1731-1737,共7页
For weakly absorbing materials, image contrast can be enhanced by phase contrast in formation. The effectiveness of the in-line phase contrast technique relies on its ability to record intensity data which contain inf... For weakly absorbing materials, image contrast can be enhanced by phase contrast in formation. The effectiveness of the in-line phase contrast technique relies on its ability to record intensity data which contain information on the x- ray's phase shift. Four kinds of approaches to the relationship between intensity distribution and phase shift axe reviewed and discussed. A micro-focal x-ray source with high geometrical magnification is used to acquire phase contrast images. A great improvement on image quality is shown and geometrical parameters axe modified for comparison between different imaging positions. 展开更多
关键词 in-line phase contrast intensity distribution MICROFOCUS Fresnel diffraction
原文传递
Large Eddy Simulation on Interaction Between in-Line and Cross-Flow Oscillation of A Circular Cylinder
12
作者 黄智勇 Carl M.LARSEN 《China Ocean Engineering》 SCIE EI 2010年第4期663-676,共14页
This paper discusses numerical results from three-dimensional large eddy simulations of an oscillating cylinder under prescribed movements in uniform flow. Six cases, namely pure in-line, pure cross-flow and two group... This paper discusses numerical results from three-dimensional large eddy simulations of an oscillating cylinder under prescribed movements in uniform flow. Six cases, namely pure in-line, pure cross-flow and two groups of 'Figure of Eight' oscillation patterns are under investigation at Reynolds number Re = 24000. The ' Figure of Eight' pattern in each group is with identical shape but oppusite orbital directions. The numerical results on hydrodynamic forces, higher order force components, and vortex shedding modes are extensively studied and compared with the measured experimental data. It is found that the fluid force in phase with the velocity, which represents the energy transfer between the fluid and the cylinder, has opposite sign and different magnitude due to the opposite orbital direction. Higher order force components in cross-flow direction are found to occur at odd nmnber times of the oscillating frequency, while even nmbers dominate the higher order force components in in-llne direction. The 2C and 2T vortex shedding modes are well reproduced due to the opposite orbital direction effect. Comparisons between numerical and experimental results indicate that the present numerical model could be a rational tool for the identification of hydrodynamic coefficients which are normally applied in empirical models to predict the vortex-induced vibrations of slender marine structures. 展开更多
关键词 vortex-ivduced vibration large eddy simulation forced oscillation in-line CROSS-FLOW
下载PDF
Influence of tube voltage and current on in-line phase contrast imaging using a microfocus x-ray source
13
作者 李晨 李政 +1 位作者 禹爱民 黎成权 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第8期2319-2324,共6页
In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehens... In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging. 展开更多
关键词 X-RAY in-line phase contrast imaging Wigner distribution
原文传递
Design of in-line multipoint initiation control system
14
作者 李守殿 袁士伟 曾庆轩 《Journal of Beijing Institute of Technology》 EI CAS 2011年第3期306-311,共6页
In order to improve the power of initiating explosive warheads, besides exploring new type of high explosive, multipoint initiation technology becomes the research focus. With research on electronic safety and arming ... In order to improve the power of initiating explosive warheads, besides exploring new type of high explosive, multipoint initiation technology becomes the research focus. With research on electronic safety and arming devices (ESADs), pulse power devices and slapper detonators, a hardware control circuit was designed for multipoint initiation control system based on complex programmable logic device ( CPLD ). In addition, a real-time monitoring interface based on virtual instru- ments technology was designed by the prevailing software of Laboratory Virtual Instrument Engineer- ing Workbench (LabVIEW). It provides users a real-time status of the hardware circuit system. Mo- reover, a series of experiments were done on the software and hardware platform. The results show that the signals transmission, collection, analysis and display can be realized reliably through a serial port line. It is verified that using a serial bus controller for multiple initiators is reasonable. Successful design of the platform will play an important foundation for the theory and engineering of the fu- ture weapon system. Surely, it will become one of the development directions for intelligent initia- tion system. 展开更多
关键词 multipoint initiation control system in-line electronic safety and arming virtual instrument
下载PDF
Hard X-ray in-line outline imaging for blood vessels:first generation synchrotron radiation without contrast agents in vitro
15
作者 姜庆军 冯赟 +5 位作者 肖湘生 刘士远 陈敏 肖体乔 田玉莲 朱佩平 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第1期34-37,共4页
Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study in... Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents. 展开更多
关键词 hard X-ray in-line outline imaging X-ray phase-contrast imaging blood vessels imaging synchrotron radiation
下载PDF
Interactions between two in-line drops rising in pure glycerin
16
作者 Li Rao Zhengming Gao +1 位作者 Ziqi Cai Yuyun Bao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第10期1325-1334,共10页
The behaviors of time-dependent interaction between two buoyancy-driven in-line deformable drops rising in pure glycerin at Re 〈 1 were studied, where the diameter for the leading drops ranged from 9.51 mm to 12.6 mm... The behaviors of time-dependent interaction between two buoyancy-driven in-line deformable drops rising in pure glycerin at Re 〈 1 were studied, where the diameter for the leading drops ranged from 9.51 mm to 12.6 mm and for trailing drops from 12.7 mm to 15.8 mm. The situation while a larger drop chasing a smaller one was specifically considered which typically led to the smaller drop "coating" the larger one. Two approaches, the geometric feature approach and the energy change one, were used to judge the starting and ending times of the interaction between two drops. Based on a conical wake model, the drag coefficient of two approaching drops was calculated. Due to the approaching effect of the trailing drop, the leading drop was accelerated and the average drag coefficient was smaller than that for a free rising single drop. The frequency spectrums of the lateral oscillation of two drops during the interaction were obtained by using Fourier analysis. The oscillation frequency of the interactional drops was also different from that for a free rising single drop because of the wake effect produced by the leading drop. Due to a superposition of the drop shape oscillation and the drop internal circulation, the transverse oscillation frequencies of two drops have the same trend during the approaching process. 展开更多
关键词 Two in-line drops Oscillation Fourier analysis Energy analysis
下载PDF
Investigate the Impact of Dimple Size and Distribution on the Hydrothermal Performance of Dimpled Heat Exchanger Tubes
17
作者 Abeer H.Falih Basima Salman Khalaf Basim Freegah 《Frontiers in Heat and Mass Transfer》 EI 2024年第2期597-613,共17页
In this study,the primary objective was to enhance the hydrothermal performance of a dimpled tube by addressing areas with low heat transfer compared to other regions.To accomplish this,a comprehensive numerical inves... In this study,the primary objective was to enhance the hydrothermal performance of a dimpled tube by addressing areas with low heat transfer compared to other regions.To accomplish this,a comprehensive numerical investigation was conducted using ANSYS Fluent 2022 R1 software,focusing on different diameters of dimples along the pipe’s length and the distribution of dimples in both in-line and staggered arrangements.The simulations utilized the finite elementmethod to address turbulent flowwithin the tube by solving partial differential equations,encompassing Re numbers spanning from 3000 to 8000.The study specifically examined single-phase flow conditions,with water utilized as the cooling fluid.The results of the investigation indicated that increasing the Reynolds number resulted in higher average Nusselt numbers,pressure drops,the overall performance criterion,and a reduction in average thermal resistance across all models analyzed.Notably,both proposedmodels demonstrated improved heat transfer when compared to the conventional model.Out of all the models evaluated,the tube featuring staggered dimples(Model B)demonstrated the most notable improvement in the Nu number.It exhibited an enhancement of approximately twice the value compared to the conventional model.The mean thermal resistance for the tube with dimples in the staggered arrangement(Model B)is 0.0057 k/W,compared to 0.0118 k/W for the traditional model.The maximum overall performance criterion for Model-A-and Model-Bis 1.22 and 1.33,respectively. 展开更多
关键词 Dimpled tube numerical simulation in-line and staggered arrangements overall performance criterion(OPC)
下载PDF
细纱机短车集聚纺负压系统应用分析
18
作者 闫中旭 陈祖英 《纺织器材》 2024年第4期28-31,共4页
为了提高纱线质量、实现节能降耗,介绍短车集聚纺负压系统的技术要求及主要组成;根据负压主风管结构将集聚纺负压系统分为八边形大风管型、八边形小风管型、上置八边形风管型、上置双列圆风管型,从节电性能、负压平衡度、性价比及对粗... 为了提高纱线质量、实现节能降耗,介绍短车集聚纺负压系统的技术要求及主要组成;根据负压主风管结构将集聚纺负压系统分为八边形大风管型、八边形小风管型、上置八边形风管型、上置双列圆风管型,从节电性能、负压平衡度、性价比及对粗纱架排列要求等方面,详细分析不同类型集聚纺负压主风管的优缺点,并阐述各型集聚纺负压系统的发展应用。指出:上置双列圆风管型集聚纺负压系统节电性能优,支风管车头车尾压差小、负压平衡度好,主风管制造成本低,安装工作量小,使用效果良好。 展开更多
关键词 细纱机 短车 集聚纺 负压系统 主风管 支风管 负压差 粗纱架
下载PDF
Experimental study on the desulfurization and evaporation characteristics of Ca(OH)_(2) droplets
19
作者 Yilin Song Yize Zhang Hao Zhou 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第2期127-135,共9页
The experiments were conducted to focus on the desulfurization and evaporation characteristics of lime slurry droplets at 298-383 K. We designed an evaporation-reaction chamber with quartz glass windows.The monodisper... The experiments were conducted to focus on the desulfurization and evaporation characteristics of lime slurry droplets at 298-383 K. We designed an evaporation-reaction chamber with quartz glass windows.The monodisperse slurry droplet stream was injected into the evaporation reaction chamber, and the inlet gas components(air, air + SO_(2)) were introduced into the chamber. We applied the magnified digital in-line holography to measure the droplet parameters and calculated the evaporation rate. The effects of temperature, droplet concentration, and SO_(2) concentration on the evaporation rate of Ca(OH)_(2) droplets were discussed. Moreover, the Ca(OH)_(2) droplets under different experimental conditions were sampled,and the droplets were observed and analyzed using an off-line microscope. The evaporation rate of the Ca(OH)_(2) droplet increased at first, and then decreased during the falling process, and remained constant at last. The average evaporation rate of the Ca(OH)_(2) droplets increased significantly with the temperature increasing. 展开更多
关键词 Magnified digital in-line holography EVAPORATION Gas–liquid absorption reaction Ca(OH)_(2) Micro-droplet
下载PDF
辽西花岗岩三轴蠕变时效性试验 被引量:5
20
作者 张树光 马涛 王有涛 《辽宁工程技术大学学报(自然科学版)》 CAS 北大核心 2014年第10期1342-1346,共5页
为研究辽西花岗岩的工程力学性能,采用TAW-2000电液伺服岩石三轴仪,对辽西花岗岩试样分别进行了围压为5 MPa、10 MPa和20 MPa条件下的三轴蠕变实验.基于不同围压条件下的三轴蠕变试验数据,绘制辽西花岗岩的三轴蠕变曲线、等时应力应变... 为研究辽西花岗岩的工程力学性能,采用TAW-2000电液伺服岩石三轴仪,对辽西花岗岩试样分别进行了围压为5 MPa、10 MPa和20 MPa条件下的三轴蠕变实验.基于不同围压条件下的三轴蠕变试验数据,绘制辽西花岗岩的三轴蠕变曲线、等时应力应变曲线和蠕变速率曲线,分析试样的蠕变起始应力和长期强度.研究结果表明:等时应力应变与蠕变速率相结合的方法能更好地描述蠕变的发展过程、变形特征和蠕变阶段.随着围压的增加,蠕变速率的波动范围减小,加速蠕变段的发展过程更为平稳,蠕变破坏经历的时间也更长.实验数据的统计分析结果表明:试样的蠕变长期强度阈值为(0.7~0.8)(σ1-σ3). 展开更多
关键词 花岗岩 三轴蠕变 时效性 变性特征 长时强度
原文传递
上一页 1 2 5 下一页 到第
使用帮助 返回顶部