期刊文献+
共找到174,903篇文章
< 1 2 250 >
每页显示 20 50 100
Specific Enthalpy Based Heat Stress Index for Indoor Environments without Radiation Effect 被引量:1
1
作者 刘书晓 刘赟 邹钺 《Journal of Donghua University(English Edition)》 CAS 2022年第2期176-184,共9页
Over 100 human thermal indices have been developed to predict the combined thermal impact on the body.In principle,these indices based on energy thermal budget equations should not only be the most complex but also be... Over 100 human thermal indices have been developed to predict the combined thermal impact on the body.In principle,these indices based on energy thermal budget equations should not only be the most complex but also be the most accurate.However,the simple indices based on algebraic or statistical models[e.g.,the wet-bulb globe temperature(WBGT)]continue to be the most popular.A new heat stress index,the enthalpy dry-bulb temperature(EnD)for indoor environments is developed and validated in this study.The EnD index is unique in that it uses the air specific enthalpy,not the wet-bulb temperature,to measure the latent heat transfer from the skin to the surrounding environment.Theoretically,the EnD index can be treated as the equivalent temperature based on the convective heat transfer coefficient h_(c).Comparison is made between the EnD index and the widely used WBGT index based on the experimental data taken from three independent studies available in the scientific literature.The results show that the EnD index can reduce the overestimation of the dry-bulb air temperature and thus reduce heat stress in most cases,especially for hot and humid environments.It can be concluded that the EnD index has the potential to replace the WBGT index as the standard heat stress index in the future. 展开更多
关键词 heat stress wet-bulb globe temperature(WBGT) specific enthalpy indoor environment maximum allowable duration of heat exposure
下载PDF
Hardware Implementation of STM32 Microcontroller-Based Indoor Environment Monitoring System 被引量:2
2
作者 Luyong Ren Xiaoyu Yu 《Open Journal of Applied Sciences》 2021年第9期997-1008,共12页
Microcontroller <span><span><span style="font-family:;" "="">is </span></span></span><span><span><span style="font-family:;" "... Microcontroller <span><span><span style="font-family:;" "="">is </span></span></span><span><span><span style="font-family:;" "="">widely</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">used in the intelligent life of modern society. Intelligent development based</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">on Microcontroller to solve the actual needs of people</span></span></span><span><span><span style="font-family:;" "="">’</span></span></span><span><span><span style="font-family:;" "="">s life, work, study and</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">other fields is the core of Microcontroller application.</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span><span><span style="font-family:;" "="">Therefore, it is a task for researchers to understand the structure and performance of microcontroller, develop software, and be familiar with the method and process of intelligent development based on microcontroller. And with that in mind</span></span></span><span><span><span style="font-family:;" "="">, t</span></span></span><span><span><span style="font-family:;" "="">his paper designs and produces a physical hardware system for indoor environment detection based on STM32 microcontroller. The system can detect the light intensity, temperature and humidity, and CO gas concentration in the indoor environment;and the data is integrated and processed by the STM32 microcontroller to display the current parameter values of each quantity in the indoor environment on a 3.5-inch resistive screen;at the same time, the PC can also log in to the OneNET cloud platform through the web page, and display the light intensity, temperature and humidity, and CO gas concentration values in the indoor environment in real time in the device created by OneNET for real-time viewing. The system can also display the light intensity, temperature and humidity, and CO gas concentration values in the indoor environment in real time. The hardware system has been tested and tested to achieve its function.</span></span></span> 展开更多
关键词 STM32 MCU indoor environment OneNET Cloud Platform Hardware System
下载PDF
Influence of the 60 Hz Magnetic Field on the Airborne Microbial Distribution of Indoor Environments
3
作者 Matilde Anaya Sofia F.Borrego +2 位作者 Miguel Castro Oderlaise Valdés Alian Molina 《Journal of Atmospheric Science Research》 2020年第3期23-32,共10页
The aim of this work was to analyze the effect of the magnetic field generated by the household appliances on the airborne microbial surrounding these equipment located on indoor environments with particular interest ... The aim of this work was to analyze the effect of the magnetic field generated by the household appliances on the airborne microbial surrounding these equipment located on indoor environments with particular interest in the environmental fungi.A simultaneous environmental study was carried out in locals of three different geographical places of Havana,Cuba,which have televisions,computers and an electric generator.The air samples were made by a sedimentation method using Malt Extract Agar.The concentration of total aerobic mesophilic as well as fungi and yeasts were determined in rainy and little rainy seasons by applying as factors:exposure time of dishes(5 to 60 min)and distance to the wall(0 and 1 m)at a height of 1 m above the floor.The predominant fungal genera were Cladosporium,Penicillium and Aspergillus.In the dishes that were placed at 0 and 0.5 m from the emitting sources were observed that some bacteria colonies formed inhibition halos,a great diversity of filamentous fungi and an increase in the mycelium pigmentation as well as the pigments excretion.In the rainy season,the highest amounts of fungi were obtained in all samples.In the little rain season the count of the Gram-negative bacilli increased three times the Gram-positive cocci. 展开更多
关键词 Non-ionizing radiation Appliances Airborne mycobiota indoor environment Index of microbial air Magnetic field
下载PDF
Indoor Environment Quality Monitoring and Evaluation System Based on LoRa Communication
4
作者 Jiawen Jiang Wenzhong Zhu +1 位作者 Xinhuang Xie Qikang Wei 《Journal of Computer and Communications》 2022年第4期72-86,共15页
Indoor environmental quality has always been the focus of people’s long-term attention. How to monitor the indoor environmental level conveniently and accurately is a problem that people pay attention to now. After r... Indoor environmental quality has always been the focus of people’s long-term attention. How to monitor the indoor environmental level conveniently and accurately is a problem that people pay attention to now. After research, an indoor environment level monitoring system based on LoRa communication is designed. The system is mainly divided into two parts, the detection node, and the monitoring terminal. Temperature, humidity, light intensity, noise, formal-dehyde, and carbon dioxide are detected through the node with STM32F103ZET6 microcontroller as the controller;the data is sent to the monitoring terminal for display through LoRa communication. At the same time, the T-S fuzzy neural network (TSFNN) is improved by the particle swarm optimization (PSO) algorithm to classify the indoor environment quality level. Experimental test: the total error of the improved TSFNN model test set is reduced by 8.6007. The system can monitor the indoor environment level objectively and reliably, and has high practical value. 展开更多
关键词 LoRa Communication STM32 T-S Fuzzy Neural Network Particle Swarm Optimization indoor environmental Quality Evaluation
下载PDF
Energy consumption,indoor environmental quality,and benchmark for office buildings in Hainan Province of China 被引量:1
5
作者 孔祥飞 吕石磊 +1 位作者 辛亚娟 吴薇 《Journal of Central South University》 SCIE EI CAS 2012年第3期783-790,共8页
With rapid economy growth,building energy consumption in China has been gradually increased.The energy consumption and indoor environmental quality of 51 office buildings in Hainan Province,a hot and humid area,were s... With rapid economy growth,building energy consumption in China has been gradually increased.The energy consumption and indoor environmental quality of 51 office buildings in Hainan Province,a hot and humid area,were studied through collection of verified data in site visits and field tests.The result revealed that,electricity accounted for 99.79% of the total energy consumption,natural gas 0.17%,and diesel 0.04%.The air conditioning dominated the energy use with a share of 43.18%,equipment in the particular areas 26.90%,equipment in the office rooms 11.95%,lighting system 8.67%,general service system 7.57%,and miscellaneous items 1.73%.Statistical method including six indicators obtained the energy consumption benchmark with upper limit of 98.31 kW-h/m2 and lower limit of 55.26 kW-h/m2.According to ASHRAE standard(comfortable standard) and GB/T 18883-2002(acceptable standard),the indoor environmental quality of 51 sampled office buildings was classified into three ranks:good,normal and bad.With benchmark of building energy consumption combined with indoor environmental quality,it was found that only 3.92% of sampled buildings can be identified as the best performance buildings with low energy consumption and advanced indoor environmental quality,and the buildings classified into normal level accounted for the maximum ratio. 展开更多
关键词 室内环境质量 能源消耗 海南省 基准 办公大楼 中国 舒适标准 建筑能耗
下载PDF
Questionnaire Research on Indoor Environment Quality i n China 被引量:3
6
作者 朱能 刘俊杰 《Transactions of Tianjin University》 EI CAS 2003年第2期157-160,共4页
With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that ther... With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that there is a significant sensitivity differen ce in indoor environment between southerners and northerners in China. People fr om different regions have different demands for their working and living environ ment. Therefore, as a good design of air conditioning system, it is strongly rec ommended that the different demands of people from different regions should be t aken into consideration. 展开更多
关键词 中国 室内环境质量 问卷调查 室内空气温度 室内空气湿度 热舒适性
下载PDF
Investigating path loss characteristics of UWB signals in vacancy indoor environment based on time-domain technique 被引量:3
7
作者 Wang Yang Zhang Naitong 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2006年第2期296-302,共7页
The path loss analysis model based on 5 rays in vacancy indoor environment is proposed. The relationship between multipath overlapping and the path loss is analyzed mathematically. Time-domain technique is introduced ... The path loss analysis model based on 5 rays in vacancy indoor environment is proposed. The relationship between multipath overlapping and the path loss is analyzed mathematically. Time-domain technique is introduced to compute reflection coefficient in a very short time interval. A 5 rays path loss calculation method, which is satisfactory accurate, is developed. 5 typical environments are involved to analyze and generalize the common path loss characteristics in vacancy indoor environment. The simulation result shows that the path loss can be characterized as 3 zones with different path loss exponent as distance between transmitter and receiver increasing. 展开更多
关键词 UWB 路径 时间域 内部环境 信号处理
下载PDF
Subjective evaluation of indoor environmental quality of underground shopping malls in central district of Chongqing,China
8
作者 高俊敏 张科 +1 位作者 蒲清平 张英 《Journal of Central South University》 SCIE EI CAS 2009年第S1期12-16,共5页
Good indoor environmental quality enhances occupant health,comfort and productivity. In order to know the status of indoor environmental quality of underground shopping malls,five large underground shopping malls in f... Good indoor environmental quality enhances occupant health,comfort and productivity. In order to know the status of indoor environmental quality of underground shopping malls,five large underground shopping malls in five central districts of Chongqing,China,were surveyed. 2 411 questionnaires were distributed,and 98.5% of them were returned. From the results of questionnaire survey,the following conclusions were obtained:(1) in the five underground shopping malls surveyed,only shopping mall D in Nan'an district accords with the ASHRAE standard for good indoor air quality; (2) odors and sick building syndrome (SBS) symptoms are widespread in the underground shopping malls. The SBS occurrence rates for women and salespersons are higher than those of men and customers,respectively; (3) in the evaluation of the indoor environment,the indoor air quality dissatisfaction rate is the highest,followed by the thermal environment; and (4) women and salespersons generally have higher rates of dissatisfaction with the indoor environmental quality of underground shopping malls than men and customers,respectively. 展开更多
关键词 SUBJECTIVE evaluation sick building syndrome (SBS) indoor environmental quality UNDERGROUND SHOPPING MALLS
下载PDF
Determining indoor air quality and identifying the origin of odour episodes in indoor environments 被引量:14
9
作者 Eva Gallego Xavier Roca +1 位作者 Jose Francisco Perales Xavier Guardino 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第3期333-339,共7页
A methodology for identifying volatile organic compounds(VOCs) and determining air quality of indoor air has been developed.The air samples are collected using pump samplers by the inhabitants when they perceive odoro... A methodology for identifying volatile organic compounds(VOCs) and determining air quality of indoor air has been developed.The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes.Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC.The analysis is performed by automatic thermal desorption(ATD) coupled with gas chromatography-mass spectrometry(GC/MS).This methodology can be applied in cases of sick building syndrome(SBS) evaluation,in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building.Chemical pollutants concentrations(e.g.,VOC) have been described to contribute to SBS.To exemplify the methodology,a qualitative determination and an evaluation of existing VOC were performed in a dwelling where the occupants experienced the SBS symptoms.Higher total VOC(TVOC) levels were detected during episodes in indoor air(1.33 ± 1.53 mg/m3) compared to outdoor air(0.71 ± 0.46 mg/m3).The concentrations of individual VOCs,such as ethanol,acetone,isopropanol,1-butanol,acetic acid,acetonitrile and 1-methoxy-2-propanol,were also higher than the expected for a standard dwelling.The external source of VOC was found to be an undeclared activity of storage and manipulation of solvents located at the bottom of a contiguous building. 展开更多
关键词 室内空气质量 总挥发性有机化合物 室内环境 气味 气相色谱质谱 VOCs 化学污染物 SBS
下载PDF
Computer-Vision Based Object Detection and Recognition for Service Robot in Indoor Environment 被引量:1
10
作者 Kiran Jot Singh Divneet Singh Kapoor +2 位作者 Khushal Thakur Anshul Sharma Xiao-Zhi Gao 《Computers, Materials & Continua》 SCIE EI 2022年第7期197-213,共17页
The near future has been envisioned as a collaboration of humans with mobile robots to help in the day-to-day tasks.In this paper,we present a viable approach for a real-time computer vision based object detection and... The near future has been envisioned as a collaboration of humans with mobile robots to help in the day-to-day tasks.In this paper,we present a viable approach for a real-time computer vision based object detection and recognition for efficient indoor navigation of a mobile robot.The mobile robotic systems are utilized mainly for home assistance,emergency services and surveillance,in which critical action needs to be taken within a fraction of second or real-time.The object detection and recognition is enhanced with utilization of the proposed algorithm based on the modification of You Look Only Once(YOLO)algorithm,with lesser computational requirements and relatively smaller weight size of the network structure.The proposed computer-vision based algorithm has been compared with the other conventional object detection/recognition algorithms,in terms of mean Average Precision(mAP)score,mean inference time,weight size and false positive percentage.The presented framework also makes use of the result of efficient object detection/recognition,to aid the mobile robot navigate in an indoor environment with the utilization of the results produced by the proposed algorithm.The presented framework can be further utilized for a wide variety of applications involving indoor navigation robots for different services. 展开更多
关键词 Computer-vision real-time computing object detection ROBOT robot navigation LOCALIZATION environment sensing neural networks YOLO
下载PDF
New Trends of Material Design in Indoor Environment
11
作者 WANG Xiaonan ZHANG Ruizhi 《Journal of Landscape Research》 2017年第3期118-120,共3页
Material is the substance foundation and carrier of indoor environment, and it is the premise and guarantee to realize the excellent indoor environment. It contains physical and sensory properties. In recent years, th... Material is the substance foundation and carrier of indoor environment, and it is the premise and guarantee to realize the excellent indoor environment. It contains physical and sensory properties. In recent years, the material design in indoor environment tends to be more rational, it not only pursues the external performance of material, but also pays more attention to the health and emotional of residents on the basis of scientific and rational use of its properties. This paper based on some scientific methods of literature study, field survey and case study combs the new trends of material design and analyses specific performance and application of materials in development. It is expected that the research can enrich the theory of contemporary material design and provide valuable reference for future material and interior environment design. 展开更多
关键词 MATERIAL MATERIAL DESIGN indoor environment INTERIOR DESIGN New TRENDS
下载PDF
Indoor Environmental Requirements in Green Building in Jordan
12
作者 Mayyadah Fahmi Hussein 《Journal of Civil Engineering and Architecture》 2014年第5期557-566,共10页
关键词 室内环境质量 绿色建筑 约旦 设计标准 健康问题 热舒适性 研究人员 应用程序
下载PDF
Indoor Environmental Quality of Air Conditioned Residential Buildings in Extreme Dry Desert Climate
13
作者 Farraj F. Al-Ajmi 《Journal of Power and Energy Engineering》 2018年第8期86-97,共12页
In this study, the indoor environmental quality (IEQ) in air conditioned residential buildings in a dry desert climate is examined from the perspective of occupants via two aspects: thermal comfort and indoor air qual... In this study, the indoor environmental quality (IEQ) in air conditioned residential buildings in a dry desert climate is examined from the perspective of occupants via two aspects: thermal comfort and indoor air quality. The study presents statistical data about the domestic-occupant thermal comfort sensations together with data describing the indoor air quality in Kuwaiti residential buildings. With respect to the latter, the overall IEQ acceptance using two measurements namely: physical measurements and subjective information collected via questionnaires, was used to evaluate 111 occupants living in twenty five air-conditioned residential buildings in the state of Kuwait. The operative temperature based on Actual Mean Vote (AMV) and Predicted Mean Vote (PMV) was identified using linear regression analysis of responses on the ASHRAE seven-point thermal sensation scale and was found to be 25.2°C and 23.3°C, respectively, in the summer season. Indoor air quality (IAQ) with respect to carbon dioxide concentration level was compared with the acceptable limits of international standards, i.e. ASHRAE Standard 62.1 [1]. The proposed overall IEQ acceptance findings in residential buildings show CO2 concentration level between 909 and 1250 ppm. However, this may be considered a higher level of CO2 concentration, which may require increasing ventilation rate through window operation or mechanical ventilation. 展开更多
关键词 RESIDENTIAL Buildings RESIDENTIAL indoor environments indoor Air Quality Thermal COMFORT DRY DESERT CLIMATES
下载PDF
Precise Transceiver-Free Localization in Complex Indoor Environment 被引量:3
14
作者 Rui Mao Peng Xiang Dian Zhang 《China Communications》 SCIE CSCD 2016年第5期28-37,共10页
Transceiver-free object localization can localize target through using Radio Frequency(RF) technologies without carrying any device, which attracts many researchers' attentions. Most traditional technologies usual... Transceiver-free object localization can localize target through using Radio Frequency(RF) technologies without carrying any device, which attracts many researchers' attentions. Most traditional technologies usually first deploy a number of reference nodes which are able to communicate with each other, then select only some wireless links, whose signals are affected the most by the transceiver-free target, to estimate the target position. However, such traditional technologies adopt an ideal model for the target, the other link information and environment interference behavior are not considered comprehensively. In order to overcome this drawback, we propose a method which is able to precisely estimate the transceiver-free target position. It not only can leverage more link information, but also take environmental interference into account. Two algorithms are proposed in our system, one is Best K-Nearest Neighbor(KNN) algorithm, the other is Support Vector Regression(SVR) algorithm. Our experiments are based on Telos B sensor nodes and performed in different complex lab areas which have many different furniture and equipment. The experiment results show that the average localization error is round 1.1m. Compared with traditional methods, the localization accuracy is increased nearly two times. 展开更多
关键词 定位精度 收发器 室内环境 传感器节点 支持向量回归 传统方法 收发信机 无线链路
下载PDF
Dynamic characteristics and comfort assessment of airflows in indoor environments: A review 被引量:5
15
作者 Yingxin Zhu Maohui Luo Qin Ouyang Li Huang Bin Cao 侯恩哲 《建筑节能》 CAS 2015年第9期12-12,共1页
During the past few decades, both positive and negative aspects of indoor air movement on human comfort perception have been studied. However, most research has focused on collecting empirical evidence to support the ... During the past few decades, both positive and negative aspects of indoor air movement on human comfort perception have been studied. However, most research has focused on collecting empirical evidence to support the potential application of airflows in practice. In this context, numerous studies have encouraged the use of moving air to promote comfort in warm environments, especially with regard to the application of dynamic airflows. Through these studies, the effects of different airflow parameters(such as air velocity, turbulence intensity, and fluctuation frequency) on human comfort perception have gradually been identified and even quantified. This article aims to summarize the progress in the literature concerning dynamic characteristics and comfort assessment of airflows in four main sections: demand for indoor airflows, parameters of indoor airflows, comfort assessment of indoor airflows, and dynamic airflows and their application.This paper will hopefully aid the understanding of human perception of indoor airflows and guide future research. 展开更多
关键词 建筑设计 建筑节能 建筑光学 建筑材料
下载PDF
An Assessment of Indoor Environmental Quality in School Buildings in the State of Kuwait
16
作者 Jamal Al-Hubail Abdul-Salam Al-Temeemi 《Frontiers Research of Architecture and Engineering》 2019年第2期5-19,共15页
In this study, indoor quality and environmental comfort were investigated in secondaiy school buildings located in the State of Kuwait. Comfort variables such as temperature and relative humidity (thermal comfort), no... In this study, indoor quality and environmental comfort were investigated in secondaiy school buildings located in the State of Kuwait. Comfort variables such as temperature and relative humidity (thermal comfort), noise (acoustic comfort), illumination (visual comfort), as well as allocated classroom floor area per student (spatial comfort) were measured. Data was collected over a 7-month period on a spot basis during school hours in student-occupied classrooms at 46 selected schools. The measured data was then compared to international guidelines and standards related to indoor environment quality. The data for noise and allocated space were shown to be in the comfort ranges in all the schools. However, 11% of the schools are not adequately illuminated, 33% had temperatures not within the recommended limits, and 22% of the schools had humidity levels either higher or lower than the recommended levels. Also, 9% of the schools had low illummation readings. In addition, during the data monitoring, a survey was conducted by which the student occupants completed a questionnaire so that subjective and objective evaluations could be compared. The findings of the questionnaire displayed significant correlations between the measured data and some ailments and other corr^laints experienced by the students. Ultimately, the results found in this research will provide a baseHne for comparison with future indoor environment quality assessments in buildings. Furthermore, recommendations are suggested in order to improve the environmental quality problems encountered in some of the schools, which may be beneficial for policymakers, facilities managers, and design engineers. 展开更多
关键词 BUILDING environment sick BUILDING syndrome CLASSROOM environment indoor physical parameters Temperature RELATIVE humidity Illummation Noise Space density
下载PDF
Thermal comfort in naturally ventilated indoor environment in hot and humid climate zone in P. R. China
17
作者 李文杰 李百战 +1 位作者 许孟楠 景胜蓝 《Journal of Central South University》 SCIE EI CAS 2009年第S1期33-37,共5页
To identify human thermal comfort in naturally ventilated buildings,the research based on both subjective and objective data was carried out in Chongqing,P. R. China. The characteristics of subjects' clothing regu... To identify human thermal comfort in naturally ventilated buildings,the research based on both subjective and objective data was carried out in Chongqing,P. R. China. The characteristics of subjects' clothing regulation function,changes of actual mean thermal comfort vote (AMV) varying with time and acceptable operative temperature in natural conditions were analyzed. In addition,the indicator actual mean vote-actual percentage dissatisfied (AMV-APD) was used to study the actual dissatisfaction with thermal environment. The results indicate that regulative ability by changing clothing under natural ventilated conditions is very significant but limited simultaneously,about 1.7 ℃ per 0.1 clo. Under naturally ventilated conditions,people may have an acceptable operative temperature of 16-28 ℃. Based on the AMV-APD,the actual minimum percentage dissatisfied can reach 4% at AMV of -0.36. 展开更多
关键词 THERMAL COMFORT THERMAL environment actual mean VOTE (AMV) actual PERCENTAGE dissatisfied (APD) natural ventilation OPERATIVE temperature
下载PDF
Wireless Network Requirements and Solutions for the Future Circular Collider:A Hostile Indoor Environment
18
作者 Ahmed Bannour Yichuang Sun 《China Communications》 SCIE CSCD 2021年第10期193-203,共11页
The European organization for nuclear research(CERN)is planning a high performance particle collider by 2050,which will update the currently used Large Hadron Collider(LHC).The design of the new experiment facility in... The European organization for nuclear research(CERN)is planning a high performance particle collider by 2050,which will update the currently used Large Hadron Collider(LHC).The design of the new experiment facility includes the definition of a suitable communication infrastructure to support the future needs of scientists.The huge amount of data collected by the measurement devices call for a data rate of at least 1 Gb/s per node,while the need of timely control of instruments requires a low latency of the order of 0.01μs.Moreover,the main tunnel will be 100 km long,and will need appropriate coverage for voice and data traffic,in a special underground environment subject also to strong radiations.Reliable voice,data and video transmission in a tunnel of this length is necessary to ensure timely and localized intervention,reducing access time.In addition,using wireless communication for voice,control and data acquisition of accelerator technical systems could lead to a significant reduction in cabling costs,installation times and maintenance efforts.The communication infrastructure of the Future Circular Collider(FCC)tunnel must be able to circumvent the problems of radioactivity,omnipresent in the tunnel.Current technologies transceivers cannot transmit in such a severely radioactive environment.This is due to the immediate destruction of any active or passive equipment by radioactivity.The scope of this paper is to determine the feasibility of robust wireless transmission in an underground radioactive tunnel environment.The network infrastructure design to meet the demand will be introduced,and the performance of different wireless technologies will be evaluated. 展开更多
关键词 future circular collider LHC TUNNEL low latency harsh indoor wireless communications
下载PDF
Review on Mould Contamination and Hygrothermal Effect in Indoor Environment
19
作者 Yuyan He Qinghai Luo +2 位作者 Peihong Ge Guojie Chen Hanqing Wang 《Journal of Environmental Protection》 2018年第2期100-110,共11页
Mould is an important factor which affects building environment and indoor air quality. Firstly, a variety of damages of mould contamination to human and building are reviewed. Then, the crucial factors of mould growt... Mould is an important factor which affects building environment and indoor air quality. Firstly, a variety of damages of mould contamination to human and building are reviewed. Then, the crucial factors of mould growth are analyzed;temperature and humidity are key factors. After that, the indoor mould growth models were analyzed. Heat and moisture transfer in building envelope is a key factor which affects mould growth environment;wall is sensitive to reach the critical condition which leads to mould growth and reproduction, results in contamination. 展开更多
关键词 MOULD CONTAMINATION Building environment MOULD Growth Model HEAT and MOISTURE TRANSFER
下载PDF
Localizing Jammer in an Indoor Environment by Estimating Signal Strength and Kalman Filter
20
作者 Waleed Aldosari Mohamed Zohdy 《Wireless Engineering and Technology》 2018年第2期20-33,共14页
Localizing a jammer in an indoor environment in wireless sensor networks becomes a significant research problem due to the ease of blocking the communication between legitimate nodes. An adversary may emit radio frequ... Localizing a jammer in an indoor environment in wireless sensor networks becomes a significant research problem due to the ease of blocking the communication between legitimate nodes. An adversary may emit radio frequency to prevent the transmission between nodes. In this paper, we propose detecting the position of the jammer indoor by using the received signal strength and Kalman filter (KF) to reduce the noise due to the multipath signal caused by obstacles in the indoor environment. We compare our work to the Linear Prediction Algorithm (LP) and Centroid Localization Algorithm (CL). We observed that the Kalman filter has better results when estimating the distance compared to other algorithms. 展开更多
关键词 JAMMER Detecting Kalman Filter (KF) Linear Prediction (LP) CENTROID Localization (CL) JAMMER RECEIVED SIGNAL Strength (JRSS) MULTIPATH SIGNAL indoor Location
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部